Loading...
HomeMy WebLinkAboutS-392108NW 20-23-05 N s �SS- SSMH 2309 T.E.S.C. LEGEND: CITY OF RENTON SEWER AND ACCESS EASEMENT TEMPORARY CONSTRUCTION PERMIT LIMIT x x x x ORANGE CONSTRUCTION FENCING — CLEARING LIMITS / PUGET SOUND SILT FENCING X ENERGY DOUBLE SILT FENCING 90�0 PROPOSED GRAVITY WALL OR ROCKERY Q CATCH BASIN FILTER STABILIZED CONSTRUCTION ENTRANC T. E.S.C. NOTE: 1. SLOPES GREATER THAN 3:1 REQUIRE SURFACE ROUGHING, SEE DETAIL 1, SHEET 50, 2. PROVIDE PERMANENT SLOPE STABILIZATION FOR SLOPES GREATER THAN 2:1, SEE DETAIL 4, SHEET 50, 3. CONTRACTOR SHALL NOT PERFORM ANY WORK BELOW THE ORDINARY HIGH WATER LINE IN THUNDER CREEK Stantec 1687 114TH Avenue SE, Suite 100 Bellevue WA 98004 phone: (425) 869-9448 www.stantec.com 6'H 2 TIER GABION WALL SEX ROCKERY/ / 11 =105 1 05 PUGET SOUND ENERGY 9050 WITH ORANGE .. CONSTRUCTION FENCING, DETAIL 1, SHEET 49 (TYP) -6'H 2 TIER GABION WEE- RK 55 I Cl) I / l RK .ri.ri —EXISTING ROCKERY_ TO REMAIN - SDI IE 16"CMP SE= 100.94 INLET NOT LOCATED SSMH 310----- SCALE 20 0 20 40 (FEET) 1 INCH = 20 FT SSMH2730 RIM= 153.00 IE NE= 144.4 IE SW= 144.5 1—I-405 WSDOT LIMITED SPACED 3' APART DETAIL 2, SHEET 49 (TYP) PUGET SOUND ENERGY 9005 FLAG WETLAND EDGE W/ SENSITIVE AREA WARNING TAPE. W y� PUGET SOUND ENERGY �' ZED co 'ATER co t� co / LU I / WOODCLIFFE APTS. SDMH LID / PROPOSED CITY OF RENTON 9112 DOUBLE SILT FENCING, RIM= 152.17 SEWER AND ACCESS SPACED 3' APART DETAIL 2, SHEET 49 (TYP) CENTER OF 7' 0 EASEMENT (TYP) STRUCTURE TOP OF ROCKS EDGE OF AT DROP FLOWING WATER EXPOSED TOP OF TEMPORARY STRUCTURE EX ROCKERY CONSTRUCTION EDGE OF EX GRAVEL ROAD r PERMIT LIMIT (TYP) Q 750�� ���� 155— T _ 125 _12511 120� — 115. 1 5 CV 120 / �50 ��s ss / ; OF / CID ss---- ' LUWI G W TER i - /SS SS U) GRAVEL / PATH w x x x— J `/ /// ��/ '�// � � �\�15 �. J-" / • . �—EXISTING ROCKERY j��O REMAIN�� _EXISTING CITY OF RENTON-----.... �/ jam• �� (— CLEARING LIMITS _ ^20' SEWER AND ACCESS �� Q (TYP) f EASEMENT (TYP) 160 TOP . . MARK CLEARING LIMITS WITH ORANGE / /— CONSTRUCTION FENCING, DETAIL 1, SHEET 49 (TYP) ���/ BERKSHIRE APTS. \ 9113 a S-392108 KEY MAP Stantec was not present on site during construction. These record drawings are a compilation of a copy of the sealed engineering drawings for this project, as modified by information furnished by the as -built survey on the project. The information shown on the record drawings that was provided by the City Utilities Dept. inspector cannot be verified for accuracy or completeness. The original sealed drawings are on file at the offices of the City of Renton. RECORD DRAWING DAM