HomeMy WebLinkAboutS-392108NW 20-23-05
N
s
�SS-
SSMH 2309
T.E.S.C. LEGEND:
CITY OF RENTON SEWER
AND ACCESS EASEMENT
TEMPORARY CONSTRUCTION
PERMIT LIMIT
x x x x ORANGE CONSTRUCTION FENCING
— CLEARING LIMITS / PUGET SOUND
SILT FENCING X ENERGY
DOUBLE SILT FENCING 90�0
PROPOSED GRAVITY WALL OR ROCKERY
Q CATCH BASIN FILTER
STABILIZED CONSTRUCTION ENTRANC
T. E.S.C. NOTE:
1. SLOPES GREATER THAN 3:1 REQUIRE SURFACE
ROUGHING, SEE DETAIL 1, SHEET 50,
2. PROVIDE PERMANENT SLOPE STABILIZATION FOR
SLOPES GREATER THAN 2:1, SEE DETAIL 4, SHEET
50,
3. CONTRACTOR SHALL NOT PERFORM ANY WORK BELOW
THE ORDINARY HIGH WATER LINE IN THUNDER CREEK
Stantec
1687 114TH Avenue SE, Suite 100 Bellevue WA
98004 phone: (425) 869-9448 www.stantec.com
6'H 2 TIER
GABION WALL
SEX ROCKERY/
/
11
=105 1
05
PUGET SOUND
ENERGY
9050
WITH ORANGE ..
CONSTRUCTION FENCING,
DETAIL 1, SHEET 49 (TYP)
-6'H 2 TIER
GABION WEE-
RK 55 I Cl) I / l
RK .ri.ri
—EXISTING ROCKERY_
TO REMAIN -
SDI
IE 16"CMP SE= 100.94
INLET NOT LOCATED
SSMH 310-----
SCALE
20 0 20 40
(FEET)
1 INCH = 20 FT
SSMH2730
RIM= 153.00
IE NE= 144.4
IE SW= 144.5
1—I-405 WSDOT LIMITED
SPACED 3' APART
DETAIL 2, SHEET 49 (TYP)
PUGET SOUND
ENERGY
9005
FLAG WETLAND EDGE W/
SENSITIVE AREA WARNING
TAPE.
W y�
PUGET SOUND
ENERGY �'
ZED co
'ATER co
t�
co
/ LU
I
/ WOODCLIFFE APTS.
SDMH LID
/ PROPOSED CITY OF RENTON 9112 DOUBLE SILT FENCING, RIM= 152.17
SEWER AND ACCESS SPACED 3' APART
DETAIL 2, SHEET 49 (TYP) CENTER OF 7' 0
EASEMENT (TYP) STRUCTURE
TOP OF ROCKS EDGE OF
AT DROP FLOWING WATER EXPOSED TOP OF
TEMPORARY STRUCTURE
EX ROCKERY CONSTRUCTION EDGE OF EX
GRAVEL ROAD
r PERMIT LIMIT (TYP) Q
750�� ���� 155— T
_ 125
_12511
120� —
115. 1
5 CV
120 / �50 ��s ss / ; OF / CID
ss---- ' LUWI G W TER
i
-
/SS SS U)
GRAVEL /
PATH w
x x x— J
`/ /// ��/ '�// � � �\�15 �. J-" / • . �—EXISTING ROCKERY
j��O REMAIN�� _EXISTING CITY OF RENTON-----.... �/ jam• �� (—
CLEARING LIMITS _ ^20' SEWER AND ACCESS �� Q
(TYP) f EASEMENT (TYP) 160
TOP . .
MARK CLEARING LIMITS
WITH ORANGE / /—
CONSTRUCTION FENCING,
DETAIL 1, SHEET 49 (TYP) ���/ BERKSHIRE APTS.
\ 9113 a
S-392108
KEY MAP
Stantec was not present on site during construction. These
record drawings are a compilation of a copy of the sealed
engineering drawings for this project, as modified by
information furnished by the as -built survey on the project.
The information shown on the record drawings that was
provided by the City Utilities Dept. inspector cannot be
verified for accuracy or completeness. The original sealed
drawings are on file at the offices of the City of Renton.
RECORD DRAWING
DAM