HomeMy WebLinkAboutP_Neighborhood_Detail_Map_Site_Plan_Proposed_Floor_Plan_and_Exterior_Elevations_170829_v1NE21STST. (N)SIDEWALK MATACH(E)(E) P.L.(N) P.LP.L. = 163.25'(E) SIDEWALK(N) LANDSCAPE(E) SIDEWALK(E) PARKING(E) SEWER LINE(E) GASLINE(E) TREEP.L. = 403.63'PROPOSED ADDITION 1671SF(E) SANCTUARY(E) SIDEWALKP.L. = 163.25'(E) TREES435'435'P.L. = 95.92'P.L. = 217.5'PROPOSED RAMP (1:12 SL)(E) COV'D MAIN ENTRY435'(E) PARKING435'(E) ASPHALT PARKING(E) SIDEWALK(E) FIRE HYDRANT(E) PARKING435'P.P. = 107.01'PS - (E) PARKING STALL*TOTAL PARKING 103 STALLS435'11 PS3 PS11 PS11 PS10 PS435'P.L. =200.83'13 PS11 PS(E) GRASS AREA14 PS9 PS10 PS31' - 5"69' - 6"52' - 0"80' - 0"24' - 0"17' - 6"LANDSCAPINGEXIST. LANDSCAPING(E) CLASSROOMS ANDOFFICESAREA OF INTERIOR REMODELNEW SPRINKLER RISER RM, SEE A2.1FDC & PIV LOCATION, VERIFY WITH SPRINKLER CONTRACTOREXISTING WATER LINE TO HYDRANT - VERIFY LOCATIONPROPOSED WATER LINE TO NEW SPRINKLER RM. LOCATION - SEE PLANS. SIZE OF MAIN TO BE DETERMINED BY SPRINKLER CONTRACTOR UNDER SEPARATE BIDDER/DESIGN PERMIT SUBMITTAL(E) WTR METERSEE CIVIL DWGS / SITE DEVELOPMENT APPLICATION FOR FRONTAGE IMPROVEMENTS28' - 8 1/2"138'-3".14' - 4 3/8"P.L. = 217.5'21620 84th Ave. S.Ste. 200Kent, WA 98032(253) 468-7696www.ihbarchitects.comIHBThe drawings and plans set forth onthis set as instrument of service are,and shall remain, the property ofIHB Architects. Use of this drawingis limited to a specified project forpersons named hereon. And for aconstruction of one building. Anyuse or reuse of said drawings isstrictly prohibited without writtenpermission of IHB ArchitectsPARCEL NO:drawn by:date:job No:reviewed by:revisions:IHB4230592378/30/2017 4:47:48 PMA1.0A1.0 SITE PLANFUPC - Sanctuary Addition & Remodel3811 NE 21st St,Renton, WA 98056Project NumberAug XX, 2017JK/OG/DSN.SCALE: 1" = 20'-0"SITE - Existing21620 84th Ave. S.Ste. 200Kent, WA 98032(253) 468-7696www.ihbarchitects.comIHBThe drawings and plans set forth onthis set as instrument of service are,and shall remain, the property ofIHB Architects. Use of this drawingis limited to a specified project forpersons named hereon. And for aconstruction of one building. Anyuse or reuse of said drawings isstrictly prohibited without writtenpermission of IHB ArchitectsPARCEL NO:drawn by:date:job No:reviewed by:revisions:IHB4230592378/30/2017 4:47:49 PMA1.0A1.0 SITE PLANFUPC - Sanctuary Addition & Remodel3811 NE 21st St,Renton, WA 98056Project NumberAug XX, 2017JK/OG/DS
SITE LOCATION21620 84th Ave. S.Ste. 200Kent, WA 98032(253) 468-7696www.ihbarchitects.comIHBThe drawings and plans set forth onthis set as instrument of service are,and shall remain, the property ofIHB Architects. Use of this drawingis limited to a specified project forpersons named hereon. And for aconstruction of one building. Anyuse or reuse of said drawings isstrictly prohibited without writtenpermission of IHB ArchitectsPARCEL NO:drawn by:date:job No:reviewed by:revisions:IHB4230592378/30/2017 4:47:49 PMA1.0AA1.0A NeighborhoodDetail MapFUPC - Sanctuary Addition & Remodel3811 NE 21st St,Renton, WA 98056Project NumberAug XX, 2017AuthorSCALE: 1" = 200'-0"Neighborhood Detail MapN.
UPUPDN(E) CLASSROOM(E) WOMEN'S(E) MEN'S(E) STO.(E) STORAGE. SANCTUARY (360 SEATS)(E) MAIN LOBBY(E) MEETING RMSEATING = 140(E) CLASSROOM(E) WOMEN'S BATH.(E) MEN'S BATH.(E) CLASSROOM(E) CLASSROOM(E) CLASSROOM(E) CLASSROOM(E) CLASSROOM(E) CLASSROOM(E) CLASSROOM(E) 5 TOILETS(E) 3 SINKS(E) URINALS(E) 2 TOILETS(2) SINKS(E) COVERED ENTRY(R) CHOIR STAGEEXIST WALL LINEDROP DOWN SCREEN+21"STOR.LANDSCAPING(N) LOBBY ADDITION+0" FIN. FLR.(N) SANCTUARY ADDITION+12" FIN.FLR.A /V / L BOOTH DN+12" +12" FIN.FLR.DNDN+12" +0" +0" STOR.UPDNUPUPUPALIGNALIGNALIGNSIM.+0" FIN. FLR.CLOSETUPEXIST. STRUCTUREPROPOSED STRUCTURE(72 SEATS)POSSIBLE W/C AREASPOSSIBLE W/C AREA7'-0" 6'-0" 1'-3" 1047' - 0"7' - 0"UPA7.05AREA OF WORK(E) CLASSROOM(E) CLASSROOM(E) CLASSROOM(E) KITCHEN(E) OFFICE(E) LIBRARY(E) BANQUET RM SEATING = 80(E) STORAGE(E) YOUTH OFFICE(E) CLASSROOM(E) CORRIDOR(E) CORRIDOR21620 84th Ave. S.Ste. 200Kent, WA 98032(253) 468-7696www.ihbarchitects.comIHBThe drawings and plans set forth onthis set as instrument of service are,and shall remain, the property ofIHB Architects. Use of this drawingis limited to a specified project forpersons named hereon. And for aconstruction of one building. Anyuse or reuse of said drawings isstrictly prohibited without writtenpermission of IHB ArchitectsPARCEL NO:drawn by:date:job No:reviewed by:revisions:IHB4230592378/30/2017 4:47:55 PMA2.1A2.1 PROPOSEDFLOOR PLANSFUPC - Sanctuary Addition & Remodel3811 NE 21st St,Renton, WA 98056Project NumberAug XX, 2017JS/OG/DSSCALE: 1/8" = 1'-0"PROPOSED MAIN FLOOR PLANN.FLOOR PLAN NOTES1. ALL OUTSIDE AND INSIDE DIMENSIONS ARE TO BE FACE OF STUDS (UNLESS NOTED OTHERWISE ON PLANS).2. WRITTEN DIMENSIONS TAKE PRECEDENCE OVER SCALED DIMENSIONS.3. ALL EXTERIOR DOORS SHALL BE OPENABLE FROM INSIDE WITHOUT USE OF KEYS.4. PROVIDE CONT. HANDRAIL AT STAIRS A MIN. OF 1-1/2" AWAY FROM WALL.5. HANDRAIL ENDS SHALL BE RETURNED OR SHALL TERMINATE IN NEWEL POSTS OR SAFETY TERMINALS.6. FIRE STOPS: FIRE BLOCKING IS REQUIRED IN ALL STUD WALLS AT CEIILNGS & FLOOR LEVELS. THE VERTICAL DISTANCE BETWEEN BLOCKING SHALL NOT EXCEED 10 FT.WALL SCHEDULEWL-1INTERIOR GWB WALL: 5/8" GWB EA. SIDE OF 2x6 WD STUDS @ 16" O.C. EXTERIOR WOOD WALL: 5/8" GWB W/PVA V.B. O/ 2x6 WD STUDS @ 16" O.C. R-21 BATT INSULATION WHERE SHOWN PLUS R-4 CONTINUOUS INSULATION 7/16" OSB SHEATHING MOISTURE BARRIER (TYVEK) EXTERIOR FINISH (SEE ELEV.) WL-3SCALE: 1/8" = 1'-0"PROPOSED LOWER FLOOR PLANN.FIRE SPRINKLER/RISER RM.WL-2 INTERIOR GWB WALL: 5/8" GWB EA. SIDE OF 2x4 WD STUDS @ 16" O.C. SEATING/PARKING DATA:SANCTUARY SEATING = 360CHOIR STAGE SEATING = 72TOTAL SEATING = 442PARKING REQUIRED:432 SEATS / 5 = 88 STALLS EXISTING PARKING = 103 STALLS
LOWER SANCTUARYLEVEL2' - 6"LOWER ROOF PLATE13' - 3"UPPER ROOF PLATE19' - 0"2A5.02A5.0EXIST. STRUCTUREPROPOSED STRUCTUREUPPER SANCTUARYLEVEL3' - 6"PROPOSED ELEVATIONT.O. ROOF26' - 6"LOWER SANCTUARYLEVEL2' - 6"LOWER ROOF PLATE13' - 3"UPPER ROOF PLATE19' - 0"GRADE0"BASEMENT-3' - 0"UPPER SANCTUARYLEVEL3' - 6"(N) HARDIE PANEL & REVEAL SYSTEM101100100PROPOSED ELEVATIONT.O. ROOF26' - 6"LOWER SANCTUARYLEVEL2' - 6"LOWER ROOF PLATE13' - 3"UPPER ROOF PLATE19' - 0"GRADE0"BASEMENT-3' - 0"EXIST. STRUCTUREPROPOSED STRUCTURE3A5.04A5.0103103103103103UPPER SANCTUARYLEVEL3' - 6"PROPOSED ELEVATIONT.O. ROOF26' - 6"LOWER SANCTUARYLEVEL2' - 6"LOWER ROOF PLATE13' - 3"UPPER ROOF PLATE19' - 0"GRADE0"BASEMENT-3' - 0"UPPER SANCTUARYLEVEL3' - 6"102(N) WINDOW, SEE WDW SCHEDT.O. ROOF26' - 6"21620 84th Ave. S.Ste. 200Kent, WA 98032(253) 468-7696www.ihbarchitects.comIHBThe drawings and plans set forth onthis set as instrument of service are,and shall remain, the property ofIHB Architects. Use of this drawingis limited to a specified project forpersons named hereon. And for aconstruction of one building. Anyuse or reuse of said drawings isstrictly prohibited without writtenpermission of IHB ArchitectsPARCEL NO:drawn by:date:job No:reviewed by:revisions:IHB4230592378/30/2017 4:48:04 PMA3.1A3.1 PROPOSEDEXTERIORELEVATIONSFUPC - Sanctuary Addition & Remodel3811 NE 21st St,Renton, WA 98056Project NumberAug XX, 2017OG/DS/JKSCALE: 1/8" = 1'-0"SOUTH ELEVATION-PROPOSEDSCALE: 1/8" = 1'-0"EAST ELEVATION - PROPOSEDSCALE: 1/8" = 1'-0"NORTH ELEVEVATION (NE 21ST ST) - PROPOSEDSCALE: 1/8" = 1'-0"WEST ELEVATION - PROPOSED