Loading...
HomeMy WebLinkAboutP_Architectural_Elevations_170621_v1CONSTRUCTIONFLOOR PLAN0"ROOF PLAN12' - 0"EQEQEQEQBBBBBBBACCCCDDDDDDEFFCGHHIIJJKKKLLMMMMH512512512NNNOOO7' - 6"1' - 6"9' - 0"10' - 11"5' - 3 1/2"6' - 2"5' - 3 1/2"10' - 11"TEMPTEMPTEMPTEMPMIN. 50 PERCENT (50%) TRANSPARENT WINDOWS AND/OR DOORS BETWEEN 4' AND 8' ABOVE GROUNDEXISTING ANDPROPOSED ELEVATIONOVERALL BUILDING HEIGHT22' - 9"CONSTRUCTIONFLOOR PLAN0"ROOF PLAN12' - 0"JJBBBNNO512KDDFFHHIG2' - 0"7' - 0"7' - 6"1' - 6"6' - 0"3' - 0"ALL TANSPARENT CLEAR GLAZING5' MIN. WIDTH PLANTING BEDREFER TO SHEET A2.0Level 8-1' - 6"EXISTING ANDPROPOSED ELEVATIONCONSTRUCTIONFLOOR PLAN0"ROOF PLAN12' - 0"JJNNOKDFG512Level 8-1' - 6"EXISTING ANDPROPOSED ELEVATIONCONSTRUCTIONFLOOR PLAN0"ROOF PLAN12' - 0"16' - 2"J512512512OOONEXISTING ANDPROPOSED ELEVATIONG. MerkelMarch 29 - 20171603 116TH Ave NESheetDate:Drawn By:Scale:Client:Suite 115Bellevue, WA 980041B17001464APRIL 24/2017 1/4" = 1'-0"A3.12800 NE SUNSET BLVD RENTON, WA 98056RENTON SUNSET SHELL C - STORESUNSET SHELLBUILDING ELEVATIONS 1/4" = 1'-0"1FRONT ELEVATION - SUNSET 1/4" = 1'-0"2LEFT SIDE ELEVATION NE 10TH STREET 1/4" = 1'-0"3RIGHT SIDE ELEVATION 1/4" = 1'-0"4REAR ELEVATIONKEYNOTES:ASIGNAGE BY SIGN CONTRACTOR (UNDER SEPERATE PERMIT)BALUMINUM STOREFRONT SYSTEM CLEAR TRANSPARENT GLASS TEMPEREDC6x8 P.T. COLUMNSDEXTERIOR RATED GOOSENECK LED DOWNLIGHTEOPTIONAL - AUTOMATIC BI-PARTING ENTRANCE DOORS.FP.T. TRELLIS OR METAL WRAPPED W/ 10 MIL. TEMPERED GLAZING AWNING - BEHR PPU24-1 BLACK MOCHA FLATGCONCRETE SIDEWALKHPAINTED CMU (RALF LAUREN SPECIALTY (SU62 DIEGO))IMETAL TRELLIS W/ WALL APPROVED CLIMBING GREENJNEW PAINTED 4x8 SMOOTH FIBER CEMENT HARDIE W/ VINYL REGLETON/ RAINSCREEN - PER MANUFACTURERS INSTALLATION GUIDELINES -COLOR (VALSPAR 318-3 (DRIED MOSS))KNEW HORIZNTAL CERTAINTEED MONOGRAM 5" DUTCHLAP W/RAINSCREEN - PER MANUFACTURERS INSTALLATION GUIDELINES -COLOR TERRA COTTAL3-COAT STUCCO - (DUNN EDWARDS (DE5492) SILVER FERN)MPREFABRICATED TERRA COTTA PLANT POTSNMETAL COPING - BEHR PPU24-1 BLACK MOCHA FLATOCOMPOSITION ROOFING - INSTALL PER MANUFACTURER'SRECOMMENDATIONSNOTES:DOORS SHALL BE READILY OPENABLE FROM THE EGRESSSIDRE WITHOUT THE USE OF A KEY OR ANY SPECIALKNOWLEDGE OR EFFORT.IN A3, B,F, M AND S OCCUPANCIES, KEY LOCKING HARDWAREMAY BE USED AT THE MAIN ENTRY DOORS, PROVIDE A SIGN INCONTRASTING LETTERS OF 1 INCH OR MORE IS PROVIDED ATTHE DOORS STATING: "THIS DOORTO REMAIN LOCKED WHENOCCUPIED".PROVIDE TWO LAYERS OF GRADE D PAPER OVER ALL WOODBASE SHEATHING.MAXIMUM EFFORT TO OPERATE DOORS SHALL NOT EXCEED 5POUNDS FOR EXTERIOR AND INTERIOR DOORS, SUCH PULL ORPUSH EFFORT BEING APPLIED AT RIGHT ANGLES TO HINGEDDOORS AND AT THE CENTER PLANE OF SLIDING OR FOLDINGDOORS. COMPENSATING DEVICES OR AUTOMATIC DOOROPENERS MAY BE UTILIZED TO MEET THE ABOVE STANDARDS.WHEN FIRE DOORS ARE REQUIRED, THE MAXIMUM EFFORT TOOPERATE THE DOOR MAY BE INCREASED TO THE MINIMUMALLOWABLE BY THE APPROPRIATE ADMINISTRATIVEAUTHORITY, NOT TO EXCEED 15 POUNDS.ALL BUILDING ENTRANCES THAT ARE ACCESSIBLE TO ANDUSABLE BY PERSONS WITH DISABILITIES SHALL BE IDENTIFIEDWITH AT LEAST ONE STANDARD SIGN AND WITH ADDITIONALDIRECTIONAL SIGNS, AS REQUIRED, TO BE VISIBLE TOPERSONS ALONG APPROACHING PEDESTRIAN WAYS.THE BOTTOM 10 INCHES OF ALL DOORS TO HAVE A SMOOTHUNINTERRUPTED SURFACE TO ALLOW THE DOOR TO BEOPENED BY A WHEELCHAIR FOOT REST WITHOUT CREATING ATRAP OR HAZARDOUS CONDITION.Revision ScheduleRevisionNumberRevision Description RevisionDate1 Revision 1 Date 1