HomeMy WebLinkAboutP_Floor_Plan_Proposed_170621_v12' - 0"66' - 3 1/2"8" 32' - 4"2' - 6"6' - 0"2' - 6"11' - 0" 22' - 0"WALK-IN COOLER - PER OWNER'S SPECIFICATIONSOFFICECASHIERMAX. WORKHEIGHT 34" MAX.(32" PREFERRED)STORAGE/PREPFOUNTAINw/ FLOOR SINKUNDERHWT MODEL -RHEEM ELD52(50 GAL.)COFFEECONDIMENTSUNISEXEQUIPMENT/CONTROLROOM7' - 1"8' - 9"33' - 0"8"2' - 4" 8"11' - 0"2' - 6" 8' - 6" 2' - 6"13' - 6" 11' - 11 1/2" 18' - 2 1/2" 10' - 5 1/2" 13' - 6"2' - 6" 8' - 6" 2' - 6"2' - 0"2' - 0"20' - 4"20' - 4"7' - 6 1/2"10' - 6 1/2" 3 1/2" 14' - 11 1/2"3' - 8 1/2" 6' - 7 1/2"8' - 3 1/2" 3' - 0"8"31' - 0"WALL VINES ONMETAL TRELLIS(TYPICAL U.N.O.)24" WIDEPLANTER PERELEVATIONSRETAIL30" GATEDR.MERCHANDISE RACKSREATIL COUNTER ANDALL APPLIANCES SHALLCOMPLY WITH A11.7SECTION 606 (ADA)8x8 R.S.POSTTYPICALTERRA COTTA POTPLANTERSURROUND POST11.40008.41508.41008.41008.41008.41008.41005.50010.44310.44310.44310.4437' - 8"1" 3' - 4"9' - 11 1/2"02.752D1D2D3D3D3A5.02A5.01A5.03A5.0411111112222WALL MOUNTUNDERGROUND TANKMONITORING SYSTEMPANEL1CLEARLY MARKEDEMERGENCY PUMPSHUT OFF SWITCH1PLANTER WITHDROUGHT TOLERANT 2.5GAL. JAPANESEBOXWOOD PLANTS1113 COMPARTMENTSINKHAND SINKMOP SINKFIBER REINFORCED PANELMARLITE - STANDARDENTIRE STORAGE/PREP WALL(S)SUPPLYINSTAHOTEVERHOTMOUNTAINPLUMBINGMODEL -MT641UNDERGROUND TANK MONITORINGSYSTEM PANEL - CONTRACTORSHALL SUBMIT AND APPLY FOR ASEPERATE PERMIT FROM THE CITYOF RENTON WITH APPROVAL PRIORTO INSTALLATION1EXTERIORINTERIOR7/8" CEMENT BOARD5/8" SHEATHING2x6 WOOD STUD5/8" TYPE 'X' GYP.WALL BOARDG. MerkelMarch 29 - 20171603 116TH Ave NESheetDate:Drawn By:Scale:Client:Suite 115Bellevue, WA 980041B17001464APRIL 24/2017As indicatedA2.02800 NE SUNSET BLVD RENTON, WA 98056RENTON SUNSET SHELL C - STORESUNSET SHELLFLOOR PLAN AND NOTES 1/4" = 1'-0"2CONSTRUCTION FLOOR PLANGENERAL NOTES:A.DIMENSION LINES ARE FROM FACE OF FRAMING ORFOUNDATION UNLESS NOTED OTHERWISE.B.FACE OF FRAMING ON EXTERIOR WALL SAME ASOUTSIDE FACE OF FOUNDATION WALL.C.METAL STUDS MAYBE USED IN PLACE OFWOOD STUDS. PLAN DIMENSIONS ARE BASED ONWOOD STUDS.D.MOISTURE RESISTANT GYPSUM TO BE USEDIN TOILETROOM(S), BEHIND MOP SINK AND,ADJACENT TO COOLERS.FORSPECIFIC SUBSTRATEREQUIREMENTS,REFERTO INTERIOR ELEVATIONS.E.PROVIDE BLOCKING AS REQ'D FOR ALL EQUIPMENT ANDACCESSORIES.F.PROVIDE CLEAR SILICONE SEALANT FOR ALL WALLTRANSITIONS, REFER TO CONSTRUCTION DETAILSATTACHMENT TO ALL WALLS TO STRUCTURE ABOVE.G.FOR FLOORING LAYOUT REFER TO SHEET A2.1H.FOR CEILING LAYOUT REFER TO SHEET A2.1I.FOR FINISH MATERIAL REFER TO INTERIOR SHEET(S)J.INTERIOR GRAPHIC ELEVATIONS (BY OWNER)K.FOR DOOR AND WINDOW DETAILS REFER TO ELEVATIONSL.FOR EQUIPMENT PLAN REFER TO SHEET A3.0M.FOR EQUIPMENT SCHEDULE (BY MECHANICALCONTRACTOR)N.ALL MATERIALS AND APPLICATION TO MEET OR EXCEEDLOCAL OR STATE REQUIREMENTS.O.FOR DOOR SCHEDULE & ELEVATIONS REFER TOSHEET A3.1KEYNOTES:02.752SLOPE SIDEWALK AWAY FROM DOOR/BUILDING 1/8"/FOOT.03.480SCREEN WALL & TRELLIS ABOVE05.500FACADE COLUMNS08.410ALUMINUM ENTRANCE AND STOREFRONT SYSTEM.REFER TO SHEET A5.1 AND SPECIFICATIONS.08.415OPTIONAL - AUTOMATIC BI-PARTING ENTRANCE DOORS.09.260CLEAR PLASTIC CORNER GUARDS.10.442PORTICO COLUMNS10.443PLANT TRELLIS11.005RECESSED KNOXBOX. INSTALL PER MANUFACTURERS SPECIFICATIONS.11.400FOR COOLER AND FREEZER INFORMATION AND DIMENSIONS, REFER TO MANUFACTURER SHEETS.11.401MAINTAIN A MINIMUM 1" AIR GAP BEHIND COOLERS AND FREEZERS ADJACENT TO WALLS. CLOSE SPACE AT ENDS WITH 2"x2" ALUMINUM ANGLE.WALL LEGEND:WOOD FRAMED WALL2x6 STUDS @ 16" o.c. w/ THERMAL INSULATION2x4 STUDS @ 16" o.c.2x4 STUDS @ 16" o.c. w/ SOUND BATT INSULATIONINSULATED WALLPREFABRICATED COOLER123NOTES:DOORS SHALL BE READILY OPENABLE FROM THE EGRESSSIDRE WITHOUT THE USE OF A KEY OR ANY SPECIALKNOWLEDGE OR EFFORT.IN A3, B,F, M AND S OCCUPANCIES, KEY LOCKING HARDWAREMAY BE USED AT THE MAIN ENTRY DOORS, PROVIDE A SIGN INCONTRASTING LETTERS OF 1 INCH OR MORE IS PROVIDED ATTHE DOORS STATING: "THIS DOORTO REMAIN LOCKED WHENOCCUPIED".PROVIDE TWO LAYERS OF GRADE D PAPER OVER ALL WOODBASE SHEATHING.MAXIMUM EFFORT TO OPERATE DOORS SHALL NOT EXCEED 5POUNDS FOR EXTERIOR AND INTERIOR DOORS, SUCH PULL ORPUSH EFFORT BEING APPLIED AT RIGHT ANGLES TO HINGEDDOORS AND AT THE CENTER PLANE OF SLIDING OR FOLDINGDOORS. COMPENSATING DEVICES OR AUTOMATIC DOOROPENERS MAY BE UTILIZED TO MEET THE ABOVE STANDARDS.WHEN FIRE DOORS ARE REQUIRED, THE MAXIMUM EFFORT TOOPERATE THE DOOR MAY BE INCREASED TO THE MINIMUMALLOWABLE BY THE APPROPRIATE ADMINISTRATIVEAUTHORITY, NOT TO EXCEED 15 POUNDS.ALL BUILDING ENTRANCES THAT ARE ACCESSIBLE TO ANDUSABLE BY PERSONS WITH DISABILITIES SHALL BE IDENTIFIEDWITH AT LEAST ONE STANDARD SIGN AND WITH ADDITIONALDIRECTIONAL SIGNS, AS REQUIRED, TO BE VISIBLE TOPERSONS ALONG APPROACHING PEDESTRIAN WAYS.THE BOTTOM 10 INCHES OF ALL DOORS TO HAVE A SMOOTHUNINTERRUPTED SURFACE TO ALLOW THE DOOR TO BEOPENED BY A WHEELCHAIR FOOT REST WITHOUT CREATING ATRAP OR HAZARDOUS CONDITION.FIRE RESISTANT RATED CONSTRUCTION NOTES:FIRE WALLS SHALL COMPLY WITH THE PROVISIONS OF IBC 705.A.WALLS SHALL HAVE SUFFICIENT STRUCTURAL STABILITY UNDER FIRECONDITIONS TO ALLOW COLLAPSE OF CONSTRUCTION ON EITHER SIDEWITHOUT COLLAPSE OF THE WALL FOR THE DURATION OF TIME BY THEFIRE-RESISTANCE RATING.B.FIREWALLS SHALL HAVE A FIRE-RESISTANCE RATING OF NOT LESS THAN REQUIRED BY TABLE 706.4. OPENINGS IN FIRE WALLS SHALL BEPROTECTED IN ACCORDANCE WITH IBC SECTION 716 AND SHALL NOTEXCEED 120 SQUARE FEET. THE AGGREGATE WIDTH OF OPENINGS ATANY FLOOR LEVEL SHALL NOT EXCEED 25 PERCENT OF THE LENGTH OF THE WALL.EXCEPTIONS:1. OPENING NOT PERMITTED IN PARTY WALLS CONSTRUCTEDIN ACCORDANCE WITH IBC 706.1.12. OPENING SHALL NOT BE LIMITED TO 120 SQUARE FEET WHERE BOTH BUILDINGS ARE EQUIPED THROUGHOUT WITHAN AUTOMATIC SPRINKLER SYSTEM INSTALLED PER IBC 903.3.1.1C.FIRE WALLS SHALL EXTEND HORIZONTALLY TO THE OUTER EDGES OFHORIZONTAL PROJECTING ELEMENTS SUCH AS BALCONIES, ROOF OVERHANGS, CANOPIES, MARQUES AND SIMILAR PROJECTIONS THATARE WITHIN 4 FEET OF THE FIREWALL (IBC 706.5.2)D.FIRE WALLS SHALL EXTEND VERTICALLY FROM FOUNDATION TO A POINT 30 INCHES ABOVE ROOF. SEE EXCEPTIONS 1 THROUGH 4 (IBC 706.6).E.BUILDINGS OF TYPE III, IV AND V CONSTRUCTION, FIRE WALLS SHALL BEPERMITTED TO TERMINATE AT THE UNDERSIDE OF COMBUSTIBLE ROOF SHEATHING OR DECKS PROVIDED IN IBC 706.6, EXCEPTIONS 4.4.1,4.4.2 AND 4.4.3FIRE-RESISTANCE JOINT SYSTEMS SHALL COMPLY WITH THE PROVISIONS OF IBC714. JOINTS INSTALLED IN OR BETWEEN FIRE-RESTISTANCE-RATED WALLS, FLOOROR FLOOR/CEILING ASSEMBLIES AND ROOFS OR ROOF/CEILING ASSEMBLIESSHALL BE PROTECTED BY AN APPROVED FIRE-RESISTANT JOINT SYSTEMDESIGNED TO RESIST THE PASSAGE OF FIRE FOR A TIME PERIOD NOT LESS THANTHE REQUIRED FIRE RESISTANCE RATING OF THE WALL, FLOOR OR ROOF IN ORBETWEEN WHICH IT IS INSTALLED.STRUCTURAL MEMBER AND ASSEMBLIES SHALL HAVE A FIRE-RESISTANCE RATINGOF NOT LESS THAN THE RATING REQUIRED FOR THE FIRE RESISTANCE RATEDASSEMBLIES SUPPORTED.PROTECTION OF COLUMNS, GIRDERS, TRUSSES, BEAMS, LINTELS OR OTHERSTRUCTURAL MEMBERS THAT ARE REQUIRED TO HAVE A FIRE-RESISTANCERATING SHALL COMPLY WITH THIS SECTION.IN COMBUSTIBLE CONSTRUCTION, DRAFT STOPS SHALL BE INSTALLED TOSUBDIVIDE ATTICS, MANSARDS, OVERHANGS IN LOCATIONS PRESCRIBED IN IBC718.4.2 THROUGH 718.4.3 3" = 1'-0"1EXTERIOR FIRE WALL DETAIL1A4.0Revision ScheduleRevisionNumberRevision Description RevisionDate1 Revision 1 Date 1