HomeMy WebLinkAboutR-427704DocuSign Envelope ID: 6EECF5B6-602A-4E4A-B436-A317AA638878 DocuSign Envelope ID: 6EECF5B6-602A-4E4A-B436-A317AA638878 DocuSign Envelope ID E212B987-C626-4330-A5D4-DO55AO107AF9 DocuSign Envelope ID: 6EECF5B6-602A-4E4A-B436-A317AA638878 Im FRAME AND VANED GRATE LA �b S- �, •. Y, 1'. 8-, 1 T, OR 24" ONE 43 BAR HOOP FOR W HEIGHT INCREMENT (SPACED EQUALLY), SEE NOTE / RECTANOULAR ADJUSTMENT SECTION NOtti6 7G C Olt 0: 43 BAR EACH CORNER �"OTFa, 43 BAR EACH SIDE 7✓ 43 BAR EACH WAY PRECAST BASE SECTION 43 BAR HOOP 43 BAR EACH CORNER 1B• MIN SEE NOTE I ALTERNATIVE PRECAST BASE SECTION VRIPUBLIC WORKS DEPARTMENT PIPE ALLOWANCES MAXIMUM PIPE MATERIAL INSIDE DIAMETER REINFORCED OR PLAIN CONCRETE I' ALL METAL PIPE 1 `� CPSSP-. lr STD. SPEC. 9-05,20 SOLID WALL PVC, STD SPEC. 9-05.120 ) 15' PROFILE WALL PVC. SPEC. 9.05.12(2) is,STD ' CORRUGATED POLYETHYLENE STORM SEWER PIPE NOTES: I. AS ACCEPTABLE ALTERNATIVES TO THE REBAR SHOWN IN THE PRECAST BASE SECTION, FIBERS (PLACED IN ACCORDANCE WITH STANDARD SPECIFICATION 9-05.50(9)), OR WIRE MESH HAVING A MINIMUM AREA OF 0.,2 SQUARE INCHES PER FOOT SHALL BE USED WITH THE MINIMUM REQUIRED REBAR SHOWN IN THE ALTERNATIVE PRECAST BASE SECTION. WIRE MESH SHALL NOT BE PLACED IN THE KNOCKOUTS AS AN ACCEPTABLE ALTERNATIVE TO THE REBAR SHOWN IN THE RECTANGULAR ADJUSTMENT SECTION, WIRE MESH HAVING A MINIMUM AREA OF 0.12 SQUARE INCHES PER FOOT MAY BE USED 2. THE KNOCKOUT DIAMETER SHALL NOT BE GREATER THAN 20' KNOCKOUTS SMALL HAVE A WALL THICKNESS OF 2• MINIMUM T025' MAXIMUM PROVIDE A 1 5- MINIMUM OAP BETWEEN THE KNOCKOUT WALL AND THE OUTSIDE OF THE PIPE AFTER THE PIPE IS INSTALLED, FILL THE GAP WITH JOINT MORTAR IN ACCORDANCE WITH STANDARD SPECIFICATION 9-04.3. 3, THE MAXIMUM DEPTH FROM THE FINISHED GRADE TO THE LOWEST PIPE INVERT SHALL BE 5 FEET 4. THE FRAME AND GRATE MUST BE INSTALLED WITH THE FLANGE DOWN S. THE PRECAST BASE SECTION MAY HAVE A ROUNDED FLOOR, AND THE WALLS MAY BE SLOPED AT A RATE OF 1 H:24V OR STEEPER. 8, THE OPENING SHALL BE MEASURED AT THE TOP OF THE PRECAST BASE SECTION, 7, ALL PICKUP HOLES SHALL BE GROUTED FULL AFTER THE INLET HAS BEEN PLACED. USE GROUT TYPE 2 FOR NON -SHRINK APPLICATIONS IN ACCORDANCE WITH STANDARD SPECIFICATION 9.20.3(2) S. ALL GRADE RINGS AND CASTINGS SHALL BE SET IN MORTAR IN ACCORDANCE WITH STANDARD SPECIFICATION 9-04 3 THEN APPLY MORTAR TO INSIDE AND OUTSIDE OF ALL JOINTS. RINGS. RISERS. AND FRAMES. 9, MORTAR SHALL BE MIXED AND APPLIED PER MANUFACTURERS DIRECTIONS. 10. FRAME SHALL BE ADJUSTED TO PAVEMENT GRADE BY TAPPING UNTIL FRAME IS FLUSH WITH PAVEMENT AS DETERMINED WITH A STRAIGHT EDGE OF SUFFICIENT LENGTH 11. ALL MORTAR JOINTS SHALL BE TRIMMED FLUSH AND REMAIN VISIBLE UPON COMPLETION, UNLESS OTHERWISE NOTED, DRAWING IS NOT TO SCALE (WSJ STD. PLAN - 200.00 APPR CATCH BASIN TYPE 1 GAZ 9/28/2018 I DATE DocuSign Envelope ID: 6EECF5B6-602A-4E4A-B436-A317AA638878 24- A 2 112' DIA. HOLE Q� apapOp QQO�a�a C'�QG�p��OQ a�0� papa TOP m BOLT -DOWN SLOT, SEE DETAIL AND NOTE I ISOMETRIC � 4 314- 1 1? T 15 *+ R39', SEE NOTE 2 SECTION A SEE NOTE I SECTION 8 JAM. SEE NOTE 2 5- NOTES: 4- 1 BOLT -DOWN CAPABILITY IS REQUIRED ON ALL FRAMES, GRATES. AND COVERS. UNLESS OTHERWISE SPECIFIED. 1 yg• PROVIDE TWO HOLES IN THE FRAME THAT ARE j VERTICALLY ALIGNED WITH THE GRATE OR COVER SLOTS THE FRAME SHALL ACCEPT THE SIB'-11 NC x 2• ALLEN 4" HEAD CAP SCREW BY BEING TAPPED, OR OTHER I(r 341• DIA. HOLE APPROVED MECHANISM. LOCATION OF BOLT -DOWN HOLES VARNI IES BY MANUFACTURER. I? DIA HANDLE 1112, 2 ALTERNATIVE REINFORCING DESIGNS ARE ACCEPTABLE IN SECTION c LIEU OF THE RIB DESIGN 3. REFER TO STANDARD SPECIFICATION 9.05.15(2) FOR ADDITIONAL REQUIREMENTS 4. FOR FRAME DETAILS, SEE CITY OF RENTON STANDARD PLAN 204.00. UNLESS OTHERWISE NOTED. DRAWING IS NOT TO SCALE (NTS) URIPUBLIC WORKS DEPARTMENT RECTANGULAR SOLID METAL COVER��2018 STD. PLAN - 204.20 I DATE TEBALDI ENGINEERING, LLC PO BOX 121 SUMNER, WA 98390 (206) 450-5096 :45 Al :45 Aq III 'III IIA CLEAN SURFACE AND BOTTOM AREA PROVIDE UNIFORM CONTACT. THE SURFACE AREA OF THE BASE SECTION MUST BE MORTARED TO THE BOTTOM AREA OF THE ADJUSTMENT SECTION ADJUSTMENT SECTION I I I I I I I BASE SECTIOH pam-mrmr-mrrrr. NOTES: 1 THE COVER OR GRATING OF A CATCH BASIN SHALL NOT BE ADJUSTED TO FINAL GRADE UNTIL THE FINAL ELEVATION OF THE PAVEMENT, GUTTER, DITCH, OR SIDEWALK IN WHICH IT IS TO BE PLACED HAS BEEN ESTABLISHED. AND UNTIL PERMISSION THEREAFTER IS GIVEN BY THE ENGINEER TO MORTAR IN PLACE I N ACCORDANCE WITH WSDOTIAPWA STANDARD SPECIFICATION 7.05.3. 2- SHIMS SHALL NOT BE USED TO SET FRAME TO GRADE THE USE OF SHIMS IS PROHIBITED. 3. A CONTINUOUS LAYER OF MORTAR SHALL BE PLACED BETWEEN ADJUSTMENT RINGS AND BRICKS PRIOR TO PLACEMENT, 4 ONLY BY APPROVAL OF THE CITY, THE USE OF BRICKS IS PERMITTED WHERE THE BRICKS ARE STAGGERED TO CREATE A. RUNNING BOND OR X• BOND. 5. BASE SECTION SMALL BE SEALED TO THE BOTTOM AREA OF THE ADJUSTMENT SECTION WITH MORTAR 6 MORTAR SHALL MEET THE REQUIREMENTS OF WSDOT/APWA STANDARD SPECIFICATION 9-04.3 7 PICK 1 LIFTING HOLES ARE TO BE GROUTED WATER TIGHT. USE GROUT TYPE 2 FOR NON -SHRINK APPLICATIONS IN ACCORDANCE WITH STANDARD SPECIFICATION 9.20 3J2L 8. MORTAR SHALL BE MIXED AND APPLIED PER MANUFACTURERS DIRECTIONS. 9. FRAME SHALL BE ADJUSTED TO PAVEMENT GRADE BY TAPPING UNTIL FRAME IS FLUSH WITH PAVEMENT AS DETERMINED WITH A STRAIGHT EDGE OF SUFFICIENT LENGTH_ 10 ALL MORTAR JOINTS SHALL BE TRIMMED FLUSH AND REMAIN VISIBLE UPON COMPLETION. UNLESS OTHERWISE NOTED, DRAWING IS NOT TO is A'J ,Nr STD. PLAN - 202.00 PUBLIC WORKS CATCH BASIN INSTALLATION DEPARTMENT GAZ 9/28/2018 I DATE DocuSign Envelope ID 6EECF5B6-602A-4E4A-B436-A317AA638878 �u G� FLOW a OVTFALL TO 8T11FAY ,' OUw NO'OLLUTANTB BOLT -DOWN SLOT 1 17 SEE DETAIL AND NOTE 1314 I I 1 iN' �I }I 1 BOLT -DOWN SLOT DETAIL JLE � ulL' TOP m /\ 'UI• RFl:FCCFO I FTTFRMJf: ISOMETRIC -x r SECTION B NOTES: 1. BOLT -DOWN CAPABILITY IS REQUIRED ON ALL FRAMES. GRATES. AND COVERS, UNLESS OTHERWISE SPECIFIED PROVIDE TWO HOLES IN THE FRAME THAT ARE VERTICALLY ALIGNED WITH THE GRATE OR COVER SLOTS. THE FRAME SHALL ACCEPT THE 518'-1I NO It 2' ALLEN HEAD CAP SCREW BY BEING TAPPED, OR OTHER APPROVED MECHANISM. LOCATION OF BOLT -DOWN HOLES VARIES BY MANUFACTURER. 2 REFER TO STANDARD SPECIFICATION 8.05.1S(2) FOR ADDITIONAL REQUIREMENTS _ 'OR FRAME DETAILS. SEE STANDARD PLAN 204.00. UNLESS OTHERWISE NOTED. DRAWING IS NOT TO SCALE (WSJ STD. PLAN - 204.20 PUBLIC WORKS DEPARTMENT RECTANGULAR VANED GRATE GAZ 9/28/2018 1 DATE �5 M. TF WAWASA 43524 Fs F01 STERN s/DNA L ECG 2/12/24 3 1 REVISED PER CITY COMMENTS 2 REVISED PER CITY COMMENTS 1 REVISED PER CITY COMMENTS NO. REVISION :4S Al :45 AM 25 I: C' _ 29 I r BOLT -DOWN HOLE (TYP.1 11 NC. SEE DETAIL AND NOTE 2 _/ TOP RECESSED A' F HEAD CAP SCREW SIN' - I I "I It 2` ORATE FRMIE SECTION BOLT -DOWN DETAIL SEE NOTE 2 24 114"<> SECTION A SEIE DETAIL - ISOMETRIC VIEW I +i 1fB' �3W \ 1114• J NOTES: 1 THIS FRAME IS DESIGNED TO ACCOMMODATE 2(r • 24• GRATES OR COVERS. I 4 1? SEE STANDARD PLANS 204 10. 204.20, AND 20430, 1 5/8' I 2 BOLT-0OWN CAPABILITY IS REQUIRED ON ALL FRAMES GRATES, AND COVERS. UNLESS OTHERWISE SPECIFIED. PROVIDE TWO HOLES IN THE L 1 y8. I FRAME THAT ARE VERTICALLY ALIGNED WITH THE GRATE OR COVER SLOTSTHE FRAME SHALL ACCEPT THE SV�l I NC x r ALLEN HEAD CAP 3N' + / BEING TAPPED, OR OTHER APPROVED MECHANISM. LOCATION OFCREIN BY / BOLT -DOWN HOLES VARIES BY MANUFACTURER \ [-- 2 UL' 3 REFER TO STANDARD SPECIFICATION 9.05 15(2) FOR ADDITIONAL \ DETAIL REQUIREMENTS UNLESS OTHERWISE NOTED, DRAWING IS NOT TO SCALE ',NTyi STD. PLAN - 204.00 PUBLIC WORKS APPROVED�w U DEPARTMENT RECTANGULAR FRAME MaEUnPastucha 10/19/2022 1 rr AwwAl.ls DATE DocuSign Envelope ID 6EECF5B6-602A-4E4A-B436-A317AA638878 JOINTS IN FILTER FABRIC SHALL BE SPLICED AT POSTS. USE STAPLES, WIRE RINGS, OR EQUIVALENT TO ATTACH FABRIC TO POSTS 41 1 _ n2. 14 GAUGE WIRE, OR p EQUIVALENT. IF STANDARD STRENGTH FABRIC USED FILTER FABRIC --I�-----------J�- I�- F. MAX I POST SPACING MAY BE INCREASED q•xq• MIN, TRENCH J r/ TO 8' IF WIRE BACKING IS USED I I .' 1-II ORSACKF1314'LT TRENCH WITH NAIVE SOIL t OR 314' TO 1-1? WASHED GRAVEL TxV WOOD POSTS, STEEL FENCE POSTS, OR EQUIVALENT (TYP I NOTES: 1. CONDITIONS OF USE 1,1 SILT FENCE MAY BE USED DOWNSLOPE OF ALL DISTURBED AREAS. 1.2. SILT FENCE IS NOT INTENDED TO TREAT CONCENTRATED FLOWS, NOR IS IT INTENDED TO TREAT SUBSTANTIAL AMOUNTS OF OVERLAND FLOW. ANY CONCENTRATED FLOW MUST BE CONVEYED THROUGH THE DRAINAGE SYSTEM TO A SEDIMENT TRAP OR POND L DESIGN AND INSTALLATION SPECIIFICATK INS 2,1 THE GEOTEXTILE USED MUST MEET THE STANDARD LISTED BELLOW A COPY OF THE MANUFACTURERS FABRIC SPECIFICATIONS MUST BE AVAILABLE ON SITE ADS (ASTM 04751) 30-100 SIEVE SIZE (0.6D0 15(m) FOR SILT FILM 50-IOD SIEVE SIZE (D.30-0 15-) FOR OTHER FABRICS WATER PERMITTIVITY (ASTM D44911 0.02 SEC' MINIMUM GRAB TENSILE STRENGTH JASTM D4832) 180 CBS MIN FOR EXTRA STRENGTH FABRIC 100 CBS MIN FOR STANDARD STRENGTH FABRIC GRAB TENSILE ELONGATION(ASTM D4832) 30% MAX (WOVEN I ULTRAVIOLET RESISTANCE (ASTM 134355) 70% MIN. 2.2. STANDARD STRENGTH FABRIC REQUIRES WIRE BACKING TO INCREASE THE STRENGTH OF THE FENCE WIRE BACKING OR CLOSER POST SPACING MAY BE REQUIRED FOR EXTRA STRENGTH FABRIC IF FIELD PERFORMANCE WARRANTS A STRONGER FENCE Z3. WHERE THE FENCE IS INSTALLED, THE SLOPE SHALL NOT BE STEEPER THAN 2MAV 2 4. IF A TYPICAL SILT FENCE IS USED, THE STANDARD 4'X4• TRENCH MAY BE REDUCED AS LONG AS THE BOTTOM 81NCHES OF THE SILT FENCE FABRIC IS WELL BURIED AND SECURE IN A TRENCH THAT STABILIZES THE FENCE AND DOES NOT ALLOW WATER TO BYPASS OR UNDERMINE THE SILT FENCE 2.5. FILTER FABRIC FENCES SMALL BE INSTALLED ALONG CONTOURS WHENEVER POSSIBLE. 3. MAINTENANCE STANDARDS 3.1. ANY DAMAGE SHALL BE REPAIRED IMMEDIATELY 3.2 IF CONCENTRATED FLOWS ARE EVIDENT UPHILL OF THE FENCE. THEY MUST BE INTERCEPTED AND CONVEYED TO A SEDIMENT TRAP OR POND 3.3. IT IS IMPORTANT TO CHECK THE UPHILL SIDE OF THE FENCE FOR SIGNS OF THE FENCE CLOGGING AND ACTING AS A BARRIER TO FLOW AND THEN CAUSING CHANNELIZATION OF FLOWS PARALLEL TO THE FENCE. IF THIS OCCURS, REPLACE THE FENCE OR REMOVE THE TRAPPED SEDIMENT 3A SEDIMENT MUST BE REMOVE D WHEN SEDIMENT IS 6 INCHES HIGH 3,5 IF THE FILTER FABRIC (GEOTEXTILE) HAS DETERIORATED DUE TO ULTRAVIOLET BREAKDOWN. IT SHALL BE REPLACED. UNLESS OTHERWISE NOTED. DRAWING IS NOT TO SCALE (WS) STD. PLAN - 214.00 PUBLIC WORKS SILT FENCE 9/28/2018 1 -0 DEPARTMENT [II GAZ rw•wen xa...u..a DATE B AB LAND SURVEY IIOKa N/A Cw CMT 2/12/24 CMT CMT 11/25 CMT ° ` CmT als Nox � P > f NOr qt Mox CMT 10/21 CMT a■amII CHAT BY DATE APPR 2:52 :45 All CATCH BASIN FRAME AND VANED GRATE PER STD PLAN 204.00 RECTANGULAR OR CIRCULAR ADJUSTMENT SECTION (TWO SECTIONS MAXI MORTAR, (TYP. I. SEE NOTE 5 4' MN. 2W MAX. IW MAX. FLAT SLAB TOP 48', 54'. 60'. 72". B4•. 96", 12D' OR 144" SEE NOTE 6 TYP 1S MAX FOR MAINTENANCE STEPS OR LADDER L- 12'(TYP1 J=r_RF.�I.fl "O" RING' 24' 25' MAFORCING STEEL (TYP.) MIN 12• GRAVEL BACKFILL FOR PIPE ZONE BEDDING PER WSDOT STD. SPECIFICATION SECTION 9-03, 12(3) SEPARATE BASE INTEGRAL BASE PRECAST PRECAST WITH RISER NOTES: 'vu STEPS ARE RECIIIRED WHEN HEIGHT IS 4' OR LESS. 2 THE BOTTOM OF THE PRECAST CATCH BASIN MAY BE SLOPED 70 FACILITATE CLEANING. 3 THE RECTANGULAR FRAME AND GRATE MUST BE INSTALLED WITH THE FLANGE DOWN. THE FRAME MAY BE CAST INTO THE ADJUSTMENT SECTION. KNOCKOUTS SHALL HAVE A WALL THICKNESS OF 2- MINIMUM TO 2.5" MAXIMUM- PROVIDE A 1-5' MNIMUM GAP BETWEEN THE KNOCKOUT WALL AND THE OUTSIDE OF THE PIPE AFTER THE PIPE IS INSTALLED, FILL THE GAP WITH JOINT MORTAR N ACCORDANCE WITH STANDARD SPECIFICATION 904.3 5. ALL GRADE RINGS. RISERS. AND CASTINGS SHALL BE SET IN MORTAR IN ACCORDANCE WITH STANDARD SPECIFICATION 904.3 6. WHEN CONNECTING TO A NEW PIPE, USE A FLEXIBLE CONNECTOR (KOR-N-SEAL BOOT WITH CORRUGATED PIPE ADAPTER OR APPROVED EQUAL) WHEN CONNECTING TO AN EXISTING PIPE. USE A FABRICATED SAND COLLAR OF THE SAME MATERIAL AS THE CONNECTING PIPE. MORTAR SHALL BE MIXED AND APPLIED PER MANUFACTURERS DIRECTIONS 8 FRAME SMALL BE ADJUSTED TO PAVEMENT GRADE BY TAPPING UNTIL FRAME IS FLUSH WITH PAVEMENT AS DETERMINED WITH A STRAIGHT EDGE OF SUFFICIENT LENGTH 9. ALL MORTAR JOINTS SHALL BE TRIMMED FLUSH AND REMAIN VISIBLE UPON COMPLETION PUBLIC WORKS DEPARTMENT irum 1 DATU M CATCH BASIN DIMENSIONS CATCH BASIN DIAMETER MN. WALL THICKNESS MIN BASE THICKNESS MAXIMUM KNOCKOUT SIZE MINIMUM DISTANCE BETWEEN KNOCKOUTS 4a• 4' 8' 38' B' 54" 4.5' r 4T 8' 4W 8' 7r 8' S• 80" 12' 84• r 12' 72" 12" 98' S• 12' 84" 12' 120' 10" 12' 98" 12" 12' 108' 12' PIPE ALLOWANCES CATCH BASIN PIPE MATERIAL WITH MAXIMUM INSIDE DIAMETER DIAMETER CONCRETE ALL METAL CPSSP' SOLID WALL PVC F PROFILE WALL PVC' 48" 24" 30" 24' 30" 30' 54' 30' 38" 3D' 36" 36- 60' 36' 42" 36' 4Z' 42• 72" 42' 54' 42' 48" 1 84` 54' 60" 54' 48" 48' 98' 60 7Y W. 48" 48' 12D' BE 84" BO' 48' 48' 144' 1 78` 196" BO` 48" 46' 'CORRUGATED POLYETHYLENE STORM SEWER PIPE ISTD. SPEC. %06.20) 'STD. SPEC 9-0S.1211) F STD. SPEC. 9-05. 12(2) CATCH BASIN TYPE 2 CITY OF RENTON Planning/Building/Public Works Dept. UNLESS OTHERWISE NOTED. DRAWING IS NOT TO SCALE (WSJ STD. PLAN - 201.00 GAZ 9/28/2018 I DATE :45 Al R-427704 IN COMPLIANCE WITH CITY OF RENTON STANDARDS FDEVELOPMENT ENGINEERING yqi 07/10/2024 ' GASPAIRE SFR OFFSITE IMPROVEMENTS NOTES AND DETAIL 39XX NE 6TH STREET 2/4/23 RMOEOOIQ �8oe 4 OF