HomeMy WebLinkAboutM_Response to Comments_180122_v1title company has requested we remove this portion add the following before what you currently have in item #4: single family residences and other improvements constructed on the lots created by the subdivision must implement the flow control best management practices stipulated in the approved drainage study and plans no. 3908 on file with the city of renton as well as any declaration of covenants and grants of easement recorded hereon. compliance with this requirement will be addressed in the drainage plan submitted for residential building permit drainage review when an application is made for a single family residential building permit for each lot. Markup Legend RED Required Revisions BLUE Recommended Revisions PURPLE Advisory Only GREEN Items to be Deleted Done Done EXISTING FIRE HYDRANT HAS NOT BEEN RELOCATED/REPLACED PER APPROVED PLAN. PRIVATE ACCESS ROADWAY NOT INSTALLED OR PAVED. PROVIDE ADDRESS NUMBER SIGN PER CITY STANDARD AT STREET FOR THE TWO HOUSES LOCATED OFF OF LINCOLN AVENUE. add blank spot for recording number for all public utility easements for cross referencing. see suggested revision to the public easements, left. the city strongly prefers that the easements for city water facilities are part of one single recording. this will allow anyone to view all of the public water utility easements for this project in their entirety rather than searching for multiple recordings. this will also reduce recording costs incurred by the city. there are two ways to accomplish this: - rewrite legal descriptions and exhibits to encompass all of the public water utility easements in one description and exhibit. - combine all legal descriptions and exhibits that have been provided into one document for a single recording. either way is acceptable. separate private easements are not required by the city. the private easement provisions shown on sheet 1 of the short plat have been reviewed and are acceptable. the provisions shown on sheet 1 are all that the city requires for recording. if the applicant wishes to record the separate private easements that were submitted as part of the submittal, than the applicant will be responsible for recording them on their own. these easements will not be sent as part of the short plat package to the king county recorder's office from the city. new fire hydrant is now located on private property per approved revision on 11-28-17. provide easement for fire hydrant. the meter location for lot 1 has also been adjusted. ensure the updated easement covers the new meter location. Done, the public esmts were combined into one document Done. When all the meters/FHs/etc are put in we will survey to make sure they match the easements as written Noted, but this isn't part of the final short plat is it?Done Done, the private easements will be created on the short plat map--better dimensions were added