Loading...
HomeMy WebLinkAboutP_Strucural_Plans_and_elevations_171229_v1� J � J p ~ 0 Z NwW0p w�Z3"ZJm�~ 00 �QWWa zOQ ILpO4mupffO Q z W w p�Oww�wc�"`6 pwz�zpzFQu zaQZOJZgplz '6z j):- p z Owp� NLL��N W - w O� Z J J gU-> (D U- NUVOWIAUm ia oQ-wI O .q Ww�iN�QpO �OwQOwz 3,3.4 o o� 09 Twz ° o F- 0- WW000N u z w z o� ops wZwz�Wo9 NQwz 30 u� w 0jmwmiRTOzq m�000�W�WLL KO i?Oz3LL� 0azz0 (Y 0 O l� z 0 U- O z O O z 4 w Z w W W Q p O O D � i-3 w w w ~ Z O O z D � O -1 1: w cn O w W LL O W U w z U � z � W w LL w �- A O LL W W X O W � W �wkn W W ten= PREPARED FOR: PROJECT DATA: PARCEL NO.: PROPERTY TYPE: LAND AREA: ACRES: Q,5,T,R: ADDRESS: ZONE: SETBACKS: HEIGHT: MAX. BUILDING COVERAGE IMPERVIOUS COVERAGE: 334390-2564 (LOT 3) R, RESIDENTIAL 5,581 sq, ft. 0.13 5E-5-23-5 1814 NE 13TH ST. RENTON, WA 98056 (CURRENT) R -S FRONT: 15 FEET REAR: 20 FEET SIDE: 5 FT. MIN. 24' MAX, WALL PL. HEIGHT 55% 65io LEGAL DESCRIPTION: HILLMANS LK WN GARDEN OF EDEN 04 LOT 3 OF CITY OF RENTON SP# LUA13-0001128 REG# 20161020900001 SD SP BEING LOC IN LOTS 268 & 288 OF 5D ADD Plat Block: Plat Lot: 268 DESIGN TEAM: STRUCTURAL ENGINEER: BUILDER: URBAN DESIGN GROUP 819 RAINIER AVE N SUITE: 4200 RENTON, WA 98051 120(o) 838-8250 CONTACT: PAVEL MELNIK pa vel eurbandes igns.us NN ENGINEERING P.O. BOX 39681 LAKEWOOD, WA 98496 TEL: (253) 250-6651 CONTACT: NORM P. NAVARRO nneng ineer ing egma i I.ccm EXCEPTIONAL NUJ I-IOMES, LLC 5/003 SE 2ND CT, RENTON, W,4 `00059 (425) 213-8531 CONTACT: TYLER WOODBRIDGE t�lerwe jchnlecott.ccm O W w nOn/ 1� 5�4EET N�DEX SKEET # ARCHITECTURAL PLAN COVER 3D RENDERING $ PROPERTY INFORI„IATION Al GENERAL NOTES $ PLAN PREVIEW A2 1-IAIN FLOOR PLAN A3 UPPER FLOOR PLAN ,A-4 ELEVATIONS: FRONT 4 REAR ,45 ELEVATIONS: RIGHT 4 LEFT ,Aro BUILDING CROSS-SECTION 'A' 4 DETAILS Al VENTIALION, GLAZING 4 HEATING SCHEDULES STRUCTURAL ENGINEERING PLAN 51 STRUCTURAL GENERAL NOTES 52 STRUCTURAL DETAILS S3 STRUCTURAL DETAILS 54 FOUNDATION 4 11,41N FLOOR FR,411NG 55 UPPER FLOOR FRAI„IING Sr ROOF FRAMING PLAN BUILDING DEPARTMENT NOTES: L 0 a 0. IL o U 'n O QU �J �J WW U �COc�W WI OQ Z� N �� o2 �� IL o U 'n O C7 �LU o� Z z L7 U) w Q� o Z 0W L� Qiu Z wLU � Q z� m <� V z e Z �LU ,,, Z zz 0W Z Z LUZ V z LU m� z LU � a a o� L �e o N \ 4 N Lu nl N {� ,&I= Project # 17170 COVER N J � J Q DWW "ZTV nQ 'NwtW0O zZ�NQZaIJF� � Wq Wm� Q[L HQ WzOz6 WZC,OgCDu0WO .4 n u� N WN&PF Q-WDO'N IZO-OW N- �7 OT)�~�q'Nnlz� pWz�z=pz1:q Z Cl Q Z O J Z g 6 W(L'q' Z4NJQ� Q z _�:-ZLUCt-,-3. DQ i N w (K z>_LwCLW(LQ�gO� Oz (LWOOZJJMU-> NO=Nw(LJO M ��N04iiN=�OZo zN3Q_lzW9i�Q o OWn~-4 WOWQOzOLLOQzf--o > �W�QwWuZ N Q = N O wOOw�pzopo oZ ons WZW WO WZ NQff�zrz4Do W-Jtu�4' Kz?Q >_mMDO-30520 u -i -i ([1 W I_ 73 Z � U ��fq�G<luPW =zZDFL00QZ N GENERAL NOTES INTERNATIONAL RESIDENTIAL CODE 2015 EDITION AND ALL APPLICABLE CODES AND AUTHORITIES HAVING JURISTICTION TO BE FOLLOWED. 2015 INTERNATIONAL RESIDENTIAL CODE 2015 WASHINGTON STATE ENERGY CODE CONTRACTOR SHALL VERIFY ALL NOTES, DIMENSIONS 4 CONDITIONS PRIOR TO CONSTRUCTION S PROVIDE TEMPORARY BRACING AS REQUIRED UNTIL ALL PERMANENT CONNECTIONS HAVE BEEN INSTALLED. IT IS THE CONTRACTOR'S RESPONSIBILITY TO IDENTIFY REPETITIVE FEATURES NOT NOTED ON THE DRAWINGS SHALL BE COMPLETELY PROVIDED AS IF DRAWN IN FULL CONTRACTOR SHALL VERIFY ALL ROUGH -IN DIMENSIONS FOR ALL EQUIPMENT TO BE INSTALLED 115 1 TE LUOR GENERAL UNLESS A SOILS INVESTIGATION BY A QUALIFIED SOILS ENGINEER IS PROVIDED, FOUNDATION DESIGN IS BASED ON AN ASSUMED AVERAGE SOIL BEARING OF 1500 PSF. EXTERIOR FOOTINGS SHALL BEAR 1'6" (MINIMUM) BELOW FINISHED GRADE. ALL FOOTINGS TO BEAR ON FIRM UNDISTURBED EARTH BELOW ORGANIC SURFACE SOILS. BACK FILL TO BE THOROUGHLY COMPACTED. FOUNDATION VENTS SHALL NOT INTERFERE WITH DIRECT LOAD PATH OF COLUMNS. CONCRETE o MIX AND 2,5 DAY STRENGTH OF CONCRETE U -Factor - BASEMENT WALLS 4 FOUNDATIONS PER 4 OTHER CONCRETE NOT EXPOSED STRUCTURAL TO WEATHER: S -SHEETS - BASEMENT SLABS S INTERIOR SLABS PER 4 INTERIOR SLABS ON GRADE, STRUCTURAL EXCEPT GARAGE DOOR SLABS S -SHEETS - BASEMENT WALLS 4 FOUNDATION PER WALLS, EXTERIOR WALLS 4 OTHER STRUCTURAL VERTICAL CONCRETE WORK EXPOSED S -SHEETS TO THE WEATHER: - PORCHES, CARPORT SLABS 4 STEPS PER EXPOSED TO WEATHER, 4 GARAGE STRUCTURAL FLOOR SLABS: S -SHEETS GARAGE FLOORS TO SLOPE 1/0"/FT. MIN. TOWARDS OPENING AS REQUIRED FOR DRAINAGE. CONCRETE SLABS TO HAVE CONTROL JOINTS AT 25' FT. (MAX.) INTERVALS EA. WAY. SLABS ARE TO BE 5 -AIR ENTRAINED CONCRETE SIDEWALKS TO HAVE 3/4" IN. TOOLED JOINTS AT 5' FT. (MIN.) O.C. CONCRETE COVER OF REINFORCING 3" CONCRETE CAST AGAINST AND PERMANENTLY EXPOSED TO EARTH. 1 1/2" CONCRETE EXPOSED TO EARTH OR WEATHER. 1 1/2" BEAMS AND COLUMNS NOT EXPOSED TO EARTH OR WEATHER. 3/4" SLABS AND WALLS NOT EXPOSED TO EARTH OR WEATHER. LAP COLUMN VERTICALS. CLASS "A" CONCRETE AND MASONRY COLUMN AND WALL VERTICALS 52 DIAMETERS. LAP ALL OTHER REINFORCING 24 DIAMETERS. SPLICES AT TENSION REGIONS SHALL NOT BE PERMITTED. ,4fEIVT � GENERAL ALL FRAMING TO COMPLY WITH ENGINEERING S -SHEETS FOR NAIL SIZES AND SPACING. ALL WOOD IN CONTACT WITH CONCRETE TO BE PRESSURE TREATED. 6" MIN. CLEARANCE BETWEEN WOOD AND EARTH. 18" MIN. CLEARANCE BETWEEN FLOOR JOIST AND EARTH. 12" MIN. CLEARANCE BETWEEN FLOOR BEAMS AND EARTH. FASTENERS FOR PRESSURE PRESERVATIVE AND FIRE-RETANDANT-TREATED WOOD SHALL BE OF NOT -DIPPED GALVANIZED STEEL. REEERENCE 6KEET-S1 FOR SPECIES AND GRADE (5,45E DESIGN VALUES) BOLT HEADS AND NUTS BEARING AGAINST WOOD TO BE PROVIDED WITH 3"X3"X223" PLATE WASHERS. WOOD BEARING ON OR INSTALLED WITHIN 1" OF MASONRY OR CONCRETE TO BE TREATED WITH AN APPROVED PRESERVATIVE. SOLID BLOCKING OF NOT LESS THAN 2 X THICKNESS SHALL BE PROVIDED AT ENDS AND AT ALL SUPPORT OF JOISTS AND RAFTERS. BETWEEN SUPPORTS PROVIDED AT ENDS AND AT ALL SUPPORT OF JOISTS AND RAFTERS, JOISTS, 10'-0" FOR ROOF JOISTS. TYPICAL SILL BOLTS TO BE 5/8" DIAMETER AT 6'-0" O.G. MINIMUM -1" EMBED. ALL METAL FRAMING ANCHORS AND HANGERS SHOWN ON DRAWINGS SHALL BE STRONG TIE CONNECTORS AS MANUFACTURED BY SIMPSON COMPANY. PL T UJOOD PLYWOOD WALL AND ROOF SHEATHING SHALL BE 3/4" CDX, UNLESS OTHERWISE SPECIFIED. PLYWOOD FLOOR SHEATHING SHALL BE 3/4" CDX TBG. UNLESS OTHERWISE SPECIFIED. STAGGER END LAPS AT ROOF AND FLOOR SHEATHING. OSB SHEATHING PRODUCTS OF EQUIVALENT SPAN RATINGS SHALL BE ALLOWED. WOOD TRU55E5 ALL ROOF TRUSSES SHALL BE FRAMED AND TIED INTO THE FRAME WORK AND SUPPORTING WALLS SO AS TO FROM AN INTEGRAL PART OF THE WHOLE BUILDING. ROOF TRUSSES SHALL HAVE JOINTS WELL FITTED AND SHALL HAVE ALL TENSION MEMBERS WELL TIGHTENED BEFORE ANY LOAD IS PLACED UPON THE TRUSS. DIAGONAL AND SWAY BRACING SHALL BE USED TO BRACEALL TRUSSES. 6EE 5I4EET-e1 FOR DE&IGN CRITERIA INESL�LATION SND 11013T�REE FROT CT 1 ON GENE RAL INSULATION BAFFLES TO MAINTAIN I" ABOVE BATT INSULATION BAFFLES TO EXTEND 6" ABOVE BATT INSULATION BAFFLES TO EXTEND 12" ABOVE LOOSE FILL INSULATION INSULATE BEHIND TUBS/SHOWERS, PARTITIONS AND CORNERS FACE STAPLE BATTS FRICTION FIT FACED BATTS USE 4 MIL POLY VAPOR RETARDER AT WALLS. • R-10 RIGID FOAM INSULATION ON 4X EADERS AT EXTERIOR WALLS. INFILTRATION CONTROL 1. EXTERIOR JOINTS AROUND WINDOWS AND DOOR FRAMES, OPENINGS BETWEEN WALLS AND FOUNDATIONS, BETWEEN WALLS AND ROOF AND BETWEEN WALL PANELS, OPENINGS AT PENETRATIONS OF UTILITY SERVICES THROUGH WALLS, FLOOR AND ROOFS, AND ALL OTHER SUCH OPENINGS IN THE BUILDING ENVELOPE, INCLUDING ACCESS PANELS INTO UNHEATED SPACES, SHALL BE SEALED, CAULKED, GASKETED OR WEATHER-STRIPPED TO LIMIT AIR LEAKAGE. ALL OPENINGS SHALL BE FLASHED. APPROVED CORROSION -RESISTIVE FLASHING SHALL BE PROVIDED IN THE EXTERIOR WALL ENVELOPE IN SUCH A MANNER AS TO PREVENT ENTRY OF WATER INTO THE WALL CAVITY OR PENETRATION OF WATER TO THE BUILDING STRUCTURAL FRAMING COMPONENTS. THE FLASHING SHALL EXTEND TO THE SURFACE OF THE EXTERIOR WALL FINISH AND SHALL BE INSTALLED TO PREVENT WATER FROM REENTERING THE EXTERIOR WALL ENVELOPE. APPROVED CORROSION -RESISTANT FLSHING SHALL BE INSTALLED AT ALL OF THE FOLLOWING LOCATIONS: 1. AT TOP OF ALL EXTERIOR WINDOW AND DOOR OPENINGS IN SUCH A MANNER AS TO BE LEAKPROOF, EXCEPT THAT SELF- FLASHING WINDOWS HAVING A CONTINUOUS LAP OF NOT LESS THAN 1-1/8" OVER THE SHEATHING MATERIAL AROUND THE PERIMETER OF THE OPENING, INCLUDING CORNERS, DO NOT REQUIRE ADDITIONAL FLASHING± JAMB FLASHING MAY ALSO BE OMITTED WHEN SPECIFICALLY APPROVED BY THE BUILDING OFFICIALS. 2. AT THE INTERSECTION OF CHIMNEYS OR OTHER MASONRY CONSTRUCTION WITH FRAME OR WALLS, WITH PROJECTING LIPS ON BOTH SIDES UNDER STUCCO COPINGS. 3. UNDER AND AT THE ENDS OF MASONRY, WOOD OR METAL COPINGS AND SILLS. 4. CONTINUOUSLY ABOVE ALL PROJECTING WOOD TRIM. 5. WHERE EXTERIOR PORCHES, DECKS OR STAIRS ATTACH TO A WALL OR FLOOR ASSEMBLY OF WOOD -FRAME CONSTRUCTION. 6. AT WALL AND ROOF INTERSECTIONS. -1. AT BUILT-IN GUTTERS. - ALL EXTERIOR DOORS, OTHER THAN FIRE -RATED DOORS, SHALL BE DESIGNED TO LIMIT AIR LEACKAGE AROUND THEIR PERIMETER WHEN IN A CLOSED POSITION. DOORS BETWEEN RESIDENCE AND GARAGE ARE NOT CONSIDERED FIRE -RATED AND MUST MEET THE ABOVE REQUIREMENT. ALL EXTERIOR WINDOWS SHALL BE DESIGNED TO AMIT INFILTRATION INTO OR FROM THE BUILDING ENVELOPE. - RECESSED LIGHTING FIXTURES: WHEN INSTALLED IN THE BUILDING ENVELOPE, RECESSED LIGHTING FIXTURES SHALL BE TYPE IC RATED AND CERTIFIED TO HAVE NO MORE THAN 2.0 CFM AIR MOVEMENT FROM THE CONDITIONED SPACE TO THE CEILING CAVITY. THE LIGHTING FIXTURE SHALL BE TESTED AT 15 PASCALS OR 1.5-1 L55/FT2 PRESSURE DIFFERENCE AND HAVE A LABEL ATTACHED, SNOWING COMPLIANCE WITH THIS TEST METHOD. RECESSED LIGHTING FIXTURES SHALL BE INSTALLED WITH A GASKET OR CAULK BETWEEN THE FIXTURE AND CEILING TO PREVENT AIR LEAKAGE. VAPOR 54RRIER5/ GROUND COVERS AN APPROVED VAPOR BARRIER SHALL BE PROPERLY INSTALLED IN ROOF DECKS, IN ENCLOSED RAFTER SPACES FROMED WHERE CEILINGS ARE APPLIED DIRECTLY TO THE UNDERSIDE OF ROOF RAFTERS, AND AT EXTERIOR WALLS, INSET STAPLED BATTS WITH A PERM RATING LESS THAN ONE MAY BE INSTALLED IF THE VAPOR BARRIER IS TO THE WARM SIDE, STAPLES ARE PLACED NOT MORE THAN a INCHES ON CENTER AND GAPS BETWEEN THE FACING AND THE FRAMING DO NOT EXCEED 1/16 INCH. A GROUND COVER OF 6 MIL (0.006")5LACK POLYETHYLENE OR EQUIVALENT, SHALL BE LAID OVER THE GROUND IN ALL CRAWL SPACES. THE GROUND COVER SHALL BE OVERLAPPED ONE FOOT AT EACH JOINT AND SHALL EXTEND TO THE FOUNDATION WALL. WINDOWS, DOORS, I-IV,4C, 4 ELECT. EQUIP. GLAZING MAXIMUM: ALL CLIMATE ZONES: GLAZING "U" VALUE: VERTICAL (MAX): .24 OVERHEAD (MAX): .50 DOOR "U" VALUE (MAX): .20 (DOORS W/ MORE THAN 50 CONSIDERED A WINDOW) HVAC PERFORMANCE: "MED" OR AFUE _ .36 RECESSED LIGHT FIXTURES: IC RATED DOORS, WINDOWS AND SKYLIGHTS GENERAL DOORS TO THE EXTERIOR, HAVE MAX. 3" STEP TO MIN. 36" DEEP LANDING. BEDROOM EMERGENCY EGRESS WINDOWS MINIMUM NET CLEAR OPENING OF 5.-1 SQ. FT. MIN. NET CLEAR OPEN ABLE WIDTH OF 20" AND MINIMUM NET CLEAR OPENING HEIGHT OF 24''MAXIMUM FINISHED SILL HEIGHT OF 44" ABOVE FLOOR. FACTORY BUILT WINDOWS TO BE CONSTRUCTED TO PERMIT MAXIMUM INFILTRATION OF 0.5 CFM PER LINEAL FOOT OF OPERABLE SASH PERIMETER AS TESTED BY ASTM STANDARDS. SITE BUILT AND MILL WORK SHOP BUILT WOODEN SASH ARE EXEMPT FROM INFILTRATION CRITERIA ABOVE, BUT MUST BE MADE TIGHTLY FITTING AND WEATHER STRIPPED OR CAULKED. SLIDING GLASS DOORS TO PERMIT MAXIMUM INFILTRATION OF 0.5 CFM INFILTRATION PER SQUTARE FOOT OF DOOR AREA. SAFETY GLAZING SHALL BE LOCATED WITHIN 1. INGRESS AND EGRESS DOORS 2. SLIDING GLASS DOORS, SWINGING GLASS DOORS 3. SHOWER AND BATHTUB ENCLOSURE'S 4.GLAZING W/ THE EXPOSED EDGE WITHIN A 24" ARC OF EITHER VERTICAL EDGE OF A DOOR IN THE CLOSED PORTIONS BOTTOM EDGE IS LESS THAN 60" ABOVE THE WALKING SURFACE GLAZING GREATER THAN 9 S.P. LESS THAN 13"A5OVE FINISHED FLOOR. Window sills: 612.2,24" minimum sill height exceptions allow for opening limiting device for 4" diameter sphere and window fall prevention device that complies with 612.3. STRUCTU AL NOTES ►A PERMANENT CERTIFICATE IS REQUIRED TO BE COMPLETED AND POSTED ON A WALL IN THE SPACE WHERE THE FURNACE IS LOCATED (OR OTHER APPROVED LOCATION) AND LIST THE FOLLOWING INFORMATION: R -VALUES, U -VALUES, RESULTS FROM DUCT SYSTEM AIR LEAKAGE TESTING, RESULTS FROM BUILDING ENVELOPE AIR LEAKAGE TESTING (BLOWER DOOR TEST), TYPES AND EFFICIENCIES OF HEATING, COOLING, AND SERVICE WATER HEATING EQUIPMENT. 8401.3. 0 -CORNERS OF STUD WALLS ARE REQUIRED TO BE FULLY INSULATED. 202, DEFINITION OF 'INTERMEDIATE FRAMED WALLS'. 0 -DUCTS ARE REQUIRED TO BE INSULATED TO A MINIMUM OF R-8. 8403.3.1. ►MECHANICAL SYSTEM PIPING IS REQUIRED TO BE INSULATED TO A MINIMUM OF R-6. 8403.4. ►HOT WATER PIPES ARE REQUIRED TO BE INSULATED TO A MINIMUM OF R-3. 8403.5.3 ►THE DWELLING IS REQUIRED TO BE TESTED AND VERIFIED AS HAVING AN AIR LEAKAGE RATE NOT EXCEEDING 5 AIR CHANGES PER HOUR (UNLESS A MORE STRINGENT REQUIREMENT IS MANDATED IN ORDER TO ACHIEVE THE ADDITIONAL REQUIRED CREDITS. 8402.4.1.2. ►MECHANICAL DUCTS ARE REQUIRED TO BE SEAL TESTED IN ACCORDANCE WITH 403.3.2_ TESTING TO COMPLY WITH WSU RS -33. fii'FE OF GONSTUGT ION UNPROTECTED WOOD FRAME v -B (EXAMPLES OF CONSTRUCTION ARE SINGLE FAMILY HOMES AND GARAGES. THEY OFTEN HAVE EXPOSED WOOD SO THERE IS NO FIRE RESISTANCE.) 5L�I❑D INC C❑A55IFICATICN R-3 I. ALL MATERIALS AND WORKMANSHIP SHALL CONFORM TO THE CONTRACT DRAWINGS. 2. DURING THE CONSTRUCTION PERIOD THE CONTRACTOR SHALL BE RESPONSIBLE FOR THE SAFETY OF THE BUILDING. 3. THE CONTACTOR SHALL BE SOLELY RESPONSIBLE FOR ALL CONSTRUCTION PROCEDURES INCLUDING LAGGING, SNORING AND PROTECTION OF ADJACENT PROPERTY, STRUCTUES, STREETS AND UTILITIES IN ACCORDANCE WITH ALL NATIONAL, STATE AND LOCAL SAFETY ORDINANCES. 4. THE CONTRACTOR SHALL BE RESPONSIBLE FOR COORDIANTING THE WORK OF ALL TRADES AND SHALL CHECK ALL DIMENSIONS. ALL DISCREPANCIES SHALL BE CALLED TO THE ATTENTION OF ENGINEER 5. ALL DETAILS DESIGNATED AS STANDARD OR TYPICAL SHALL OCCUR IN ADDITION TO ANY OTHER SPECIFIC DETAIL CALLED OUT 6. COORDIATE WITH MECHANICAL, PLUMBING, AND ELECTICAL REQUIREMENTS FOR SIZE AND LOCATION OF ALL OPENINGS REQUIRED FOR DUCTS, PIPES, AND PIPE SLEEVES, ELECTRICAL CONDUITS, AND OTHER ITEMS TO BE EMBEDDED IN CONCRETE OR OTHERWISE INCORPORATED IN STRUCTURAL WORK. -1. PROVIDE OPENINGS AND SUPPORTS, AS REQUIRED PER STANDARD DETAILS FOR HEATERS, MECHANICAL EQUIPMINT, VENTS, DUCTS, PIPING, ETC. ALL SUSPENDED MECHANICAL EQUIPMENT SHALL BE SWAY OR LATERALLY BRACED. N 70-3 M10 ADDRESS OR HOUSE NUMBER TO BE POSTED AND PLAINLY VISIBLE FROM THE STREET FRONTAGE. MIN. 4" HEIGHT, 1/2" STROKE WIDTH AND CONTRASTING BACKGROUND CIRC 313.1). PROPERTY ADDRESS SHALL BE POSTED PRIOR TO REQUESTING ANY INSPECTIONS CIRC 106.1.1 4 RESIDENTIAL GROUP R-3 OCCUPANCIES WHERE THE OCCUPANTS ARE PRIMARILY PERMANENT IN NATURE AND NOT CLASSIFIED AS GROUP R-1, R-2, R-4 OR I. BUILDINGS AND STRUCTURES OF AN ACCESSORY CHARACTER AND MISCELLANEOUS STRUCTURES NOT CLASSIFIED OCCUPANCY SHALL BE CONSTRUCTED, EQUIPPED AND MAINTAINED TO CONFORM TO THE REQUIREMENTS OF THIS CODE COMMENSURATE WITH THE FIRE AND LIFE HAZARD INCIDENTAL TO THEIR OCCUPANCY. Ncl) PRESCRIPTIVE COMPLIANCE IS BASED ON TABLE R402.1.1 WITH THE FOLLOWING MODIFICATIONS: VERTICAL FENESTRATION U = 0.24 (3a) GAS FURNACE: AIRQUEST VC 9-1 SERIES MODEL NO.: G3MAE0802120A EFFICIENCY: AFUE 31% (5a) ALL SHOWERHEAD AND KITCHEN SINK FAUCETS INSTALLED IN THE HOUSE SHALL BE RATED AT 111, GPM OR LESS. ALL OTHER LAVATORY FAUCETS SHALL BE RATED AT 1.0 GPM OR LESS. (5c) HOT WATER HEATER: RINNAI ULTRA SERIES TANKLESS WATER HEATER W/ EFFICIENCY RATING OF .3(o FfRESCfRIFTIVE ENEfRG""� COE)E Project Information Contact information This project will use the requirements of the Prescriptive Path below and incorporate the the minimum values listed. In addition, based on the size of the structure, the appropriate number of additional credits are checked as chosen by the permit applicant. Authorized Representative All Climate Zones o R -Value U -Factor Fenestration U -Factor n/a 0,30 Skylight U -Factor n/a 0.50 Glazed Fenestration SHG( ,e n/a n/a Ceilingk 49l 0.026 Wood Frame Wallg "'" 21 int 0.056 Mass Wall R -Value' 21/21 0.056 Floor 309 0.029 Below Grade Wall°" 10/15/21 int + TB 0.042 Slab R -Value & Depth 10, 2 ft n/a *Table R402.1.1 and Table R402.1.3 Footnotes included on Page 2. Date GLAZING "U" VALUE: VERTICAL (MAX): 0.24 WITH ENERGY CREDIT OPTION: Id Each dwelling unit in a residential building shall comply with sufficient options from Table R406.2 so as to achieve the following minimum number of credits: 1. Small Dwelling Unit: 1.5 credits ❑ Dwelling units less than 1500 square feet in conditioned floor area with less than 300 square feet of fenestration area. Additions to existing building that are greater than 500 square feet of heated floor area but less than 1500 square feet. E]2. Medium Dwelling Unit: 3.5 credits All dwelling units that are not included in #1 or #3. Exception: Dwelling units serving R-2 occupancies shall require 2.5 credits. ❑3. Large Dwelling Unit: 4.5 credits Dwelling units exceeding 5000 square feet of conditioned floor area. ❑4. Additions less than 500 square feet: .5 credits Table R406.2 Summary Option Description Credit(s) 1a Efficient Building Envelope 1a 0.5 ❑ lb Efficient Building Envelope lb 1.0 ❑ 1d Efficient Building Envelope 1d 0.5 0 0.5 r Leakage Control and Efficient Ventilation 2b 1.0 ❑ r I cnlennc (�nnfrnl onrl F:ffinicn+ \/cnfilmfinn ')n 1 'I F I F-1 3a JHigh Efficiency HVAC 3a 1.0 1.0 JuJ CIIIu:ICIIL VVQLCI fICQLIIIIY JU V.J U 6 lRenewable Electric Energy 0.5 *1200 kwh 0.0 Total Credits 3.50 *Please refer to Table R406.2 for complete option descriptions PLAN F EVIEW SCALE: NOT TO SCALE 0 U 0 0 W o ❑ 0.5 ❑ 1.5 U 5a Efficient Water Heating 5a 0.5 L7 5c Efficient Water Heating 5c 1.5 JuJ CIIIu:ICIIL VVQLCI fICQLIIIIY JU V.J U 6 lRenewable Electric Energy 0.5 *1200 kwh 0.0 Total Credits 3.50 *Please refer to Table R406.2 for complete option descriptions PLAN F EVIEW SCALE: NOT TO SCALE 0 U 0 0 W o U U O L7 m 2 c1 i O v Q C7 Q) LU Z 73 U1 W W co 1 I z O zLU 4 u1 Z Q LUA-) z00 m � m I�WZJ JJZOW r 0 Z?ooWQ 2 00 Qf, OQ Z� Z� pJN I� Uj W 2 WW�O U oZ �COc�W WI �� z o U O L7 m V c1 i O v C7 Q) LU Z 73 U1 W Q� 0 zz z zLU 4 u1 Z Q LUA-) z00 m � m „O 0 z V LU Z zz zLU z wz „O m> x Z LU as O Q U di N 0 O N Q N � W g= Project # : nooir&, 17170 Sheet Al TSF f CAL 1=L 00F� NOTE,5: 1. INSTALL SMOKE DETECTORS IN ALL SLEEPING ROOMS AND AT AREAS ADJACENT TO SLEEPING ROOMS, AND AT CEILING HEIGHT CHANGES GREATER THAN 24". SMOKE DETECTORS TO BE HARD -WIRED AND INTERCONNECTED, WITH BATTERY BACK-UP PER CODE. 2. INSTALL CARBON MONOXIDE SENSORS ADJACENT TO SLEEPING AREAS. 3. ALL INTERIOR WALLS TO BE 2x4 a 16" O.C. (U.N.O.) 4. ALL EXTERIOR WALLS TO BE 2x6 a 16" O.G. (U.N.O.) 5. MAIN FLOOR HEADERS PER STRUCTURAL a 8'-0" A.F.F.(U.N.O.) 6. WINDOW SIZES ARE NOMINAL ROUGH OPENING, WIDTH AND HEIGHT. 1. DOOR SIZES NOTED ARE SLABS NOT ROUGH OPENINGS 8. PROVIDE FIREBLOCKING AT ALL PLUMBING OPENINGS. 9. PROVIDE SOLID BLOCKING OVER SUPPORTS. 10 WHEN THERE IS USABLE SPACE BOTH ABOVE AND BELOW THE CONCEALED SPACE OF A FLOOR -CEILING ASSEMBLY, DRAFTSTOPS SHALL BE INSTALLED SO THAT THE AREA OF CONCEALED SPACE DOES NOT EXCEED 1000 SF. DRAFTSTOPPING SHALL DIVIDE THE CONCEALED SPACE INTO APPROXIMATELY EQUAL AREAS AND SHALL BE OF Y" GYP BOARD OR OTHER APPROVED MATERIALS INSTALLED PARALLEL TO THE FLOOR FRAMING MEMBERS PER CODE. 11. PROVIDE FIREBLOCKING TO CUT OFF ALL CONCEALED HORIZONTAL AND VERTICAL DRAFT OPENINGS AND TO FORM AN EFFECTIVE FIRE BARRIER BETWEEN STOIRES, AND BETWEEN A TOP STORY AND THE ROOF SPACE. FIREBLOGKING SHALL CONSIST OF NOT LESS THAN 2" NOMINAL LUMBER OR OTHER APPROVED MATERIAL. 12. ASPHALT -SATURATED FELT FREE FROM HOLES OR BREAKS, WEIGHING NOT LESS THAN 14 POUNDS PER 100 SQUARE FEET AND COMPLYING WITH ASTM D 226 OR OTHER APPROVED WEATHER RESISTANT MATERIAL SHALL BE APPLIED OVER SHEATHING OF ALL EXTERIOR WALLS. APPROVED ALTERNATIVE WEATHERPROOF MEMBRANES SHALL BE USED FOR OPEN JOINT RAIN SCREEN SIDING. WEATHER RESISTANT MATERIALS SHALL BE APPLIED HORIZONTALLY PERMANUFACTURERS RECOMMENDATIONS, WITH THE UPPER LAYER LAPPED OVER THE LOWER LAYER NOT LESS THAN 2 INCHES AND NOT LESS THAN 6 INCHES WHERE JOINTS OCCUR PER CODE. 13. APPROVED CORROSION -RESISTIVE FLASHING SHALL BE PROVIDED IN THE EXTERIOR WALL ENVELOPE IN SUCH A MANNER AS TO PREVENT ENTRY OF WATER INTO THE WALL CAVITY OR PENETRATION OF WATER TO THE BUILDINGS STRUCTURAL FRAMING COMPONENTS. THE FLASHING SHALL EXTEND TO THE SURFACE OF THE EXTERIOR WALL SURFACE AND SHALL BE INSTALLED TO PREVENT WATER FROM REENTERING THE EXTERIOR WALL ENVELOPE. FLASHING SHALL BE INSTALLED AT, BUT NOT LIMITED TO THE FOLLOWING LOCATIONS- -THE TOP OF ALL EXTERIOR WINDOW 8 DOOR OPENINGS -INTERSECTIONS OF FRAME WALLS AND MASONRY OR STUCCO -UNDER MASONRY, WOOD OR METAL COPINGS AND SILLS -CONTINUOUSLY ABOVE ALL PROJECTING WOOD TRIM -WHERE EXTERIOR PORCHES, DECKS OR STAIRS ATTACH TO A WALL -AT WALL AND ROOF OR SOFFIT INTERSECTIONS -AT BUILT-IN GUTTERS 14. EXTERIOR LOCATIONS FOR ENVIRONMENTAL AIR DUCT EXHAUST 8 INTAKE OPENINGS TO BE A MINIMUM OF 3'-0" FROM PROPERTY LINE 4 MINIMUM 3'-0" FROM BUILDING OPENINGS. EQUIP ALL DUCTS W/ BACK -DRAFT DAMPERS. 15. AIR EXHAUST 8 INTAKE OPENINGS THAT TERMINATE OUTDOORS SHALL BE PROTECTED W/ CORROSION RESISTANT SCREENS, LOUVERS, OR GRILLS W/ 1/4" MINIMUM 8 1/2" MAX OPENINGS IN ANY DIMENSION. OPENINGS SHALL BE PROTECTED AGAINST LOCAL WEATHER CONDITIONS PER IRC 8303.5, 16. DUCTS FOR KITCHEN RANGES SHALL BE OF METAL AND BE EQUIPPED W/ BACK -DRAFT DAMPERS PER CODE. 11. ALL INTERIOR FINISHES TO MEET MINIMUM FLAME SPREAD INDEX AND SMOKE DEVELOPMENT INDEX AS REQUIRED BY SECTION 8302.9.1 4 R302.9.2. 18. UNDER FLOOR CLEANOUT NOT MORE THAN 20' FROM ACCESS DOOR WITH AN UNOBSTRUCTED 30" WIDE X 18" HIGH PATH PATHWAY. CLEANOUTS ARE ACCESSIBLE. 12" CLEARANCE REQUIRED AT LINES LESS THAN OR EQUAL TO 2" 18" CLEARANCE AT LINES GREATER THAN 2". (UPC 101.9) 19. GLAZING IN ALL FIXED AND OPERABLE PANELS OF SWINGING, SLIFDING AND BIFOLD DOORS SHALL BE CONSIDERED A HAZARDOUS LOCATION, 8308.4.1. SAFETY GLAZING. GAFRAGE NOTES" 1. GARAGES SHALL BE SEPARATED FROM THE RESIDENCE AND ITS ATTIC AREA BY NOT LESS THAN 5/8" TYPE X GWB APPLIED TO THE GARAGE SIDE. WHERE THE SEPARATION IS A FLOOR -CEILING ASSEMBLY, THE STRUCTURE SUPPORTING THE SEPARATION SHALL ALSO BE PROTECTED BY NOT LESS THAN %" TYPE X GYPSUM BOARD OR EQUIVALENT. 2. OPENINGS BETWEEN THE GARAGE AND RESIDENCE SHALL BE EQUIPPED WITH SOLID WOOD DOORS NOT LESS THAN 1 3/8" IN THICKNESS, SOLID OR HONEYCOMB CORE STEEL DOORS NOT LESS THAN 1 3/8" THICK, OR 20 -MINUTE FIRE -RATED DOORS. 3, DUCTS IN THE GARAGE AND DUCTS PENETRATING THE WALLS OR CEILINGS SEPARATING THE DWELLING FROM THE GARAGE SHALL BE CONSTRUCTED OF A MINIMUM NO. 26 GAGE SHEET STEEL OR OTHER APPROVED MATERIALS AND SHALL HAVE NO OPENINGS INTO THE GARAGE. IRC 8309.1.1 4. IN SIESMIC ZONES 3 8 4, WATER HEATERS SHALL BE ANCHORED TO RESIST NORZ. DISPLACEMENT DUE TO EARTHQUAKE MOTION. STRAPPING SHALL BE s POINTS WITHIN THE UPPER ONE THIRD AND LOWER ONE THIRD PER UPC SEC. 510.5 5, PROVIDE OUTDOOR COMBUSTION AIR FOR WATER HEATER 6. GARAGE FLOOR SURFACES SHALL BE OF APPROVED NONCOMBUSTIBLE MATERIAL AND THE AREA USED FOR THE PARKING OF AUTOMOBILES OR OTHER VEHICLES SHALL BE SLOPED TO FACILITATE THE MOVEMENT OF LIQUIDS TO A DRAIN OR TOWARD THE MAIN VEHICLE ENTRY DOORWAY. NOTE: EACH DOOR TO BE UNDERCUT A MINIMUM OF 1/2 -INCH TO ASSURE FREE FLOW OF FRESH AIR THROUGHOUT HABITABLE ROOMS ,5t"-10< D T CT0FR5 A SMOKE DETECTOR SHALL BE INSTALLED IN EACH HABITABLE ROOM. A SMOKE DETECTOR SHALL BE CENTRALLY LOCATED ON EACH FLOOR. AN ADDITIONAL SMOKE DETECTOR SHALL BE INSTALLED IN EACH LOCATION WHERE THERE IS A CEILING HEIGHT CHANGE GREATER THAN 24", SMOKE DETECTORS TO BE 110\/ HARDWIRED, INTERCONNECTED, WITH BATTERY BACKUP PER IRC 8313 C;A 50 t­IONOX f D ALA �l PER IRC 8315.1 AND WAG 51-50-0901 FOR NEW CONSTRUCTION, AN APPROVED CARBON MONOXIDE ALARM SHALL BE INSTALLED OUTSIDE OF EACH SEPARATE SLEEPING AREA IN THE IMMEDIATE VICINITY OF THE BEDROOM IN DWELLING UNITS WITHIN WHICH FUEL -FIRED APPLIANCES ARE INSTALLED AND IN DWELLING UNITS THAT HAVE ATTACHED GARAGES. SINGLE STATION CARBON MONOXIDE ALARMS SHALL BE LISTED AS COMPLYING WITH UL 2034 AND SHALL BE INSTALLED IN ACCORDANCE WITH THIS GODS AND THE MANUFACTURER'S INSTALLATION INSTRUCTIONS. 1 3 10 A ,46 52'-0" 1'-0" 2'-10" 10'-0" 2'-6" 1'-8" S'-10" 5'- " 5'-0" 2'-0" 2'-0" S'-6" IlV 1'-0" CANT LEVER FIREPLACE EXHAUST CANT L VER TO EXTERIOR - 8060 SLDR - 8060 eLDR L INE OF FLOOR ABOVE - �„ UILT- INS 2 WALL PER STR T RAL 4Lu = I iENGINEERING S -SNE 4" OHC. } I 2 6i 10 -0 CLG. O A6 A6 �p + 10'-0" CLG. I STALL ZERO -CLE NCE CO D OUTDOOR LIVING . (q . ; 12'- " X 11'-0" .. q 1 HR. RATED 11.1 p rD f I �l I I �� �'� I I DIRECT VENT 3 -WA lfJ OD - 1'-S" X 16'-6"+ ul �. fY } 0 Wil BURNING FIRE PLA( PER "'�`� � � N N 14'-10"XII'-4'+ 00, MANUF. SPECS. ON 6 AISED PEDESTAL -4 � O I N. OF BEAM ABV. O 3'-S" 5'-O' 4 -14 {1_4" g _ z �t } 302.1 UNDER-STAI OTECTION. LOSED 00 CCESSIBLE SPA( ER STAIR ALL 2 5 PIC. C AVE WALLS, UNDE -� AIR SURFACE AND ANY Q SOFFITS PROTECTE (p$ THE ENCL S D SIDE IIDv PREP. WITH 1/2 INCH GYPSU OARD. I S.D. 2 6 ISLAND ql FJ e.M. `Q i fk � PROVIDE MIN. 1 � BATH. 3 _ ' d 18" X 24' CRAWL �I -SPACE ACCESS Al N SAFETY GLASS 0 _ L'L _ __NAULATE AND LN. OF FLR. ,d,BV.- - - �4 WEATHER STRIP o "x6 I I q u1 �'-�" 2'-�" 4'-10" 0 0 OPEN TOA V. `" R. & S. OW - W.G. a p/\ s (k m ENTRY FOY R o = o q 28PKT. DR. 2> : WA L 1 24 8'-0" X �'-0" -Ir r, Uwe 6l Z - R. 6 S. wo �I +10'-0" CLG. -Kv 5 qII tlJ OSD ------ Li i /�II II `I � � o - ---- � � cv � LQI� �`' = m fi 1 �l 2 6 / �dt P NTRY (L -' // e em 14 -10 X 12'-6"+REFER m s s \4 PROVIDE �IRE-SEPA ONE RA-Ti6N-FOR - ® - - I � -� SAFETY GL SS LIVING AREAS Is 0 2 PIG. S. -' FIRE BLOCKING SHALL BE ADJACENT e ABOVE cfJ ' - r✓, ..PIC'. A - MUD RM. 12 I� PROVIDED IN FULL -HEIGHT .� - n - ' • ' WACLv�. i=OR-ASD?T1�NA-L MIN. R-21 INSUL., _ - 4' G NC. FIREBLOCKING DETAILS SEE TYPICAL p Z ENTR PORGY .. NOTES ON SHEET -A6. 8 - _ _ -� - :. � 1. 8. 8' 0° m LAND mid IG :..:'. 4" DIA. STEEL .. • �.•:..� :. •; 2 s I ..10'-0" BOLLARD --- --- 12'-0" X 11'-4"+ .r�!BEB 2� 1- A 4+ ROUGH -SAWN 4 EXPOSED 4 _�" SEE EL ATIO - - - T - -- DECORATIVE BEAMS O 18 H PLATFORM... - 4 U �Lu 0 W/ (2) LAYERS : :. ... e ....:..:...:. L... ; Z u11U : 3/4" PLYWOOD _ :.N . qIFT U L ::: I RO CsH-SA .:I:P :S` ..,i EGRESS � Lu u q m � 1�i PER, STRUCT R 8060 SLDR. J �Q Z q 13/0" SOLID CORE ENGINEERING S SHEET �L u1 m U WOOD OR 20 MIN. - Z } SE ON BAS W APPE Z 4 0 O U FIRE RATED MTL W/ TONE VENEE _ - 4 ui DR. W/ SELF CLOSER .....:. ......" . ;.. :..: ... .. 1 ' :.... �; (Y Luu !u Z �7 u1 : 7 ::. ; • ' .. :LN. OF ROOF BV. TO DRAIN :.. �t U q (Y !� TOWARD O.H.DR.; .. I'•:::...` :..:. 1 } .. . . N d) L1 111 q m- O LL RD O L I 4 CONC.. I q ... .. .. .. • 113'-0"X 23.-6 ..... :. . GLAZING IN ALL FIXE AND PERA E NOTE: q ' " PANEL OF S INGING, SLIDINGAND GARAGE/DWELLING SEPER TION 51FOLE DOORS SHALLBEC NSIDE ED : I ON THE GARAGE SIDE OF WALLS :. A HAZ RDO LOGA ION, R300.4.1. 1 •.. O AND CEILING WITH MIN. 1/2" WB W. SAFETY GLA ING. AND 5/8 TYPE X GWB AT Z . CEILING WITH HABITABLE R OM :. `•. :: t .,' ::.: :.. I ABOVE (TABLE R302.6). J SLOPE TO DRAIN , T WARD O.H. DR. _ LINE OF FL OR AB VE L I HTWE IGHT STONE VENEER, TYP. 3 Al I I I I I 10'-O" 10'-0" 6 '-�" 4'-9" 2'-4" 2'-6" 2'-102° _54 _54 20'-0" 111-411 _81 12'-112lo I" I I I I I I I 52 -0" I I I I I I I I I NOTE: REFER TO STRUCTURAL SHEETS FOR SHEAR WALL SCHEDULE AND ENGINEERING PLAN WHICH CONTAIN REFERENCES AND/OR INSTRUCTIONS PERTAINING TO EACH SHEAR WALL INDICATED IN THIS PLAN MAIN FLOOR PLAN SCALE: 1/4" = 1'-0" WRAP-AROUND POST 8 A T_ B LIGHTWEIGHT STONE VENEER, TYP_ (1) T CON( T DRIVEWAY V RE EDR E PER SITE PLAN i NOTE: CONTRACTOR TO VERIFY ALL DIMENSIONS AND CONDITIONS OF PROJECT AND REPORT ANY OMISSIONS / DISCREPANCIES TO DESIGNER PRIOR TO COMMENCING WORK. DESIGNER SHALL NOT BE RESPONSIBLE FOR DISCREPANT CONDITIONS RESULTING FROM UNAUTHORIZED WORK PERFORMED BY THE CONTRACTOR. A,45UMMA'T' MAIN FLOOR: 1,345 sf. UPPER FLOOR: 1,188 sf. TOTAL: GARAGE: ENTRY PORCH: COV'D PATIO (REAR): 3,133 sf. 428 sf. (01 sf. 131 sf. W o U o0 S 2 m lY O Q) Lu O Z z rn L7 Q) �I�pO �W1'oo� to z QU zz �J OQ Q Iii I�WZJ r Z� JJZOW C() LUz L e Z WW�p IL � o o0 S L7 m lY Q) Lu O Z z rn L7 Q) to z QU zz �J OQ Q Iii wa) Z� 'nLu C() LUz e Z WW�p O "z L m> d) Z� LU F o a a r D 4 U N N L6 w N 1u WILn� IL � o o0 S L7 m lY Q) Lu O Z z rn L7 Q) to z W zz z- u.i Q Iii wa) Q 'nLu C() LUz e z lY Lu (X w to z zz 'nLu LUz Z O "z m> d) Z� LU F o a a r D 4 U N N L6 w N 1u c�A t- _q _q N ■ Project # _ = 17170 Sheet A2 TSF f CAL FLCCfR NOTE 5: 1. INSTALL SMOKE DETECTORS IN ALL SLEEPING ROOMS AND AT AREAS ADJACENT TO SLEEPING; ROOMS, AND AT CEILING HEIGHT CHANGES GREATER THAN 24". SMOKE DETECTORS TO BE HARD -WIRED AND INTERCONNECTED, WITH BATTERY BACK-UP PER CODE. 2. INSTALL CARBON MONOXIDE SENSORS ADJACENT TO SLEEPING AREAS. 3. ALL INTERIOR WALLS TO BE 2x4 a 16" O.G. (U.N.O.) 4. ALL EXTERIOR WALLS TO BE 2x6 Q 16" O.C. (U.N.O.) 5. UPPER FLOOR HEADERS PER STRUCTURAL e 6-0" A.F.F. (U.N.O.) 6. WINDOW SIZES ARE NOMINAL ROUGH OPENING, WIDTH AND HEIGHT. I. DOOR SIZES NOTED ARE SLABS NOT ROUGH OPENINGS 8, PROVIDE FIREBLOCKING AT ALL PLUMBING OPENINGS. 9. PROVIDE SOLID BLOCKING OVER SUPPORTS. 10 WHEN THERE IS USABLE SPACE BOTH ABOVE AND BELOW THE CONGEALED SPACE OF A FLOOR -CEILING ASSEMBLY, DRAFTSTOPS SHALL BE INSTALLED SO THAT THE AREA OF CONCEALED SPACE DOES NOT EXCEED 1000 SF. DRAFTSTOPPING SHALL DIVIDE THE CONCEALED SPACE INTO APPROXIMATELY EQUAL AREAS AND SHALL BE OF Y" GYP BOARD OR OTHER APPROVED MATERIALS INSTALLED PARALLEL TO THE FLOOR FRAMING MEMBERS PER CODE. 11. PROVIDE FIREBLOCKING TO CUT OFF ALL CONCEALED HORIZONTAL AND VERTICAL DRAFT OPENINGS AND TO FORM AN EFFECTIVE FIRE BARRIER BETWEEN STOIRES, AND BETWEEN A TOP STORY AND THE ROOF SPACE. FIREBLOCKING SHALL CONSIST OF NOT LESS THAN 2" NOMINAL LUMBER OR OTHER APPROVED MATERIAL. 12. ASPHALT -SATURATED FELT FREE FROM HOLES OR BREAKS, WEIGHING NOT LESS THAN 14 POUNDS PER 100 SQUARE FEET AND COMPLYING WITH ASTM D 226 OR OTHER APPROVED WEATHER RESISTANT MATERIAL SHALL BE APPLIED OVER SHEATHING OF ALL EXTERIOR WALLS. APPROVED ALTERNATIVE WEATHERPROOF MEMBRANES SHALL BE USED FOR OPEN JOINT RAIN SCREEN SIDING. WEATHER RESISTANT MATERIALS SHALL BE APPLIED HORIZONTALLY PERMANUFACTURERS RECOMMENDATIONS, WITH THE UPPER LAYER LAPPED OVER THE LOWER LAYER NOT LESS THAN 2 INCHES AND NOT LESS THAN 6 INCHES WHERE JOINTS OCCUR PER CODE. 13. APPROVED CORROSION -RESISTIVE FLASHING SHALL BE PROVIDED IN THE EXTERIOR WALL ENVELOPE IN SUCH A MANNER AS TO PREVENT ENTRY OF WATER INTO THE WALL CAVITY OR PENETRATION OF WATER TO THE BUILDINGS STRUCTURAL FRAMING COMPONENTS. THE FLASHING SHALL EXTEND TO THE SURFACE OF THE EXTERIOR WALL SURFACE AND SHALL BE INSTALLED TO PREVENT WATER FROM REENTERING THE EXTERIOR WALL ENVELOPE. FLASHING SHALL BE INSTALLED AT, BUT NOT LIMITED TO THE FOLLOWING LOCATIONS: -THE TOP OF ALL EXTERIOR WINDOW 8 DOOR OPENINGS -INTERSECTIONS OF FRAME WALLS AND MASONRY OR STUCCO -UNDER MASONRY, WOOD OR METAL COPINGS AND SILLS -CONTINUOUSLY ABOVE ALL PROJECTING WOOD TRIM -WHERE EXTERIOR PORCHES, DECKS OR STAIRS ATTACH TO A WALL -AT WALL AND ROOF OR SOFFIT INTERSECTIONS -AT BUILT-IN GUTTERS 14. EXTERIOR LOCATIONS FOR ENVIRONMENTAL AIR DUCT EXHAUST 8 INTAKE OPENINGS TO BE A MINIMUM OF 3'-0" FROM PROPERTY LINE 4 MINIMUM 3'-0" FROM BUILDING OPENINGS. EQUIP ALL DUCTS W/ BACK -DRAFT DAMPERS. 15. AIR EXHAUST 8 INTAKE OPENINGS THAT TERMINATE OUTDOORS SHALL BE PROTECTED W/ CORROSION RESISTANT SCREENS, LOUVERS, OR GRILLS W/ 1/4" MINIMUM 8 1/2" MAX OPENINGS IN ANY DIMENSION. OPENINGS SHALL BE PROTECTED AGAINST LOCAL WEATHER CONDITIONS PER IRC 8303.5. 16, DUCTS FOR KITCHEN RANGES SHALL BE OF METAL AND BE EQUIPPED W/ BACK -DRAFT DAMPERS PER CODE. 1-1. ALL INTERIOR FINISHES TO MEET MINIMUM FLAME SPREAD INDEX AND SMOKE DEVELOPMENT INDEX AS REQUIRED BY SECTION 8302.9.1 8 R302.9.2. 18. UNDER FLOOR CLEANOUT NOT MORE THAN 20' FROM ACCESS DOOR WITH AN UNOBSTRUCTED 30" WIDE X 18" HIGH PATH PATHWAY, CLEANOUTS ARE ACCESSIBLE. 12" CLEARANCE REQUIRED AT LINES LESS THAN OR EQUAL TO 2", 18" CLEARANCE AT LINES GREATER THAN 2". (UPC -10-1.9) 19. GLAZING IN ALL FIXED AND OPERABLE PANELS OF SWINGING, SLIFDING AND BIFOLD DOORS SHALL BE CONSIDERED A HAZARDOUS LOCATION, R308.4.1. SAFETY GLAZING. A FRA GT E N C T E 5: 1. GARAGES SHALL BE SEPARATED FROM THE RESIDENCE AND ITS ATTIC AREA BY NOT LESS THAN 5/8" TYPE X GWB APPLIED TO THE GARAGE SIDE. WHERE THE SEPARATION IS A FLOOR -CEILING ASSEMBLY, THE STRUCTURE SUPPORTING THE SEPARATION SHALL ALSO BE PROTECTED BY NOT LESS THAN %" TYPE X GYPSUM BOARD OR EQUIVALENT. 2. OPENINGS BETWEEN THE GARAGE AND RESIDENCE SHALL BE EQUIPPED WITH SOLID WOOD DOORS NOT LESS THAN 1 3/8" IN THICKNESS, SOLID OR HONEYCOMB CORE STEEL DOORS NOT LESS THAN 1 3/8" THICK, OR 20 -MINUTE FIRE -RATED DOORS. 3. DUCTS IN THE GARAGE AND DUCTS PENETRATING THE WALLS OR CEILINGS SEPARATING THE DWELLING FROM THE GARAGE SHALL BE CONSTRUCTED OF A MINIMUM NO. 26 GAGE SHEET STEEL OR OTHER APPROVED MATERIALS AND SHALL HAVE NO OPENINGS INTO THE GARAGE. IRC 8309.1.1 4. IN SIESMIC ZONES 3 8 4, WATER HEATERS SHALL BE ANCHORED TO RESIST HORZ. DISPLACEMENT DUE TO EARTHQUAKE MOTION. STRAPPING SHALL BE a POINTS WITHIN THE UPPER ONE THIRD AND LOWER ONE THIRD PER UPC SEC. 510.5 5. PROVIDE OUTDOOR COMBUSTION AIR FOR WATER HEATER 6. GARAGE FLOOR SURFACES SHALL BE OF APPROVED NONCOMBUSTIBLE MATERIAL AND THE AREA USED FOR THE PARKING OF AUTOMOBILES OR OTHER VEHICLES SHALL BE SLOPED TO FACILITATE THE MOVEMENT OF LIQUIDS TO A DRAIN OR TOWARD THE MAIN VEHICLE ENTRY DOORWAY. NOTE: EACH DOOR TO BE UNDERCUT A MINIMUM OF 1/2 -INCH TO ASSURE FREE FLOW OF FRESH AIR THROUGHOUT HABITABLE ROOMS A SMOKE DETECTOR SHALL BE INSTALLED IN EACH HABITABLE ROOM. A SMOKE DETECTOR SHALL BE CENTRALLY LOCATED ON EACH FLOOR. AN ADDITIONAL SMOKE DETECTOR SHALL BE INSTALLED IN EACH LOCATION WHERE THERE IS A CEILING HEIGHT CHANGE GREATER THAN 24". SMOKE DETECTORS TO BE 110v HARDWIRED, INTERCONNECTED, WITH BATTERY BACKUP PER IRC 8313 CAF 5C 1 1"',*IONOXIDE AL AFRI PER IRC R315.1 AND WAC 51-50-0901 FOR NEW CONSTRUCTION, AN APPROVED CARBON MONOXIDE ALARM SHALL BE INSTALLED OUTSIDE OF EACH SEPARATE SLEEPING AREA IN THE IMMEDIATE VICINITY OF THE BEDROOM IN DWELLING UNITS WITHIN WHICH FUEL -FIRED APPLIANCES ARE INSTALLED AND IN DWELLING UNITS THAT HAVE ATTACHED GARAGES. SINGLE STATION CARBON MONOXIDE ALARMS SHALL BE LISTED AS COMPLYING WITH UL 2034 AND SHALL BE INSTALLED IN ACCORDANCE WITH THIS CODE AND THE MANUFACTURER'S INSTALLATION INSTRUCTIONS. no I NOTE: REFER TO STRUCTURAL SHEETS FOR SHEAR WALL SCHEDULE AND ENGINEERING PLAN WHICH CONTAIN REFERENCES AND/OR INSTRUCTIONS PERTAINING TO EACH SHEAR WALL INDICATED IN THIS PLAN 1 .4ro A A6 52'-m" 2'-1011 101-011 1 2'-4" 5._ 5 _0 5._2.. 51-011 0-011 I I I I I 806° SLDR 8060 LDR 305 CASE ACRES 60 60 SLDR 00 �j 32 "x60" 2t TUB/SHOWER + 9'-0" CLC. 0 -A @ - + 9 7 '-0" CLC. U- fQ LAUNDRY _� E3 D . 3 OO �I SII r 10'-10" X 12'-4"+ N 10'_6"X 14'_4" V u- WHOLE HOUSE FAN A LL U- W/ AUTO TIMER 8 21 GUARD RAILS MUST BE O O MANUAL OVERRIDE ABLE TO WITHSTAND A -- CONCENTRATED LOAD OF U U 200 Ibs. AP LIED AT ANY Ov p- + 9'-0" GLC. POINT ALONG THE RAIL IN BATH 2 9 } ANY DIRECTIPN. PER Q0 � S T . S T 0110\/ - TABLE R301.5 14'-8" X 16'-O"+ 2S L IICy o s .9 I � HALL c,l O �.: ✓. _ R.4S. iv -1011 12'-S" �.M. 5'-6" �t 30 GUARDRAIL a + 3 H. A.F.F. � R. � S. - miv I v Oil 1U D 1 q Z MSTR. BATH 2 ro A� ® =iv OPEN O - p cn U ? 4 a ® cv FOYER �tu �� 4 z C170 r BELOW o % o tu r loll 1& 0 FIRE BLOCKING SHALL BE �4'-�0" 4'-2" _� N PROVIDED IN FULL -HEIGHT 6 4 ivO WALLS. FOR ADDITIONAL -ERF-51OCKINCz DETAILS SEE 0d - - cfJ Q 13 O 503x' P G. NOTES ON SHEET-A(o. � 12 X0p )~ tt �G IG T + 9'-0" CLG. LL 4 2 4 _ 2'-10° 9' � N CAM 12'-O"X W.LC. - SEE ELEVATION [ ev PROVIDE MIN. 22"x30" -� LINE OF ROOF 511LOW (Li AT IC ACCESS INSULATE \ `4 8 WEATHER STRIPIL- - - sRESS R. S. 8060 SLDR. I lov N I 0 S.D. I � I I I I 4" GONG. Q Lu 0 �n }0 19'-0" X 14'-0"+ LU J Q �� GUARD RAILS MUST BE ABLE TO z 0 co � WITHSTAND A CONCENTRATE LOAD k 09 OF 200 Ibs. APPLIED AT AN POINT ALONG THE RAIL IN ANY DIRECTION. 4 PER TABLE 8301.5 I I I I I I I I I 8060 SLDR. I -CANTILEVER I I I I I I I I I I I 4'-9" 3'-10" 3'_1011 4 5'- 101-011 5'-011 11' 13'-011 UPPER FLOOR PLAN SCALE: 1/4" = 1'-0" NOTE: CONTRACTOR TO VERIFY ALL DIMENSIONS AND CONDITIONS OF PROJECT AND REPORT ANY OMISSIONS / DISCREPANCIES TO DESIGNER PRIOR TO COMMENCING WORK. DESIGNER SHALL NOT BE RESPONSIBLE FOR DISCREPANT CONDITIONS RESULTING FROM UNAUTHORIZED WORK PERFORMED BY THE CONTRACTOR. AA 5UAr MAIN FLOOR: 1,345 sf. UPPER FLOOR: 1,788 sf_ TOTAL - G, 4 f; R, 4 G E: OTAL:GARAGE: ENTRY PORCH: COV'D PATIO (REAR): 3,133 s f. 428 sf_ 61 Sr. 13-1 6F. W 0 U U 'n o V' m 2 ca Lu O� Q L z �► L7 Q) Luz N 0� W # 3 QU �I�pO z- �J %nw < ui Z Z� u� z� Z �� I I ZWZ� ��ZOW r 0 N L � J TZ L z 0 U m 'n o V' m ca Lu O� Z z �► L7 Q) Luz N 0� W # 3 QU OQ z- �J %nw < ui Z Z� u� z� Z �� N L 0 N m> L WL 0X U� �2 � 0 D N Q N z 0 U 'n o V' m ca Lu O� Z z �► L7 Q) Luz N 0� W # 3 Q z- %nw < ui Z Q u� z� Z „O 0 N z Lu �L" Luz zz %nw Wz Z „O z m> 0X � 0 D N Q N N lu N Project # : 17170 Sheet /k3 MAX. ROOF HEIGHT 6 282.3' MAX. ROOF HEIGHT 6 282.3' TOP OF RIDGE TOP OF ROOF 0 COMP. SHINGLES, TYP. 12 12 COMP. SHINGLES TYP. =ir 4� �4 �4 N MAX. WALL PLATE 6 2-l6.3' 4J? q..1Z 41Z MAX. WALL PLATE a 2-i6.3' -PL. BONUS RM.- PL I PL. UPPER FLOOR PL. UPPER FLOOR CONT. METAL GUTTER ON 5/4X8 FASCIA BOARD TYP. HARDIE PANEL SIDING, TYP. CEDAR SIDING, TYP. OR HARDIE LAP SIDING UPPER FLOOR �t SOFFIT, VENT 8 INSULATE CANT'L W/ R-30 INSUL. HARDIE PANEL SIDING, TYP. APPROX. HEIGHT OF STONE VENEER 3 LIGHTWEIGHT STONE VENEER, TYPICAL MAIN FLOOR a 254.1' 254.0' GAR. SLAB a 253.2' FINISH GRADE GRADE PLANE 6 252.3' GRADE PLANE 252.3' 252.0' 1 2 A6 A6 250.0' 1 HR. RATED MAX. ROOF HEIGHT 6 2023' TOP OF RIDGE OF INT. LAND �1 11 .......... ON Qu �: i��� - ■Illl�a mom FRONT ELEVATION SCALE: 1/4" = 1'-0" UPPER FLOOR PL_ a MAIN FLOOR r = L IGHTWE IGHT STONE 3 VENEER, TYPICAL A� - 256,01 MAIN FLOOR MAIN FLR. a 254.-l' 254.0' FINISH GRADE SLAB s 253.2' rtONCREfi� ENTRY 252.0' PORCH AVERAGE GRADE 250.0' 12 12 �4 COMP. SHINGLES, TYP. 4� MAX. WALL PLATE Q 2-16.3' 4:12 ELEVATION NOT 5: 1. VERIFY SHEAR WALL NAILING e 1HOLDOWNB PER PLAN PRIOR TO INSTALLING SIDING. CONT. METAL GUTTER ON 5/4X8 FASCIA 2. MASONRY 4 WOOD FRAME CHIMNEYS ARE TO 5E BOARD TYP. CONSTRUCTED PER I.R.G. CHAPTER 10 3. CAULK ALL EXTERIOR JOINTS 8 PENETRATIONS. 4. PROVIDE APPROVED CORROSION RESISTANT FLASHING HARDIE LAP SIDING, -` AT EXTERIOR WALL ENVELOPE PER I.R.G. R-103.4 TYPICAL 5. PROVIDE FLASHING AT ROOF PENETRATIONS PER 1. C. 8903.2 8 8903.2.1 6• PROVIDE WEATHER STRIPPING AT ALL EXTERIOR 4 GARAGE -INTERIOR DOORS. NEW WINDOWS AND DOORS TO 5E MAX. U -VALUE OF 0.24. �• PROVIDE CONTINUOUS GUTTERS 4 DOWNSPOUTS e ALL EAVES, TYP. LIE 8, ADDRESS OR HOUSE NUMBER TO BE POSTED AND PLAINLY SOFFIT, VENT 4 VISIBLE FROM THE STREET FRONTAGE. MIN. 4" HEIGHT, 1/2" STROKE INSULATE CANT'L WIDTH AND CONTRASTING BACKGROUND, W/ R-30 INSUL. a PROVIDE STAIRWAY ILLUMINATION PER I.R.C. 83031 6 303.8 10, SEE SHEET Al FOR ADDITIONAL NOTES. 11, PROVIDE SURFACE DRAINAGE 6" : 10' MIN. AWAY FROM HOUSE FOOTPRINT IRC 8401.3 HARDIE PANEL SIDING, TYP. 256.0' MAIN FLOOR 6 254.7' �bT1GTE�Afir�S. 2 54.0' GAR. SLAB 9 253.2' GRADE PLANE a 252.3' 252.0' SOFFIT, VENT 8 INSULATE CANT'L W/ R-30 INSUL. NOTE: CONTRACTOR TO VERIFY ALL DIMENSIONS AND CONDITIONS OF PROJECT AND REPORT ANY OMISSIONS / DISCREPANCIES TO DESIGNER PRIOR TO COMMENCING WORK. DESIGNER SHALL NOT BE RESPONSIBLE FOR DISCREPANT CONDITIONS RESULTING FROM UNAUTHORIZED WORK PERFORMED 5Y THE CONTRACTOR. FREAf SCALE: 1/4" = 1'-0" VATION 1� 0 MAX. ROOF HEIGHT a 282.3' TOP OF RI COMP. SHINGLES TYP_ PL. 'a UPPER FLOOR 6" CORNER TRIM, TYPICAL HARDIE LAP SIDING, 6' TYPICAL UPPER FLOOR PL. @ MAIN FLOOR HARDIE PANEL, TYPICAL 256.0' MAIN FLOOR MAIN FLR. 6 254.-l' 254.0' FINISH GRADE SLAB a 253.2' 252.0' AVERAGE GRADE 252.3' 250.0' W o U U `n o s Z (P O 0 V Q) N WJW 0� W I Q x � Z �5tu 'cu s d ui tuz Q L"Ln I�WZJ JJZOW r O "z o ?�W a 0J��� 0 N Q L 0 a ^L LL IL E z o U 0 `n o s L7 (P O 0 V Q) N 0� W Q� Q x � Z �5tu 'cu s d ui tuz Q L"Ln m -� O "z 0 N z �z Z z �5tu tuz O "z > N x Lu F a a � Q U L =3 Lii � 0 � �C" LuN N p= Project # : 17170 Sheet A4 MAX. ROOF HEIGHT a 282.3' TOP OF RIDGE MAX. WALL PLATE 2-l6.3' -� -PL. BONUS RM. BUMP -OUT PL. UPPER FLOOR CEDAR SIDING, TYP. OR HARDIE LAP SIDING 6" CORNER TRIM, TYP. GUARD RAILS MUST BE ABLE TO WITHSTAND A CONCENTRATED LOAD OF 200 lbs. APPLIED AT ANY POINT ALONG THE RAIL IN ANY DIRECTION. PER TABLE 8301.5 UPPER FLOOR PL. a MAIN FLOOR SOFFIT, VENT 8 INSULATE CANT'L W/ R-30 INSUL. HARDIE PANEL - SIDING, TYP. 12 / 12 4:12 4 4:12 L IGHTWE IGHt STONE _ - S. S.G. VENEER, TYPICAL 3 - 12 ,-,�4 COMP. SHINGLES TYP. =ir PL. a UPPER FLOOR CONT. METAL GUTTER ON 5/4X8 FASCIA BOARD TYP. 6" CORNER TRIM, TYPICAL HARDIE LAP SIDING, TYPICAL UPPER FLOOR ------------------- PL. a MAIN FLOOR SOFFIT, VENT 8 INSULATE CANT'L W/ R-30 INSUL. HARDIE PANEL, TYPICAL RAP -AROUND POST =iN MAX. ROOF HEIGHT a 282.3' TOP OF RIDGE MAX. WALL PLATE 2_16.3' w 256.0' 256 .0' MAIN FLOOR a 254.x' MAIN FLOOR .� �.� _ R254.0' GAR. SLAB a 253.2' FINISH GRADE - - «> GRADE PLANE a 252.3' = CONCRETE DRIVEWAY 252.0' GLAZING IN ALL FIXED AND OPERABLE PANELS OF SWINGING, SLIDING AND BIFOLD DOORS SHALL BE CONSIDERED A HAZARDOUS LOCATION, 8308.4.1. SAFETY GLAZING. MAX. ROOF HEIGHT a 2023' TOP OF RIDGE ELEVATION NOTES= 1, VERIFY SHEAR WALL NAILING 4 HOLDOWNS PER PLAN PRIOR TO INSTALLING SIDING. 2. MASONRY 8 WOOD FRAME CHIMNEYS ARE t0 BE CONSTRUCTED PER I.R.C. CHAPTER 10 3. CAULK ALL EXTERIOR JOINTS 4 PENETRATIONS. 4. PROVIDE APPROVED CORROSION RESISTANT FLASHING AT EXTERIOR WALL ENVELOPE PER I.R.C. R-103.4 5. PROVIDE FLASHING AT ROOF PENETRATIONS PER I.R.C. 8903.2 4 8903.2.1 6• PROVIDE WEATHER STRIPPING At ALL EXTERIOR 4 GARAGE -INTERIOR DOORS. NEW WINDOWS AND DOORS TO BE MAX. U -VALUE OF 0.24. �• PROVIDE CONTINUOUS GUTTERS 4 DOWNSPOUTS a ALL EAVES, TYP. 8. ADDRESS OR HOUSE NUMBER TO BE POSTED AND PLAINLY VISIBLE FROM THE STREET FRONTAGE. MIN. 4" HEIGHT, 1/2" STROKE WIDTH AND CONTRASTING BACKGROUND. 9. PROVIDE STAIRWAY ILLUMINATION PER I.R.C. 83031 8 303.8 10, SEE SHEET Al FOR ADDITIONAL NOTES. 11. PROVIDE SURFACE DRAINAGE 6" : 10' MIN. AWAY FROM HOUSE FOOTPRINT IRC 8401.3 256.0' CONT. METAL GUTTER ON 5/4X8 FASCIA BOARD TYP. HARDIE LAP SIDING, TYPICAL 6" CORNER TRIM, TYP. HARDIE PANEL SIDING, TYP. MAIN FLOOR a 254.7' 2 54.0' L GAR. SLAB 9 253.2' GRADE PLANE a 252.3' 252.0' SOFFIT, VENT INSULATE (CANT'L 250.0' 1111/-30_INSULT NOTE: CONTRACTOR TO VERIFY ALL DIMENSIONS AND CONDITIONS OF PROJECT AND REPORT ANY OMISSIONS / DISCREPANCIES TO DESIGNER PRIOR TO COMMENCING WORK. DESIGNER SHALL NOT BE RESPONSIBLE FOR DISCREPANT CONDITIONS RESULTING FROM UNAUTHORIZED WORK PERFORMED BY THE CONTRACTOR. f;Rlr.xHT ELEVATION SCALE: 1/4" = 1'-0" -t2 4�j 4:12 MAIN FLOOR MAIN FLR. a 254.-l' 254.0' FINISH GRADE SLAB a 2532' 252.0' CONCRETE PATIO AVERAGE GRADE a 252.3' 250.0' MAX. ROOF HEIGHT a 282.3' TOP OF RIDGE 12 COMP. SHINGLES TYP 4 PL. a UPPER FLOOR HARDIE PANEL, OBSCURE SAFETY TYPICAL GLASS CEDAR SIDING, TYP. OR HARDIE LAP SIDING UPPER FLOOR PL. a MAIN FLOOR SOFFIT, VENT e INSULATE CANT'L W/ R-30 INSUL. LINE OF INTERIOR UPPER CABINETS KITCHEN CABINETS ILl _LINE OF INTERIOR- _ L IGHTWE IGHT STONE 3 IT-GHIEN-CQ-UN-TES' - VENEER, TYPICAL. 256.0' MAIN FLOOR MAIN FLOOR MAIN FLR. a 254.7' 254.0' FINISH GRADE SLAB a 253.2' 252.0' 1 2 AVERAGE GRADE a 252.3' A6 A6 250.0' 1 HR. RATED W o U U Ln °o s Z (P It Q) O v F � rn U Q) N WJW 0� W I Q x � Z_ s d ui Z Q LULn z� I�WZJ JJZOW V. O �^ o ?�MW W z o U Ln °o s L7 (P It Q) O v F � rn U Q) N 0� W q L Q x � Z_ s d ui Z Q LULn z� O �^ e N z �z z z tuz O m> x LU Lu a a � Q U ui >u � 0 � :Z N (L w ,&I= Project # : mmilb, EXTERIOR WALLS O GA FILE NO. WP 8104 PROPRIETARYt 1 HOUR GYPSUM WALLBOARD, FIRE FIBER -CEMENT BOARD, WOOD STUDS SEE DRILUNG AND EXTERIOR SIDE: Base layer 1/2" proprietary type X gypsum sheathing applied parallel to (P 2 x 4 wood studs 24" o.c. with 13/4" galvanized roofing nails 4" o.c. at vertical joints and NOTCFENG PROVISIONS top and bottom plates and 7" o.c. at intermediate studs. Face layer 5/16" x 12" wide maximum proprietary fiber -cement plank lap -applied at right angles to studs with 6d 5LCTION 8602,$.1 corrosion -resistant nails to each stud. O v INTERIOR SIDE: One layer 5/8" proprietary type X gypsum wallboard applied parallel to studs with 1 7/8" smooth round shank nails, 0.088" shank, 0.275" heads, 7" o.c. Thickness: 5 1/2" Joints staggered 24" on opposite sides. (LOAD-BEARING) Approx. Weight: 6 psf PROPRIETARY GYPSUM BOARD Fire Test: OPL 11710-98414, 5-1-95 CertainTeed Gypsum, Inc. 1/2" PrOROCTM Sheathing Type C 5/8" PrOROCTm Type X Gypsum Panels moicgN5 Pncvitiow tContact the manufacturer for more detailed information on proprietary products. s d 1 1�4R. FIRE RATED UJALLe SECTION 8642,9 FLOOR -CEILING SYSTEMS, WOOD -FRAMED wIQ GA FILE NO. FC 5105 PROPRIETARYt 1 HOUR 55 to 59 STC GYPSUM WALLBOARD, RESILIENT CHANNELS, WOOD JOISTS FIRE SOUND One layer 1/2" proprietary type X gypsum wallboard or gypsum veneer base applied at right n, angles to resilient furring channels 24" o.c. with 1" Type S drywall screws 12" o.c. Gypsum O "z board end joints located midway between continuous channels and attached to additional pieces of channel 60" long with screws 12" o.c. Resilient channels applied at right angles to 2 x 10 0 N wood joists 16" o.c. with 6d common nails. Wood joists supporting 19/32" plywood and 1" proprietary sanded gypsum underlayment. MMMM4 -------------- STC rated with 3 1/2" glass fiber insulation in joist spaces and with carpet and pad. Second JpIST NAI LEC T4 layer of 1/2" or 5/8" type X gypsum wallboard required to achieve 1 hour fire resistance X LU rating when glass fiber insulation is used. STUD a Approx. Ceiling PROPRIETARY GYPSUM BOARD Weight: 2 psf American Gypsum Company 1/2" TYPE X PLUS Fire Test: UL R6352, 4-21-71, CertainTeed Gypsum, Inc. 1/2" ProROCTM Type C Gypsum Panels 1/2" UL Design L502 G -P Gypsum ToughRock® Fireguard® C Sound Test: G&H BW -10 MT, 10-13-70 Lafarge North America Inc. 1/2" Firecheck® Type C I IC & Test: (73 C & P) National Gypsum Company 1/2" Gold Bond® Brand FIRE -SHIELD CTM G&H BW -10 MT, 10-13-70 Gypsum Wallboard PABCO Gypsum 1/2" FLAME CURB® Super'C' SEE SECTION WZE; Temple-Inland Forest Products Corporation 1/2" FIRE -RATED "T" tContact the manufacturer for more detailed information on proprietary products. N 2 1�4R, FLOOR FRAM Il l R4FTERSAND CEILING J01575 OR APPROVED row rnL" f O TOP PLATE - TOP PLATE `n O SEE DRILUNG AND Z (P NOTCFENG PROVISIONS uJ 5LCTION 8602,$.1 O L O v SECONDSTORY 0 WALL STUD_ WJ� 0� JOIST IS PERMITTED TO SEE DRILLING AND D BE GUT COR NUTCHEC moicgN5 Pncvitiow Iz z s d FLOOR JOIST- BETWEEN THESE LIM" SECTION 8642,9 z wIQ SEE UNQ AND Ln J�'ZOW r NCTGHI E3PFlUVI NOTGHIPI4 PRWISIONS n, O "z SECTION F11502.8 BOT79M PLATE 0 N '14 SPAN'+ SPAM I I ' JpIST NAI LEC T4 X LU LU STUD a �a Q JL T TOP PLATE BAND JCI ST CA FQR 0LQCeK1 NQ AND 1 IN. � E LOCKI NG BRIDGING- SEE UTIN. 14 TUU -RIBBON SECTION Rb02.7 SEE SECTION WZE; E AR NCS WALL LAP JOIST 3 IN. MIN - BAND JOIST 90TTOM PLATE OR SON R5q 9 1 P1_110E SEE SEE SECTION R2.B OR BLOCKING/ I / FQR FIRE BLOCKING SILL PLATE JOIST CRAWL SPACE OR SUSFLOOR ASEMEN7 �* FOUNDATION IN'TERMEDIATE PLArrortM F nA 411 MG EEA FII NG WALL 4X4 DF 02 P05T AT 8FT O.C. ATTACHED TO 2X12 JOISTS LU/ (2)y' DIA. x 6' LONG THRU BOLTS LU/ NUT AND LUASHERS ---_ CONTINUOUS 2X12 RIM - _ JOIST �Q N 5IMP50N A34 POST TO TOP PLATE 2X12 FLR - JSTS e 16' O.C. MONOLITHIC SLAG-ON-GFIAOE FOUNDATION 9ALL55N FrIAWNG lmd COMMON NAILS BOTH SIDES STAGGERED AT 6' O.G. 1 ) SECTION - �4AL1= UUALL FRAM IN 256.0' MAX. ROOF HEIGHT a 282.3' _TOP OF RIDGE 12 MAIN FLOOR a 254.1' -� 254.0' -GAR. SLAB a 253.2' GRADE PLANE a 252.3' CONCRETE DRIVEWAY 252.0' - 2015 IRC SECTION 8302.11 FIREBLOCKING. IN COMBUSTIBLE CONSTRUCTION, FIREBLOCKING SHALL BE PROVIDED TO CUT OFF ALL CONCEALED DRAFT OPENING6(50T1H VERTICAL AND HORIZONTAL) AND TO FORM AN EFFECTIVE FIRE BARRIER BETWEEN STORIES, AND BETWEEN A TOP STORY AND THE ROOF SPACE, FIREBLOCKING SHALL BE PROVIDED IN WOOD -FRAME CONSTRUCTION IN THE FOLLOWING LOCATIONS: 1) IN CONCEALED SPACES OF STUD WALLS AND PARTITIONS, INCLUDING FURRED SPACES AND PARALLEL ROWS OF STUDS OR STAGGERED STUDS AS FOLLOWS: A) VERTICALLY AT THE CEILING AND FLOOR LEVELS. B) HORIZONTALLY AT INTERVALS NOT EXCEEDING 10 FEET. 2) AT ALL INTERCONNECTIONS BETWEEN CONCEALED VERTICAL AND HORIZONTAL SPACES SUCH AS OCCUR AT SOFFITS, DROP CEILINGS AND COVE CEILINGS. 3) IN CONCEALED SPACES AT STAIR STRINGERS AT THE TOP AND BOTTOM OF THE RUN. ENCLOSED SPACES UNDER STAIRS SHALL COMPLY WITH SECTION R302.1, 4) AT OPENINGS AROUND VENTS, PIPES, DUCTS, GABLES AND WIRES AT CEILING AND FLOOR LEVEL, WITH AN APPROVED MATERIAL TO RESIST THE FREE PASSAGE OF FLAME AND PRODUCTS OF COMBUSTION. THE MATERIAL FILLING THIS ANNULAR SPACE SHALL NOT BE REQUIRED TO MEET THE ASTM E 136 REQUIREMENTS. 5) FOR THE FIREBLOCKING OF CHIMNEYS AND FIREPLACES, SEE SECTION 81003.19. 6) FIREBLOCKING OF CORNICES OF A TWO-FAMILY DWELLING IS REQUIRED AT THE LINE OF DWELLING UNIT SEPARATION. FIRE BLOCKING MATERIALS SHALL CONSIST OF MATERIAL LISTED IN SECTION 8302.11.1. LOOSE -FILL INSULATION MATERIAL SHALL NOT BE USED AS A FIREBLOCK UNLESS SPECIFICALLY TESTED IN THE FORM AND MANNER INTENDED. THE INTEGRITY OF ALL FIREBLOCKS SHALL BE MAINTAINED. DRAFTSTOPPING: WHEN THERE IS USABLE SPACE BOTH ABOVE AND BELOW A CONCEALED SPACE OF A FLOOR/CEILING ASSEMBLY, DRAFTSTOPS SHALL BE INSTALLED SO THAT THE AREA OF THE CONCEALED SPACE DOES NOT EXCEED 1000 SQUARE FEET. DRAFTSTOPS SHALL DIVIDE THE CONCEALED SPACE INTO APPROXIMATELY EQUAL AREAS. DRAFTSTOPPING MATERIALS SHALL CONSIST OF MATERIALS LISTED IN SECTION R302.12.1. DRAFTSTOPPING MATERIALS SHALL NOT BE LESS THAN INCH GYPSUM, 3/0 INCH WOOD STRUCTURAL PANELS OR OTHER APPROVED MATERIALS ADEQUATELY SUPPORTED. THE INTEGRITY OF THE DRAFTSTOPS SHALL BE MAINTAINED. 2X6 16' O.C. STUD HALF-LUALL Imd COMMON NAILS STAC<3ERE1) INFILL U1/ CONTINUOUS 2X6 CAP AT 6" O.C. PLATE. TO TQP PLATE QRST 6 MIL (BLACK) V.B. LINE OF POST 6 BEAM BEYOND SEE FOUNDATION PLAN FOR MEMBER DIMENSIONS f5UILIDING CROSS-SECTION 'A' SCALE: 1/4" = l'-0" SECTION 312.12: RODENT PROOFING: STRAINER PLATES ON DRAIN INLETS SHALL BE DESIGNED AND INSTALLED SO THAT NO OPENING EXCEEDS 1/2 OF AN INCH IN THE LEAST DIMENSION. 312.12.1: METER BOXES SHALL BE CONSTRUCTED IN SUCH A MANNER THAT RATS CANNOT ENTER A BUILDING BY FOLLOWING THE SERVICE PIPES FROM THE BOX INTO THE BUILDING. 312.12.2: METAL COLLARS. IN OR ON BUILDINGS WHERE OPENINGS HAVE BEEN MADE IN WALLS, FLOORS, OR CEILINGS FOR THE PASSAGE OF PIPES, SUCH OPENINGS SHALL BE CLOSED AND PROTECTED BY THE INSTALLATION OF APPROVED METAL COLLARS SECURELY FASTENED TO THE ADJOINING STRUCTURE. 312.12.3: TUB WASTE OPENINGS. TUB WASTE OPENINGS IN FRAMED. CONSTRUCTION TO CRAWL SPACES AT OR BELOW THE FIRST FLOOR SHALL BE PROTECTED BY THE INSTALLATION OF APPROVED METAL COLLARS OR METAL SCREEN SECURELY FASTENED TO THE ADJOINING STRUCTURE WITH NO OPENING GREATER THAN 1/2 OF AN INCH IN THE LEAST DIMENSION. 2015 UNIFORM PLUMBING CODE WITH WASHINGTON STATE AMENDMENTS (UPC) ;ONT. DBL- TOP PLATE R-10 RIGID INSULATION EXTERIOR SIDE OF WALL SHADED AREA) �X HEADER KING STUD EXTERIOR PLYWOOD TRIMMER U NOTE: REFER TO STRUCTURAL SHEETS FOR SHEAR WALL SCHEDULE AND ENGINEERING PLAN WHICH CONTAIN REFERENCES AND/OR INSTRUCTIONS PERTAINING TO EACH SHEAR WALL INDICATED IN THIS PLAN NOTE: CONTRACTOR TO VERIFY ALL DIMENSIONS AND CONDITIONS OF PROJECT AND REPORT ANY OMISSIONS / DISCREPANCIES TO DESIGNER PRIOR TO COMMENCING WORK. DESIGNER SHALL NOT BE RESPONSIBLE FOR DISCREPANT CONDITIONS RESULTING FROM UNAUTHORIZED WORK PERFORMED BY THE CONTRACTOR. MAIN FLOOR �) H AIDR/INSLS LATION DETAIL ( 3 ) COFF R D C;ILIN NOT TO SCALE TYPICAL ROOF CONSTRUCTION ARCH. LAM. COMP. ROOFING OVER 15# ROOFING FELT OVER]/2" CDX OR 1/16" OSB SHIT'G (CCX PLYWD AT EXPOSED EAVES) MFG. ROOF TRUSSES a 24" O.C. MAX. ROOF HEIGHT a 282.3' TOP OF RIDGE TOP OF RIDGE COMPOSITION SHINGLES OVER 1/2" CDX OR O.S.B. OVER 151b FELT OVER TRUSSES INSULATION BAFFLE VENTED 5LOC<ING MAXIMUM WALL PLATE e 216.3' PL. a UPPER FLOOR CONTINUOUS GUTTER OVER 8" FASCIA 2x6 STUDS 16" O.G. W/ R-21 INSULATION TYP. FINISH PER ELEVATION OVER 1" CDX OR O.S.B. OVER 15110 FELT OVER 3/4" T. 4 G. PLYWOOD OVER 11 1/8 TJI/230 FLOOR JOISTS UPPER FLOOR PL. a MAIN FLOOR R-21 INSUL. FINISH PER ELEVATION OVER 1" CDX OR O.S.B. OVER 151b FELT OVER 2x6 STUDS 16" O.G. W/ R-21 INSULATION TYP. 3/4" T. 8 G. PLYWOOD OVER 2x10 FLOOR JOISTS W/ R-30 INSULATION MAIN FLOOR FINISH GRADE o L 11 256.0' -MAIN FLR. a 254.1' 254.0' -SLAB a 253.2' 252.0' ■ L - AVERAGE GRADE a 252.3' 0 250.0' L a ^L LL R OUB I R ID 54F T� GLAZING L OCAT I CNe'. 1. GLAZING IN SWINGING DOORS EXCEPT LOUVERED WINDOWS AND JALOUSIES COMPLYING WITH IRC 8308.2. 2. GLAZING IN FIXED AND SLIDING PANELS OF SLIDING DOOR ASSEMBLIES AND PANELS IN SLIDING AND BIFOLD CLOSET DOOR ASSEMBLIES. 3. GLAZING IN STORM DOORS. 4. GLAZING IN ALL UNFRAMED SWINGING DOORS 5. GLAZING IN DOORS, WALLS, FENCES AND ENCLOSURES FOR HOT TUBS, WHIRLPOOLS, SAUNAS, STEAM ROOMS, BATHROOMS, AND SHOWERS, GLAZING IN ANY PORTION OF A BUILDING WALL ENCLOSING THESE COMPARTMENTS WHERE THE BOTTOM EXPOSED EDGE OF THE GLAZING IS LESS THAN 60" ABOVE ANY STANDING OR WALKING SURFACE. EXCEPTION: OPENINGS THROUGH WHICH A 3" SHPERE IS UNABLE TO PASS. 6. GLAZING IN FIXED OR OPERABLE PANELS ADJACENT TO A DOOR WHERE THE NEAREST VERTICAL IS WITHIN A 24" ARC OF EITHER VERTICAL EDGE OF THE DOOR IN A CLOSED POSITION AND WHERE THE BOTTOM EXPOSED EDGE OF THE GLAZING IS LESS THAN 60" ABOVE THE WALKING SURFACE. EXCEPTION: WHERE THERE IS AN INTERVENING WALL OR PARTITION BETWEEN DOOR AND GLAZING OR WHERE THE DOOR ACCESSES A CLOSET 3' OR LESS IN DEPTH. 1. GLAZING IN AN INDIVIDUAL FIXED OR OPERABLE PANEL, WHEN ALL OF THE FOLLOWING APPLY: 1.1 EXPOSED AREA OF AN INDIVIDUAL PANE GREATER THAN 9 S.F. 1.2 BOTTOM EDGE LESS THAN 18" ABOVE THE FLOOR. 1.3 TOP EDGE GREATER THAN 36" ABOVE THE FLOOR. 1.4 ONE OR MORE WALKING SURFACES WITHIN 36" HORIZONTALLY OF THE GLAZING. EXCEPTION: WHERE A PROTECTIVE 1 -1/2" -WIDE BAR IS INSTALLED ON THE ACCESSIBLE SIDE OF THE GLAZING 34" - 35" ABOVE THE FLOOR AND IS CAPABLE OF WITHSTANDING A LOAD OF 50 LBS PER LINEAL FOOT OR WHERE THE BOTTOM EDGE OF THE GLASS IS 25' OR MORE ABOVE GRADE, A ROOF, WALKING SURFACE, OR OTHER HORIZONTAL SURFACE. 0. GLAZING IN RAILINGS REGARDLESS OF AREA OR HEIGHT ABOVE A WALKING SURFACE. INCLUDES STRUCTURAL BALUSTER PANELS AND NONSTRUCTURAL IN -FILL PANELS. 9. GLAZING IN WALLS AND FENCES ENCLOSING INDOOR AND OUTDOOR SWIMMING POOLS, HOT TUBS, AND SPAS WHERE THE BOTTOM EDGE OF THE GLAZING IS LESS THAN 60" ABOVE A WALKING SURFACE AND WITHIN 60" HORIZONTALLY OF THE WATER'S EDGE. THIS WILL APLY TO ALL SINGLE GLAZING AND ALL PANES IN MULTIPLE GLAZING. 10. 8308.4.6 GLAZING ADJACENT TO STAIRS AND RAMPS. GLAZING WHERE THE BOTTOM EXPOSED EDGE OF THE GLAZING IS LESS THAN 36 INCHES (914 MM) ABOVE THE PLANE OF THE ADJACENT WALKING SURFACE OF STAIRWAYS, LANDINGS BETWEEN FLIGHTS OF STAIRS AND RAMPS SHALL BE CONSIDERED TO BE A HAZARDOUS LOCATION. EXCEPTIONS: 1. WHERE A RAIL IS INSTALLED ON THE ACCESSIBLE SIDE(S) OF THE GLAZING 34 TO 38 INCHES (864 TO 965 MM) ABOVE THE WALKING SURFACE. THE RAIL SHALL BE CAPABLE OF WITHSTANDING A HORIZONTAL LOAD OF 50 POUNDS PER LINEAR FOOT (130 N/M) WITHOUT CONTACTING THE GLASS AND HAVE A GROSS -SECTIONAL HEIGHT OF NOT LESS THAN 11/2 INCHES (38 MM). 2. GLAZING 36 INCHES (914 MM) OR MORE MEASURED HORIZONTALLY FROM THE WALKING SURFACE. 11. 8308.4.1 GLAZING ADJACENT TO THE BOTTOM STAIR LANDING. GLAZING ADJACENT TO THE LANDING AT THE BOTTOM OF A STAIRWAY WHERE THE GLAZING IS LESS THAN 36 INCHES (914 MM) ABOVE THE LANDING AND WITHIN A 60 -INCH (1524 MM) HORIZONTAL ARC LESS THAN 180 DEGREES FROM THE BOTTOM TREAD NOSING SHALL BE CONSIDERED TO BE A HAZARDOUS LOCATION. EXCEPTION: THE GLAZING IS PROTECTED BY A GUARD COMPLYING WITH SECTION 8312 AND THE PLANE OF THE GLASS 16 MORE THAN 18 INCHES (451 MM) FROM THE GUARD. W O U U `n O S Z (P uJ O L O v 0 N WJ� 0� W I D z Iz z s d Lu z wIQ Q Ln J�'ZOW r n, O "z Z?00WQ 0 N IL E z_ O U `n O S L7 (P uJ >Y Lu O v 0 N 0� W a L D z Iz z s d Lu z wIQ Q Ln Lu z n, O "z 0 N z_ IY uJ >Y Lu Z w0 Z Iz z z Lu z O "z X LU LU a a �a U LTi LTi � 0 � N JN LU N (Y/ ,&I= Project # 17170 Sheet A6 1 1/4" DIA. MIN. HANDRAIL, CONT. FOR FULL LENCxTH OF STAIR L J GUARDRAIL MEMBERS TO BE SUCH THAT A SPHERE OF 4" DIA. SHALL NOT PASS THROUGH ANY OPENING --HANDRAILS PER IRC 8311.7.7 BALUSTERS TO CONFORM TO IRC R312.2 Z O W 36" MIN- STAIRWAY WIDTH } PER IRC R311.7.1 O \\ 16d � 4" O.G. 10" MIN. TREAD 51MP50N SLOPED HUC20 OR EQUAL BEAM PER PLAN BELOW STAIR INSTALL 1/2" G.W.B. @ CEILING k WALLS (3) 2X12 STRINGERS FIRE BLOCKING la MID -SPAN 2X4 THRUST NOTE: GREATEST AND LEAST TREAD BLOCK RISER SHALL NOT VARY MORE THAN 3/8" (PER IRC 8311-7-4.1 8311.7.4.2) -(3) 3c' TOE NAIL STRINGER TO THRUST BLOCK - JOIST OR BLOCKING a FLOOR BELOW NOT TO SCALE WIN S _ ow HANDRAIL I_" PART. BD. BULLNOSE TREADS GLUED & SCREWED (INSTALL AFTER ROOF ON) \\\ "SIMPSON" Ls56 EA. SIDE V PLYWOOD RISERS (3) 2 X 12 STRINGERS Y TYPE "X" G.W.B. TYP. UNDER STAIR �) 5T,41 4 fRAILING E)TAIL INSULAT 2X 5TUG PER PL 1/2" CDX 5HiEATH 2 LAYEF BLDG- F RESIST,Z GQRRQ: R!=515TH METAL t ADHERE TYPE "N MORTAF TYPE "N SEATINC HANDGRIP SECTION BTWN IV' & 2" Al HANDRAIL BALLUSTER OR PARTITION (VERIFY STYLE) SHOE RAIL FOR BALLUSTERS NOSING OF TREAD 2 X 12 STRINGER 2 X BLOCKING 26 GA GAL V. CORROSION - RE5157ANT WEEP m SGREED-OVERLAP BLDG. z PAPER -LATH TO COVER TERMINATE ON FLANGE FOUNDATION WALL 4" MIN. (5GREED TO GRADE) 2" MIN. (5GREED TO PAVEMENT) 3 EAR rn SCALE 3/4" = 1'-0" a' ° a ° 4" MIN. ABOVE THE EARTH, 2" MIN. ABOVE PAVED AREAS,AND 2" MINIMUM ABOVE EXTERIOR WALKING a SURFACES, PER IRC R-103.12.1. a° ° 4 Z3 a NOT TO 5GALE VENTILATION SCHEDULE 2015 WASHINGTON STATE ENERGY CODE M1507.3.3(1) &(2) SYMBOL LOCATION MINIMUM FAN REQUIREMENTS WDW. Bath, Powder, Min. 50 cfm @ 0.25" WG A Laundry U-VAL. AREA Kitchen Min. 100 cfm @ 0.25" WG B W. (Range hood or down draft exhaust fan rated at min. 100 cfm Instructions No Vaulted Ceilings in this project. TYPE at 0.10" WG may be used for exhaust fan requirement.) NO. Whole House MIN. CFM = 105 MAX. CFM = NO MA M1507.3.3(1) C Fan (based on 3,133 s.f. floor area & 6 bedrooms) X MAIN FLOOR *flow rating @ 0.25" WG 1 5.00 8.00 MILGARD VINYL *whole house fans located 4 ft. or less from interior grille to 1/2" AIR YES 0.24 40.00 have a sone rating of 1.0 or less measured @ 0.1" WG, FOYER 1 5.00 3.00 MILGARD per IRC M1507.3.4 PICTURE 5320 1/2" INTERMITTENT WHOLE -HOUSE MECAHNICAL VENTILATION 3.60 Instructions PER M1507.3.3(2) VINYL PICTURE 5320 105 CFM X 1.5 (66%) = 157.5 CFM INTERMITTENT WHOLE - AIR YES 0.24 36.00 8.64 HOUSE FAN AT 66% (1.5 FACTOR) RUNTIME PERCENTAGE - 864.90 s.i. IS GREATER THAN: IN EACH 4 -HOUR SEGMENT PER M1507.3.3(2) *All fans to vent to outside *All other requirements of 2015 IRC 2015 WHOLE HOUSE VENTILATION OPTION 1 - INTERMITTEN WHOLE HOUSE VENTILATION USING EXHAUST FANS A. * 105 CFM EXHAUST FAN FLOW RATING PER TABLE M1508.2 * FAN CONTROLS: 24 HOUR CLOGK TIMER WITH CAPACITY OF CONTINUOUS OPERATION, MANUAL AND AUTOMATIC CONTROL $ ACCESSIBLE. * WHOLE HOUSE FANS LOCATED 4 FEET OR LESS FROM THE INTERIOR GRILLE SHALL HAVE A SONE RATING OF 1.0 OR LE55 AT 0.1 INCHES W.G. * OUTDOOR AIR SHALL BE DISTRIBUTED TO EACH HABITABLE ROOM BY INDIVIDUAL OUTDOOR AIR INLETS. WHERE OUTDOOR AIR SUPPLIES ARE SEPARATED FROM EXHAUST POINTS BY DOORS, PROVISIONS SHALL BE MADE TO ENSURE AIR FLOW BY INSTALLING OF DISTRIBUTION DUCTS, UNDERCUTTING DOORS, GRILLES, TRAN50ME15, OR SIMILAR MEANS. DOORS SHALL BE UNDERCUT A MINIMUM OF 1/2" ABOVE FLOOR COVERING 105 CFM X 1S ((06%) 15 .5 CFM INTERMITTEN WHOLE -HOUSE FAN 6 66% (1.5 FACTOR) RUNTIME PERCENTAGE IN EACH 4 -HOUR SEGMENT PER IRC M1507.3.3(2). * INTERMITTENT WHOLE -HOUSE MECHANICAL VENTILATION RATE PER TABLE IRC M1501.3.3(2) NOTE: CONTRACTOR TO VERIFY ALL DIMENSIONS AND CONDITIONS OF PROJECT AND REPORT ANY OMISSIONS / DISCREPANCIES TO DESIGNER PRIOR TO COMMENCING WORK. DESIGNER SHALL NOT BE RESPONSIBLE FOR DISCREPANT CONDITIONS RESULTING FROM UNAUTHORIZED WORK PERFORMED BY THE CONTRACTOR. mow \ccessories for Horizonta lent through the wall Horizontal Discharge Termination 12" or 21" Depending on Wall thickness May insert Vent between Ell and Tankless or Ell can install at top of Tankless 3/4" X 24" Gas Flex Connector NOTE: * ENERGY STAR QUALIFIED * ENERGY FACTOR OF .96 FOR BOTH NATURAL GAS AND PROPANE * CERTIFIED FOR INSTALLATION IN MANUFACTURED (MOBILE) HOMES * ENHANCED SCALE DETECTION LESSENS POSSIBILITY OF SERIOUS, LONG-TERM DAMAGE TO UNIT * TEMPERATURE LOCK FUNCTION PREVENTS ACCIDENTAL OR UNAUTHORIZED CHANGES TO WATER TEMPERATURE * COMPLIES WITH SOUTH COAST AIR QUALITY MANAGEMENT DISTRICT 14 NG/J OR 20 PPM NOX EMISSION LEVELS NOT TO SCALE GLAZING SCHEDULE ROOM # OFWND. 9.5 WND. MAN LIF. FRAME WDW. MODEL AIR GAS LO -E U-VAL. AREA UA U -Factor WNDS. W. H. Instructions No Vaulted Ceilings in this project. TYPE TYPE NO. GAP LOCATE ONE VENT WITHIN 3 FEET OF EACH CORNER OF THE BUILDING Above Grade Walls (see Figure 1) (1) U -Factor X MAIN FLOOR FOYER 1 5.00 8.00 MILGARD VINYL PICTURE 5320 1/2" AIR YES 0.24 40.00 9.60 FOYER 1 5.00 3.00 MILGARD VINYL PICTURE 5320 1/2" AIR YES 0.24 15.00 3.60 Instructions 2 3.00 6.00 MILGARD VINYL PICTURE 5320 1/2" AIR YES 0.24 36.00 8.64 DEN/BD - 864.90 s.i. IS GREATER THAN: 842.88 &1. Req'd Below Grade Walls (see Figure r) Figure t) 1 8.00 6.00 MILGARD VINYL SLIDER 5120 1/2" AIR YES 0.24 48.00 11.52 GREAT RM. 1 8.00 8.00 MILGARD VINYL S.G.D. 5621 1/2" AIR YES 0.24 64.00 15.36 GREAT RM. 1 8.00 6.00 MILGARD VINYL SLIDER 5120 112" AIR YES 0.24 48.00 11.52 I --- 1 8.00 6.00 MILGARD VINYL SLIDER 5120 112" AIR YES 0.24 48.00 11.52 DINING Length UA Instructions No Slab on Grade In this project, I --- 1 6.00 6.00 MILGARD VINYL SLIDER 5120 1/2" AIR YES 0.24 36.00 8.64 KITCHEN 1 6.00 1.00MILGARD VINYL PICTURE 5320 1/2" AIR YES 0.24 6.00 1.44 CORRIDOR 1 2.00 5.00 MILGARD VINYL PICTURE 5320 1/2" AIR YES 0.24 10.00 2.40 STAIRWELL 1 5.00 3.50 MILGARD VINYL 1PICTURE 5320 1/2" IAIR YES 0.24 1 17.50 4.20 UPPER FLOOR FOYER 1 5.00 3.00 MILGARD VINYL PICTURE 5320 1/2" AIR YES 0.24 15.00 3.60 STAIRWELL 2 5.00 3.50 MILGARD VINYL PICTURE 5320 1/2" AIR YES 0.24 35.00 8.40 1 8.00 6.00 MILGARD VINYL SLIDER 5120 1/2" AIR YES 0.24 48.00 11.52 BONUS 1 8.00 8.00 MILGARD VINYL S.G.D. 5621 1/2" AIR YES 0.24 64.00 15.36 W.I.C. 1 4.00 2.00 MILGARD VINYL PICTURE 5320 1/2" AIR YES 0.24 8.00 1.92 M. BATH 1 3.00 5.00 MILGARD VINYL PICTURE 5320 1/2" AIR YES 0.24 15.00 3.60 1 8.00 6.00 MILGARD VINYL SLIDER 5120 1/2" AIR YES 0.24 48.00 11.52 M.SUITE 1 8.00 2.00 MILGARD VINYL PICTURE 5320 1/2" AIR YES 0.24 16.00 3.84 LAUNDR': 1 3.00 5.00 MILGARD VINYL CASE. 5521 1/2" AIR YES 0.24 15.00 3.60 BEDRM. #2 1 8.00 6.00 MILGARD VINYL SLIDER 5120 1/2" AIR YES 0.24 48.00 11.52 BEDRM. #3 1 6.00 6.00 MILGARD VINYL SLIDER 5120 1/2" AIR YES 0.24 36.00 8.64 1 3.00 2.00 MILGARD VINYL PICTURE 5320 1/2" AIR YES 0.24 6.00 1.44 BEDRM. #4 1 8.00 6.00 MILGARD VINYL SLIDER 5120 1/2" AIR YES 0.24 48.00 11.52 WND. TOTAL: 770.50 184.92 DOORS WITH MORE THAN 50% GLASS DOORS WITH MORE THAN 50% GLASS -TOTAL:' AVG. U -VALUE (VERTICAL GLASS): SKYLIGHTS AND SKYWALLS SKYLIGHT TOTAL: #REF! AVG. U -VALUE (OVERHEAD GLASS): AREA UA r7_7_05_0F 184.92 TOTAL 1 TOTAL 2 pr GLAZING % = TOTAL 1 = 770.50 S. F. = 24.59% HEATED AREA 3133.00 S. F. AVG. U -VALUE = UA TOTAL (TOT. 2) = 184.92 UA = 0.24 U -VALUE AREA TOTAL (TOT. 1) 770.50 A (1) U -VALUES ARE NFRC CERTIFIED OR OBTAINED FROM WSEC TABLE 10-6A, B, C, D OR E Per WSEC R402.4, The bui Id ing thermal Envelope shall be constructed to limit air leakage. The results of the test shall be signed by the party conducting the test and provided to the code official (8402.4.1.2). Per W5EC 8403.1.1, at least one thermostat per dwelling unit shall be capable of controlling the heating and cooling system on a daily schedule. Per WSEC 8403.2.2, Ducts, air handlers, and filter boxes shall be sea led. Per WSEC R404.1, A minimum of 75 percent of the lamps in permanently installed lighting fixtures shall be high -efficacy lamps. DUCTS (503.10.1) * INSTALLATION OF DUCTS IN EXTERIOR WALLS, FLOOR OR CEILING CANNOT DISPLACE REQUIRED INSULATION. * BUILDING CAVITIES CANNOT BE USED AS DUCTS DUCT TESTING (503.10.2) * DUCTS LOCATED OUTSIDE THE CONDITIONED SPACE MUST BE TESTED. SimDle Heatina Svstem Size: Washinaton State The glazing (window) and door portion of this calculator assumes the installed glazing and door products have an area weighted average U -factor of 0.30. The incorporated insulation requirements are the minimum prescriptive amounts specified by the 2015 WSEC. Please fill out all of the green drop -downs and boxes that are applicable to your project. As you make selections in the drop -downs for each section, some values will be calculated for you. If you do not see the selection you need in the drop-down options, please call the WSU Energy Extension Program at (360) 956-2042 for assistance. Project Information Contact Information URBAN DESIGN GROUP 206-838-8250 Heating System Type: O All Other systems O Heat Pump To see detailed instructions for each section, place your cursor on the word "Instructions" Design Temperature Instructions Design Temperature Difference (AT) 46 Renton 11 AT= Indoor (70 degrees) -Outdoor Design Temp Area of Building Conditioned Floor Area Instructions Conditioned Floor Area (sq ft) Average Ceiling Height Instructions Average Ceiling Height (ft) Glazing and Doors Instructions Skylights Instructions 3,133 Attic Conditioned Volume 9.5 29,764 U -Factor X Area = UA 0.30 771 231.15 UI -Factor X Area = UA 0.50 - Attic o UI -Factor X Area = UA Instructions R-49 38,504 Btu / Hour 0.026 s.i. 1 1,756 45.66 Single Rafter or Joist Vaulted Ceilings _ s.i. U -Factor X Area UA Instructions No Vaulted Ceilings in this project. INSTALL 6 MIL BLACK POLYETHYLENE VAPOR RETARDER GROUND COVER --- LOCATE VENTS SO AS TO PROVIDE CROSS -VENTILATION OF CRAWL SPACE F LOCATE ONE VENT WITHIN 3 FEET OF EACH CORNER OF THE BUILDING Above Grade Walls (see Figure 1) NO OPERABLE LOUVERS AT VENTS U -Factor X Area UA Instructions R-21 Intermediate z I 0.056 49 s.i. each - 25% screen reduction = 3,314 185.58 Floors 11.47 vents U -Factor X Area UA Instructions R-30 Use: (minimum) I 0.029 423.90 s.i. 1,835 53.22 441.00 s.i. - 864.90 s.i. IS GREATER THAN: 842.88 &1. Req'd Below Grade Walls (see Figure r) Figure t) Lu UI -Factor X Area UA Instructions No Below Grade Walls in this project. LU --- - Slab Below Grade{ (see Figure t) F -Factor X Length UA Instructions I No Slab Below Grade In this project. aN I --- a- N Slab on Grade (see Figure 1) F -Factor X Length UA Instructions No Slab on Grade In this project, I --- Location of Ducts Instructions - Duct Leakage Coefficient L Unconditioned Space 1 1.10 Sum of UA 515.61 Envelope Heat Load 23 718 Btu / Hour Figure 1. Sum of UA X AT o Air Leakage Heat Load 14,787 Btu / Hour VolumeX 0.6XATX.018 s.i. Req'd Building Design Heat Load 38,504 Btu / Hour Air Leakage + Envelope Heat Loss s.i. Building and Duct Heat Load 42,355 Btu / Hour Ducts in unconditioned space: Sum of Building Heat Loss X 1.10 Ducts in conditioned space: Sum of Building Heat Loss X 1 Maximum Heat Equipment Output 59,297 Btu / Hour Building and Duct Heat Loss X 1.40 for Forced Air Furnace Building and Duct Heat Loss X 1.25 for Heat Pump FOUNDATION VENTILATION o Crawlspace Area: 1317 s.f. Standard Truss/ Scissor Truss Roof Framing Assembly: Ventilation Required: 1317 s.f. / 150 = 632.16 s.i. Req'd Use- 14" x 7" Foundation Vents 1756 s.f. Vent Area = 98 s.1. - 25% reduct.,1/4"mesh = 73.5 s.i. Vents Required= 632.16 s.i. / Vent Area = 8.60 s.i. '1 Provide . 9 14 x 7 Vents, Area = 661.5 s.i. Ventilation Provided = 661.50 s.i. is Greater than 632.16 s.i. Req'd Use: 9 14" x 7" Foundation Vents O v FOUNDATION VENTS SHALL NOT INTERFERE WITH DIRECT LOAD PATH OF COLUMNS INSTALL 6 MIL BLACK POLYETHYLENE VAPOR RETARDER GROUND COVER 3.53 s.i. / I.f. LOCATE VENTS SO AS TO PROVIDE CROSS -VENTILATION OF CRAWL SPACE 842.88 s.i. / 2 / s.i. per I.f. = LOCATE ONE VENT WITHIN 3 FEET OF EACH CORNER OF THE BUILDING Provide : NO OPERABLE LOUVERS AT VENTS 423.90 s.i. ROOF VENTILATION o MAIN ROOF Standard Truss/ Scissor Truss Roof Framing Assembly: U `n o Roof Area : 1756 s.f. Z Ventilation Required: 1756 s.f. x 144 s.i. / s.f. / 300 = 842.88 s.i. Req'd Provide 112 ventilation at eaves, 1/2 abo\e midpoint & min. 3 ft. above eave vents Eave Ventilation: >Y Z O v Birdblocking = 4.71 s.i. / I.f. - 25% reduction = 3.53 s.i. / I.f. Eave Ventilation Req'd = 842.88 s.i. / 2 / s.i. per I.f. = 119.30 I.f. Provide : 120 I.f. birdblocking. Ventilation = 423.90 s.i. Min. Ventilation Provided = 423.9 s.i. is greater than 421.44 s.i. Req'd Upper Roof Ventilation: Z z 7x7" Attic Roof Jack = 49 s.i. each - 25% screen reduction = 36.75 s.i. each. Upper Ventilation Req'd = 842.88 s.i. / 2 / s.i. of each vent = 11.47 vents Provide: 12 -7"x7" roof jacks. Ventilation = 441.00 s.i. Ventilation Provided = 441.00 s.i. is greater than 421.44 s.i. Req'd Use: (minimum) 120 Lf. birdblocking. Ventilation = 423.90 s.i. Use: (minimum) 12 -7"x7" roof jacks. Ventilation = 441.00 s.i. Total Min. Ventilation Provided = 864.90 s.i. IS GREATER THAN: 842.88 &1. Req'd U 0 L 0 a L W o U U `n o Z �@ _q It .. w >Y Z O v 0 W_ Q) N WJW�I 0� W a� I � Q Z z a LU Z wIQ Q Z� I�WZJ JJZOW r �U�ZrY O Z?00WQ 0J��� e N z o U 0 `n o �@ _q It .. w >Y Z O v 0 W_ Q) N 0� W a� Q x 73 Z z a LU Z wIQ Q Z� to z O e N z .. w >Y Z Z w� zlz z z to z O X LUF_ Lu \ \ �a U LU tii � 0 � N aN > a- N W &pm Project ## : MENI&, 17170 Sheet GENERAL NOTES THE STRUCTURE HAS BEEN DESIGNED TO RESIST CODE PRESCRIBED VERTICAL AND LATERAL FORCES AFTER THE CONSTRUCTION OF ALL STRUCTURAL ELEMENTS HAS BEEN COMPLETED. STABILITY OF THE STRUCTURE IS THE SOLE RESPONSIBILITY OF THE GENERAL CONTRACTOR. THIS RESPONSIBILITY INCLUDES BUT IS NOT LIMITED TO J0551TE SAFETY: ERECTION MEANS, AND SEQUENCES: TEMPORARY SHORING, FORMWORK, AND BRACING: USE OF EQUIPMENT AND CONSTRUCTION PROCEDURES. STANDARDS ALL METHODS, MATERIALS, AND WORKMANSHIP SHALL CONFORM TO THE 2015 INTERNATIONAL BUILDING CODE (IBC) AND SEI/ASCE 1-10 'MINIMUM DESIGN LOADS FOR BUILDING AND OTHER STRUCTURES AS AMENDED BY LOCAL JURISDICTION PROJECT LOCATION: GPS LOCATION: 41.468200000 LAT., -122.223142000 LONGIT. SITE ADDRESS: 1820 NE 13TH 5T, RENTON, WA STRUCTURAL DESIGN CRITERIA (CH. 1(o) LATERAL FORCES: I. WIND (IBC 1609 e ASCE 6.0)- II. SEISMIC l IBC 1613 8 ASCE 11.0-13.0 ): 110 MPH WIND SPEED (ult) SEISMIC DESIGN CATEGORY - D2 85 MPH WIND SPEED (asd) OCCUPANCY RISK - II EXPOSURE - B 2% PE IN 50 YR ( 2006 LAT-LON) U56;5 -CD: IMPORTANCE FACTOR Iw = 1.0 0.2 SEC. (5s) 1.439 g WIND SPEED UP: KzT=1.00 1.0 SEC. (51) 0.531 g VERTICAL FORCES - GRAVITY ( IBC 1601 TABLE 1601.1 ) VERTICAL LOADS: DEAD LOAD LIVE LOAD ROOF ACTUAL 25 PSF SNOW (OR PER LOCAL JURISDICTION) FLOOR ACTUAL 40 PSF GARAGE I ACTUAL 50 PSF (or 30000 WHEEL LOAD) DECK ACTUAL 60 PSF SOILS AND FOUNDATION DESIGN CRITERIA (IBC CH. 18): SUBSURFACE INVESTIGATION SHALL BE REQUIRED PER 1803.2: FOUNDATION DESIGN SHALL BE BASED IN THE ABSENCE OF A SOILS REPORT, THE PRESUMPTIVE LOAD BEARING VALUES DETERMINED BY LOCAL JURISDICTION OR PER IBC TABLE 1806.2 SHALL BE USED: I. SOIL BEARING PRESSURE 1500 PSF 2. ACTIVE PRESSURE - RESTRAINED 45 PCF 3. ACTIVE PRESSURE - UNRESTRAINED 35 PGF 4. PASSIVE RESISTANCE 250 PCF 5, COEFFICIENT OF FRICTION 0.35 6. LOCAL FROST DEPTH 12 INCH ALL FOOTINGS SHALL BEAR ON FIRM UNDISTURBED EARTH OR COMPACTED 'STRUCTURAL BACKFILL'. AREAS OVER EXCAVATED SHALL BE BACKFILLED WITH LEAN CONCRETE (f'c = 2000 PSI) OR STRUCTURAL BACK FILL. CONCRETE (IBC CH. 19 $ ACI 318-11) CONCRETE: SHALL BE MADE WITH PORTLAND CEMENT ASTM C-150 TYPE II OR TYPE I AND SHALL BE READY -MIXED PER ASTM C-94, MAXIMUM SLUMP 5'. MINIMUM CEMENT CONTENT 51/2 SACKS PER YARD PROVIDE 5%-1% AIR -ENTRAINED CONCRETE FOR CONCRETE (f'c = 2000 PSI) EXPOSED TO WEATHER. MINIMUM SPECIFIED COMPRESSIVE STRENGTH (f'c At 28 DAYS) IBC TABLE 1904.2 USE OR LOCATION OF CONCRETE CONSTRUCTION: f'c (PSI) SPECIAL INSPECTION TESTING REQUIRED FOOTING PADS 4 FOUNDATIONS NOT EXPOSED TO WEATHER 2,500 NOT REQUIRED PORCHES, PATIOS, DRIVEWAYS, AND GARAGE SLAB 2,500 NOT REQUIRED FOUNDATION STEM WALLS AND INTERIOR SLABS ON GRADE 2,500 NOT REQUIRED CONTRACTOR SHALL HAVE AVAILABLE ON SITE A CONCRETE BATCH TICKET OR RECEIPT OF DELIVERY FOR MIX OF 3000 PSI OR GREATER FOR BUILDING INSPECTOR VERIFICATION IF REQUESTED. REINFORCING STEEL: REINFORCEMENT SHALL CONFORM TO ASTM A-615, 'DEFORMED AND PLAIN BILLET STEEL BARS FOR REINFORCING STEEL'. BARS SHALL BE GRADE 60 EXCEPT THAT NO. 3 AND 4 MAY BE GRADE 40. BARS SHALL BE DEFORMED. SPLICE SHALL BE 24 BAR DIAMETERS OR 18' MINIMUM. PROVIDE CORNER BARS FOR ALL HORIZONTAL BARS IN WALLS AND FOOTINGS AT INTERSECTIONS. MILL TICKET FOR REINFORCING BARS SHALL BE MADE AVAILABLE TO THE BUILDING INSPECTOR AND ENGINEER OF RECORD FOR VERIFICATION IF REQUESTED. WIRE FABRIC SHALL CONFORM TO ANSI/ASTM A-185, STEEL WELDED WIRE FABRIC PLAIN FOR CONCRETE PLACEMENT. CONCRETE ACCESSORIES: ANCHOR BOLTS, BARS AND RODS SHALL CONFORM TO ASTM A-301' 'LOW CARBON STEEL EXTERNALLY AND INTERNALLY THREADED FASTENERS'. CAST -IN-PLACE COLD -FORM STEEL CONNECTORS IN CONCRETE FOR LIGHT FRAME CONSTRUCTION SHALL BE MANUFACTURED BY SIMPSON STRONG -TIE AS SPECIFIED IN THE CURRENT SIMPSON STRONG -TIE IGC ES OR IAPMO E5 REPORT. ALTERNATE PRODUCTS SHALL BE SUBMITTED TO THE STRUCTURAL ENGINEER FOR REVIEW AND WRITTEN APPROVAL. REQUEST FOR SUBSTITUTION WILL ONLY BE APPROVED WITH CURRENT ICC E5 OR IAPMO E5 REPORT AND A LIST STATING THE PROPOSED ITEM SUBSTITUTION WITH EQUIVALENT OR GREATER LOAD CAPACITY. IN ADDITION, SUBSTITUTIONS WILL BE REQUIRED TO COMPLY WITH THE CURRENT ICC ACCEPTANCE CRITERIA, A0398 (CAST -IN-PLACE COLD -FORMED STEEL CONNECTORS IN CONCRETE FOR LIGHT FRAME CONSTRUCTION) PROPRIETARY CAST -IN-PLACE ANCHOR BOLTS SHALL BE '55' AND '551`5' ANCHOR BOLTS MANUFACTURED BY SIMPSON STRONG -TIE AS SPECIFIED ON THEIR LATEST CATALOG AND ICC E5R-2611. SUBSTITUTION PROPOSED BY THE CONTRACTOR SHALL BE SUBMITTED WITH A CURRENT ICC ES REPORT TO THE STRUCTURAL ENGINEER FOR REVIEW AND WRITTEN APPROVAL. IN ADDITION, SUBSTITUTIONS WILL BE REQUIRED TO COMPLY WITH THE CURRENT ICC ACCEPTANCE CRITERIA, AC399 (CAST -IN-PLACE PROPRIETARY BOLTS IN CONCRETE) EXPANSION ANCHORS (WEDGE ANCHORS) SHALL BE AS NOTED ON PLANS. INSTALLATION SHALL BE IN ACCORDANCE WITH MANUFACTURE'S RECOMMENDATIONS. WHEN NOTED ON CONSTRUCTION DOCUMENTS, INSTALLATION SHALL BE SPECIAL INSPECTED. NON -SHRINK GROUT: MASTER BUILDERS 'MA5TERFLOW 928 OR PRE -APPROVED EQUAL GROUT MAY BE PLACED FROM A 25 SECOND FLOW TO A STIFF PACKING CONSISTENCY. FILL OR PACK ENTIRE SPACE UNDER PLATES OR SHAPES. NO GROUTING SHALL BE DONE BELOW 40 DEGREES F. EPDXY GROUT: SIMPSON STRONG -TIE 'SET", COVERT OPERATIONS 'CIA' GEL, OR PRE -APPROVED EQUAL. TWO PART LOW SAG EPDXY. USE EQUIPMENT, WHICH SHALL ACCURATELY MIX AND DISPENSE THE COMPONENTS. HOLES SHALL BE DRILLED AT THE DIAMETER AS SPECIFIED BY THE MANUFACTURER BASED ON THE DOWEL BAR OR THREADED ROD DIAMETER HOLES SHALL BE DRY AND CLEANED WITH PRESSURIZED AIR JUST PRIOR TO INSTALLING GROUT. THE REBAR DOWEL OR THREADED ROD SHALL BE CLEAN AND INSTALLED SLOWLY, AND SHALL BE ROTATED AS IT IS PUSHED INTO THE HOLE. COLD WEATHER GROUTING SHALL BE DONE WITH PROPER GROUT FORMULA. EMBED (9) DIAMETERS MINIMUM UNLESS NOTED OTHERWISE IN PLANS AND DETAILS. GROUTING OPERATION SHALL BE INSPECTED BY AN AGENT AS RECOMMENDED BY THE OWNER. WOOD CONSTRUCTION (IBC CH. 23 $ NDS) GENERAL REQUIREMENTS: PROVIDE MINIMUM NAILING PER 2015 IBC TABLE 2304.9.1 OR MORE, AS OTHERWISE SHOWN. PRESSURE TREAT ALL WOOD IN CONTACT WITH CONCRETE OR MASONRY, PROVIDE CUT WASHERS WHERE BOLT HEADS, NUTS AND LAG SCREW HEADS BEAR ON WOOD, DO NOT NOTCH OR DRILL STRUCTURAL MEMBERS, EXCEPT AS ALLOWED BY IBC SECTIONS 2308.10.4.2 . OR AS APPROVED PRIOR TO INSTALLATION. WOOD SHEATHING: SHALL BE STRUCTURAL ' PLYWOOD OR ORIENTED STRAND BOARD. PLYWOOD SHALL BE GROUP I OR GROUP 2 SPECIES, C -D GRADE EXPOSURE I CONFORMING TO PS I-83, EACH PANEL SHALL BEAR THE GRADE TRADEMARK OF THE AMERICAN PLYWOOD ASSOCIATION. ORIENTED STRAND BOARD (OSB) SHALL BE APA RATED 5TRUCT.-1 FOR ROOF AND WALLS AND APA RATED STURDY -I -FLOOR FOR FLOORS. EACH PANEL SHALL BE CLASSIFIED AS EXPOSURE 1 AND SHALL BEAR THE GRADE TRADEMARK OF THE AMERICAN PLYWOOD ASSOCIATION (APA). FRAMING LUMBER STANDARDS: CONFORM TO WEST COAST LUMBER INSPECTION BUREAU (WCLIB), OR WESTERN WOOD PRODUCTS ASSOCIATION (WWPA). EACH PIECE SHALL BEAR THE 5CLI5 OR WWPA GRADE TRADE- MARK, SPECIES AND GRADE - BASE DESIGN VALUES l PSI) per NDS STRUCTURAL ELEMENT SPECIES/GRADE fbx fvx fc1 fc It E 1. 6x BEAMS AND HEADERS DF NO, 2 815 110 625 600 425 1300000 2, 4x BEAMS AND HEADERS DF NO. 2 900 180 625 1350 525 1600000 3. 2x JOIST HF NO, 2 850 150 405 1300 525 1300000 4. 6x POST DF NO. 1 1200 110 625 1000 825 1600000 5. 4X POST DF NO, 2 650 180 625 1400 500 1600000 6. 51/ax6 GLU-LAM POST 24F -V4, 24F -VS 2400 265 650 1650 1100 1100000 1, GLU-LAM BEAM 24F -V4, 24F -V6 2400 265 650 1650 1100 1800000 8. 31/2x OR 51/4x PSL BEAM PARALLAM PSL 2900 290 150 2900 - 2000000 9. 31/2x OR 51/4x LVL BEAM MICROLLAM LVL 2600 285 150 2510 - 1900000 10. 31/2x OR 51/4x LSL BEAM TIMBERSTRAND LSL 1100 400 680 1400 - 1300000 11. 2x WALL FRAMING HF NO. 2 850 150 405 1300 525 1300000 12. 2x WALL FRAMING , 15FT DF NO. 1 1000 180 625 1500 615 1100000 GLUE -LAMINATED MEMBERS: CONFORM TO ANSI/AITC AI90.1. MEMBERS SHALL BE COMBINATION 24F -V4 DOUGLAS FIR FOR SIMPLE SPANS, 24F -VS DOUGLAS FIR FOR CANTILEVERED SPANS WITH EXTERIOR GLUE. I -JOISTS: SHALL BE TRUS JOIST MACMILLAN, OR APPROVED EQUAL, AS INDICATED ON THE STRUCTURAL DRAWINGS. I -JOISTS SHALL BE MANUFACTURED IN ACCORDANCE WITH A CURRENT ICBG REPORT AND APPROVED SHOP AND INSTALLATION DRAWINGS. WOOD CONSTRUCTION CONNECTORS: SHALL BE MANUFACTURED BY SIMPSON STRONG -TIE AS SPECIFIED IN THEIR LATEST CATALOG. PROVIDE MAXIMUM SIZE AND QUANTITY OF NAILS, BOLTS, OR SCREWS SPECIFIED ON CONNECTOR HARDWARE. CONTRACTOR'S PROPOSED SUBSTITUTION OF OTHER MANUFACTURE'S CONNECTORS SHALL BE SUBMITTED TO THE STRUCTURAL ENGINEER FOR REVIEW AND WRITTEN APPROVAL PRIOR TO ORDERING. REQUESTS FOR SUBSTITUTION SHALL INCLUDE CURRENT ICC AND/OR IAPMO ES REPORTS AND A LIST STATING THE PROPOSED ITEM -FOR -ITEM SUBSTITUTION HAS AN EQUIVALENT OR GREATER LOAD CAPACITY. IN ADDITION, SUBSTITUTIONS SHALL COMPLY WITH CURRENT ICC ACCEPTANCE CRITERIA AC13 AND/OR IAPMO EVALUATION CRITERIA 002-2001 FOR JOIST HANGERS AND SIMILAR DEVICES AND ICC AC 155 FOR HOLDOWNS AND TENSION TIES. BOLTS IN WOOD CONNECTORS SHALL CONFORM TO ASTM A-301, GRADE A. STRUCTURAL WOOD SCREWS: WHERE SPECIFIED OR REQUIRED BY SPECIFIC HARDWARE, SCREWS SHALL BE 'SDS' STRONG -DRIVE SCREWS MANUFACTURED BY SIMPSON STRONG -TIE AS SPECIFIED IN THEIR LATEST CATALOG AND ICC ESR -2236. SUBSTITUTION PROPOSED BY THE CONTRACTOR SHALL BE SUBMITTED WITH A CURRENT ICC ES REPORT TO THE STRUCTURAL ENGINEER FOR REVIEW AND WRITTEN APPROVAL, IN ADDITION, SUBSTITUTIONS SHALL COMPLY WITH CURRENT ICC ACCEPTANCE CRITERIA AC233 (ALTERNATE DOWEL TYPE THREADED FASTENERS) REQUIREMENTS FOR FASTENERS IN TREATED MATERIAL: ALL HARDWARE AND FASTENERS IN PRESSURE TREATED MATERIAL SHALL BE SIMPSON GI85 HDG (HOT DIPPED GALVANIZED) OR 65T300 STAINLESS STEEL CONNECTORS OR EQUIVALENT. HOT DIPPED GALVANIZED FASTENERS SHALL BE USED WITH GI85 Z -MAX AND HDG CONNECTORS AND STAINLESS STEEL FASTENERS SHALL BE USED WITH 55T300 CONNECTORS. DO NOT USE STAINLESS STEEL FASTENERS WITH GI85 Z -MAX OR HDG CONNECTORS, ALL ANCHOR BOLTS, WASHERS, AND NUTS SHALL BE HOT DIPPED GALVANIZED. HOT DIPPED OR STAINLESS STEEL NAILS MUST BE USED WHEN FASTENING SHEATHING, STUDS, AND JOIST INTO TREATED MUD5ILL. HOT DIPPED GALVANIZED OR STAINLESS STEEL FA5TERE5 SHALL BE USED WHEN FASTENING DECKING TO TREATED MEMBERS. INSPECTION: TIBC CH. I SECT. 110 ) CONSTRUCTION SHALL BE SUBJECT TO INSPECTION BY THE BUILDING OFFICIAL AND SUCH CONSTRUCTION OR WORK SHALL REMAIN ACCESSIBLE AND EXPOSED FOR CONTINUING INSPECTION UNTIL APPROVED. THE OWNER OR CONTRACTOR SHALL NOTIFY THE BUILDING OFFICIAL TO MAKE THE INSPECTIONS SET FORTH IN SECTIONS 110.3.1 THROUGH 110.3.10. INSPECTION REQUESTS SHALL BE THE RESPONSIBILITY OF THE BUILDING PERMIT HOLDER. WORK SHALL NOT PROCEED BEYOND THE POINT INDICATED IN EACH SUCCESSIVE INSPECTION WITHOUT OBTAINING THE APPROVAL OF THE BUILDING OFFICIAL. THE BUILDING OFFICIAL SHALL INDICATE ANY OF CONSTRUCTION THAT IS SATISFACTORY AS COMPLETED, OR NOTIFY THE CONTRACTOR ANY PORTIONS THAT ARE NOT IN COMPLIANCE TO THIS CODE. ANY PORTIONS THAT DO NOT COMPLY SHALL BE CORRECTED BY THE CONTRACTOR AND SUCH PORTION(S) SHALL NOT BE COVERED OR CONCEALED UNTIL AUTHORIZED OR SIGNED OFF BY THE BUILDING OFFICIAL. ABBREVIATIONS, STRUCTURAL (THIS LIST APPLIES ONLY TO STRUCTURAL DRAWINGS) a co 6 AT EL ELEVATION MAX MAXIMUM 0 DIAMETER EN EDGE NAILING MIN MINIMUM * POUND/NUMBER EQ EQUAL NTS NOT TO SCALE *- PLUS OR MINUS ES EACH SIDE OC ON CENTER / PER EW EACH WAY OSB ORIENTED STRAND BOARD >a SQUARE FT FOOT OR FEET PL PROPERTY LINE AB ANCHOR BOLT FDN FOUNDATION PSF POUND PER SQUARE FOOT ALT. ALTERNATE FL FLUSH PSI POUND PER SQUARE INCH BLDG. BUILDING F.J. FLOOR JOIST PW PLYWOOD BLKG BLOCKING FOC FACE OF CONCRETE SHTG SHEATHING BM BEAM FOM FACE OF MASONRY STRUCT STRUCTURAL BN BOUNDARY NAILING FOS FACE OF STUD SIM. SIMILAR BOF BOTTOM OF FOOTING FOW FACE OF WALL SQ SQUARE BOT BOTTOM FIG FOOTING STD STANDARD BRG BEARING GA GAUGE SW SHEAR WALL C CHANNEL GALV GALVANIZED S.V. SCREEN VENT CBR CAMBER GL GLU-LAM (BEAM) TeG TOUNGUE AND GROOVE CANT CANTILEVER GT GIRDER TRUSS TOC TOP OF CONCRETE CJ CEILING JOIST HF HEM -FIR TOF TOP OF FOOTING C.J. CONSTRUCTION JOINT HGR HANGER TOS TOP OF STEEL C.L. CENTERLINE HDR HEADER TPL TRIPLE CONT CONTINUOUS HI HEIGHT TYP. TYPICAL DBL DOUBLE HOR HORIZONTAL UNO UNLESS NOTED OTHERWISE DET DETAIL IN. INCH VERT VERTICAL DIA. DIAMETER JST. JOIST W WIDE FLANGE STEEL BEAM DF DOUGLAS FIR L ANGLE W/ WITH DO DITTO, THE SAME LVL LAMINATED VENEER W/O WITHOUT EA EACH LUMBER EF EACH FACE NOTE: AREAS NOT HAI MINIMUM SHEAR PLATE NAILING SPACING. SEE ' SCHEDULE NOTE (THIS SHEET) SOLE PLA SCHEDULE FLOOF PLAN BLOCKING REQUIRE[ ALL HORIZONTAL UN; PW EDGES - SIZE PE DOUBLE TOP PLATE - MIN. LAP SPLICE SHALL BE 1'-0' - NAIL W/ 10cl 9 4' O.G. TRUSSES OR RAFTERS ABUTTING VERTICAL PW SPECIAL SHEAR WALL PANELS 3 EDGE FRAMING - SIZE SEE SCHEDULE FOR NAILING ROOF 5HTG. v PER SCHEDULE AND HOEDOWN TYPES PL ELEV. a co 0 CQ O rrnn VJ Z 0� E3 W HEADER PER to 4 4 z O xn O N Zul pa J W z PLAN L 0 Z Q O N m 0� +N+ IIS W N Q N 4-0 E r (DLu CHED REQUIRES p a 0 s NAILING OR SOLE Apm Project 4A : =Mw,&, OR ANCHOR BOLI x x SHEAR WALL S' 1 THRU 9 PW SHEATHING -SEE x' SCHEDULE FOR NAILING •E PER MS i FIN. FLR. PL ELEV. BEAM PER - - -- - ---- ' BLOCKING - L5TA24 J ABUTTING VERTICAL PWx x EDGE FRAMING - SIZEI SIMPSON MSTC66153 PER SCHEDULE ' PRE-BENT STRAP > AT x iUPPORTED ' R SCHEDULE ' 61 I ' SOLE FIN, FLR PL ; % B.O. PW 1 MAIN FLOOR JOISTS PER PLAN - (NOT READ. AT SLAB ON GRADE S2 CONDITION) 5/a' 0 A.B.'S - EMBED 1" MIN. -SPACE PER SHEAR WALL SCHEDULE BLOCKING �y i TREATED SILL PL I I WI WI STRAP HOLDOWN A E3 AT FOUNDATION 52 52 NOTE: THIS ELEVATION DOES NOT REPRESENT A SPECIFIC SHEAR WALL TYPE OR LOCATION. REFER TO THIS DETAIL FOR VARYING SHEAR WALL CONDITIONS, I.E. SHEAR WALL CONNECTION FROM SECOND FLOOR TO MAIN FLOOR. SEE TO SHEAR WALL SCHEDULE FOR SPECIFIC NAILING, HOLDOWN TYPES, AND FRAMING SIZES. ELEVATION TWO 5TORY FRAMING OR 8HEAR WALL (HATCHED) GIRDER TRUSS PER PLAN 2x BLOCKING (TYP.) SIMPSON H1 (TYP.) BOUNDARY EDGE FRAMING PER SHEAR WALL SCHEDULE ADDITIONAL STUDS BELOW GIRDER TRUSS PER PLAN �- 3/4' FLOOR 5HTG, 1 MST STRAPS PER PLAN FLOOR JOISTS PER PLAN I BOUNDARY EDGE FRAMING PER SCHEDULE 3/4' FLOOR SHTG. JJ ADDITIONAL EDGE FRAMING AND HOLDOWN REQUIRED BELOW EDGE OF UPPER FLOOR SHEAR WALL - SEE PLAN IF READ. 1I1I11 a co 0 CQ O rrnn VJ Z 0� E3 W a o to 4 4 z O xn O N Zul pa J W z w L 0 Z Q O N m 0� +N+ IIS W N Q N 4-0 E r (DLu L p a 0 1I1I11 E co 0 CQ O CQ Z C12co w w IE - W a o to 4 4 z � xn O N 4w0 �a pa w 1I1I11 E c� � 0 U O V E rn W m n, -� 1I1I11 c� � O V O E IS) W m n, -� LuLu xn O N O �u 18817 Sheet S1 N O > LuLu z w � O BaaC) O z ui r (DLu s Apm Project 4A : =Mw,&, 18817 Sheet S1 3/4' T4G PW SHEATHING - 2X JOISTS s 16' O.C. O O U #4 a 1(o` O.C. EACH WAY - z #4 TOP U SOLE PLATE NAILING PER SHEAR WALL SCHEDULE EDGE NAILING - SEE GENERAL NOTES 2x RIM TREATED SILL PLATE W/ Na' e A.B. 4 1/4'x3'x3' GALV. WASHERS. SEE SHEAR WALL SCHEDULE 4' TIGHT LINE U 4' PERF. DRAIN I COVER W/ FILTER FABRIC �n 8' (2) #4 CONT. W/ CORNER BARS SE CT I ON 3/4' T4G PW SHEATHING- S NAIL W/ ad 'a 6' O.C. EDGES OLE PLATE NAILING PER SHEAR WALL SCHEDULE AND ad -a Im' O.G. FIELD SAWN JOISTS 6 16' O.G. (1) #4 TOP U Lu #4 e 1(o' O.C. - EACH WAY z SLAB ON GRADE - REINF. PER PLAN —� #4 16 " O.C. EACH WAY EDGE NAILING - SEE GENERAL NOTES 2X RIM BOARD GARAGE SLAB ON GRADE J FOR DETAILS AND CALLOUTS IN • W COMMON, SEE 8' 1'-4' SE CT I ON 1 = l—vi • a" FOOTING M TREATED SILL PLATE W/ A.B. 4 1/4'x3'x3' GALV. WASHERS. SEE SHEAR WALL SCHEDULE EDGE NAILING - SEE GENERAL NOTES #4 TOP Z 4' TIGHT LINE 4' PERF. DRAIN COVER W/ FILTER FABRIC (2) 04 CONT. W/ CORNER BARS 3/4' T4G PW SHEATHING - 2X JOISTS .0 16O.C. Lu O O #4 .9 16' O.C. EACH WAY= z #4 TOP 3/4' T4G PW SHEATHING - SAWN JOISTS 16 " O.C. Lu (1) #4 TOP — O U Lu #4 6 16' O.C. EACH WAY z PLACE ALT. BARS AS SHOWN. SOLE PLATE NAILING PER SHEAR WALE SCHEDULE EDGE NAILING - SEE GENERAL NOTES 2X RIM BOARD Ne" a A.B. 4 1/4"x3'x3" GALV. WASHERS. TREATED SILL PLATE W/ SEE SHEAR WALL SCHEDULE 4' TIGHT LINE 4' PERF. DRAIN • O COVER W/ FILTER FABRIC SA (2) #4 CONT. W/ CORNER BARS 1-4 2 SECTION I" = SOLE PLATE NAILING PER SHEAR WALL SCHEDULE EDGE NAILING - SEE GENERAL NOTES 2X RIM BOARD GARAGE SLAB ON GRADE FOR DETAILS AND CALLOUTS IN cO COMMON, SEE • J� all -4 1'-4" SECTION r 11-01 2X BEARING WALL PER PLAN 3/4' T4G PW SHEATHING - 2X JOISTS 16' O.C. SOLE PLATE NAILING PER SHEAR WALL SCHEDULE EDGE NAILING - SEE GENERAL NOTES 2X BLOCKING AT BEARING WALL ONLY 4XID 2X6 X 14' EACH SIDE W/ (5) 16d GALV. IN BEAM 4 (5) 16d GALV. IN POST TREATED 4X4 AT CONT. SPAN BM. 4X6 AT BM. SPLICE ANGLE EACH SIDE - 5IMP50N A33 W/ (4) Imd IN POST (2) #4 EA. WAY I (4) SIMPSON PDP -150 POWDER ACTUATED FASTENERS J IN CONCRETE USING 6IMP60N PTP -21 0 3/4' T4G PW SHEATHING - SAWN JOISTS 16' 0. C. 7 BLOCKING iu 0 O U TREATED SILL PLATE W/ Lu 5/e" m A.B. 4 1/4" GALV. WASH z SEE SHEAR WALL SCHEDUL 04 fit 16' O.C. EACH WAY 2,-m, D_� ECTION I = 1 -m SOLE PLATENAILING - SEE SHEAR WALL SCHEDULE - SI BOTTOM OF FOOTING BEYOND. EDGE NAILING - SEE SHEAR WALL SCHEDULE - Sl + SIMP50N LTP4 (2) PER BLOCKING %� PIPE PARALLEL (3) 16d INTO BLKG TO WALL. 2X6 BLKG. - ATTACH TO JST, WEB W/ 4-10d 7/16' OSB SOFFIT 4" TIGHT LINE NAIL W/ ad 6 6' O.C. EDGES 4 12' O.C. FIELD /\\//\\//\\/ • — 4' PERF. DRAIN F COVER R C W/ FILTER (2) #4 CONT. W/ CORNER BARS SECTION 1 = 1 -oil POST PER PLAN — 40 DIA. (20" MIN) 4' SLAB ON BAS ALL CORNER GRADE 40 BAR DIA. LAP • TYP 20' MIN. � 1 NOTES: 2 ADD'L. IF NOKI" IAL WALL REINF- IS NOT IN PROPER LOCATION. " MIN 2. CORNER BARS ARE SAME 2 2N MAX SIZE AND SPACING AS HORIZ REINF. (2) #4 lm' AND ABOVE. 3. WALL DETAILS SHOWN. FOOTING DETAILS SIM. • ' I' CER. 4. WALLS THICKER THAN a' TO HAVE DOUBLE MAT. OF RE INF. 4 5' AND TYPICAL REINFORCEMENT PLACING PLAN FOR CONCRETE WALLS SMALLER USE SINGLE MAT. 10 SECTION 1" = I' -m' CORNER, OR # DOOR OR WINDOW EDGE OF SHEARWAL SEE FLOOR PLANS (2) STUDS -s SHEAR WALL PANEL EDGE EDGES. NAIL STUDS TO ADJACENT NAIL SPACING STUD W/ Imd la 12" O.C. PANEL EDGE NAILING. F HOLDOWN REQ'D BOTH ALSO NAIL TO TOP ' EDGES OF SHEARWALL PLATES SAME AS EDGE F NAILING TO STUDS: OF SHEARWALL NAILING ; USE MAX. QUANTITY q F SPECIFIED PER STRAP ; SHEAR WALL SHEATHING. ` } NAIL TO INTERMEDIATE FRAMING -m 12"O.C. PANEL EDGE NAILING TO SILL PLATE II z° Fm 4 r w HOEDOWN Nall,, "J" BOLT PANEL EDGE W/ 1/4' x 3" x 3' WASHERS NAIL SPACING AT EACH ANCHOR BOLTS ITYP.) SHEAR WALL SHEATHING (2) STUDS SOLE PLATE NAILING FLOOR SHEATHING 2X SOLID BLK. BELOW HOLDOWN - RIM J015T TREATED SILL PLATE SE CT I ON CONTRACTOR NOTE: U f0 9 0 O BEAM ABOVE. PRIOR TO I' = 1'-m" www in m p POURING FOOTING EDGE OF SHEARWALL SIMPSON C55Q66-6D6 O CORNER, OR POST BASE PER PLAN --• FINISH GRADE SEE FLOOR PLANS � � O DOOR OR WINDOW � w � 0 o (2) STUDS MIN, SHEAR WALL a • on PANEL EDGE 7 � Q EDGES. NAIL STUDS TO 40- SHEAR WALL NAIL SPACING14) cn r 2 ADJACENT STUD W/ Imd 12' O.C. m� SHEATHING HOLDOWN REQ'D BOTH O PANEL EDGE NAILING. C L 0 ALSO NAIL TO TOP 0 18817 EDGES OF SHEARWALL PLATES SAME AS EDGE NAILING t0 STUDS: OF SHEARWALL NAILING (2) STUDS USE MAX. QUANTITY SPECIFIED PER STRAP �. TREATED SHEAR WALL SHEATHING. SILL PLATE NAIL TO INTERMEDIATE } FRAMING 6 12' O.G. }� F w T m HOLDOWN ...% . p Lu Nei, "J" BOLT _______________..D W/ I/4' x 3' x 3' WASHERS .. � � _ _ _ AT EACH ANCHOR BOLTS - _ - -=-✓ PANEL EDGE NAIL SPACING 3/4' T4G PW SHEATHING - 2X JOISTS .0 16O.C. Lu O O #4 .9 16' O.C. EACH WAY= z #4 TOP 3/4' T4G PW SHEATHING - SAWN JOISTS 16 " O.C. Lu (1) #4 TOP — O U Lu #4 6 16' O.C. EACH WAY z PLACE ALT. BARS AS SHOWN. SOLE PLATE NAILING PER SHEAR WALE SCHEDULE EDGE NAILING - SEE GENERAL NOTES 2X RIM BOARD Ne" a A.B. 4 1/4"x3'x3" GALV. WASHERS. TREATED SILL PLATE W/ SEE SHEAR WALL SCHEDULE 4' TIGHT LINE 4' PERF. DRAIN • O COVER W/ FILTER FABRIC SA (2) #4 CONT. W/ CORNER BARS 1-4 2 SECTION I" = SOLE PLATE NAILING PER SHEAR WALL SCHEDULE EDGE NAILING - SEE GENERAL NOTES 2X RIM BOARD GARAGE SLAB ON GRADE FOR DETAILS AND CALLOUTS IN cO COMMON, SEE • J� all -4 1'-4" SECTION r 11-01 2X BEARING WALL PER PLAN 3/4' T4G PW SHEATHING - 2X JOISTS 16' O.C. SOLE PLATE NAILING PER SHEAR WALL SCHEDULE EDGE NAILING - SEE GENERAL NOTES 2X BLOCKING AT BEARING WALL ONLY 4XID 2X6 X 14' EACH SIDE W/ (5) 16d GALV. IN BEAM 4 (5) 16d GALV. IN POST TREATED 4X4 AT CONT. SPAN BM. 4X6 AT BM. SPLICE ANGLE EACH SIDE - 5IMP50N A33 W/ (4) Imd IN POST (2) #4 EA. WAY I (4) SIMPSON PDP -150 POWDER ACTUATED FASTENERS J IN CONCRETE USING 6IMP60N PTP -21 0 3/4' T4G PW SHEATHING - SAWN JOISTS 16' 0. C. 7 BLOCKING iu 0 O U TREATED SILL PLATE W/ Lu 5/e" m A.B. 4 1/4" GALV. WASH z SEE SHEAR WALL SCHEDUL 04 fit 16' O.C. EACH WAY 2,-m, D_� ECTION I = 1 -m SOLE PLATENAILING - SEE SHEAR WALL SCHEDULE - SI BOTTOM OF FOOTING BEYOND. EDGE NAILING - SEE SHEAR WALL SCHEDULE - Sl + SIMP50N LTP4 (2) PER BLOCKING %� PIPE PARALLEL (3) 16d INTO BLKG TO WALL. 2X6 BLKG. - ATTACH TO JST, WEB W/ 4-10d 7/16' OSB SOFFIT 4" TIGHT LINE NAIL W/ ad 6 6' O.C. EDGES 4 12' O.C. FIELD /\\//\\//\\/ • — 4' PERF. DRAIN F COVER R C W/ FILTER (2) #4 CONT. W/ CORNER BARS SECTION 1 = 1 -oil POST PER PLAN — 40 DIA. (20" MIN) 4' SLAB ON BAS ALL CORNER GRADE 40 BAR DIA. LAP • TYP 20' MIN. � 1 NOTES: 2 ADD'L. IF NOKI" IAL WALL REINF- IS NOT IN PROPER LOCATION. " MIN 2. CORNER BARS ARE SAME 2 2N MAX SIZE AND SPACING AS HORIZ REINF. (2) #4 lm' AND ABOVE. 3. WALL DETAILS SHOWN. FOOTING DETAILS SIM. • ' I' CER. 4. WALLS THICKER THAN a' TO HAVE DOUBLE MAT. OF RE INF. 4 5' AND TYPICAL REINFORCEMENT PLACING PLAN FOR CONCRETE WALLS SMALLER USE SINGLE MAT. 10 SECTION 1" = I' -m' CORNER, OR # DOOR OR WINDOW EDGE OF SHEARWAL SEE FLOOR PLANS (2) STUDS -s SHEAR WALL PANEL EDGE EDGES. NAIL STUDS TO ADJACENT NAIL SPACING STUD W/ Imd la 12" O.C. PANEL EDGE NAILING. F HOLDOWN REQ'D BOTH ALSO NAIL TO TOP ' EDGES OF SHEARWALL PLATES SAME AS EDGE F NAILING TO STUDS: OF SHEARWALL NAILING ; USE MAX. QUANTITY q F SPECIFIED PER STRAP ; SHEAR WALL SHEATHING. ` } NAIL TO INTERMEDIATE FRAMING -m 12"O.C. PANEL EDGE NAILING TO SILL PLATE II z° Fm 4 r w HOEDOWN Nall,, "J" BOLT PANEL EDGE W/ 1/4' x 3" x 3' WASHERS NAIL SPACING AT EACH ANCHOR BOLTS ITYP.) SHEAR WALL SHEATHING (2) STUDS SOLE PLATE NAILING FLOOR SHEATHING 2X SOLID BLK. BELOW HOLDOWN - RIM J015T TREATED SILL PLATE 'L" EACH WAY SEE FTG. SCHEDULE SEE SCHEDULE �1 SECTION 1 = 1 1 -m 1'-m�l U 'o I� SECTION r I -m 1'-m' MIN PIPE SLEEVE NO PIPE THROUGH i FOOTINGS PERMITTED 0 I I I/2 6' CONCRETE ALL SIDES OF PIPE. NO EXCAVATION PERMITTED BELOW THIS LINE, STEP FOOTING AS REQUIRED. I. THIS DETAIL SHOWS PERMISSIBLE LOCATION OF PIPES OR EXCAVATION. 2. FOR PIPES GREATER THAN 3'-m" BELOW FOOTING, BACKFILL TRENCH WITH STRUCTURAL BACKFILL. TYPICAL DETAIL OF PIPE AT CONCRETE FOOTINGS arECTION = I -m 0 CONTRACTOR NOTE: U f0 OPTIONAL CONSTRUCTION: SHORE POST AND 0 O BEAM ABOVE. PRIOR TO r www in m p POURING FOOTING co o► SIMPSON C55Q66-6D6 O I POST BASE PER PLAN --• FINISH GRADE w � � O w � w � 0 o �w a • on V 7 � 'L" EACH WAY SEE FTG. SCHEDULE SEE SCHEDULE �1 SECTION 1 = 1 1 -m 1'-m�l U 'o I� SECTION r I -m 1'-m' MIN PIPE SLEEVE NO PIPE THROUGH i FOOTINGS PERMITTED 0 I I I/2 6' CONCRETE ALL SIDES OF PIPE. NO EXCAVATION PERMITTED BELOW THIS LINE, STEP FOOTING AS REQUIRED. I. THIS DETAIL SHOWS PERMISSIBLE LOCATION OF PIPES OR EXCAVATION. 2. FOR PIPES GREATER THAN 3'-m" BELOW FOOTING, BACKFILL TRENCH WITH STRUCTURAL BACKFILL. TYPICAL DETAIL OF PIPE AT CONCRETE FOOTINGS arECTION = I -m 0 U f0 � rn 0 O cv r www in m p co o► LuJ O I Z [7 w � � O w � w � o �w a tQ V L � Q O 40- ;To0 cn r 2 m I1 C m� XN O Mai C L 0 a 0 18817 0 U f0 � rn 0 O cv r www in m p co o► LuJ w 0 U � rn 0 V \ C o'rn > co o► LuJ � � p � w � O_ � ozw �w a V � ui ;To0 cn r 0,, m m� XN w w O fL U 0 > LuJ � � w � z w � ozw �a a ui cn r w w w 0(L cv Project # 18817 Sheet 2x6 STUDWALL SOLE PLATE NAILING PER SHEAR 3/4' T4G PW SHEATHING- WALL SCHEDULE 2X LSL RIM JOIST EDGE NAILING - SEE GENERAL NOTES TJI JOISTS EDGE NAILING AS SPECIFIED 16" O.C. J PER SHEAR WALL SCHEDULE Ed (21/2') BOX ONE EA, SIDE 2X4 FLAT HORIZ. AT ALL UNSUPPORT DLOCKING PANEL EDGES PANEL JOINT HEADER PER PLAN SEE SHEAR WALL SCHEDULE ON 2x6 STUDWALL SHEET FRAMING PLANS FOR SPECIFIC NAILING � SECTION CIMOC/1A1 III t A/`I I tol ICC 2x6 STUDU, ad 6 BEAM PLAN 6X6 POST SECTION 1' = 1'-m' CORNER POST CONNECTION 10 SECTION 1" = 1'-m' O.G. SIMPSON HW: W=55/8', D=12' TOP FLANGE HANGER OFFSET RIGHT PW 1 PER PLAN 'CQ( 6 END WALL BRACE: 13/4'X11'/S' LVL BLKG. G S' -m' O.G. ( 2 BAYS) NAIL FLOOR SHTG. TO BLKG. W/ ad -a 4' O.G. NOTE: BLOCKING MAY BE ELIMINATED IF PERPENDICULAR WALL OCCURS WHERE BLOCKING IS REQUIRED, 3/4" T4G PW SHEATHING- - - A35 (TYP.) I I I I PW FILLER I I I I 2x6 STUDWALL SOLE PLATE NAILING PER SHEAR WALL SCHEDULE EDGE NAILING - SEE GENERAL NOTES 2X LSL CONT. RIM EDGE NAILING AS SPECIFIED PER SHEAR WALL SCHEDULE I I I I II II FLOOR JOISTS I I I I PANEL JOINT I I I I 2X4 FLAT HORIZ. BLOCKING AT PERPENDICULAR WALL / ALL UNSUPPORTED PANEL EDGES I/\ I HEADER PER PLAN SEE SHEAR WALL SCHEDULE ON SHEET FRAMING PLANS FOR SPECIFIC NAILING -SECTION 2x6 STUDWALL 2 = ad 6 6' O.C. ROOF SHEATHING RAFTERS OR ---2x SOLID BLOCKING OR TRUSS RIDGE BEAM AS REQUIRED T�Tf ICAL SIF IDETAIL ROOF ad 6' O.G. SHEATHING ROOF SHEATHING± EXTEND TO COVER FRAMING BELOW OVERFRAMING. RAFTERS OR TRUSS AFTERS OR TRUSS 2x CONTINUOUS ONNECT CONTINUOUS 2X VL Lo THRU ROOF SHEATHING TO / RAFTER BELOW 1' , 11-v WITH (2) 16d NAILS 2x6 STUDWALL 3/4' T4G PW SHEATHING - HANGER PER TJI MFR. TJI JOISTS 16' O.C- HEADER PER PLAN I II MFRD. MONO -TRUSSES _�� II 2x6 STUDWALL BEYOND I I I 2x6 STUDWALL I II �� SECTION I' = 11.011 SOLE PLATE NAILING PER SHEAR WALL SCHEDULE MFRD. TRUSSES SIMP50N HI EACH TRUSS L HEADER PER PLAN 2x6 STUDWALL 2x6 STU ad 9 6' O.G. EDGE NAILING - SEE GENERAL NOTES HANGER PER � __,,,,,, •.__ � SIMPSON HI EACH TRUSS ad -S 6 " O.C. 2x BLOCKING ad 6' O.G. OSB SHTG 3 SECTION r I' -o. SHEATHING PER PLAN- NAIL W/ ad -a 6" O.C. EDGES 8 ad -@ 12' O.C. INTERMEDIATE FRAMING MEMBERS 5IMP50N RBC - SPACED AT 6'-m' O.G. NOTE: DO NOT ATTACH TO BIRDS MOUTH BLOCKING � ad 1@ 6 " O.C. PROVIDE 2x SOLID BLOCKING AT 'RBC' LOCATIONS ONLY. EDGE NAILING - SEE GENERAL NOTES PW - SEE SHEAR WALL SCHEDULE ON SHEET Sl FOR SPECIFIC NAILING PANEL EDGE N. ALSO NAIL TO PLATES SAME OF SHEARWALL MST STRAP SECTION I = I' -o. 4EAK WALL 4EATHING STUDS SLE PLATE AILING .00R 4EATHING K SOLID BLK ,ELOW HOLDOWN RIM JOIST STUDS 6�EAR UUALL DETAIL UJ/ 5IMF50N MESE 5T AF I40LD000N (FES FLAN) SECTION CORNER, O EDGE OF SHEARWALL 1 DOOR, OR WINDOW SEE PLANS DOUBLE STUD SHEAR WALL EDGES PANEL NAIL 5f MSTG6653 REQ'D BC EDGES OF SHEARWAL SHEATHIN( ,NEL EDGE ILING HEADER BELOW WALL 1/2' PW W/ WALL SHTG. W/ IDETA L = 1—I6TC; AT 5EA OLE PLATE AILING - SEE CHEDULE _OOR HEATHING :ADER :LOW WALL U N 'o a C\ �z �r o► ('pom- IL f0 VJ DQ) P cv 7 12 W p. V r a o ra I I 1 W °0 4 J 0 4¢ o Q' fL U w m E3 w w Q z w U W oz0 z (D r W V 0 L ,gvm Project # : ENE%&, 0 z Q N m m +N+ f� 3 N LL Q 41 C L 0 a 0 C\ �z �r o► ('pom- 0 f0 U DQ) P cv 12 W p. V r a o ra I I 1 W 4114 4 0 4¢ o Q' fL U w C\ �z �r o► ('pom- 0 U DQ) � rn V o_ �w C\ �z �r o► ('pom- DQ) o� o_ �w I I 1 W �e o N m m� X ,i O N o Q' fL U Lb Q O O O m � w w z w U oz0 (D r ,gvm Project # : ENE%&, Lb Q O O 1 52 I S2 Y52 i I (5) 5HTG, (3) EDGE NAILING LENGTH x GAGE) --------- --------------------- I I I I I I I 1 i O I I I I II = L ------J U `4 F3.0 I I I I Ca I I I 0 � I I N I � x I I II I I 1 111-4N I 1 I II I, -JI 2 52 I I I I I I I I I I I I I I I I I I 01 1 I I I I I I I I I I I I I i I I I I I I I I I I I I I 4XIm T®- I R% 52'-0' 12'-6' 1 S� S2 1 yb% p----------� yJ'"_'L------ - - - - - - - - I � I � I ---------�--- +------ -----------I- ___ � F o LL- I_J U I F3.0 O F3.0 `Q I 1 @ I 1 CRAWL 5FACE 0 j 4" CONCRETE SLAB ON IS" MIN. CLEARANCE xI I COMPACTED GRAVEL FILL 6 MIL (BLACK) VISA. VAPOR BARRIER cv 1 2 W/ MIN, 12" LAP 1 3 52 4X10 IS 4X10 -- -�®� R% R; 4XIm ; �� \ 4X10 II ` 4XIm � I 6'-8" 41-611 2'-8' 1'-4" I II II 1 18"X24' CRAWL U SPACE ACCESS.0 6 INSULATE 4 WEATHER vfj ._. .. II R t I F3.0 - I cXv F3.0 II 52 I 8 m i \ I r _ 4XIO 4 I0 i 4 F2.01 I I = I I r R R L ---------------- -----------L 1 F2.0 1 3,y------------------------� 1 i N- 0 I � I 1L-- ---------� I I - - - - - - - /----- I I I I I I I I I 1 I 1 I I I 1 �2\ I I 4'-10' I I I I I I � I I I I 0 1 I � 1 I I I 1 4" GONG. OVER (o MIL (BLACK) V.B. OVER 4" GRANULAR FILL I SLOPE 4" TO O.N. DOORS 1 I I I 1 I I I I I I I I I � I � I L ----- ------ Al 11 v/ I I 52 1'-41" 1 11 L ---------------------L--- r L R' U � I I = I I III v I I - I I �d I 1 I I I I M I I 1111 F V -4'1'-41'414N 4'-6N 1'-41' I III 3 I II III S2 1 ---------------JIJ ----- - I I I I I I - 1 1 8 I 1 � I I I 1 _ I 1 �ni�t I 1 � I 1 6' I dim I i I 1 I I 1 I I 1 I I � 52 II' -4' 1 1 ■ 5kE3ARUJjALL 5CHEIDULE (1)(2)(4) WALL TYPE (5) 5HTG, (3) EDGE NAILING LENGTH x GAGE) (6)A.B, SPACING SOLE PLATE NAILING (GA.) ABUTTING VERT. PW EDGES ABUTTING HORIZ. PW EDGES (9) SOLE PL MUD SILL BOUNDARY FRAMING (VERT.) HOEDOWN TYPES REMARKS / DETAILS SHEAR (PLF) UPLIFT FORCE ll) 1/16" OSB N ($ z"�X 0.131') %N A.B. 6 24" O.C. 2x6 2x6 2x6 2x6 2-2x6 5THDI4RJ S 218 plf 1.8 k DF Aad) 1/16" OSB 6 6' O.G. (2V" X 0.131') 5�s' A.B. 36' O.C. 16d 6 8" O.C. (3-Y2" X 0.135") 2x6 2x6 2x6 2x6 2-2x6 5THD14RJ B 52 214 plf 28 k FROM THE FOUNDATION FOR RAIN OR IRRIGATION WATER 3 1/16' OSBIII Sd 6 4' O.C. (2/ X0.131) %N A.B. 6 36' O.G. 16d 6 8' O.C. (3y'X0.135') 2x6 2x6 2x6 2x6 2-2x6 5THDI4RJ e' S2 291 plf 2.9 k 36" Aoi 1/1(O" OSB16d Sd 6" O.G. l2 y" X 0.131') %' AB, -8 48' O.C. 9 12" O.C. (3-' X 0.135') 2xy26 2x6 2x6 2x6 2-2x6 NONE < 223 plf 0.0 k BE SIMPSON "IMAX' (G185 HDG PER ASTM A653). NOTE: FOR ALL OTHER EXTERIOR WALLS NOT SPECIFIED IN SCHEDULE ABOVE, SEE NOTE 2. IN 'SHEAR WALL SCHEDULE NOTES' . -------- ---- 2 FOUNDATION /MAIN FLOOR FRAMING PLAN DO NOT SCALE DRAWINGS. VERIFY ALL DIMENSIONS WITH ARCHITECTURAL DRAWINGS, SMEAR WALL KHEPULE NCTE5 (i IAIN FLOOR): I. SHEAR WALLS NOTED IN SCHEDULE ARE WALLS WITH ADDITIONAL EDGE NAILING, ABUTTING HORIZONTAL AND VERTICAL EDGE FRAMING, AND ANCHOR BOLT SPACING. FIELD NAIL SIZE SHALL MATCH THE EDGE FRAMING SPECIFIED AND BE SPACED AT 12" O.C. SHEAR NAILING APPLIES TO ALL VERTICAL AND HORIZONTAL ABUTTING SHTG. EDGES, DOUBLE TOP PLATES, AND SOLE PLATES. 2. ALL EXTERIOR WALLS NOT SPECIFIED IN SHEAR WALL SCHEDULE, SHALL BE DESIGNATED AS MINIMUM SHEAR PANELS WITH EDGE NAIL SIZE MATCHING SPECIFIED NAILS IN SCHEDULE AND SPACED AT 6' O.G. FIELD NAIL SPACING SHALL BE 12' O.C. 3. SHEATHING SHALL BE 1/16' OSB UNLESS SPECIFIED 15/32" STRUCTURAL *1 IN SCHEDULE. 4. EXTERIOR SHEAR WALL FRAMING SHALL BE 2X6 HEM FIR 02 UNLESS NOTED 'DF' (DOUG FIR) IN SCHEDULE. FRAMING SHALL BE SPACED AT lb"O.C. 5. INTERIOR SHEAR WALL FRAMING SHALL BE 2X4 (OR 2X(o PER SCHEDULE) HEM FIR #2 SPACED AT 16' O.G. 6. EDGE FRAMING OR END OF SHEAR WALLS SHALL BE FRAMED WITH: (2) MINIMUM 2X6 12X(o WALLS), (2) 2X4 (2X4 WALLS), OR SOLID SAWN POSTS AS NOTED IN THE SCHEDULE. 1. BLOCK ALL UNSUPPORTED HORIZONTAL SHEATHING EDGES WITH 2X6 OR 3X6 AS NOTED IN SCHEDULE. ALL VERTICAL ABUTTING SHEATHING EDGES SHALL BE 2X6 FOR EXTERIOR WALLS OR 2X4 FOR INTERIOR WALLS OR AS NOTED IN SCHEDULE. 8. SOLE PLATE SHALL BE 2X6 FOR EXTERIOR WALLS . SOLE PLATE SHALL BE 2X4 OR 2X6 FOR INTERIOR WALLS. SOLE PLATE NAILING SHALL BE 16d SPACED 12' O.0 (MAX. OR LESS AS SPECIFIED IN SCHEDULE) S. MUD SILLS SHALL BE 2X6 HF #2 P.T. CONTINUOUS AROUND PERIMETER OF FOUNDATION WALL. 10. FOUNDATION ANCHOR SHALL BE %N DIA. X 10" A.B. FOR 2X6 MUDSILL OR %N DIA. X 12' A.B. FOR 3X6 MUD61LL6, IF NOT SPECIFIED BY THE SHEAR WALL SCHEDULE, ANCHOR BOLTS SHALL BE SPACED NO MORE THAN 48" O.G. ALL ANCHOR BOLTS SHALL BE EMBEDDED IN CONCRETE 1" MIN. PROVIDE (2) MINIMUM AB -S FOR EACH MUDSILL SECTION. 11. PROVIDE 3'X3'XI/4' GALV. WASHERS FOR EACH ANCHOR BOLT. THE CONTRACTOR MAY USE 3'X3'XY4' GALV. WASHERS WITH DIAGONAL SLOTTED HOLES IF STANDARD CUT WASHERS ARE USED AND PLACED ABOVE THE SLOTTED PLATE WASHERS. LEGEND INDICATES SPREAD FOOTING PER PLAN AND REINF. PER SCHDULE. +(0 r-- -� INDICATES 6X6, 4X4, OR (X) 2X B.U. POSTS I � ORIGINATING AT THIS LEVEL AND SUPPORTING POINT LOADS FROM ABOVE. L J F3.0 INDICATES SHEAR WALLS WITH HOLDOWNS OR FOUNDATION STRAPS PER PLAN. SEE S SHEAR WALL SCHEDULE AND ELEVATION. boa Tyo INDICATES BEAM MARK NUMBERS PER PLAN AND STRUCTURAL CALCULATIONS. '-� 23 4X10 ---- INDICATES 4X4 POST BELOW CONT. FLOOR R i FR BEAMS OR 4X6 POSTS AT FLOOR BEAM L_ __J SPLICE. (TYPJ INDICATES ROUND OR SQUARE SPREAD FOOTING PER PLAN AND SCHEDULE. INDICATES /4 T4G PLYWOOD - NAIL WITH ad e 6' O.C. EDGES AND ad a 10" O.C. AT INTERMEDIATE FRAMING MEMBERS FOOTING SCHEDULE (1500 P51= BRGJ f'c = 2500 psi FOUNDATION 4 MAIN FLOOR FRAMING NOTES: DIMENSION (INCHES) REINF. 1. ALL FLOOR BEAMS SHALL BE 4X10 DF #2 UNLESS NOTED OTHERWISE ON PLAN. NOTE O "L' W. LOCATE BEAMS UNDER BEARING WALL WHERE NOTED ON PLAN. LONGIT. TRANSV. 2. ALL FOOTINGS SHALL BEAR ON FIRM UNDISTURBED GLACIAL TILL OR STRUCTURAL (X le FILL. SEE GENERAL NOTES FOR ASSUMED ALLOWABLE SOIL LATERAL OR VERTICAL 0 BEARING PRESSURES, 24' 24' 3, THE BOTTOMS OF FOOTING EXCAVATIONS SHALL BE LEVEL, CLEAN, AND FREE OF (3) 04 5.5 K L_ F2.0j1 LOOSE MATERIAL OR WATER WHEN CONCRETE IS PLACED. OVER EXCAVATION SHALL � V BE FILLED CONCRETE THE SAME STRENGTH AS FOOTINGS. 4. FINISH GRADE AROUND THE PERIMETER OF THE STRUCTURE SHALL BE DRAINED AWAY �� iii FROM THE FOUNDATION FOR RAIN OR IRRIGATION WATER 0 II 5. THE CONTRACTOR SHALL FOLLOW THE AVAILABLE GEO-TECH. REPORT FOR THE (2) #4 S2 � RECOMMENDED SITE PREPARATIONS BEFORE CONSTRUCTING THE FOUNDATION. m .. 6. ALL WOOD IN CONTACT WITH CONCRETE SHALL BE PRESSURE TREATED WITH AN r------� I � I � 36" 36" APPROVED PRESERVATIVE. ANY FIELD GUTS, NOTCHES, AND DRILLED HOLES SHALL (3) #4 (3) 04 12.4 K BE RE -TREATED PER AWPAM4. e 1. ALL FASTENERS 4 HARDWARE IN PRESSURE TREATED OR FIRE TREATED WOOD SHALL I � BE SIMPSON "IMAX' (G185 HDG PER ASTM A653). 4J - (3) #4 (3) 04 U I � I F3.5 1 L______J 8. PROVIDE DOUBLE JOISTS OR BEAM (PER PLAN) BELOW SHEAR WALL PARALLEL TO N TO JOISTS. NAIL WALL SOLE PLATE TO JOISTS OR BEAM PER SHEAR WALL SCHEDULE L 48" 48" OR NOTE 8. OF SHEAR WALL SCHEDULE NOTES. a (3) 05 9. PROVIDE Na' DIA. GALV. ANCHOR BOLTS EMBED 1' MIN. IN CONCRETE. PROVIDE 114"X3"X3" GALVANIZED WASHERS AT EACH ANCHOR BOLT. 10. PROVIDE APPROPRIATE BLOCKOUT IN STEM WALLS OR FOOTINGS FOR PLUMBING 4 60' 14" ((o)05 ELECTRICAL STUB -OUTS PER ARCH. PLANS. COORDINATE WITH GENERAL 33.5 K F L F5.0] CONTRACTOR 11. PROVIDE CRAWL SPACE ACCESS PER IBC AND ARCHITECTURAL PLANS. COORDINATE LOCATION IN SITE WITH CONTRACTOR 12. PROVIDE CRAWL SPACE VENTILATION PER IBC AND FOUNDATION PLANS, DO NOT ;.n 0 LOCATE VENTS WITHIN 8" OF HOLDOWN STRAPS OR HOLDOWN BOLTS, MAINTAIN 3'-0" -� m CLEAR FROM EACH CORNER, 13, FOR TYPICAL PLACEMENT OF HORIZONTAL REINF. IN CONCRETE, SEE 14/62. 14. FOR TYPICAL DETAIL FOR INSTALLATION OF PIPES NEAR FOOTINGS, SEE 8/52, 15. CONTRACTOR SHALL HAVE AVAILABLE ON SITE A CONCRETE BATCH TICKET OR =� RECEIPT OF DELIVERY FOR MIX OF 3000 PSI OR GREATER FOR BUILDING N INSPECTOR VERIFICATION. CONCRETE SHALL BE AIR ENTRAINED. TOTAL AIR CONTENT (PERCENT BY VOLUME OF CONCRETE) SHALL NOT BE LESS THAN 1 PERCENT PER IRC TABLE 402.2. SEE GENERAL NOTES IN SHEET Sl FOR ADDITIONAL REQUIREMENTS. 16. PROVIDE SQUASH BLOCKING BELOW ALL SOLID SAWN OR BUILT-UP 2X POSTS ALONG L 2 EXTERIOR OR INTERIOR STEM WALLS PER ELEVATION SHEET 51. 0 52 FOUNDATION /MAIN FLOOR FRAMING PLAN DO NOT SCALE DRAWINGS. VERIFY ALL DIMENSIONS WITH ARCHITECTURAL DRAWINGS, SMEAR WALL KHEPULE NCTE5 (i IAIN FLOOR): I. SHEAR WALLS NOTED IN SCHEDULE ARE WALLS WITH ADDITIONAL EDGE NAILING, ABUTTING HORIZONTAL AND VERTICAL EDGE FRAMING, AND ANCHOR BOLT SPACING. FIELD NAIL SIZE SHALL MATCH THE EDGE FRAMING SPECIFIED AND BE SPACED AT 12" O.C. SHEAR NAILING APPLIES TO ALL VERTICAL AND HORIZONTAL ABUTTING SHTG. EDGES, DOUBLE TOP PLATES, AND SOLE PLATES. 2. ALL EXTERIOR WALLS NOT SPECIFIED IN SHEAR WALL SCHEDULE, SHALL BE DESIGNATED AS MINIMUM SHEAR PANELS WITH EDGE NAIL SIZE MATCHING SPECIFIED NAILS IN SCHEDULE AND SPACED AT 6' O.G. FIELD NAIL SPACING SHALL BE 12' O.C. 3. SHEATHING SHALL BE 1/16' OSB UNLESS SPECIFIED 15/32" STRUCTURAL *1 IN SCHEDULE. 4. EXTERIOR SHEAR WALL FRAMING SHALL BE 2X6 HEM FIR 02 UNLESS NOTED 'DF' (DOUG FIR) IN SCHEDULE. FRAMING SHALL BE SPACED AT lb"O.C. 5. INTERIOR SHEAR WALL FRAMING SHALL BE 2X4 (OR 2X(o PER SCHEDULE) HEM FIR #2 SPACED AT 16' O.G. 6. EDGE FRAMING OR END OF SHEAR WALLS SHALL BE FRAMED WITH: (2) MINIMUM 2X6 12X(o WALLS), (2) 2X4 (2X4 WALLS), OR SOLID SAWN POSTS AS NOTED IN THE SCHEDULE. 1. BLOCK ALL UNSUPPORTED HORIZONTAL SHEATHING EDGES WITH 2X6 OR 3X6 AS NOTED IN SCHEDULE. ALL VERTICAL ABUTTING SHEATHING EDGES SHALL BE 2X6 FOR EXTERIOR WALLS OR 2X4 FOR INTERIOR WALLS OR AS NOTED IN SCHEDULE. 8. SOLE PLATE SHALL BE 2X6 FOR EXTERIOR WALLS . SOLE PLATE SHALL BE 2X4 OR 2X6 FOR INTERIOR WALLS. SOLE PLATE NAILING SHALL BE 16d SPACED 12' O.0 (MAX. OR LESS AS SPECIFIED IN SCHEDULE) S. MUD SILLS SHALL BE 2X6 HF #2 P.T. CONTINUOUS AROUND PERIMETER OF FOUNDATION WALL. 10. FOUNDATION ANCHOR SHALL BE %N DIA. X 10" A.B. FOR 2X6 MUDSILL OR %N DIA. X 12' A.B. FOR 3X6 MUD61LL6, IF NOT SPECIFIED BY THE SHEAR WALL SCHEDULE, ANCHOR BOLTS SHALL BE SPACED NO MORE THAN 48" O.G. ALL ANCHOR BOLTS SHALL BE EMBEDDED IN CONCRETE 1" MIN. PROVIDE (2) MINIMUM AB -S FOR EACH MUDSILL SECTION. 11. PROVIDE 3'X3'XI/4' GALV. WASHERS FOR EACH ANCHOR BOLT. THE CONTRACTOR MAY USE 3'X3'XY4' GALV. WASHERS WITH DIAGONAL SLOTTED HOLES IF STANDARD CUT WASHERS ARE USED AND PLACED ABOVE THE SLOTTED PLATE WASHERS. LEGEND INDICATES SPREAD FOOTING PER PLAN AND REINF. PER SCHDULE. +(0 r-- -� INDICATES 6X6, 4X4, OR (X) 2X B.U. POSTS I � ORIGINATING AT THIS LEVEL AND SUPPORTING POINT LOADS FROM ABOVE. L J F3.0 INDICATES SHEAR WALLS WITH HOLDOWNS OR FOUNDATION STRAPS PER PLAN. SEE S SHEAR WALL SCHEDULE AND ELEVATION. boa Tyo INDICATES BEAM MARK NUMBERS PER PLAN AND STRUCTURAL CALCULATIONS. '-� 23 4X10 ---- INDICATES 4X4 POST BELOW CONT. FLOOR R i FR BEAMS OR 4X6 POSTS AT FLOOR BEAM L_ __J SPLICE. (TYPJ INDICATES ROUND OR SQUARE SPREAD FOOTING PER PLAN AND SCHEDULE. INDICATES /4 T4G PLYWOOD - NAIL WITH ad e 6' O.C. EDGES AND ad a 10" O.C. AT INTERMEDIATE FRAMING MEMBERS FOOTING SCHEDULE (1500 P51= BRGJ f'c = 2500 psi DIMENSION (INCHES) REINF. ALLOWABLE TYPE O "L' W. THK LONGIT. TRANSV. a o41 LOAD (KIPS) (X le 0 I i ER 1 24' 24' 10" (3) #4 (3) 04 5.5 K L_ F2.0j1 O W � V � oz ID �� iii �0 0 24" DIA. 10" (2) #4 (2) #4 4.3 K � XL[i ON m .. - O 6 (L U r------� I � I � 36" 36" 10" (3) #4 (3) 04 12.4 K F3.0 L ------ J e gom Project # : mmijhL I � 42' 42' 12' (3) #4 (3) 04 16.5 K I � I F3.5 1 L______J I � I � 48" 48" 12' (3) #5 (3) 05 21.6 K F4.0 L______ J r -------i I � I � 1 i 60' 60' 14" ((o)05 (6) #5 33.5 K F L F5.0] s 0 U r^ co 1711 V ` c� � Dom-► O W C\2 c", a o41 10E - (X le 0 E W s 0 U r^ � � DI V ` c� � Dom-► O } (X E � w O W � V � oz ID �� iii �0 m W m� m � XL[i ON m .. - O 6 (L U 18817 Sheet S4 O } (X � w z � 0aa oz u iii cn r W � - m Q) > 0 IL W e gom Project # : mmijhL 18817 Sheet S4 MONO -TRUSSES 9 24' O.G. C816 X 52'-0' CONT. STRAP NAIL TJI JOISTS AND LVL BEAM e �r BLOCK ALL PANEL EDGES THIS AREA. NAIL WITH Sd -a 4' O.G. EDGES AND 10' O.G. AT INTERMEDIATE FRAMING. 52'-O' CSI6 X 29'-0' CONT. STRAP NAIL TO BLOCKING OVER WALL, AND 2X6 FLAT BLOCKING BETWEEN JOISTS 2 2 53 4XIO �� �� �� � 4XIO 4 F7-------------- L -_-----_-----_--I IIL ----- 10 53 , O511/2 X12 GL 4 - - 1 ECCQ66 - - - - - - - T I I � Fill -LL CIL - - O III I - - - - 0�)I 1 m 0 Il ii' I O ter, I\ I �� I I I I LO LO IO i - - - - - - - - -i l - - - - - -4 D I �v ml XI 53 ■ 15 I I II IL_��-------L---- ---_�- - - u HUS181/10 - - - I h� - - .- - - N - ---- I- HUS41O - I LVL 13/4 XIli/8 FLUSH �I J I -_� - - - - _ - - - - - - = - ----- _-------_-- - PHUS410 40 II �---------- 1 I 161 - - �r-------�� - 1 13 I i - - - - ----------, � I I LVL 3'/2 X II1SI LUSH I L -___--_ II - u� lu - - - - -� EGGQ66 uL-------Ju �I III - �-------�u I I LI li 11iH III III - - - - - - - III 4XIO II ------------------ - - - - - - - - - i II \ F" 0 - i I I 4XIO ' I- - - I I I � \ I EPC66 T LVL 311/2 X 11lk8 FLUSH (BELOW SHEAR WALL) MONO -TRUSSES 6 24' O.C. ��'` 0 �=B Lu - - _ car 0 2 LVL 311/2 X Ill/B FLUSH axl,� T Ao Ll Ao I' I 4X10 IO --- cs 6� A5 FLOOR FRAMING NOTES: WALL TYPE I. ALL EXTERIOR HEADERS SHALL BE 6XIO DF*2 UNLESS NOTED OTHERWISE ON PLAN. (6) SOLE PL NAILING 2 ALL INTERIOR HEADERS SHALL BE 4XIO DF*2 UNLESS NOTED OTHERWISE. 0. 2. ALL EXTERIOR WALL STUDS SHALL BE 2X6 HEM -FIR *2 SPACED AT 16" O.C. UNLESS REMARKS / DETAILS N 0 NOTED OTHERWISE ON PLAN. ALL INTERIOR WALL STUDS SHALL BE 2X4 HEM FIR *2 4 IT W 0 SPACED AT 16' O.C. UNLESS NOTED OTHERWISE. E3 3. FOR TYPICAL WALL FRAMING OR SHEAR WALL FRAMING SEE ELEVATION ON SHEET SI. 2x6 4. PROVIDE SOLID BLOCKING BELOW BEARING WALL OR SHEAR WALL PERPENDICULAR S3 g3 L z TO JOISTS. NAIL SOLE WALL SOLE PLATE TO BLOCKING PER SHEAR WALL SCHEDULE BY MOUNTED 5IMP50N HANGER. 40- 'o 'o OR NOTE 8, OR SHEAR WALL SCHEDULE NOTES. Sd .0 6' O.C. (2-%" X 0.131') 5. PROVIDE DOUBLE JOISTS OR BEAM (PER PLAN) BELOW SHEAR WALL PARALLEL TO INDICATES WALL STRAPS PER SHEAR WALL W INDICATES 6X6, 4X4, OR (X) 2X B.U. POSTS N a TO JOISTS. NAIL WALL SOLE PLATE TO JOISTS OR BEAM PER SHEAR WALL SCHEDULE M5T31 OR M5TC6653 D+ ORIGINATING AT THIS LEVEL AND a N OR NOTE lm. OF SHEAR WALL SCHEDULE NOTES. l.O k 6. PROVIDE JOIST BRIDGING PER JOIST MFR'S RECOMMENDATIONS. Ao i. PROVIDE SOLID 2X OR LVL RIM JOIST AT EXTERIOR WALL PER DETAIL AND PLAN, 16d 9 6' O.G. (3-%" X 0.135') 2x6 NAIL WALL SOLE PLATE TO RIM WITH PER SHEAR WALL SCHEDULE OR NOTE 10, OF 2x6 2-2x6 SHEAR WALL SCHEDULE NOTES. 8. FOR JOIST CONNECTION TO FLUSH OR UPSET BEAM ON ONE OR TWO SIDES, SEE DETAIL U 1/SI N 0 w 0 > 0 9. FOR SOLID POST OR BUILT UP 2X POST BEARING ON EXTERIOR OR INTERIOR WALL, a 0 SEE DETAIL 3/51. ,&om Project # : =Mir&, IO. II. NAIL JOISTS TO BEARING WALL TOP PLATES OR TOP OF BEAM WITH (2) IDB TOE NAIL EACH SIDE. 12. PROVIDE WEB STIFFENERS AT 'I' JOIST BEARING PER MFR'S RECOMMENDATIONS, 13. NOTCHING IN 'I' JOISTS NOT PERMITTED WITHOUT MFR'S APPROVAL. WALL TYPE rn 14. ALL WOOD IN CONTACT WITH CONCRETE SHALL BE PRESSURE TREATED WITH AN (6) SOLE PL NAILING 2 APPROVED PRESERVATIVE. ANY FIELD CUTS, NOTCHES, OR DRILLED HOLES SHALL 0. E BE RE -TREATED WITH AWPAM4. REMARKS / DETAILS N 0 15. ALL FASTENERS E HARDWARE IN PRESSURE TREATED WOOD OR FIRE -RETARDANT 4 IT W 0 WOOD SHALL BE 'ZMAX'(GI85 HDG PER ASTM A653). E3 LEGEND CSI6 X 65'-10' CONT. STRAP NAIL TO BLOCKING OVER WALL, AND LVL BEAM UPPER FLOOR FRAMING PLAN Ill/B' TJI/110 -m 16' O.G. DO NOT SCALE DRAWINGS, VERIFI' ALL DIMENSIONS WM4 ARCNITECTIJRAL DRAWING6. 5HEARWALL. 5CHEPP LE (1)(2)(4) WALL TYPE (5) SHTG, (3) EDGE NAILING (LENGTH x GAGE) (6) SOLE PL NAILING ILE ABUTTING HORIZ. PW EDGES (SJ SOLE PL E HOLDOWN TYPES REMARKS / DETAILS N 0 I -� -ir W 0 N 16d6 8' O.G.MST31 (3-%" X 0.135') LEGEND 2x 6 2x6 2-2x6 OR MSTC66B3 S3 g3 L z 08 k BY MOUNTED 5IMP50N HANGER. 40- 'o 'o 7/16 Sd .0 6' O.C. (2-%" X 0.131') m III N � � INDICATES WALL STRAPS PER SHEAR WALL W INDICATES 6X6, 4X4, OR (X) 2X B.U. POSTS N a SCHEDULE AND PLAN. M5T31 OR M5TC6653 D+ ORIGINATING AT THIS LEVEL AND a N Ill plf l.O k SUPPORTING POINT LOADS FROM ABOVE. p Ao 7/16' OSB CSI6 X 65'-10' CONT. STRAP NAIL TO BLOCKING OVER WALL, AND LVL BEAM UPPER FLOOR FRAMING PLAN Ill/B' TJI/110 -m 16' O.G. DO NOT SCALE DRAWINGS, VERIFI' ALL DIMENSIONS WM4 ARCNITECTIJRAL DRAWING6. 5HEARWALL. 5CHEPP LE (1)(2)(4) WALL TYPE (5) SHTG, (3) EDGE NAILING (LENGTH x GAGE) (6) SOLE PL NAILING ABUTTING VERT. PW EDGES ABUTTING HORIZ. PW EDGES (SJ SOLE PL BOUNDARY FRAMING (VERT.) HOLDOWN TYPES REMARKS / DETAILS SHEAR (PLF) UPLIFT FORCE -ir 7/16' OSB 86 9 4' O.G. (2-%" X 0.131') 16d6 8' O.G.MST31 (3-%" X 0.135') 2x6 2x 6 2x6 2-2x6 OR MSTC66B3 S3 g3 205 plf 08 k BY MOUNTED 5IMP50N HANGER. (7) 7/16 Sd .0 6' O.C. (2-%" X 0.131') 16 d -a 8' O.C. (3-%" X 0.135') INDICATES WALL STRAPS PER SHEAR WALL SCHEDULE AND PLAN. M5T31 OR M5TC6653 C Ill plf l.O k S3 S3 Ao 7/16' OSB Sd a 6' O.G. (2-%" X 0.131') 16d 9 6' O.G. (3-%" X 0.135') 2x6 2x6 2x6 2-2x6 NONE< 223 pIf 0.0 k NOTE: FOR ALL OTHER EXTERIOR WALLS NOT SPECIFIED IN SCHEDULE ABOVE, SEE NOTE 2. IN 'SHEAR WALL SCHEDULE NOTES' . INDICATES SPECIAL BEAM MARK NUMBER 22 6X10 PER PLAN AND STRUCTURAL CALCULATIONS. SEE WALL ELEVATION ON ------------ -- SI FOR FRAMING REQUIREMENTS. INDICATES WALL BELOW INDICATES WALL AT THIS LEVEL. INDICATES %4' T4G PLYWOOD - NAIL WITH ad Q 6" O.C. EDGES AND ad o 10' O.C. AT INTERMEDIATE FRAMING MEMBERS 5HEAR WALL 5CHEPUL N®TE5 (UFFER FL®®R): I. SHEAR WALLS NOTED IN SCHEDULE ARE WALLS WITH ADDITIONAL EDGE NAILING, ABUTTING HORIZONTAL AND VERTICAL EDGE FRAMING, AND ANCHOR BOLT SPACING. FIELD NAIL SIZE SHALL MATCH THE EDGE FRAMING SPECIFIED AND BE SPACED AT 12' O.C. SHEAR NAILING APPLIES TO ALL VERTICAL AND HORIZONTAL ABUTTING SHTG. EDGES, DOUBLE TOP PLATES, AND SOLE PLATES. 2. ALL EXTERIOR WALLS NOT SPECIFIED IN SHEAR WALL SCHEDULE, SHALL BE DESIGNATED AS MINIMUM SHEAR PANELS WITH EDGE NAIL SIZE MATCHING SPECIFIED NAILS IN SCHEDULE AND SPACED AT 6' O.C. FIELD NAIL SPACING SHALL BE 12' O.C. 3, SHEATHING SHALL BE 7/16' OSB UNLESS SPECIFIED 15/32' STRUCTURAL *1 IN SCHEDULE. 4. EXTERIOR SHEAR WALL FRAMING SHALL BE 2X6 HEM FIR *2 UNLESS NOTED 'DF' (DOUG FIR) IN SCHEDULE. FRAMING SHALL BE SPACED AT 16' O.G. 5. INTERIOR SHEAR WALL FRAMING SHALL BE 2X4 (OR 2X(o PER SCHEDULE) HEM FIR *2 SPACED AT 16' O.C. 6. EDGE FRAMING OR END OF SHEAR WALLS SHALL BE FRAMED WITH: (2) MINIMUM 2X6 (2X(o WALLS), (2) 2X4 (2X4 WALLS), OR SOLID SAWN POSTS AS NOTED IN THE SCHEDULE. I. BLOCK ALL UNSUPPORTED HORIZONTAL SHEATHING EDGES WITH 2X6 OR 3X6 AS NOTED IN SCHEDULE. ALL VERTICAL ABUTTING SHEATHING EDGES SHALL BE 2X6 FOR EXTERIOR WALLS OR 2X4 FOR INTERIOR WALLS OR AS NOTED IN SCHEDULE. 8. SOLE PLATE SHALL BE 2X6 FOR EXTERIOR WALLS. SOLE PLATE SHALL BE 2X4 OR 2X6 FOR INTERIOR WALLS. SOLE PLATE NAILING SHALL BE 1(od SPACED 12' O.0 (MAX. OR LESS AS SPECIFIED IN SCHEDULE) INDICATES 6X6, 4X4, OR (X) 2X B.U. POSTS 45;M-PERPLAN ORIGINATING AT LOWER LEVEL AND SUPPORTING POINT LOADS FROM THIS uj LEVEL AND ABOVE. O INDICATES SPECIAL POST/BEAM CAP PER C\2 PLAN OR GENERAL NOTES. FLUSH BEAM INDICATES TOP OF BEAM AND JOIST FLUSH. -ir -ir -1r -r �e x Jn ,O W. O (L U INDICATES MANUFACTURED "I' JOISTS OR SAWN JOIST SUPPORTED FACE m BY MOUNTED 5IMP50N HANGER. �s INDICATES SHEAR WALLS THIS LEVEL. SEE �.�'� �'`� 5 �,3j SHEAR WALL SCHEDULE AND ELEVATION. INDICATES WALL STRAPS PER SHEAR WALL SCHEDULE AND PLAN. INDICATES SPECIAL BEAM MARK NUMBER 22 6X10 PER PLAN AND STRUCTURAL CALCULATIONS. SEE WALL ELEVATION ON ------------ -- SI FOR FRAMING REQUIREMENTS. INDICATES WALL BELOW INDICATES WALL AT THIS LEVEL. INDICATES %4' T4G PLYWOOD - NAIL WITH ad Q 6" O.C. EDGES AND ad o 10' O.C. AT INTERMEDIATE FRAMING MEMBERS 5HEAR WALL 5CHEPUL N®TE5 (UFFER FL®®R): I. SHEAR WALLS NOTED IN SCHEDULE ARE WALLS WITH ADDITIONAL EDGE NAILING, ABUTTING HORIZONTAL AND VERTICAL EDGE FRAMING, AND ANCHOR BOLT SPACING. FIELD NAIL SIZE SHALL MATCH THE EDGE FRAMING SPECIFIED AND BE SPACED AT 12' O.C. SHEAR NAILING APPLIES TO ALL VERTICAL AND HORIZONTAL ABUTTING SHTG. EDGES, DOUBLE TOP PLATES, AND SOLE PLATES. 2. ALL EXTERIOR WALLS NOT SPECIFIED IN SHEAR WALL SCHEDULE, SHALL BE DESIGNATED AS MINIMUM SHEAR PANELS WITH EDGE NAIL SIZE MATCHING SPECIFIED NAILS IN SCHEDULE AND SPACED AT 6' O.C. FIELD NAIL SPACING SHALL BE 12' O.C. 3, SHEATHING SHALL BE 7/16' OSB UNLESS SPECIFIED 15/32' STRUCTURAL *1 IN SCHEDULE. 4. EXTERIOR SHEAR WALL FRAMING SHALL BE 2X6 HEM FIR *2 UNLESS NOTED 'DF' (DOUG FIR) IN SCHEDULE. FRAMING SHALL BE SPACED AT 16' O.G. 5. INTERIOR SHEAR WALL FRAMING SHALL BE 2X4 (OR 2X(o PER SCHEDULE) HEM FIR *2 SPACED AT 16' O.C. 6. EDGE FRAMING OR END OF SHEAR WALLS SHALL BE FRAMED WITH: (2) MINIMUM 2X6 (2X(o WALLS), (2) 2X4 (2X4 WALLS), OR SOLID SAWN POSTS AS NOTED IN THE SCHEDULE. I. BLOCK ALL UNSUPPORTED HORIZONTAL SHEATHING EDGES WITH 2X6 OR 3X6 AS NOTED IN SCHEDULE. ALL VERTICAL ABUTTING SHEATHING EDGES SHALL BE 2X6 FOR EXTERIOR WALLS OR 2X4 FOR INTERIOR WALLS OR AS NOTED IN SCHEDULE. 8. SOLE PLATE SHALL BE 2X6 FOR EXTERIOR WALLS. SOLE PLATE SHALL BE 2X4 OR 2X6 FOR INTERIOR WALLS. SOLE PLATE NAILING SHALL BE 1(od SPACED 12' O.0 (MAX. OR LESS AS SPECIFIED IN SCHEDULE) \ c� 0-)rn 0 uj U O www W C\2 1 E+ Q Lo z , V a o �o �e x Jn ,O W. O (L U w \ c� 0-)rn 0 uj U O 1 � rn V O_ �w � \ c� 0-)rn uj O 1 L u V O_ �w � �e x Jn ,O W. O (L U 18817 - Sheet - S5 co O m F- w Lu z z LLI �aa �z u di ,$)r W w 0 > 0 (L 0 ,&om Project # : =Mir&, 18817 - Sheet - S5 co 3 53 3 COORDINATION OF CONSTRUCTION, INCLUDMG VERIFICATION OF DII'ENSIONS t FIELD CONDITIONS, IS THE RESPONSIBILITY OF THE CONTRACTOR ANY DISCREPANCIES SHALL BE BROUGHT TO THE ATTENTION OF THE DESIGN TEAM PRIOR TO CONSTRUCTION. TOP OF BEAM AT PLATE 0 3 53 TOP OF BEAM AT PLATE - --- ---� 1 ----LVL -�Ii--�Ir- II II II II II II II II II II II II III III I I I I I I I I I I I III I I I I I II � II II II � II II 11i III 1 � I I I I I� I C==tom � I Ir-- 11 11 II 11 II II II II III III I I I I I I I I I I III I I I I I II II II II II II II i1 I --��-------------------- 1 --- ] C-----+--C=LU = I I III p I IL II I 1 LI III Ilp �� I F- IIS iil I I �Il� I �I I I I II I I II - I II II - JI II I 4d 1 j II III II O —44 I I II I OE TRUSS — Z _---- -- —J J L - III I� _ �--------- I I ADDL TRUSS�j I I 11 OVER SHEAR Ir -2 -1 I - tl WALL �j 1 III III I � 7 - II j III —1 7 - 9 1 4X8 I I 53 S3 � I---t1L--� ----- _ _ --- --- —1 ---- GIRDER GIRDER TRUSS I 1 I I I X II I I -4: 12 1 1 1 1 3 jL-------------------- -- — 117 II ------------------- --------- I I I 3 I I I I I I II I 1 I 11 I I -o`..� 1 1 11 ER TRU= I I I I I I } I I II I I I I II I �I I -I I I I I I -I II II II _ 6 - II - -- -- JL J JL JL_ JL -- I 1- 4-- X8 I 1 I S3 1 5'/2x12 GL 3 i3 3 I I BOT OF BEAM S3 I ON PLATE 5'-0' 10'-0' 5'-0' II Al II 1 II II GIRDER TRUSS I II I-4 GIRDER TRUSS— — =:4 �o I I Cru XI I X1 1 —I t I I+ I I I 3 I I =--T4Xs-�J = __- 0 ROOF FRAMING PLAN DO NOT SCALE DRAWINGS, VERIFY ALL DIMENSIONS WM4 ARCHITECTURAL DRAWINGS. 3 53 w ROOF FRAMING NOTES: I. ALL EXTERIOR HEADERS SHALL BE 6X8 DF*2 UNLESS NOTED OTHERWISE ON PLAN. ALL INTERIOR HEADERS SHALL BE 4X10 DF*2 UNLESS NOTED OTHERWISE ON PLAN. 2. SEE GENERAL NOTES AND TRUSS NOTES BELOW FOR TRUSS DESIGN SPEC IFIGATIONS. 3. ALL SAWN ROOF JOISTS SHALL BE HF*2 OR BETTER AND SPACED AT 24" O.G. UNLESS NOTED OTHERWISE. 4. PRE-MFRD. TJI JOISTS SHALL BE OF THE SIZE AND SERIES SPECIFIED ON THE PLAN. VERIFY MFRD, PLACEMENT PLAN WITH STRUCTURAL. NOTIFY THIS OFFICE OF ANY CONFLICTS IN LAYOUT BEFORE INSTALLATION. 5. PROVIDE ROOF VENTILATION PER CURRENT IRC OR IBC. SEE ARCHITECTURAL PLANS FOR SPECIFIC REQUIREMENTS. 6. PROVIDE ATTIC ACCESS PANEL PER CURRENT IRC, IBC, AND ARCHITECTURAL PLANS FOR SPECIFIC REQUIREMENTS. WOOD TRUSSES (I5C 2303.4) SHALL BE: 1. DESIGNED PER IBC 2303.4.1.1 TO CARRY LOADS LISTED IN THE DESIGN CRITERION AND ANY ADDITIONAL POINT LOADS, UNIFORM LOADS, OR DRAG STRUT FORCES NOTED ON FRAMING PLANS. 2. NON -ATTIC STORAGE TRUSSES SHALL BE DESIGNED WITH A LIVE LOAD OF 20 PSF LOCATED IN THE PLANE OF THE TRUSS. THE MAXIMUM STORAGE SPACE ABOVE THE BOTTOM CHORD SHALL BE LESS THAN 42' HIGH AND 24" WIDE. 3. TRUSS DESIGN DRAWINGS AND DOCUMENT SUBMITTAL (2303.4.1.1) SHALL INCLUDE STRESS ANALYSIS AND PICTORIAL DEPICTION OF EACH TRUSS TYPE FOR THE PROJECT AND INCLUDING A TRUSS PLACEMENT DIAGRAM (2303.42). TRUSS INSTALLATION DRAWINGS SHALL BEAR THE SEAL AND SIGNATURE OF A LICENSED ENGINEER IN THE STATE OF WASHINGTON. APPROVED TRUSS DOCUMENTS SHALL REMAIN ON THE JOB SITE FOR INSPECTION. 4. ALTERATIONS (2303.4.5): TRUSS MEMBERS SHALL NOT BE NOTCHED, DRILLED, SPLICED, OR OTHERWISE ALTERED IN ANY WAY WITHOUT WRITTEN APPROVAL OF THE TRUSS DESIGNER. ALTERATIONS RESULTING IN THE ADDITION OF LOADS TO ANY MEMBER (E.G. HVAC EQUIPMENT, PIPING, ETC.) SHALL NOT BE PERMITTED WITHOUT APPROVAL OF TRUSS DESIGNER. 5. TPI I SPECIFICATIONS: THE DESIGN, MANUFACTURE, FABRICATION, AND QUALITY ASSURANCE OF METAL -PLATE -CONNECTED WOOD TRUSSES SHALL BE IN ACCORDANCE WITH TPI 1. 6. TRUSSES SHALL BE BRACED TO MANUFACTURE'S SPECIFICATIONS. 1. UNLESS NOTED OTHERWISE ON PLANS, ALL TRUSSES SHALL HAVE 5IMP50N H-1 CLIPS AT EXTERIOR BEARING WALLS. AT GABLE END TRUSSES, PROVIDE SIMPSON A35 AT 24' O.C. 8. PROVIDE STG CLIPS AT ALL TRUSSES OVER NON-BEARING WALLS. 9. THE TRUSS LIVE LOADING SHALL BE PER IRC SECTION 301.5 AND TABLE 301.5 (FOOTNOTES b AND 2.) 10. TRUSS LOADING SHALL BE PER WASHINGTON ASSOCIATION OF BUILDING OFFICIALS WHITE PAPER 8-2010 OR BY IRC SECTION 301.2.3. SEE ALSO GENERAL NOTES 51. 11. THE TRUSS DESIGN SHALL BE PER IRC SECTIONS AND 502.11.1 AND 802.102 12. THE TRUSS TEMPORARY AND PERMANENT BRACING SHALL BE PER IRC SECTIONS p 502.112 AND 802.103 AS WELL AS THE TRUSS PLATE INSTITUTE'S BUILDING COMPONENT SAFETY INFORMATION. CONTRACTOR NOTE: REFER TO TRU55 MANUFACTURER DUJG. FOR TRU55 LAYOUT AND TYPE5. U5E TH15 DRAWING FOR LOCATION OF 5PECIAL SEAM 51ZE5, GIRDER TRU55 AND 5U I L T — UP P05T L OCAT I ON5. GEND NDICATES 6X6, 4X4, OR (X) 2X B.U. POSTS ORIGINATING AT LOWER LEVEL AND BM. PER PLAN SUPPORTING POINT LOADS FROM THIS 0 LEVEL AND ABOVE. cc 4 DILATES SPECIAL POST/BEAM CAP PER PLAN OR GENERAL NOTES. INDICATES SPECIAL BEAM MARK NUMBER O 6X10 PER PLAN AND STRUCTURAL CALCULATIONS. SEE WALL ELEVATION ON SI FOR FRAMING REQUIREMENTS. NDICATES WALL BELOW FLUSH BEAM DICATES TOP OF BEAM AND JOIST FLUSH. DICATES MANUFACTURED TRUSSES OR dw SAWN JOIST SUPPORTED BY FACE MOUNTED 5IMP50N HANGER. INDICATES %6' OSB SHEATHING - NAIL WITH Sd a 6" O.C. EDGES AND Sd a 12" O.C. AT INTERMEDIATE FRAMING MEMBERS (TYP.) U N 0 1 co cQ 3 i3 3 I I I S3 I cv �- II Al II 1 II II GIRDER TRUSS I II I-4 GIRDER TRUSS— — =:4 �o I I Cru XI I X1 1 —I t I I+ I I I 3 I I =--T4Xs-�J = __- 0 ROOF FRAMING PLAN DO NOT SCALE DRAWINGS, VERIFY ALL DIMENSIONS WM4 ARCHITECTURAL DRAWINGS. 3 53 w ROOF FRAMING NOTES: I. ALL EXTERIOR HEADERS SHALL BE 6X8 DF*2 UNLESS NOTED OTHERWISE ON PLAN. ALL INTERIOR HEADERS SHALL BE 4X10 DF*2 UNLESS NOTED OTHERWISE ON PLAN. 2. SEE GENERAL NOTES AND TRUSS NOTES BELOW FOR TRUSS DESIGN SPEC IFIGATIONS. 3. ALL SAWN ROOF JOISTS SHALL BE HF*2 OR BETTER AND SPACED AT 24" O.G. UNLESS NOTED OTHERWISE. 4. PRE-MFRD. TJI JOISTS SHALL BE OF THE SIZE AND SERIES SPECIFIED ON THE PLAN. VERIFY MFRD, PLACEMENT PLAN WITH STRUCTURAL. NOTIFY THIS OFFICE OF ANY CONFLICTS IN LAYOUT BEFORE INSTALLATION. 5. PROVIDE ROOF VENTILATION PER CURRENT IRC OR IBC. SEE ARCHITECTURAL PLANS FOR SPECIFIC REQUIREMENTS. 6. PROVIDE ATTIC ACCESS PANEL PER CURRENT IRC, IBC, AND ARCHITECTURAL PLANS FOR SPECIFIC REQUIREMENTS. WOOD TRUSSES (I5C 2303.4) SHALL BE: 1. DESIGNED PER IBC 2303.4.1.1 TO CARRY LOADS LISTED IN THE DESIGN CRITERION AND ANY ADDITIONAL POINT LOADS, UNIFORM LOADS, OR DRAG STRUT FORCES NOTED ON FRAMING PLANS. 2. NON -ATTIC STORAGE TRUSSES SHALL BE DESIGNED WITH A LIVE LOAD OF 20 PSF LOCATED IN THE PLANE OF THE TRUSS. THE MAXIMUM STORAGE SPACE ABOVE THE BOTTOM CHORD SHALL BE LESS THAN 42' HIGH AND 24" WIDE. 3. TRUSS DESIGN DRAWINGS AND DOCUMENT SUBMITTAL (2303.4.1.1) SHALL INCLUDE STRESS ANALYSIS AND PICTORIAL DEPICTION OF EACH TRUSS TYPE FOR THE PROJECT AND INCLUDING A TRUSS PLACEMENT DIAGRAM (2303.42). TRUSS INSTALLATION DRAWINGS SHALL BEAR THE SEAL AND SIGNATURE OF A LICENSED ENGINEER IN THE STATE OF WASHINGTON. APPROVED TRUSS DOCUMENTS SHALL REMAIN ON THE JOB SITE FOR INSPECTION. 4. ALTERATIONS (2303.4.5): TRUSS MEMBERS SHALL NOT BE NOTCHED, DRILLED, SPLICED, OR OTHERWISE ALTERED IN ANY WAY WITHOUT WRITTEN APPROVAL OF THE TRUSS DESIGNER. ALTERATIONS RESULTING IN THE ADDITION OF LOADS TO ANY MEMBER (E.G. HVAC EQUIPMENT, PIPING, ETC.) SHALL NOT BE PERMITTED WITHOUT APPROVAL OF TRUSS DESIGNER. 5. TPI I SPECIFICATIONS: THE DESIGN, MANUFACTURE, FABRICATION, AND QUALITY ASSURANCE OF METAL -PLATE -CONNECTED WOOD TRUSSES SHALL BE IN ACCORDANCE WITH TPI 1. 6. TRUSSES SHALL BE BRACED TO MANUFACTURE'S SPECIFICATIONS. 1. UNLESS NOTED OTHERWISE ON PLANS, ALL TRUSSES SHALL HAVE 5IMP50N H-1 CLIPS AT EXTERIOR BEARING WALLS. AT GABLE END TRUSSES, PROVIDE SIMPSON A35 AT 24' O.C. 8. PROVIDE STG CLIPS AT ALL TRUSSES OVER NON-BEARING WALLS. 9. THE TRUSS LIVE LOADING SHALL BE PER IRC SECTION 301.5 AND TABLE 301.5 (FOOTNOTES b AND 2.) 10. TRUSS LOADING SHALL BE PER WASHINGTON ASSOCIATION OF BUILDING OFFICIALS WHITE PAPER 8-2010 OR BY IRC SECTION 301.2.3. SEE ALSO GENERAL NOTES 51. 11. THE TRUSS DESIGN SHALL BE PER IRC SECTIONS AND 502.11.1 AND 802.102 12. THE TRUSS TEMPORARY AND PERMANENT BRACING SHALL BE PER IRC SECTIONS p 502.112 AND 802.103 AS WELL AS THE TRUSS PLATE INSTITUTE'S BUILDING COMPONENT SAFETY INFORMATION. CONTRACTOR NOTE: REFER TO TRU55 MANUFACTURER DUJG. FOR TRU55 LAYOUT AND TYPE5. U5E TH15 DRAWING FOR LOCATION OF 5PECIAL SEAM 51ZE5, GIRDER TRU55 AND 5U I L T — UP P05T L OCAT I ON5. GEND NDICATES 6X6, 4X4, OR (X) 2X B.U. POSTS ORIGINATING AT LOWER LEVEL AND BM. PER PLAN SUPPORTING POINT LOADS FROM THIS 0 LEVEL AND ABOVE. cc 4 DILATES SPECIAL POST/BEAM CAP PER PLAN OR GENERAL NOTES. INDICATES SPECIAL BEAM MARK NUMBER O 6X10 PER PLAN AND STRUCTURAL CALCULATIONS. SEE WALL ELEVATION ON SI FOR FRAMING REQUIREMENTS. NDICATES WALL BELOW FLUSH BEAM DICATES TOP OF BEAM AND JOIST FLUSH. DICATES MANUFACTURED TRUSSES OR dw SAWN JOIST SUPPORTED BY FACE MOUNTED 5IMP50N HANGER. INDICATES %6' OSB SHEATHING - NAIL WITH Sd a 6" O.C. EDGES AND Sd a 12" O.C. AT INTERMEDIATE FRAMING MEMBERS (TYP.) U N 0 O U IL co cQ V ca m 0 13 cv �- m �+ �� A L9 � Lu� C Z m W w w z O E L"W 0 N W oz `4 L ui 0 m Z a 0 N40- m 1 x ,n O N N E u L 0 Lu a U O U co cQ V ca m 0 w cv �- Awa a o CIOrn �o � Lu� C O U 18817 — sheet — S6 � �7 V ca m 0 N > Lu� C m w w z O E L"W 0 V oz `4 ui m W x ,n O N U°1 N u 18817 — sheet — S6 N 0 N > m w w z w 0 oz �aa ui N Q civ Lu e &I= Project # : =Nwg, 18817 — sheet — S6