Loading...
The URL can be used to link to this page
Your browser does not support the video tag.
Home
My WebLink
About
P_LandscapeArchitectPlans_170113_V1
■ MiIbrandt Architects 25 Central Way, Suite 210 Kirkland, Washington 98033 P:425.454.7130 F:425.658.1208 Web: www.milbrandtarch.com C 0 W Cl) E YY C U° W Q 5 i c s a or3 N e 4-0 FMZ °' Z o� 3 Q o N F — U t0 M Q Job No.: 1529 Sheet No.: L-100 0 a a 0 r C N o O N T- O T CO D Z O I m Q a N � II r C 0 W Cl) E YY C U° W Q 5 i c s a or3 N e 4-0 FMZ °' Z o� 3 Q o N F — U t0 M Q Job No.: 1529 Sheet No.: L-100 T 1-2 LINE CD N -7 4- 6' 6 \HT. OOD GATE 10 GATE, TYP 5 89009'29" W - - - - - - - - 62S 40' 2 -0;' HT. WOOD FENCE, TYP. 6-10 /PROPERTY LINE-, -- o \ 241.3 SF � 302.6 SF 241 3 SF 287.4 SF � SF 3 3 -6" HT. WOOD F -10 FENCE, TYP. 3 3 8" +18" +18• 3 6_110BUILDING -10 °� F21 E16 E16 F BUILDI G 3 S BUILDING 1 -102 BUILDING 2 II 0 0 0 - nl III x1141 /' n o� ° ° ° o 3181 SF 2630 SF 3'-6" HT. 2630 F 3 O HT. 3 6 HT. WOOD WOOD WOOD GATE, TYP S GATE, TYP F21 GATE, TYP F21 „$ El E20 +8 F21 � F21 E16 E20 E16 + 8�• F21 +,a.. El 6 E20 + s° F21 O \� 3'-6" HT. WOOD 3'-6'' SIT. WOOD(109 S-6" HT. WOOD FENCE TYP. 10 FENCE TYP. FENCE TYP. (109 ° ° TLL G22355FpM.4SF 2279.9 SF 223.5 SF 265.SF - 223.5 S °279.9 SF 223. SF 265.3 SF 279.95ES GREEN 0 0 ° o � ° ° ° � SPACE o � o ,, ° ° p PL/�ZA ° ALKWAY � °D PARK S S o� 1,513 SFO O 4,365 S ° 22. f - 0 2 2 9.9 SF 5.6 SF 223.5 SF 275.9 F 279.9 SF 2 5.6 SF 223.5 S �i 232. SF o - -LU moi 77- S-6" 3'-6" HT. WOOD � d 3'-6" HT. 3 r--- 3'-6" H\ WOOD WOOD GATE 3 FENCE, TYP. WOOD GATE -10 FENCE, TYP. -10 O TYP. 3 3 ° F2 -10 E16 E20 F21 F2 -102 Ell6 E20 8.. F - BUILDING 6 BUILDING 7 2630 SF - 2630 SF 4 F L-77 7 N w °N 03 \ I � I nnniw Tr rnnir \ I ` 6'-0" HT. WOOD FENCE, TYP. 2 � PROPERTY LINE -10 `Po \ SS �' N � l PA KING) J 1 FENCING PLAN 1 Ili\illIIIIIIIIi\ III=II NOTES: 1. END AND CORNER POSTS TO BE 6"x6". LINE POSTS TO BE 4"x4". ALL POSTS TO BE PRESSURE TREATED LUMBER. 2. POSTS AT 8' O.C. +/- (MAINTAIN UNIFORM SPACING BETWEEN POSTS). 3. ALL OTHER WOOD TO BE TIGHT KNOT CEDAR. 4. ATTACH RAILS TO POSTS WITH NON-VISIBLE GALVANIZED BRACKET. 5. ALL HARDWARE TO BE GALVANIZED STEEL 6. FINISHED SIDE OF FENCE TO FACE INTO SITE. 7. CONTRACTOR TO SUBMIT SHOP DRAWINGS FOR REVIEW PRIOR TO INSTALLATION. 6'-0" HT. WOOD FENCE 2"X8"X8" CAP AT r AND END POSTS -2"X4" CAP ____2"X6" TOP R » 1»x6 FENCE PL ALLOW 1/8" SP BETWEEN PLANk -POSTS AT 8' o.c MAINTAIN UNIFC PACING BETWEE POSTS) 2"X4" BOTTOM R 12" DIAMETER C, Scale: 11/2"=V-0" 3'-6" HT. WOOD 1 FENCE, TYP. 10 FENCE +8„ F21 L-A 03 III Lj11'4 3181 SF E20 \ - F- v ° BUILDING 5 F21 E16 3181 SF E16 F21 E20 302.6 SF 2 1.3 SF 281.4 SF �35 y 3 S-6" HT. WOOD -10 GATE, TYP. TREE PRESERVATION 2595 SF SCALE: 1 "=20'-0" mmm 0' 10' 20' 3 S-6" HT. WOOD ° -102 FENCE, TYP. 1.3 SF .3 SF ° PROPERTY LINE 20 6'-00% HT. WOOD FENCE, TYP. 6"X6"X2"IPE POST CAP SCREW 2"X2" VERT. 4"X4"IPE POSTS 3'-4" GATE LATCH POST AND RAIL TO 4"X4" 90° OPENINGHARDWARE CAP POST WITH #8x2" HINGES 2 TYP 2 TYP BEYOND 3/6" PAN HEAD SCREWS X (5)- N 1x2 IPE WOOD - -_ - -_-N - - - � �N � FENCING SCHEDULE I #8x2" 3/ " SS PAN -- - -N - -- -- HEAD SCREWS WITH -N - SYMBOL NAME NOTES SS FINISH WASHER 0 2"X2" IPE VERT. o RAIL 6'-0" HT. WOOD FENCE 1x6 IPE WOOD 3'-6" HT. WOOD FENCE II �IIII �':IIIIIIIIIII�I N � a_ III _II II III= N� a III�� .111111 III III III III 12>> DIAMETER CONCRETE FOOTING, AT LINE POSTS. NOTES: 1. CONTRACTOR TO SUBMIT SHOP DRAWINGS FOR REVIEW PRIOR TO INSTALLATION. 2. POSTS AT 4' O.C. +/- (MAINTAIN UNIFORM SPACING BETWEEN POSTS). T-6" HT. WOOD FENCE & GATE Scale: 11/2"=V-0" 0 U 71 F_ z m L0 Z I 0 0 m r z m Scale: 1 "=20'-0" 80' STATE OF WASHINGTON L ENSED A E TECT NICHOLAS PAU AGAN CERTIFICATE 11n. 753 FENCING PLAN & DETAILS MiIbrandt Architects 25 Central Way, Suite 210 Kirkland, Washington 98033 P:425.454.7130 F:425.658.1208 Web: www.milbrandtarch.com TI W � UO Ws Q > C i J .� m 0'E 3 N In e Q c Fm Z Rf Z o0� 3 Q 0 (n oC 0 0 U 0 M Q Job No.: 1529 Sheet No.: L-102 POINT OF CONNECTION APPROXIMATE LOCATION OF P.O.C. TO 2" STUB -OUT FROM IRRIGATION SERVICE LINE AS SHOWN ON CIVIL DRAWINGS. VERIFY AND ADJUST LOCATION PRIOR TO INSTALLATION IF REQUIRED TO AVOID CONFLICTS WITH ADJACENT UTILITIES. PROVIDE P.O.C. COMPONENTS AS SHOWN IN POINT OF CONNECTION DETAIL. NOTIFY OWNER IMMEDIATELY OF ANY DISCREPANCIES. VERIFY MIN. 80 PSI DESIGN FLOW AT P.O.C. PRIOR TO WORK. /-34;1Y4" /_1Y4" 1" - RUN i'!! PROPERTY LINE i ROTATOR 5.2 LAWN 4 SPR Y 1.5" SHR B 6.9 3/4' 3/4» LATERAL ,TUB -UP GPM SIZE PLANT TYPE 1 „ -� °) 00o 0 0 o 1Y2 N -P o • SPRAYB 16 SHRU 2" AINLINE I_ . ,�; - ISI • LATERAL STUB -UP FOR 2.7 1 SPRAY LAWN 3/4" DRIP CONNECTIONS, TYP. 1.5" SHRUB LA ERAL_ - ---- --- ----- 33.0 ST B -UP -___ _- =- --- - - 19.68 1" SHRUB DRIP 8 18 ]----- ° C NNEO TIONS, SHRUB DRIP 2„ 2» 2" SHRUB SPRAY 11 21.52 TYP. ' SHRUB SPRAY 12 4.2 1" SHRUB ' 13 38.13 ,i SLV SLVSLV 14 SLV SLV SHRUB SPRAY 3 " 3/4 3.6 1 SHRUB DRIP BUILDING 1 29.26 1.5" 0 SPRAY 17 12.11 1" SHRUB SPRAY 18 3181 SF 1" SHRUB SPRAY 19 6.2 1" SHRUB DRIP 20 12.11 1" SHRUB SPRAY F21 El 6 E 2 0 E16 +18 LV F21 1)/4" 22 ROTATOR 5.2 LAWN 4 SPR Y 1.5" SHR B 6.9 3/4' 3/4» LATERAL ,TUB -UP +ta I 2„ 2" ° SLV SLV SLV 1" 1Y4" , 3/4279.9 SF 223.5 265.4 I --- S 3/4" ==_____--- --____ _= S FI I 1 I 3/4' 3/4» I I I I c I I tB 2„ 1 » 2„ SLV SLV SLV I F21 E16 E20 E16 F21 11 BUILDING 8 wit f 3181 SF 2" o L 2" 2'$ 2" 2» SLV SLV SLV SLV SLV -_ i T3//.3/4" LATERAL STUB -UPS R 00 DRIP CONNECTIONS, T P. r 1 „ r 3/4„ �R PROPERTY LINE CONTROLLER LOCATE CONTROLLER IN PEDESTAL CABINET IN APPROXIMATE \ LOCATION SHOWN. VERIFY WITH ARCHITECT. PROVIDE \ SEPARATE 15 AMP CIRCUIT AND 120 VAC POWER TO CONTROLLER. PROVIDE 2" CONDUIT FROM CONTROLLER, AND INTO THE NEAREST PLANTING AREA AS SHOWN. EXTEND 24" INTO PLANTING BED, 18" BELOW GRADE. CAP AND FLAG. WIRELESS RAIN SENSOR \MOUNT ON PEDESTAL CABINET IN APPROXIMATE LOCATION SHOWN. VERIFY EXACT LOCATION WITH ARCHITECT AND CONFIRM WIRELESS SIGNAL PRIOR TO INSTALLATION. LOCATE ALL IRRIGATION MAINLINE, LATERALS, AND VALVES WITHIN PLANTING AREAS, UNLESS SLEEVING IS SHOWN, TYP. �1Y4" 5 8900912911 W 1Y4' 1" 1" 3/4" �X� II �w C' c II 4N 2" MAINLINE SLV LATERAL STUB -UP FOR SLVLATERAL STUB -UP FORDRIP CONNECTIONS, TYPDRIP CONNECTIONS, TYP. r4" 3/4_ I -- - - - -- - --- 3/4 ° L 2„ 2„ 2» 34 1Y4' 3/4'> 10 SPRAY Y4 SPRAY SLV SLV SLV /4 96 SHRUB SLV SLV SLV SHRUB ° o BUILDI G 3 ° 9.6 BUILDING 2 2630 SF 82630 SF 1Y4" ° ° 11 SPRAY 211 SPRAY 3„ HR D 18'0 SHRUB .,8 LV 3/4 D 1.5 E2T UB SLV .,8„ E16 E20 X18• F21 +8.. E16 E20 F21 9 2„ 2" -- ° ° 12 DRIP 2„ 2„ 3» 1 DRIP SLV SLV 1 SHRUB SLV SLV SLV 5.20 SHRUB 1°° 1Y4" 3/4„ 2'.5 65.3354„ 3/4» 1 " S 3/'I�223.5 65.6 SF 23 I I PROPERTY LINE SLV �,� 11L�I ' illll Ilii ►� Ip i 3/4 GPM SIZE PLANT TYPE 1 • �. © .. .,-. • ® .- I_ . ,�; - ISI • �..��� . I �• !Ill WARM-,\II +ta I 2„ 2" ° SLV SLV SLV 1" 1Y4" , 3/4279.9 SF 223.5 265.4 I --- S 3/4" ==_____--- --____ _= S FI I 1 I 3/4' 3/4» I I I I c I I tB 2„ 1 » 2„ SLV SLV SLV I F21 E16 E20 E16 F21 11 BUILDING 8 wit f 3181 SF 2" o L 2" 2'$ 2" 2» SLV SLV SLV SLV SLV -_ i T3//.3/4" LATERAL STUB -UPS R 00 DRIP CONNECTIONS, T P. r 1 „ r 3/4„ �R PROPERTY LINE CONTROLLER LOCATE CONTROLLER IN PEDESTAL CABINET IN APPROXIMATE \ LOCATION SHOWN. VERIFY WITH ARCHITECT. PROVIDE \ SEPARATE 15 AMP CIRCUIT AND 120 VAC POWER TO CONTROLLER. PROVIDE 2" CONDUIT FROM CONTROLLER, AND INTO THE NEAREST PLANTING AREA AS SHOWN. EXTEND 24" INTO PLANTING BED, 18" BELOW GRADE. CAP AND FLAG. WIRELESS RAIN SENSOR \MOUNT ON PEDESTAL CABINET IN APPROXIMATE LOCATION SHOWN. VERIFY EXACT LOCATION WITH ARCHITECT AND CONFIRM WIRELESS SIGNAL PRIOR TO INSTALLATION. LOCATE ALL IRRIGATION MAINLINE, LATERALS, AND VALVES WITHIN PLANTING AREAS, UNLESS SLEEVING IS SHOWN, TYP. �1Y4" 5 8900912911 W 1Y4' 1" 1" 3/4" �X� II �w C' c II 4N 2" MAINLINE SLV LATERAL STUB -UP FOR SLVLATERAL STUB -UP FORDRIP CONNECTIONS, TYPDRIP CONNECTIONS, TYP. r4" 3/4_ I -- - - - -- - --- 3/4 ° L 2„ 2„ 2» 34 1Y4' 3/4'> 10 SPRAY Y4 SPRAY SLV SLV SLV /4 96 SHRUB SLV SLV SLV SHRUB ° o BUILDI G 3 ° 9.6 BUILDING 2 2630 SF 82630 SF 1Y4" ° ° 11 SPRAY 211 SPRAY 3„ HR D 18'0 SHRUB .,8 LV 3/4 D 1.5 E2T UB SLV .,8„ E16 E20 X18• F21 +8.. E16 E20 F21 9 2„ 2" -- ° ° 12 DRIP 2„ 2„ 3» 1 DRIP SLV SLV 1 SHRUB SLV SLV SLV 5.20 SHRUB 1°° 1Y4" 3/4„ 2'.5 65.3354„ 3/4» 1 " S 3/'I�223.5 65.6 SF 23 I I PROPERTY LINE SLV �,� 11L�I ' illll Ilii ►� Ip i 3/4 SLV 1 SLV ° ° SLV FOR DRIP 4 ° CO NECTION, 2" TYP. F21 E16 E20 F21 1 F21 E16 E20 F21 SLV �, 8" +, 8" I +18" +18„ � BUILDING 6 BUILDING 7 ° 2630 SF 2630 SF " 2 ° ° ° 2" 2„ SLV ° ° 2" 2" SLV 3/4' 3/4" SLV 3/4» SLV 3/4 SLV 3/4» SLV ° ° ° E- ° CA r�� N LATERAL STUB -UP FO N N CA 16 W PRAY 0) o N DRIP CONNPRIVATE DRIVP 0) 00o LATERAL STUB- OR 19 2 SHRUB DRIP CONNECTION P. 1 1 " 1 Y4" Y4,> LAI „ SPARE WIRES PROVIDE TWO (2) TOTAL SPARE WIRES TO CONTROLLER, WHICH SHALL RUN THROUGH EACH VALVE BOX AS SPECIFIED, AND TERMINATE AT THE FARTHEST VALVE. LOCATE ALL IRRIGATION MAINLINE, LATERALS, AND VALVES WITHIN PLANTING AREAS, UNLESS SLEEVING IS SHOWN, TYP. 3/4" _ ZONE SUMMARY: ZONE GPM SIZE PLANT TYPE 1 33.01 '�i`,.-Q •-T"'� SHRUB i 2 17.58 I_ . ,�; - SHRUB �..��� . I �• !Ill 1" LAWN II 4 36.92 1.5" SHRUB SPRAY 5 25.3 1.5" SHRUB SPRAY 6 22.71 1" SHRUB SPRAY - 19.68 1" SHRUB SPRAY 8 18 1" SHRUB 9 5.2 1" SHRUB DRIP 10 19.68 1" SHRUB SPRAY 11 21.52 � a SHRUB SPRAY 12 4.2 1" SHRUB DRIP 13 38.13 1.5" SHRUB SPRAY 14 18.33 1" SHRUB SPRAY 15 3.6 1" SHRUB DRIP 16 29.26 1.5" SHRUB SPRAY 17 12.11 1" SHRUB SPRAY 18 19.33 1" SHRUB SPRAY 19 6.2 1" SHRUB DRIP 20 12.11 1" SHRUB SPRAY 21 46.56 1.5" SHRUB SPRAY 22 SLV 1 SLV ° ° SLV FOR DRIP 4 ° CO NECTION, 2" TYP. F21 E16 E20 F21 1 F21 E16 E20 F21 SLV �, 8" +, 8" I +18" +18„ � BUILDING 6 BUILDING 7 ° 2630 SF 2630 SF " 2 ° ° ° 2" 2„ SLV ° ° 2" 2" SLV 3/4' 3/4" SLV 3/4» SLV 3/4 SLV 3/4» SLV ° ° ° E- ° CA r�� N LATERAL STUB -UP FO N N CA 16 W PRAY 0) o N DRIP CONNPRIVATE DRIVP 0) 00o LATERAL STUB- OR 19 2 SHRUB DRIP CONNECTION P. 1 1 " 1 Y4" Y4,> LAI „ SPARE WIRES PROVIDE TWO (2) TOTAL SPARE WIRES TO CONTROLLER, WHICH SHALL RUN THROUGH EACH VALVE BOX AS SPECIFIED, AND TERMINATE AT THE FARTHEST VALVE. LOCATE ALL IRRIGATION MAINLINE, LATERALS, AND VALVES WITHIN PLANTING AREAS, UNLESS SLEEVING IS SHOWN, TYP. 3/4" _ ZONE SUMMARY: ZONE GPM SIZE PLANT TYPE 1 33.01 1.5" SHRUB SPRAY 2 17.58 1" SHRUB SPRAY 3 15.22 1" LAWN ROTATOR 4 36.92 1.5" SHRUB SPRAY 5 25.3 1.5" SHRUB SPRAY 6 22.71 1" SHRUB SPRAY 7 19.68 1" SHRUB SPRAY 8 18 1" SHRUB SPRAY 9 5.2 1" SHRUB DRIP 10 19.68 1" SHRUB SPRAY 11 21.52 1" SHRUB SPRAY 12 4.2 1" SHRUB DRIP 13 38.13 1.5" SHRUB SPRAY 14 18.33 1" SHRUB SPRAY 15 3.6 1" SHRUB DRIP 16 29.26 1.5" SHRUB SPRAY 17 12.11 1" SHRUB SPRAY 18 19.33 1" SHRUB SPRAY 19 6.2 1" SHRUB DRIP 20 12.11 1" SHRUB SPRAY 21 46.56 1.5" SHRUB SPRAY 22 32.2 1.5" SHRUB SPRAY 23 SPARE WIRE 24 SPARE WIRE .ISLV- /►��.I/�w m -.. �i� I ■ Mal .I Q - a ®=0110 Mal rl 1.y1 ®DRIP . , SLV SLVSLV1 a • • : ' ► - • '3181 SF •SLV / MI 1� • -1Vi 1119 � ► `■ ►E20 e. ►' � SLV ISLV , ♦. `.... it I iii ,e87.4 SF , !� �d11 � •I I I - KVA I 1UNISI ISI s� . ��'__.✓ �_=_��L��_ai�a►��Q�wLl�lo��0�1�0�:1�o��L� �O.�aerG ERTY LINE IRRIGATION NOTES: 1. ADJUST ALL IRRIGATION HEADS TO PROVIDE MAXIMUM COVERAGE, MINIMUM OVERSPRAY, AND NO FOGGING. SET ALL HEADS BACK FROM CURBS, PAVING, AND WALLS. 2. LOCATION OF IRRIGATION MAINLINE, LATERALS, AND SLEEVING ARE SCHEMATIC ONLY, AND SHALL OCCUR IN PLANTING AREAS UNLESS SLEEVING IS SHOWN. IF SLEEVES ARE SHOWN THEY ARE TO BE STRAIGHT RUNS, TYP. MAKE MINOR CHANGES TO COORDINATE WITH ACTUAL AS -BUILT DIMENSIONS AND CONDITIONS. 3. VALVE BOXES SHALL BE LOCATED IN SHRUB PLANTING AREAS ONLY. LOCATE IN APPROXIMATE LOCATIONS AS SHOWN ON PLAN. 4. SEE CIVIL PLANS FOR LOCATION OF IRRIGATION STUB -OUT FROM 1.5" METER. 5. ANTICIPATED AVAILABLE STATIC WATER PRESSURE IS +/--- PSI, AS PROVIDED BY --- ON ---. VERIFY EXACT PRESSURE AT POINT OF CONNECTION PRIOR TO START OF WORK. 6. THE IRRIGATION SYSTEM HAS BEEN DESIGNED WITH SEPARATE HYDROZONES ACCORDING TO THE NEEDS OF THE PLANT MATERIAL. THE IRRIGATION SYSTEM HAS BEEN DESIGNED TO PROVIDE A MINIMUM AVERAGE DISTRIBUTION UNIFORMITY OF 0.625. THE IRRIGATION SYSTEM HAS BEEN DESIGNED TO AVOID RUNOFF, LOW HEAD DRAINAGE, AND OVERSPRAY. AVOID IRRIGATION DURING TIMES OF HIGH WINDS, WHEN RAINING, OR DURING THE MIDDLE OF THE DAY. 7. WHERE IRRIGATION PIPING IS SHOWN ADJACENT OR UNDER EXISTING TREES, MAKE MINOR ROUTE ADJUSTMENTS TO AVOID TRENCHING THROUGH LARGE TREE ROOTS. REFER TO SPECIFICATION SECTION 02810 FOR FURTHER INSTRUCTIONS. 8. REFER TO IRRIGATION SPECIFICATION FOR ADDITIONAL REQUIREMENTS. SEE SHEET L-201 FOR IRRIGATION LEGEND. SEE SHEETS L-201 & L-202 FOR DETAILS. SCALE: 1 "=20'-0" m 0' 10' 20' 40' 80' SPRAY 2122 SPRAY SHRUB 1.5 1.5 SHRUB 46.5 2.2 STATE OF WASHINGTON NSED PE A CT NICHOLAS PAUL h4AN CERTIFICATE N(!7.753 IRRIGATION PLAN ■ MiIbrandt Architects 25 Central Way, Suite 210 Kirkland, Washington 98033 P:425.454.7130 F:425.658.1208 Web: www.milbrandtarch.com a D 0 N o ~ N T_ w T= CO Q D z i W � 0 C WO 00 Qi c s �Q N J .� m 0U) In e i Fm 2 (D Z z o0� 3 Q 0 (n oC 0 0 U 0 M Q Job No.: 1529 Sheet No.: L-200 IRRIGATIONLEGEND (SYMBOLS SHOWN AT 1"=20'-0") SYMBOL ITEM MANUFACTURER / CAT NO. DESCRIPTION -REMARKS FC -1 CONTROLLER RAINBIRD ESP-24-LXME 24 STATION CONTROLLER, WALL MOUNT INSIDE BUILDING IN HAMMOND, NIBCO, WILKINS GATE VALVE (2"), SEE SPECIFICATIONS, SIZE TO MATCH MAINLINE SIZE. CONTROL VALVE HE -VAN LOCATION AS SHOWN ON PLAN. VERIFY WITH ARCHITECT. ZONE VALVE NUMBER BACKFLOW PREVENTER FEBCO 850U (2") INSTALL PER DETAIL 'B', SHEET L202. GALLONS PER MINUTE CONTROLLER PEDESTAL RAINBIRD LXMM METAL CABINET WITH INSTALL PEDESTAL ON CONCRETE PAD PER PRESSURE REDUCING VALVE ON CONCRETE PAD LXMMPED METAL PEDESTAL. MANUFACTURER'S RECOMMENDATIONS. POWDERCOAT CHAMPION 30ORS-200 ANGLE VALVE (2") FILTER. INSTALL IN APPROXIMATE LOCATION AS SHOWN ON ® QUICK COUPLER FINISH. INSTALL PER DETAIL 'B', SHEET L202. rR-] AUTOMATIC RAIN SHUTOFF RAINBIRD WR2-RFC WIRELESS RAIN/FREEZE SENSOR WITH MOUNTING BRACKET, -12 SERIES HE -VAN SH -2 SWIVEL HOSE ELL AS MOUNT ON ROOF PARAPET IN LOCATION SHOWN ON PLAN. MASTER VALVE RAINBIRD 200-EFB-CP SERIES VALVE (2") OPERATION WILL BE TESTED AT PUNCH LIST REVIEW. NO SYMBOL CONTROL WIRES #14 CONTROL AND SPARE WIRES, NO MULTI -STRAND. SEE SPECIFICATIONS FOR DETAILED REQUIREMENTS. Fm_1 B IRRIGATION METER AND STUB -OUT POINT OF CONNECTION ® CONTROL VALVE GATE / SHUTOFF VALVE HAMMOND, NIBCO, WILKINS GATE VALVE (2"), SEE SPECIFICATIONS, SIZE TO MATCH MAINLINE SIZE. CONTROL VALVE HE -VAN OR APPROVED EQUAL. ZONE VALVE NUMBER BACKFLOW PREVENTER FEBCO 850U (2") GPM GALLONS PER MINUTE STRAINER WILKINS SXL CAST BRONZE 'Y' STRAINER (2") MEDIUM FLOW CONTROL ZONE KIT. MEDIUM FLOW KIT INCLUDES XCZ-100-COM PRESSURE REDUCING VALVE WILKINS 500 -XL PRESSURE REDUCING VALVE (2$$) BALL VALVE, PESB VALVE, AND PRESSURE -REGULATING BASKET DETAIL 'F', SHEET L202. MANUAL DRAIN CHAMPION 30ORS-200 ANGLE VALVE (2") FILTER. INSTALL IN APPROXIMATE LOCATION AS SHOWN ON ® QUICK COUPLER RAINBIRD #5RC PLAN AND PER DETAIL 'C', SHEET L201. HEAD RAINBIRD 55K-1 KEY -PRS -12 SERIES HE -VAN SH -2 SWIVEL HOSE ELL AS REQUIRED, MASTER VALVE RAINBIRD 200-EFB-CP SERIES VALVE (2") 8 ISOLATION VALVE ® CONTROL VALVE O DRIP REMOTE SEE SPECIFICATIONS, SIZE TO MATCH MAINLINE SIZE. CONTROL VALVE HE -VAN 30 PSI ADJUST RADIUS ZONE VALVE NUMBER SIZE VALVE SIZE GPM GALLONS PER MINUTE NO SYMBOL VALVE BOXES NOTES: r 1. ALL DRIPPERLINE TO BE I INSTALLED 1" BELOW TOP OF TOPSOIL LEVEL. 2. MULTIPLE ROWS OF DRIPLINE SHALL BE SPACED AT 18" MAXIMUM O.C. ADJUST ACTUAL SPACING TO PROVIDE AN EVEN SPACING ACROSS THE PLANTED AREA. 3. COORDINATE AND PLACE ALL PLANTINGS SO THAT DRIPPERLINES RUN OVER TOP OF ALL ROOTBALLS. MINIMUM OF 1 PER GROUNDCOVER, 2 PER 5 -GALLON SHRUB, 2 PER TREE. 4. ALL TREES TO BE PLANTED WITHIN CENTER OF DRIPPERLINE RUNS. 5. LAYOUT DRIPLINE SO THAT OUTLETS ARE TRIANGULAR SPACED. 6. MAKE MINOR ADJUSTMENTS IN SUPPLY HEADER, EXHAUST HEADER, AND DRIPLINE LAYOUT TO AVOID CONFLICTS WITH LIGHT POLES, FIRE HYDRANTS, AND OTHER MISC. IMPROVEMENTS. 7. WHERE REMOTE CONTROL VALVE IS SHOWN WITHIN PARKING LOT ISLAND, IT SHALL BE LOCATED AT MID POINT OF ISLAND, ADJACENT TO PARKING STALLS. 8. SEE IRRIGATION NOTES, LEGENDS, AND SPECIFICATIONS FOR ADDITIONAL INFORMATION L PLAN VIEW Q TYPICAL DRIP IRRIGATION LAYOUT MAINLINE LATERALS SLEEVES APPROXIMATE LOCATION, SEE CIVIL DRAWINGS. 200 PSI THREADED ENDS, BRONZE, SCREW IN BONNET, NON -RISING STEM, SOLID WEDGE, INSTALL PER DETAIL 'A', SHEET L202. DOUBLE CHECK VALVE. INSTALL PER DETAIL 'A', SHEET _202. INSTALL AT POINT OF CONNECTION AS PER DETAIL 'A', SHEET L202. INSTALL AT POINT OF CONNECTION AS PER DETAIL 'A', SHEET L202. INSTALL AT POINT OF CONNECTION AS PER DETAILS 'A' AND 'D', SHEET L202. INSTALL AT P.O.C. AND ELSEWHERE AS SHOWN ON PLAN, PER DETAILS 'A' AND 'E', SHEET L202. PROVIDE (2) KEYS AND (2) ELLS. BRASS NORMALLY CLOSED MASTER CONTROL VALVE. INSTALL AT P.O.C. ASSEMBLY PER DETAIL 'A', SHEET _202. HAMMOND, NIBCO, WILKINS BALL VALVE (2"), BRONZE BALL VALVE, INSTALL PER DETAIL 'G', SHEET L202, OR APPROVED EQUAL. 180X SEE SPECIFICATIONS, SIZE TO MATCH MAINLINE SIZE. RAINBIRD XXX-PEB-PRS-D HE -VAN 30 PSI ADJUST RADIUS PLASTIC CONTROL VALVE WITH PRESSURE REGULATING 100- (1"), 150- (1-1/2"), 200- (2") DIAL, INSTALL PER DETAIL 'H', SHEET L202. RAINBIRD DRIP CONTROL ZONES KITS (MEDIUM FLOW) MEDIUM FLOW CONTROL ZONE KIT. MEDIUM FLOW KIT INCLUDES XCZ-100-COM (1"), FOR FLOWS 3.0-14.99 GPM BALL VALVE, PESB VALVE, AND PRESSURE -REGULATING BASKET DETAIL 'F', SHEET L202. FILTER. INSTALL IN APPROXIMATE LOCATION AS SHOWN ON O Q Q p PLAN AND PER DETAIL 'C', SHEET L201. SEE ZONE SUMMARY SPECIFICATION GRADE (COMMERCIAL GRADE) VALVE BOXES AND EXTENSIONS. PVC -SCHEDULE 40 PVC -CLASS 200 PVC -SCHEDULE 40 PVC LATERAL WITH SLEEVE (SEE PLAN FOR SIZES) PVC EXHAUST HEADER, LOCATE WHERE SHOWN ON PLAN AT LOWER END OF EACH PLANTING ISLAND MANUAL LINE FLUSHING VALVE (PLUMBED TO EXHAUST HEADER), OFFSET 18" FROM EDGE OF BED CROSS CONNECT DRIPPERLINE AT EACH TREE ROOTBALL, OR LOOP WHERE DRIPPER LINE IS CENTERED WITH TREE (COORDINATE WITH LANDSCAPE PLAN FOR TREE LOCATIONS) INSTALL FIRST DRIPPERLINE 4"-6" FROM EDGE OF WALK OR CURB 16" TO 18" TYPICAL DRIPPERLINE SPACING, PROVIDE NUMBER OF LINES SHOWN ON PLAN ROUTE PVC LATERAL AND/OR MAINLINE ALONG CURB TO AVOID TREE AND SHRUB ROOTBALLS (COORDINATE WITH PLANTING PLAN) PVC SUPPLY HEADER, END FEED WITH DRIPPERLINE BLANK RISERS, LOCATE WHERE SHOWN ON PLAN PVC LATERAL WITH SLEEVE (SEE PLAN FOR SIZES) Scale: 3/16"=1'-0" SEE SPECIFICATIONS FOR DETAILED REQUIREMENTS. 2" MINIMUM SIZE UNLESS NOTED OTHERWISE, SEE SPECIFICATIONS FOR MINIMUM BURIAL DEPTH. SEE DETAIL 'C', SHEET L202. SIZE AS PER PLAN, 3/4" MINIMUM. UNLABELED PIPE SECTIONS TO MATCH THE LARGEST OF THE ADJACENT PIPES. UNLABELED PIPE AT THE END OF LATERAL RUNS TO BE 3/4". SEE SPECIFICATIONS FOR MINIMUM BURIAL DEPTH. SEE DETAIL 'C', SHEET _202. UNDERPAVEMENT SLEEVING, 4" DIAMETER UNLESS OTHERWISE INDICATED ON PLAN. TO BE INSTALLED BY LANDSCAPE CONTRACTOR AT DEPTHS SPECIFIED. SEE DETAIL 'C', SHEET L202. SPECIFIED RECTANGULAR VALVE BOX, INSTALL TOP OF LID FLUSH WITH FINISH GRADE AUTOMATIC CONTROL VALVE KIT FOR DRIP ZONES (SEE LEGEND FOR TYPE) 24" SPARE WIRE COIL, SEE SPECS FOR QUANTITY C�77 PVC BALL VALVE PVC ADAPTER CONTROL AND SPARE WIRES, TAPE TO BOTTOM OF MAINLINE ELEVATION VIEW RAINBIRD CONTROL ZONE KIT (SEE LEGEND FOR TYPE, 1" SIZE ZONE KIT DEPICTED) BASKET FILTER FINISH GRADE SPECIFIED SPLICE KITS 24" CONTROL WIRE COIL IN BOX INLINE PRESSURE REGULATOR 1" MIN. CLEARANCE BETWEEN VALVE BOX AND PIPE PVC LATERAL PIPE SUPPORT VALVE BOX WITH (4) BRICKS MINIMUM 2 C.F. (12" DEPTH) DRAIN ROCK SUMP IN BOTTOM OF VALVE BOX. NOTE: PROVIDE VALVE BOX EXTENSIONS AS REQUIRED. REMOTE CONTROL VALVE FOR DRIPZONES w z= -D� J p- aw Qf 0 w J [--Q Qry �D 0m LL_ Scale: 1 1/2"=1'-0" SYMBOL ITEM MANUFACTURER / CAT NO. DESCRIPTION -REMARKS O S � ®® ® SPRAY HEAD RAINBIRD 180X -SAM -PRS -15 SERIES HE -VAN 30 PSI ADJUST RADIUS AS REQUIRED, INSTALL PER (1804 - LAWN, 1806 - SHRUB) DETAIL 'F', SHEET L202. O Q Q p SPRAY HEAD RAINBIRD 180x -SAM -PRS -12 SERIES HE -VAN 30 PSI ADJUST RADIUS 'F', AS REQUIRED, INSTALL PER (1804 - LAWN, 1806 - SHRUB) DETAIL SHEET L202. O LDQ � Q [�i SPRAY HEAD RAINBIRD 180x -SAM -PRS -10 SERIES HE -VAN 30 PSI ADJUST RADIUS AS REQUIRED, INSTALL PER (1804 - LAWN, 1806 - SHRUB) DETAIL 'F', SHEET L202. ej) 0�) ® ® ® SPRAY HEAD RAINBIRD 180X -SAM -PRS -8 SERIES HE -VAN 30 PSI ADJUST RADIUS AS REQUIRED, INSTALL PER (1804 - LAWN, 1806 - SHRUB) DETAIL 'F', SHEET L202. 5F 5H or 5Q SPRAY HEAD RAINBIRD 180X -SAM -PRS -5 SERIES MPR 30 PSI ADJUST RADIUS AS REQUIRED, INSTALL PER O 0 L (1804 - LAWN, 1806 - SHRUB) DETAIL 'F', SHEET L202. SST EST LCS or RCS SPRAY HEAD RAINBIRD 180X -SAM -PRS -15 STRIP SERIES MPR 30 PSI ADJUST RADIUS AS REQUIRED, INSTALL PER m I[] FLI 9 (1804 - LAWN, 1806 - SHRUB) DETAIL 'F', SHEET L202. MAROON LT. BLUE OLIVE 90-210 210-270 360 MP ROTATOR HUNTER PROS-06-PRS40-CV- 40 PSI ADJUST RADIUS AS REQUIRED, INSTALL PER �p ® MP3000-90, MP3000-210 or MP3000-360 DETAIL 'F', SHEET L202. (22'-30' RADIUS) DRIP TUBING EH EXHAUST HEADER PIPE SH SUPPLY HEADER PIPE NO SYMBOL LINE FLUSHING VALVE NO SYMBOL STEEL SOIL STAPLE NETAFIM TECHLINE-CV TLCV-06-12-10 PVC - CLASS 200 PVC - CLASS 200 NETAFIM TLSOV MANUAL DRIP SHUT-OFF / FLUSH VALVE NETAFIM TLS6 (6" LENGTH) ROUTE DRIPPERLINE ON TOP OF DRIPPERLINES, TYP. SHRUB OR GROUNDCOVER ROOT BALL SHRUB _ TREE ROOT BALL ROOT BALL - - i 1 1 CROSS CONNECT AT 1 EACH TREE LOCATION, \ WITH DRIPPERLINE \ FITTINGS AS REQUIRED. \ ROUTE LINES ON TOP OF TREE ROOT BALL. SOIL STAPLES PVC HEADER, MALE ADAPTER END FEED CONDITION PVC TEE OR ELL (SUPPLY OR EXHAUST) 6" SPACING SPACING eol PER LEGEND PER LEGEND 6" OFFSET FROM EDGE OF ADJACENT PAVING OR PLAN VIEW BED, UNLESS OTHERWISE NOTED ON PLAN TYPICAL HEADER INSTALLATION BLANK DRIPPERLINE TUBING WITH MALE ADAPTER PVC EXHAUST HEADER - I SPACING PER LEGEND TOP OF VALVE BOX FLUSH WITH FINISH FINISH GRADE SUBSURFACE DRIPPERLINE WITH 12" O.C. EMITTER SPACING WITH EMITTER DISCHARGE OF 0.6 GPH. INSTALL TUBING ROWS AT APPROXIMATELY 16" to 18" SPACING BETWEEN PARALLEL DRIPPER -LINE. ALL TUBING SHALL BE INSTALLED 1" BELOW TOP OF TOPSOIL AND STAKED WITH 6" STAKES AT 3' O.C. VERIFY THE LAYOUT AND SPACING IN THE FIELD PRIOR TO STARTING WORK. FOR ADDITIONAL LAYOUT INFORMATION, SEE DETAILS 'A', 'B', AND 'D', SHEET L201. SUPPLY HEADER SIZE TO MATCH ADJACENT LATERAL LINE (3/4" MINIMUM). EXHAUST HEADER SIZE SHALL BE 3/4" MINIMUM. INSTALL IN LOCATIONS AS SHOWN ON PLAN AND PER DETAILS 'A', 'B', AND 'D', SHEET L201. PROVIDE AND INSTALL MANUAL FLUSH VALVE AT END/MIDDLE OF DRIPLINE, CONNECT TO PVC EXHAUST HEADER. INSTALL FLUSH VALVE INSIDE A SEPARATE VALVE BOX, ONE AT THE END OF TUBING RUNS IN EACH DIRECTION. INSTALL MINIMUM ONE FLUSH VALVE PER 1000 L.F. OF TUBING IN EACH DIRECTION, OR MINIMUM ONE PER EACH PLANTING ISLAND AND EXHAUST HEADER. INSTALL 18" FROM PAVING. INSTALL IN ACCORDANCE WITH MANUFACTURER'S RECOMMENDATIONS. SEE DETAIL 'D', SHEET L201 FOR ADDITIONAL REQUIREMENTS. STAKE AT 3' O.C., PLUS TWO (2) ON EACH TEE, ELBOW OR CROSS. SECTION VIEW OF END FEED CONDITION SPECIFIED 6" ROUND VALVE BOX NETAFIM TECHLINE SHUT OFF VALVE (#TLSOV), OR PVC -7,BALL VALVE SUPPORT VALVE BOX WITH THREE (3) BRICKS MINIMUM 1 C.F. (12" DEPTH) A��DRAIN ROCK SUMP MANUAL FLUSH VALVE (FOR DRIP ZONES Scale: 3"=1'-0" FINISH GRADE MULCH (DEPTH AS SPECIFIED) TOP OF TOPSOIL 4" MAXIMUM 1 " BELOW TOP OF TOPSOIL DRIPPERLINE, TYP. - INSTALL IN TRENCH PRIOR TO PLACEMENT OF MULCH. ADJUST OUTLETS TO MAXIMIZE ROOTBALL SATURATION. SOIL STAPLE AT 3' O.C. MAX. MALE ADAPTER PVC TEE OR ELL AT HEADER PVC HEADER Scale: 1 11/2"=V-0" STATE OF WASHINGTON LASED PE A CT NICHOLAS PAUL h4AN CERTIFICATE N(!7.753 IRRIGATION LEGEND & DETAILS ■ MiIbrandt Architects 25 Central Way, Suite 210 Kirkland, Washington 98033 P:425.454.7130 F:425.658.1208 Web: www.milbrandtarch.com a v O N o ~ N W � C O W Q 55 i c s G � E N 4-0i M Z o0� 3 Q 0 (n OC O � 0 � U M Q Job No.: 1529 Sheet No.: L-2 01 II� METERED STUB FLOW GATE VALVE UNION ELEVATION VIEW SPECIFIED JUMBO—SIZED VALVE BOX, INSTALL FLUSH WITH FINISH GRADE DOUBLE CHECK BACKFLOW PREVENTER UNION 6" MIN. CLR. MINIMUM 6 C.F. (12" DEPTH) DRAIN ROCK SUMP SPECIFIED RECTANGULAR VALVE BOX, INSTALL FLUSH WITH FINISH GRADE STRAINER PRESSURE REDUCING VALVE (ONLY IF SHOWN ON LEGEND) TWO (2) SPECIFIED RECTANGULAR VALVE BOXES, INSTALL FLUSH WITH FINISH GRADE r MANUAL I DRAIN VALVE SPECIFIED 10" ROUND VALVE BOX, INSTALL FLUSH WITH FINISH GRADE QUICK COUPLER VALVE SPECIFIED RECTANGULAR VALVE BOX, INSTALL FLUSH WITH FINISH GRADE MASTER VALVE, INSTALL SIMILAR TO REMOTE CONTROL VALVE DETAIL SUPPORT EACH VALVE BOX WITH (4) BRICKS, TYP. NOTES: 1. PROVIDE ONE QUICK COUPLER AT P.O.C. AND ELSEWHERE AS SHOWN ON PLAN. 2. INSURE POSITIVE DRAINAGE FROM P.O.C. COMPONENTS. PROVIDE DAYLIGHT DRAIN AS NECESSARY. 3. PROVIDE SIZE & QUANTITY OF VALVE BOXES AS NECESSARY TO ACCOMMODATE ALL COMPONENTS. POINT OF CONNECTION SEE IRRIGATION SPECS FOR BACKFILL AND COMPACTION TYPICAL TRENCH SECTION Scale: 1 1/2"=V-0" '-0" SHRUB OR LAWN HEAD TOP FLUSH W/ FINISH GRADE FINISH GRADE I — (2) TH x TH SCH. 40 ELLS W/ 2" x 3/4" SCH. 80 NIPPLE OR (2) MARLEX USE BOTTOM STREET ELLS W/O NIPPLE INLET ONLY 12" x 3/4" SCH. PVC RISER, SAME 80 NIPPLE SIZE AS INLET SCH. 40 TH x TH ELL, OR PVC LATERAL MARLEX STREET ELL BURIAL DEPTH 45` TEE OR PER SPECIFICATIOSN ASCREQUIRED ELL, BUSHING NOTES: 1. TEMPORARILY CAP RISERS FOR PRESSURE TESTING. ELEVATION VIEW 2. SEAL ALL JOINTS W/ TEFLON TAPE ON MALE THREADS ONLY. 3. DO NOT OVERTIGHTEN GALV. TO PVC JOINTS. 4. ALL THREADED PVC PIPE SHALL BE SCH. 80, ALL PVC FITTINGS SHALL BE SCH. 40. 5. NO CLOSE NIPPLES PERMITTED. 6. ALL FITTINGS AND PIPE SAME DIA. AS IPS FEMALE CONNECTION OF SPRINKLER HEAD OR Q.C. 7. INSTALL SO PIPING WILL NOT CONTACT LATERAL. PLAN VIEW IRRIGATION HEAD VC TEE REQUIREMENTS ELL, WITH USHING AS FINISH GRADE VC TH SCH. 80 IPPLE, 3" LONG VC THx TH 90° ELL VC TH SCH. 80 NIPPLE, " LONG ": ;... w — l" MIN. CLEARANCE I NOTES: BETWEEN VALVE BOX AND PIPE P wcn`::' :. P FLOW — 3" MIN. 1. NO OTHER TRADES P CLR. - 0 0 0 0 o 0 0 F— aw (ELECT. LIGHTING) — w = w ... ALLOWED TO USE o w SAME TRENCH AS o �..:. IRRIGATION PIPE. _ PVC NON—PRESSURE 2. PROVIDE 24" - LATERAL LINE PIPE COVER FOR DIRECT PVC PRESSURE BURIAL CABLE. —_ MAINLINE PIPE 3. PROVIDE PVC SCH. :CONTROL WIRE BUNDLE, 40 SLEEVES FOR ALL -� TAPED TO MAINLINE WIRING AND PIPING o UNDER PAVING. 4" CLEAN BACKFILL 4. NO STACKING - _— >> 6 MIN.10 UNDER ALL PIPING, (VERTICALLY) OF SECTION VIEW SEE SPECS FOR IPES IN FRENCH SAME REQUIREMENTS TYPICAL TRENCH SECTION Scale: 1 1/2"=V-0" '-0" SHRUB OR LAWN HEAD TOP FLUSH W/ FINISH GRADE FINISH GRADE I — (2) TH x TH SCH. 40 ELLS W/ 2" x 3/4" SCH. 80 NIPPLE OR (2) MARLEX USE BOTTOM STREET ELLS W/O NIPPLE INLET ONLY 12" x 3/4" SCH. PVC RISER, SAME 80 NIPPLE SIZE AS INLET SCH. 40 TH x TH ELL, OR PVC LATERAL MARLEX STREET ELL BURIAL DEPTH 45` TEE OR PER SPECIFICATIOSN ASCREQUIRED ELL, BUSHING NOTES: 1. TEMPORARILY CAP RISERS FOR PRESSURE TESTING. ELEVATION VIEW 2. SEAL ALL JOINTS W/ TEFLON TAPE ON MALE THREADS ONLY. 3. DO NOT OVERTIGHTEN GALV. TO PVC JOINTS. 4. ALL THREADED PVC PIPE SHALL BE SCH. 80, ALL PVC FITTINGS SHALL BE SCH. 40. 5. NO CLOSE NIPPLES PERMITTED. 6. ALL FITTINGS AND PIPE SAME DIA. AS IPS FEMALE CONNECTION OF SPRINKLER HEAD OR Q.C. 7. INSTALL SO PIPING WILL NOT CONTACT LATERAL. PLAN VIEW IRRIGATION HEAD VC TEE OR ELL, WITH USHING AS REQUIRED VC TH SCH. 80 IPPLE, 3" LONG VC THx TH 90° ELL VC TH SCH. 80 NIPPLE, " LONG Scale: 3"=1'-0" ELEVATION VIEW Scale: 1 1/2"=l' -O" TWO (2) SPECIFIED RECTANGULAR VALVE BOXES WITH LOCKING LIDS. BOLT BOXES TOGETHER FINISH GRADE SPECIFIED DRAIN VALVE MAINLINE PVC WITH THREADED OUTLET .»n PIPE MIN. 18" OFFSET FROM PVC LINE 3" PVC PIPE, THREADED ONE END MIN. 3 C.F. (24" DEPTH) DRAIN ROCK SUMP NOTES: 1. ALL PIPE AND FITTINGS TO BE SAME DIA. AS I.P.S. FEMALE CONNECTION TO DRAIN VALVE. MANUAL DRAIN VALVE FINISH GR SUPPORT EA( WITH (4; Scale: 1 11/2"=V-0" -7 -CIFIED RECTANGULAR -VE BOX, INSTALL FLUSH H FINISH GRADE ELEVATION VIEW PLAN VIEW -CIFIED VALVE MAINLINE, 'TH PER SPECS. IvI ,IMUM 1 C.F. (6" DEPTH) DRAIN ROCK SUMP PVC MAINLINE VALVE BOX SPECIFIED VALVE NOTES: 1. BOX TO BE INSTALLED AS TO ALLOW FOR PROPER OPERATION OF BALL VALVE. INSTALL AT RIGHT ANGLE TO HARDSCAPE EDGE, INSTALL VALVE OFF—CENTER IN BOX. 2. INSTALL VALVE BOX EXTENSIONS AS REQUIRED FOR PROPER VALVE INSTALLATION AT MAINLINE DEPTH. ISOLATION VALVE Scale: 1 1/2"=V-0" '-0" SPECIFIED OF DIRECT BURIAL CONTROL WIRES NOTE: 1. INSTALL GROUNDING ROD AND WIRING PER LEGEND AND PER MANUFACTURER'S RECOMMENDATION. CONTROLLER SPECIFIED 10" ROUND VALVE BOX AND LID 1/4" GALV. U—BOLT 1 " X 16" SCH. 40 PVC PIPE w w FL 0 w Cn U w w w w Cn SUPPORT EACH VALVE BOX WITH (4) BRICKS, TYP. MINIMUM 2 C.F. (12" DEPTH) DRAIN ROCK SUMP RAIN SENSOR SPECIFIED AUTOMATIC IRRIGATION CONTROLLER. WALL MOUNT IN SPECIFIED METAL PEDESTAL CABINET PER MANUFACTURER'S RECOMMENDATION. SEE IRRIGATION PLAN FOR LOCATION. ELECTRICAL CONDUIT FOR POWER SOURCE CONDUIT FOR CONTROL WIRES, MINIMUM SIZE AS SPECIFIED ON IRRIGATION PLANS FINISH GRADE ELEVATION VIEW 3/4"=1'-0" SPECIFIED 10" ROUND VALVE BOX, INSTALL FLUSH WITH FINISH GRADE QUICK COUPLER VALVE FINISH GRADE 1" X 16" SCH. 40 PVC PIPE, SECURE TO QUICK COUPLER WITH 1/4" GALV. U—BOLT BUSHING AS REQUIRED SCH. 80 NIPPLE, VARIABLE LENGTH AS REQUIRED (2) SCH. 80 STREET ELL W/(1) SCH. 80 SHORT NIPPLE (NO MARLEX) PVC SCH. 80 NIPPLE, 8" MIN. LENGTH MAINLINE PVC TH X TH 90 DEG. ELL (NO STREET ELL) NOTES: 1. ALL THE FITTINGS AND PIPE TO BE SAME DIA. AS IPS FEMALE CONNECTION OF QUICK COUPLER. 2. QUICK COUPLER KEY MUST CLEAR VALVE BOX. QUICK COUPLER Scale: 1 1/2"=l' -O" SPECIFIED RECTANGULAR VALVE BOX, INSTALL TOP OF LID FLUSH WITH FINISH GRADE SPECIFIED AUTOMATIC CONTROL VALVE, INSTALL PRESSURE REGULATING DIAL IF SHOWN ON LEGEND " PVC UNION J PROVIDE CORRECT SIZE NIPPLE SO THAT LATERAL LINE COMES RIGHT OUT OF THE BOX WITHOUT USING 90 DEC. ELLS OR 45 DEG. ELL. MAINLINE, SIZE PER PLAN CONTROL AND SPARE WIRES, TAPE TO BOTTOM OF MAINLINE ELEVATION VIEW NOTE: PROVIDE VALVE BOX EXTENSIONS AS REQUIRED. REMOTE CONTROL VALVE PVC LATERAL PIPE w z= _ja- < Ld 10:�0 wJ �Q -iry Qfm 0 w SUPPORT VALVE BOX WITH (4) BRICKS MINIMUM 2 C.F. (12" DEPTH) DRAIN ROCK SUMP IN BOTTOM OF VALVE BOX. Scale: 1 1/2"=V-0" STATE OF WASHINGTON LASED PE A CT NICHOLAS PAUL h4AN CERTIFICATE N `.753 IRRIGATION DETAILS Milbrandt Architects 25 central Way, Suite 210 Kirkland, Washington 98033 P: 425.454.7130 F: 425.658.1208 Web: www.milbrandtarch.com a v O o N T= CO Job No.: 1529 Sheet No.: L-202 \ FINISH GRADE SPECIFIED SPLICE KITS 24" SPARE WIRE — — 24" CONTROL WIRE COIL, SEE SPECS = ; _ COIL IN BOX FOR QUANTITY PVC ADAPTER — l" MIN. CLEARANCE BETWEEN VALVE BOX AND PIPE P P P FLOW — 3" MIN. Yf — P CLR. - 0 0 0 0 o 0 0 o P " PVC UNION J PROVIDE CORRECT SIZE NIPPLE SO THAT LATERAL LINE COMES RIGHT OUT OF THE BOX WITHOUT USING 90 DEC. ELLS OR 45 DEG. ELL. MAINLINE, SIZE PER PLAN CONTROL AND SPARE WIRES, TAPE TO BOTTOM OF MAINLINE ELEVATION VIEW NOTE: PROVIDE VALVE BOX EXTENSIONS AS REQUIRED. REMOTE CONTROL VALVE PVC LATERAL PIPE w z= _ja- < Ld 10:�0 wJ �Q -iry Qfm 0 w SUPPORT VALVE BOX WITH (4) BRICKS MINIMUM 2 C.F. (12" DEPTH) DRAIN ROCK SUMP IN BOTTOM OF VALVE BOX. Scale: 1 1/2"=V-0" STATE OF WASHINGTON LASED PE A CT NICHOLAS PAUL h4AN CERTIFICATE N `.753 IRRIGATION DETAILS Milbrandt Architects 25 central Way, Suite 210 Kirkland, Washington 98033 P: 425.454.7130 F: 425.658.1208 Web: www.milbrandtarch.com a v O o N T= CO Job No.: 1529 Sheet No.: L-202