Loading...
HomeMy WebLinkAboutP_Landscape_Plans_1South_170922_v1TREE INVENTORY CHART 1 ���►► ABBREVIATIONS 0 � � _ _ J.I ARCHITECTS TREE # BOTANIC NAME/ COMMON NAME DBH (IN) DRIPLINE RADIUS (FT) RETAIN/ REMOVE 1 Pinus sylvestris / SCOT'S PINE 17.0 12.0 REMOVE 2 Picea species/ SPRUCE 7.7 11.0 REMOVE 6 Acer macrophyllum/ BIG LEAF MAPLE 8.5 11.0 REMOVE 10 Betula pendula/ EUROPEAN WHITE BIRCH 9.0 10.0 REMOVE 11 Juglans nigra/ BLACK WALNUT 27.3 27.0 REMOVE 12 Malus domestics 'HONEYCRISP'/ HONEYCRISP APPLE 7.2 16.0 REMOVE 14 Sorbus aucuparia/ EUROPEAN MOUNTAIN ASH 10.4 8.0 REMOVE 15 Robinia pseudoacacia/ BLACK LOCUST 8.2 11.0 REMOVE 17 Robinia pseudoacacia/ BLACK LOCUST 10.3 6.0 REMOVE 18 Robinia pseudoacacia/ BLACK LOCUST 7.8 14.0 REMOVE 20 Prunus cerisifera form/ FLOWERING PLUM 7.9 7.0 REMOVE 21 Robinia pseudoacacia/ BLACK LOCUST 14 10.0 REMOVE 22 Robinia pseudoacacia/ BLACK LOCUST 8.9 11.0 REMOVE 23 Robinia pseudoacacia/ BLACK LOCUST 24 6.0 REMOVE 24 Prunus padus/ EUROPEAN BIRD CHERRY 13 18.0 RETAIN 25 Prunus cerisifera form/ FLOWERING PLUM 13 17.3 REMOVE 26 Juglans nigra/ BLACK WALNUT 15.1 18.0 REMOVE 28 Malus domestics 'HONEYCRISP'/ HONEYCRISP APPLE 14.6 14.0 REMOVE 29 Malus domestics 'HONEYCRISP'/ HONEYCRISP APPLE 13.8 11.0 REMOVE 30 Larix occidentalis/ WESTERN LARCH 11.0 14.0 REMOVE 31 Salix species/ WILLOW 12.0 10.0 REMOVE 32 Pseudotsuga menziesii/ DOUGLAS FIR 10.5 6.0 RETAIN TREE INVENTORY NOTES 6 EX TREE LOCATIONS ON THE PLAN & THE INFORMATION IN THE TREE INVENTORY CHART IS BASED ON THE URBAN FORESTRY SERVICES, INC TREE ASSESSMENT DATED NOVEMBER 2, 2016. ONLY TREES WITH SIX (6) IN DBH & GREATER ARE SHOWN. TREE RETENTION WORKSHEET SUMMARY 1. T I C 2. MIN THIRTY-TWO (32) TREES AT TWO (2) IN CALIPER OR SIX (6) FT HEIGHT REQUIRED AS REPLACEMENT TREES. TREE PROTECTION NOTES 1 2 9 -0 no SEE SPEC SECTION 01 56 39 FOR TREE PROTECTION REQUIREMENTS. SIX (6) FT HEIGHT CHAIN LINK, TREE PROTECTION FENCING SHALL BE PROVIDED, SEE PLAN FOR LOCATION. OVERHEAD BRANCHING LIKELY TO BE DAMAGED BY THE OPERATION OF CONSTRUCTION EQUIPMENT SHALL BE BROUGHT TO THE ATTENTION OF THE OWNER'S REP. PREVENTIVE MEASURES (PRUNING OR TIE -BACK OF BRANCHES) AS APPROVED BY THE OWNER'S REP SHALL BE PROPERLY EXECUTED BY AN ISA CERTIFIED ARBORIST BEFORE COMMENCEMENT OF THE CONSTRUCTION ACTIVITIES. CONSTRUCTION STORAGE IN TREE PROTECTION ZONE IS PROHIBITED: DO NOT FILL, EXCAVATE, STACK OR STORE ANY EQUIPMENT, DISPOSE OF ANY MATERIALS, SUPPLIES OR FLUIDS, OPERATE ANY EQUIPMENT, INSTALL IMPERVIOUS SURFACES, OR COMPACT THE EARTH IN ANY WAY WITHIN THE AREA DEFINED BY TREE PROTECTION FENCING. PROTECTED TREES WHICH FAIL TO FULLY FOLIATE, DROPS NEEDLES, OR SHOWS LIMB DIE BACK OF 30% OR MORE OF CANOPY IN THE FIRST YEAR FOLLOWING COMPLETION OF CONSTRUCTION OPERATIONS WILL BE PRESUMED LOST DUE TO CONSTRUCTION OPERATIONS. SEE SPEC SECTION 0156 39. IN THE EVENT THE PROTECTED TREE IS LOST OR DAMAGED, CONTRACTOR SHALL PAY TO THE OWNER'S REP LIQUIDATED DAMAGES PER SPEC SECTION 01 56 39. MIN 22" TREE PROTECTION NO TRESPASS TREE DAMAGE/LOSS = $81000 MIN FEE SECURELY FASTEN TO CHAIN LINK FENCING, TYP TREE PROTECTION SIGN NOT TO SCALE EX VEGETATION TO RETAIN #/NO NUMBER FT FEET & AND IN INCH APPROX APPROXIMATE ISA INTERNATIONAL SOCIETY CENTER LINE OF ARBORISTS CLR CLEAR MIN MINIMUM DBH DIAMETER AT BREAST HEIGHT R PROPERTY LINE DIA DIAMETER REP REPRESENTATIVE DWGS DRAWINGS ROW RIGHT OF WAY EA EACH SPEC SPECIFICATION EQ EQUAL TYP TYPICAL EX EXISTING LEGEND 1 DETAIL IDENTIFICATION L0.01 SHEET IDENTIFICATION M 10 ►1.1.1.1.1.1. PROPERTY LINE FUTURE ROW LINE EX TREES TO BE REMOVED DRIP LINE PER ARBORIST REPORT EX TREES TO RETAIN TREE #NO TREE PROTECTION FENCING EX VEGETATION TO BE CLEARED & GRUBBED , "- d� // /TDCC DD()TC(`TI(1KI 7(IKIC EX VEGETATION TO BE CLEARED & GRUBBED BY HAND WITHIN TREE PROTECTION FENCE; SEE SPEC SECTION 0156 39 FLAGGING STRIPS, TYP TREE PROTECTION SIGN 6' HEIGHT CHAIN LINK FENCE PRIOR TO BEGINNING SOIL PREPARATION, OR SITE SUBGRADE ACTIVITY, HAND DIG TO EXPOSE EX TREE ROOTS AT THE EDGE OF THE PROTECTION FENCE; CLEANLY HAND CUT TREE ROOTS MIN ONE (1) FT FROM TREE PROTECTION FENCE UNDER SUPERVISION OF ISA CERTIFIED ARBORIST, SEE SPEC SECTION 0156 39 TREE PROTECTION DETAIL NOT TO SCALE BEGIN SOIL PREPARATION OUTSIDE TREE PROTECTION FENCE, TYP FINISH GRADE PRIOR TO PLACING MULCH, TYP 14VII I I I SCHREIBER STARLING WHITEHEAD 901 FIFTH AVE N03100 SEATTLE, WA 98164 206-682-8300 SSWARCHITECTS.COM HBC LANDSCAPE ARCHITECTURE 215 WESTLAKE AVENUE NORTH 206.682.3051 phone SEATTLE, WA 98109 206.682.3245 fax Fire Station 15 Conditional Use Permit TREE RETENTION/ TREE INVENTORY PLAN Client Project No.: CAG -17-046 SSW Architects 17001 Project No.: Date: August 18, 2017 L0.01 Nor FIRE STATION PLANT SCHEDULE RESERVOIR PLANT SCHEDULE n Shaded tone area indicates extent area to be cleared, State Of Washington I grubbed, excavated and to receive new topsoil o the M Licensed Botanical Name Common Name Size Notes Quantity depths indicated on Detail J, Sheet L-2 (appro 2,450SF). �� Landscape Architect SYM QTY SCIENTIFIC /COMMON NAMES REMARKS y I NOV: verify location of underground power before avating! �Q I TREES TREES Acer circinatum Vine Maple 5 gal. min. 3' tall, multi trunk 11 aded tone area indicates extent of area to Richard B. Van De Mark Cornus mas Hilliers Upright Cornelian Cherry Dogwood 2 gal. single trunk, B&B 8 be ared, grubbed, excavated and to Certificate No. 481 3 Acer palmatum var. 2" CAL B&B/FABRIC BAG; FULL & WELL I Pseudotsuga menziesii Douglas Fir 5 gal. min. 6' tall, B&B 21 receive topsoil & hydroseed as indicated atropurpureum 'Bloodgood' / BRANCHED; SINGLE -TRUNKED; MIN 4' Thuja plicata Western Red Cedar 5 gal. min. 6 tall, B&B 9 on a 7 et approx 6,200 SF . EVERGREEN SHRUBS P A C g �� ) BLOODGOOD JAPANESE MAPLE BRANCHING HT Gaultheria shallon Salal 1 gal. 48 \ N I Polystichum munitum Sword Fern 1 gal. 34 X X ° Rhamnus frangula 'Columnaris' Tallhedge Buckthorn 5 gal. field located for screen 9 0 ° 3 Nyssa sylvatica'JFS-Red' / 2" CAL; B&B/FABRIC BAG; FULL, WELL Spiraea japonica Japanese Spirea 2 gal. 5 ° ° FIRESTARTER® TUPELO BRANCHED & WELL ROOTED; STRAIGHT I Vaccinium ovatum Evergreen Huckleberry 1 gal. 22 ° Viburnum x bodnantense Bodnant Viburnum 2 gal. 2 CENTRAL LEADER & SINGLE TRUNK; SYMMETRICAL BRANCHING HABIT ----- AAAAAAAA GROUNDCOVERS ° — / -- \ \ \ \ o 0°0°0°0°0°0 0 \\ \ \ wwwwwwwww 0 0 0 0 0 0 0 0 0 0 ® A A A A A A A A �� o°0°0°0°0°0°000°0°0°000°0 \ \ 1 Thuja plicata / 6'-8' HT' B&B/FABRIC BAG; STRAIGHT wwwwwwwww Fragaria chiloensis Beach Strawberry 4 pot to be field located by 216 -° ° ° ° ° ° ° 000 �� \ AAAAAAAA 0000°°00000°°°0°°°000°00000°0°00000 \ \ \ A A A A A A A A A , 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0.-'00-. 0 Owners Rep. 0000°°°°°°°°°°°°°°° AAAAAAAA i 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 \ WESTERN RED CEDAR TRUNK NOT SHEARED; SYMMETRICAL wwwwwwwww ° 0000°°0°0'°0°°° ° - ° 0000°0000°'0.0... / 0 0 0 0 0 0 0 0 0 0 0 0°000°0°0°0° a °0°0000o \ \ \ \ MEADOW SEED MIX O°°° 00000,00°°° \ 0 0 0 0 0 0 x 0 0 0 \ \ / 0 0000000 e / 0 00,000 i FULL &WELL BRANCHED 50% Perennial Ryegrass 8 lbs mix/1,000 SF ° ° ° ° ° ° d° °°° ♦♦♦♦♦♦♦♦ i o 0 0 o o n• 0 0 / I I / I I / I i o 0i" �c °000 I% I I % I I♦/ ° — �� 0°ooQ000a / // 0, 0 0 0 0 20 /° Creeping Red Fescue ° ° -,.0,0-0. 0 / . _ °\ \\ \\ ♦♦♦♦♦♦♦♦ '000000 " '0000,00,00 0 11 11 11 __ 0 d 0 \ 20% Chewings Fescue ' __�, °°°°0°0° / 00.00°°°° \� \ \ `� 9' 000000 .L 0°000000 \ 4' 50 Thuja occidentalis 'Emerald Green'/ 5 GAL CONT STRAIGHT FORM; FULL °r' \\ \ \ 10 / Hard Fescue ' 00000000° e 0°0°000 \ \ I EMERALD GREEN ARBORVITAE WELL BRANCHED & WELL ROOTED I Protect & preserve O °a0 RESERVOIR PLANTING NOTES °°°°° 0000 Tree #24 Prunus__ °o°o °°°o / , \ °0 I 1 + 000.0°o°o°oOo o d °o°o°o° I 1 °o°o°o°o°o°o° + . ROPOSED °O0 °o°I adus 15'Rroot zone 0000°°° °°° 000°0°0°0°0°o °-0-000° 1 1 SHRUBS In , °° 0 0 0 0 RE d' -,-0,-.00..-000.- 0----0----000 O O O 0°O°O°o°0°O O0p0O0 I Note: An automatic irrigation system has not been provided for this design. Drought -tolerant species 00 0,0.00 ° ° '00 ° ° ° ° 0°000°000000 I 000000'.° II I 5 Acer circinatum / 5 GAL CONT; FULL, WELL BRANCHED &WELL and a 8 -inch mat of moisture -retaining topsoil have been specified in lieu of an irrigation system. °°010 \ / 0.00.0.0 VINE MAPLE ROOTED; MULTI -TRUNKED WITH 3 MAIN TRUNKS ° ° ° ° ° Contractor shall monitor the condition of the plant material for a period of one (1) year following °0000o000 \ \ 00000000 ; I acceptance of the work and manually water as necessary. Contractor shall monitor weekly. _ ° °00000000 \: d\ /.d. °0000000 iLih 12 Mahonia aquifolium / 5 GAL CONT; FULL, WELL L _ 000000°° �' °0000000° 00 �, OREGON GRAPE BRANCHED & WELL ROOTED Note: All plant installation to take place between October 15 - March 1st unless authorized by the - - °0.,00000. °� ' °, 0 0 0 0 0 , •-- , 000C,000000 0 0 0 0 0 io00oT O O O O O � + d O O O O O Engineer and Owner. °0000°°°°°°°° °°0000°°°° ° °°°°°°°°°°00 a°o°°°°°o°o 0 0 0 0 0 0 d v o a o 1 5 Ribes sanguineum / 5 GAL CONT FULL WELL ° ° ° °0,00.00.0.C,0;000 ° ° °00000000000 �% 1 0 0 0 0 0° 0 0°°°° ° ° ° ° ° ° ° ° 0 0 ° ° 0 ° ° 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 RED FLOWERING CURRANT BRANCHED &WELL ROOTED ° ° 000000,0 °° ° ° ° ° ° ° ° °° ° ° Maintenance: Enhancement site will be added to the Forest Management maintenance inventor RESERVOIR - ° ° ° ° ° ° ° °'0.60000000°° °° ° ° ° 0 00000000°00000000000°000°0°0000000 -� 0 0 0 0 0 0 0 0 0 0 0 0 y o ° ° ° ° 0 ° °° ° 0000°°°000°°000000°°°00 ° and will be watered and maintained for a minimum of 3 years PLANTING PLAN 00000000 000 °° ° O 70 Brachyglottis greyi 'Sunshine'/ 2 GAL CONT; FULL, WELL DAISY BUSH BRANCHED & WELL ROOTEDLM soma mom5 - - - _ FIRE STATION 11 Euonymus alatus 'Compactus' / 2 GAL CONT; FULL, WELL FIRE STATION PLANTING ABBREVIATIONS PLANTING PLAN --14 COMPACT BURNING BUSH BRANCHED & WELL ROOTED E � ONIF R TRE r� #/NO NUMBER CONT CONTAINER MIN MINIMUM PAR ING -75 0 154 Juniperus x pfitzeriana'Aurea Improved'/ 1 GAL CONT; FULL, WELL % PERCENT DIA DIAMETER OC ON CENTER PROPOSED PROJECT 13 LANTI G, T L1 02 r GOLD COAST JUNIPER BRANCHED & WELL ROOTED & AND DWGS DRAWINGS QTY QUANTITY SEPARATION LINE I @ AT EA EACH REP REPRESENTATIVE r X 114 Mahonia nervosa / 1 GAL CONT; FULL, WELL APPROX APPROXIMATE EQ EQUAL SPEC SPECIFICATION 3 S L PREPARATION IN SHRUB THA CT B&B BALLED & EX EXISTING SQ SQUARE L1.02 & GROUNDCOVER AREAS, TYP TRASH LONGLEAF MAHONIA BRANCHED & WELL ROOTED PHASE INSTALLED BURLAPPED GAL GALLON SYM SYMBOL BY RESERVOIR ENCLOSURE, 0 134 Rosa'Radrazz' / 1 GAL CONT; FULL, WELL CAL CALIPER HT HEIGHT TYP TYPICAL HYDRANT SEE ARCH DWGS r \SEE ARCH DWGS � CONTRACTOR � KNOCK OUT ROSE BRANCHED & WELL ROOTED CLCENTER LINE LF LINEAR FEET W/ WITH GENERATOR, r I I CLR CLEAR MAX MAXIMUM ° • HASE INSTALLED SEE ARCH DWGS " B STATION ARBORVITAE ; : :: r ' ❑ FIRE STATION PLANTING NOTES HEDGE, TYP' '`ti ❑❑ 2 c C�°R 1. ANY DISCREPANCIES W/ THE DWGS AND/OR SPECS & SITE CONDITIONS • o o ° ° °•: ° • R � — ___ _ __ _ - RETAINING SHALL BE BROUGHT TO THE ATTENTION OF THE OWNERS REP PRIOR TO ••e ° \ WALL, TYP, SEE PROCEEDING W/ CONSTRUCTION. -- q 4 CONCRETE MOW STRIP IN I ANDSCAP , TYP i CIVIL DWGS GROUNDCOVERS 2. THE CONTRACTOR IS RESPONSIBLE FOR LOCATING UTILITIES PRIOR TO .° I ° BEGINNING CONSTRUCTION. PROPERTY ° L1.02 RL r 354 50% Gaultheria shallon / 2 GAL CONT; FULL, WELL BRANCHED & WELL 3. PLANT MATERIAL LOCATIONS SHALL BE COORDINATED W/ SPRINKLER LINE / ZONE I u L r r SALAL ROOTED; TRIANGULARLY SPACE @ 24" OC; IRRIGATION HEAD LOCATIONS TO AVOID ANY CONFLICTS. CHANGE TYP _ ° q 5 GRO DCOVER & SH UB PLANTING, TY r r 354 50% Rhus aromatica 'Gro -Low' / INTERMIX BOTH SPECIES I ° ❑ ❑ ❑ �a L1.02 r GRO-LOW FRAGRANT SUMAC 4. INSTALL GROUNDCOVERS IN A TRIANGULAR PATTERN AT SPACING SHOWN I r IN THE PLANT SCHEDULE. WHERE GROUNDCOVER ABUTS CURBING, WALLS, — FIRE STATION BUILDING OR WALKS, MIN PLANTING DISTANCE SHALL BE NINE (9) INCHES FROM SAME R ' 245 Hakonechloa macra Aureola / 1 GAL CONT; FULL, WELL BRANCHED & WELL I (SEE ARCH DWGS) ❑ ❑ ❑ ❑ ❑ ❑ GOLDEN JAPANESE FOREST GRASS ROOTED; TRIANGULARLY SPACE @ 18" OC UNLESS OTHERWISE NOTED. INSTALL GROUNDCOVERS CONTINUOUS IN ' BETWEEN SHRUB PLANTINGS. I 805 Juncus effusus / 1 GAL CONT; FULL, WELL BRANCHED & WELL 5. LANDSCAPE CONTRACTOR SHALL BE RESPONSIBLE FOR ANY I �IDECIDUOUS TREE PLA TING, TYP � SOFT RUSH ROOTEDTRIANGULARLY SPACE @ 12" OC COORDINATION W/ SUBCONTRACTORS AS REQUIRED TO ACCOMPLISH i PATIO L1.02 ; I � � FENCE &MAN PLANTING OPERATIONS. I BOULDER IN LANDSCAPETY r GATE, SEE vv vvvvvvv 133 Pennisetum , alopecuroides Little Bunny'/ 1 GAL CONT; FULL, WELL BRANCHED &WELL 6. PLANTING DRAWING IS BASED UPON SITE BASE DRAWINGS DATED AUGUST ARCH DWGS vvvvvvvvv Ll LITTLE BUNNY FOUNTAIN GRASS ROOTED; TRIANGULARLY SPACE @ 12" OC 10, 2017. PREPARED BY: LPD ENGINEERING PLLC. .02 vvvvvvvvv 7. TREE LOCATIONS SHOWN ON THE PLANTING PLAN ARE APPROXIMATE; IFSLIDING GATEI � --_____ ----------- 504 Prunus laurocerasus'Mt. Veron' / 1 GAL CONT, FULL, WELL BRANCHED & WELL FIELD ADJUSTMENTS ARE NECESSARY THE FOLLOWING MIN SETBACKS FOR , ° - — — — — MT. VERNON ENGLISH LAUREL ROOTED; TRIANGULARLY SPACE 12" OC CENTERLINE OF TREE TRUNKS TO EDGE OF DRIVEWAY FACE OF CURB OR SEE ARCH DWGS I Q RL INTERSECTION AND TO CENTER OF ALL OTHERS SHOWN SHALL APPLY:SSW PROPERTY 2,651 SF SOD LAWN SEE SPECS A. STREET LIGHTS 10' LINE, TYP I 0000 000°° SSW B. DRIVEWAYS 10 _ v °° °Q °° ° °° \ r C. UNDERGROUND SEWER & WATER LINES 5' I °° 7 57 SF MULCH ONLY 3 DEPTH I 0000 D. UNDERGROUND GAS LINES 1' — ` �o° o ° : FUTUR�ROW ::. E. UNDERGROUND HIGH PRESSURE GAS LINES 3' - t .1.. EXTENSION ION �::... SETBACK F. UTILITY/POWER POLES 5' \,....;�: FLAGPOLE, SEE ARCH DWGS BIKE RACKS, SEE FIRE STATION PLANTING LEGEND - :� S O G G G. UNDERGROUND FIBER CABLE 2 , ARCH DWGS H. OTHER TREES 15' - - — --- -- �- - - 1 DETAIL IDENTIFICATION I. FACE OF CURB 3' -- a - - - -- __ a 41PP�U = — L1SHEET IDENTIFICATION .02 --- ---=I i \ V) PROPERTY LINE I o i ----SS----SS---- 5 --------- FUTURE ROW LINE ---SS-- —SS— ----S--—SS----SS--I--SS----SS +�SS ---- SS ---SS. T -_ i � — — — — — — — — — PROPOSED SITE CONTOURS, SEE CIVIL \ NOR 0TH pF WAS \ TB.� ti EX SITE CONTOURS, SEE CIVIL - W W N I � �`� �J�.�EMoti� �o 4-5 MAN LANDSCAPE BOULDER - W - "-- - --- w L— - w---- w— -- w---- w— ' NO 1VZ __-SD----SD__-_ � --SSD--- SD— o Q —SD----SD— — — SD — — — _ , a 40 -- E =--nF— — -- —�— — —0E--- OE O -- — _ �� _ of---- -- —. 66 Q � EXP � P P /H H SCALE DSCAPE P I►� �� TT J.I ARCHITECTS SCHREIBER STARLING WHITEHEAD 901 FIFTH AVE N03100 SEATTLE, WA 98164 206-682-8300 SSWARCHITECTS.COM I I,lop: •-- --.4� ;SII Fire Station 15 Conditional Use Permit PLANTING SCHEDULE, LEGEND, ABBREVIATIONS, NOTES & PLAN Client Project No.: CAG -17-046 SSW Architects 17001 Project No.: Date: August 18, 2017 L1.01 TREETRUNK � I UNDISTURBED EX SOIL OR EX SOIL COMPACTED TO 85% MAX DRY DENSITY, VERIFY POSITIVE oe 12" GREATER DRAINAGE PRIOR TO CONSTRUCTION THAN DIA OF — ROOTBALL nrnTI^AI DECIDUOUS TREE PLANTING NOT TO SCALE TREETRUNK %"-1" WIDE WEBBED FABRIC TAPE (ARBOR TIE OR APPROVED EQUAL), SECURE TO TREE STAKE / WITH #2 PENNY COMMON NAIL (ONE PER STAKE) o TREE STAKE ROOTBALL / LOOP DIAMETER SHALL BE 6"-8" GREATER THAN TREE TRUNK DIAMETER, SECURE LOOP WITH OVERHAND PLAN SLIPKNOT, PULLED AGAINST A SECOND OVERHAND KNOT, TIED ON THE WEBBED FABRIC TAPE (2) 2" DIA WOOD DOWELED TREE STAKES WITH CHAMFERED TOP & 6" CONICAL POINT BOTTOM, KEEP CLEAR OF ROOTBALL WEBBED FABRIC TAPE TOP OF ROOT CROWN TO BE 1" HIGHER THAN FINISH GRADE 3" MULCH DEPTH T~ FINISH GRADE PRIOR TO PLACING MULCH BACKFILL WITH PLANTING SOIL, WHEN HOLE IS HALF FILLED THOROUGHLY WATER SETTLE, THEN ADD REMAINING SOIL AND WATER SETTLE A SECOND TIME 1:1 SLOPE ON SIDES OF PLANTING HOLE AFTER PLACING TREE IN PLANTING PIT, CUT AND COMPLETELY REMOVE STRINGS, TWINE, AND/OR WIRE BASKETS FROM ROOTBALL; COMPLETELY REMOVE FABRIC GROW BAGS; CUT BURLAP FROM TOP 1/3 OF ROOTBALL AND REMOVE CUT BURLAP FROM PLANTING PIT TO PLACING MULCH, 3" DEPTH BARK MULCH, INSTALL TOP OF WOOD CHIP SOD LAWN, BEACH MULCH FLUSH WITH TOP OF ADJACENT CURB OR PAVING ROCK LEVEL WITH TOP OF INSTALL PLANTS ''JACENT CURB OR PAVING FINISH GRADE PLANTING SOIL COMPOST ° r-----1 I I r------ I I Y r— --1 I , M I I I I Q U) I I N I I 0 0 I I I I w - CV UNDISTURBED EXISTING � I UNDISTURBED EX SOIL OR EX SOIL COMPACTED TO 85% MAX DRY DENSITY, VERIFY POSITIVE oe 12" GREATER DRAINAGE PRIOR TO CONSTRUCTION THAN DIA OF — ROOTBALL nrnTI^AI DECIDUOUS TREE PLANTING NOT TO SCALE TREETRUNK %"-1" WIDE WEBBED FABRIC TAPE (ARBOR TIE OR APPROVED EQUAL), SECURE TO TREE STAKE / WITH #2 PENNY COMMON NAIL (ONE PER STAKE) o TREE STAKE ROOTBALL / LOOP DIAMETER SHALL BE 6"-8" GREATER THAN TREE TRUNK DIAMETER, SECURE LOOP WITH OVERHAND PLAN SLIPKNOT, PULLED AGAINST A SECOND OVERHAND KNOT, TIED ON THE WEBBED FABRIC TAPE (2) 2" DIA WOOD DOWELED TREE STAKES WITH CHAMFERED TOP & 6" CONICAL POINT BOTTOM, KEEP CLEAR OF ROOTBALL WEBBED FABRIC TAPE TOP OF ROOT CROWN TO BE 1" HIGHER THAN FINISH GRADE 3" MULCH DEPTH T~ FINISH GRADE PRIOR TO PLACING MULCH BACKFILL WITH PLANTING SOIL, WHEN HOLE IS HALF FILLED THOROUGHLY WATER SETTLE, THEN ADD REMAINING SOIL AND WATER SETTLE A SECOND TIME 1:1 SLOPE ON SIDES OF PLANTING HOLE AFTER PLACING TREE IN PLANTING PIT, CUT AND COMPLETELY REMOVE STRINGS, TWINE, AND/OR WIRE BASKETS FROM ROOTBALL; COMPLETELY REMOVE FABRIC GROW BAGS; CUT BURLAP FROM TOP 1/3 OF ROOTBALL AND REMOVE CUT BURLAP FROM PLANTING PIT STEP 1 STEP 3 STEP 5 EXCAVATE EXISTING SOIL TO 21" DEPTH BELOW INSTALL MINIMUM 15" DEPTH OF SANDY LOAM INSTALL PLANTS. ADJACENT CURB OR PAVING. AVOID PLANTING SOIL IN 3 EQUAL LIFTS. WATER UNDERMINING ADJACENT CURB OR PAVING SETTLE/COMPACT EACH LIFT PRIOR TO STEP 6 SUBBASE MATERIAL. REMOVE SUBBASE FILL INSTALLING THE (STEP 3 CONTINUED) NEXT LIFT. INSTALL 3" DEPTH BARK MULCH. MATERIAL FROM PLANTING AREA AND PROVIDE REVIEW FINISH GRADE WITH OWNER'S REP PRIOR PERCOLATION TEST, PRIOR TO PROCEEDING TO TO PLANTING. NOTES STEP 2. 1. ALL DIMENSIONS INDICATE COMPACTED STEP 4 DEPTHS. STEP 2 INSTALL 3" DEPTH COMPOST AND SCARIFY TO A SCARIFY SUBGRADE TO A MIN 6" DEPTH. OWNER'S MIN 6" DEPTH INTO PLANTING SOIL. OWNER'S REP REP SHALL REVIEW & APPROVE WORK IN WRITING SHALL REVIEW & APPROVE WORK IN WRITING PRIOR TO PROCEEDING TO STEP 3. PRIOR TO PROCEEDING TO STEP 5. tz � SOIL PREPARATION IN SHRUB & GROUNDCOVER AREAS v % NOT TO SCALE TREETRUNK w U� w o= ED J -III I J = mW -I w 11 �11N 0 I z UNDISTURBED EX SOIL OR EX SOIL COMPACTED TO 85% MAX DRY DENSITY, VERIFY POSITIVE DRAINAGE PRIOR TO CONSTRUCTION [1rn-rl^KI 12" GREATER THAN DIA OF ROOTBALL q � CONIFER TREE PLANTING A'- % NOT TO SCALE 1• �;. � .^N STI _ � :.: (2) #4 REBAR 6" OC, 6» CONTINUOUS, MIN 3" CLR nrn-r1nK1 SMOOTH TROWEL FINISH 1/4 RADIUS, BOTH SIDES FINISH GRADE OF PLANTING AREA SHALL BE 4" BELOW TOP OF CONC MOW STRIP #4 VERT REBAR, 24" OC, MIN 3" CLR CAST IN PLACE, REINFORCED, CONCRETE 4" DEPTH MINERAL AGGREGATE PER SPEC 02722 UNDISTURBED SUBGRADE OR FILL COMPACTED TO 95% MAX DRY DENSITY CONCRETE MOW STRIP IN LANDSCAPE "r % NOT TO SCALE nrnTlr'\AI TOP OF ROOT CROWN TO BE FLUSH WITH FINISH GRADE 3" MULCH DEPTH; KEEP MULCH LAYER AWAY FROM FOLIAGE FINISH GRADE PRIOR TO PLACING MULCH LIGHTLY SCARIFY ROOTBALL TO LOOSEN ROOTS PRIOR TO PLANTING 1:1 SLOPE ON SIDES OF PLANTING HOLE BACKFILL WITH PLANTING SOIL, THOROUGHLY WATER SETTLE UNDISTURBED EX SOIL OR EX SOIL COMPACTED TO 85% MAX DRY DENSITY; VERIFY POSITIVE DRAINAGE PRIOR TO CONSTRUCTION PLANTING HOLE TO BE 6" LARGER THAN DIA OF ROOTBALL FOR GROUNDCOVER, 12" LARGER THAN DIA OF ROOTBALL FOR SHRUBS =� GROUNDCOVER & SHRUB PLANTING v % NOT TO SCALE TREETRUNK "-1" WIDE WEBBED FABRIC TAPE (ARBOR TIE OR APPROVED EQUAL), SECURE TO TREE STAKE WITH #2 PENNY COMMON NAIL (ONE PER STAKE) O TREE STAKE ROOTBALL LOOP DIAMETER SHALL BE 6"-8" GREATER THAN TREE TRUNK DIAMETER; SECURE LOOP WITH OVERHAND PLAN SLIPKNOT, PULLED AGAINST A SECOND OVERHAND KNOT, TIED ON THE WEBBED FABRIC TAPE (2) 2" DIA WOOD DOWELED TREE STAKES WITH CHAMFERED TOP & 6" CONICAL POINT BOTTOM; KEEP CLEAR OF ROOTBALL WEBBED FABRIC TAPE TOP OF ROOT CROWN TO BE 1" HIGHER THAN FINISH GRADE — 3" MULCH DEPTH ITS FINISH GRADE PRIOR TO PLACING MULCH BACKFILL WITH PLANTING SOIL, WHEN HOLE IS HALF FILLED THOROUGHLY WATER SETTLE, THEN ADD REMAINING SOIL AND WATER SETTLE A SECOND TIME 1:1 SLOPE ON SIDES OF PLANTING HOLE AFTER PLACING TREE IN PLANTING PIT, CUT AND COMPLETELY REMOVE STRINGS, TWINE, AND/OR WIRE BASKETS FROM ROOTBALL; COMPLETELY REMOVE FABRIC GROW BAGS; CUT BURLAP FROM TOP 1/3 OF ROOTBALL AND REMOVE CUT BURLAP FROM PLANTING PIT BOULDER TO BE FIELD LOCATED BY ENG, SEE PLANS FOR APPROX LOCATIONS & SIZES, SEE SPECS FINISH GRADE PRIOR TO PLACING MULCH, 3" DEPTH BARK MULCH, INSTALL TOP OF WOOD CHIP SOD LAWN, BEACH MULCH FLUSH WITH TOP OF ADJACENT CURB OR PAVING ROCK LEVEL WITH TOP OF INSTALL PLANTS ''JACENT CURB OR PAVING FINISH GRADE PLANTING SOIL COMPOST ° r-----1 I I r------ I I r-----, r ----1 I I I I r— --1 I , M I I I I I I w I I N I I I I I I w - CV UNDISTURBED EXISTING SOIL OR FILL i i i i UJ COMPACTED TO 85% MAXIMUM DRY DENSITY, TYP; VERIFY POSITIVE DRAINAGE PRIOR TO CONSTRUCTION L J1 STEP 1 STEP 2 STEP 3 STEP 4 STEP 5 STEP 6 nrn-rinKI STEP 1 STEP 3 STEP 5 EXCAVATE EXISTING SOIL TO 21" DEPTH BELOW INSTALL MINIMUM 15" DEPTH OF SANDY LOAM INSTALL PLANTS. ADJACENT CURB OR PAVING. AVOID PLANTING SOIL IN 3 EQUAL LIFTS. WATER UNDERMINING ADJACENT CURB OR PAVING SETTLE/COMPACT EACH LIFT PRIOR TO STEP 6 SUBBASE MATERIAL. REMOVE SUBBASE FILL INSTALLING THE (STEP 3 CONTINUED) NEXT LIFT. INSTALL 3" DEPTH BARK MULCH. MATERIAL FROM PLANTING AREA AND PROVIDE REVIEW FINISH GRADE WITH OWNER'S REP PRIOR PERCOLATION TEST, PRIOR TO PROCEEDING TO TO PLANTING. NOTES STEP 2. 1. ALL DIMENSIONS INDICATE COMPACTED STEP 4 DEPTHS. STEP 2 INSTALL 3" DEPTH COMPOST AND SCARIFY TO A SCARIFY SUBGRADE TO A MIN 6" DEPTH. OWNER'S MIN 6" DEPTH INTO PLANTING SOIL. OWNER'S REP REP SHALL REVIEW & APPROVE WORK IN WRITING SHALL REVIEW & APPROVE WORK IN WRITING PRIOR TO PROCEEDING TO STEP 3. PRIOR TO PROCEEDING TO STEP 5. tz � SOIL PREPARATION IN SHRUB & GROUNDCOVER AREAS v % NOT TO SCALE TREETRUNK w U� w o= ED J -III I J = mW -I w 11 �11N 0 I z UNDISTURBED EX SOIL OR EX SOIL COMPACTED TO 85% MAX DRY DENSITY, VERIFY POSITIVE DRAINAGE PRIOR TO CONSTRUCTION [1rn-rl^KI 12" GREATER THAN DIA OF ROOTBALL q � CONIFER TREE PLANTING A'- % NOT TO SCALE 1• �;. � .^N STI _ � :.: (2) #4 REBAR 6" OC, 6» CONTINUOUS, MIN 3" CLR nrn-r1nK1 SMOOTH TROWEL FINISH 1/4 RADIUS, BOTH SIDES FINISH GRADE OF PLANTING AREA SHALL BE 4" BELOW TOP OF CONC MOW STRIP #4 VERT REBAR, 24" OC, MIN 3" CLR CAST IN PLACE, REINFORCED, CONCRETE 4" DEPTH MINERAL AGGREGATE PER SPEC 02722 UNDISTURBED SUBGRADE OR FILL COMPACTED TO 95% MAX DRY DENSITY CONCRETE MOW STRIP IN LANDSCAPE "r % NOT TO SCALE nrnTlr'\AI TOP OF ROOT CROWN TO BE FLUSH WITH FINISH GRADE 3" MULCH DEPTH; KEEP MULCH LAYER AWAY FROM FOLIAGE FINISH GRADE PRIOR TO PLACING MULCH LIGHTLY SCARIFY ROOTBALL TO LOOSEN ROOTS PRIOR TO PLANTING 1:1 SLOPE ON SIDES OF PLANTING HOLE BACKFILL WITH PLANTING SOIL, THOROUGHLY WATER SETTLE UNDISTURBED EX SOIL OR EX SOIL COMPACTED TO 85% MAX DRY DENSITY; VERIFY POSITIVE DRAINAGE PRIOR TO CONSTRUCTION PLANTING HOLE TO BE 6" LARGER THAN DIA OF ROOTBALL FOR GROUNDCOVER, 12" LARGER THAN DIA OF ROOTBALL FOR SHRUBS =� GROUNDCOVER & SHRUB PLANTING v % NOT TO SCALE TREETRUNK "-1" WIDE WEBBED FABRIC TAPE (ARBOR TIE OR APPROVED EQUAL), SECURE TO TREE STAKE WITH #2 PENNY COMMON NAIL (ONE PER STAKE) O TREE STAKE ROOTBALL LOOP DIAMETER SHALL BE 6"-8" GREATER THAN TREE TRUNK DIAMETER; SECURE LOOP WITH OVERHAND PLAN SLIPKNOT, PULLED AGAINST A SECOND OVERHAND KNOT, TIED ON THE WEBBED FABRIC TAPE (2) 2" DIA WOOD DOWELED TREE STAKES WITH CHAMFERED TOP & 6" CONICAL POINT BOTTOM; KEEP CLEAR OF ROOTBALL WEBBED FABRIC TAPE TOP OF ROOT CROWN TO BE 1" HIGHER THAN FINISH GRADE — 3" MULCH DEPTH ITS FINISH GRADE PRIOR TO PLACING MULCH BACKFILL WITH PLANTING SOIL, WHEN HOLE IS HALF FILLED THOROUGHLY WATER SETTLE, THEN ADD REMAINING SOIL AND WATER SETTLE A SECOND TIME 1:1 SLOPE ON SIDES OF PLANTING HOLE AFTER PLACING TREE IN PLANTING PIT, CUT AND COMPLETELY REMOVE STRINGS, TWINE, AND/OR WIRE BASKETS FROM ROOTBALL; COMPLETELY REMOVE FABRIC GROW BAGS; CUT BURLAP FROM TOP 1/3 OF ROOTBALL AND REMOVE CUT BURLAP FROM PLANTING PIT BOULDER TO BE FIELD LOCATED BY ENG, SEE PLANS FOR APPROX LOCATIONS & SIZES, SEE SPECS FINISH GRADE PRIOR o wQ SECTION 4" DEPTH CRUSHED SURFACING BASE COURSE COMPACTED TO 95% MAX DRY BOULDER IN LANDSCAPE 6 NOT TO SCALE I►� �� TT J.I ARCHITECTS SCHREIBER STARLING WHITEHEAD 901 FIFTH AVE N03100 SEATTLE, WA 98164 206-682-8300 SSWARCHITECTS.COM H 6-f� LANDSCAPE ARCHITECTURE 215 WESTLAKE AVENUE NORTH 206.682.3051 phone SEATTLE, WA 98109 206.682.3245 fax F WAS vcl/v � co r U s� 8s Q � EXP � Fire Station 15 Conditional Use Permit LANDSCAPE DETAILS Client Project No.: CAG -17-046 SSW Architects 17001 Project No.: Date: August 18, 2017 L1.02 TO PLACING MULCH, Q SOD LAWN, BEACH SAND OR COBBLE Mo N ROCK O X o wQ SECTION 4" DEPTH CRUSHED SURFACING BASE COURSE COMPACTED TO 95% MAX DRY BOULDER IN LANDSCAPE 6 NOT TO SCALE I►� �� TT J.I ARCHITECTS SCHREIBER STARLING WHITEHEAD 901 FIFTH AVE N03100 SEATTLE, WA 98164 206-682-8300 SSWARCHITECTS.COM H 6-f� LANDSCAPE ARCHITECTURE 215 WESTLAKE AVENUE NORTH 206.682.3051 phone SEATTLE, WA 98109 206.682.3245 fax F WAS vcl/v � co r U s� 8s Q � EXP � Fire Station 15 Conditional Use Permit LANDSCAPE DETAILS Client Project No.: CAG -17-046 SSW Architects 17001 Project No.: Date: August 18, 2017 L1.02 IRRIGATION LEGEND 1 1 SYM DESCRIPTION 1 PERMANENT IRRIGATION FLOW SENSOR I � 334 -3226 1 DRAIN VALVE DOUBLE CHECK I PARCEL # 1 'ZONE 1 ' IRRIGATION ZONE VALVE ASSEMBLY I PARC X33421 3239 QUICK COUPLER EX 3/4" WATER 1 � METER - SEE -------- X7, x x — — — — — — — IRRIGATION SLEEVESCH 40 PVC OR SCH PVC MAINLINE ( CIVIL DWG - - — — — — — — 80 PVC) AS NOTED ON DRAWING; TBD ,,,,,,,„,,,,,,,,,,,,,,,,,,,,,,,,,,,,, ,,,,,,,,,, ,,,,,,,,,,,,,, ,,,,,,,,, ,,,,,,,,094 ,„,,,,,,,,,,,,,,,,,,,,,,,,,,,,, M POINT OF CONNECTION x MASTER CONTROL VALVE 0 © IRRIGATION CONTROLLER IRRIGATION POINT OF CONNECTION - ED ONNECTION❑M 3/4” EX WATER METER NOT TO SCALE 10 @ GATE VALVE NO IRRIGATION x A DETAIL IDENTIFICATION AT RESERVOIR L-1 SHEET IDENTIFICATION x PROPERTY LINE ------- FUTURE ROW LINE zo PROPOSED SITE CONTOURS, SEE CIVIL Q w c� EX SITE CONTOURS, SEE CIVIL > ZONE 6 - SHRUB MIX / 7777, IRRIGATION ABBREVIATIONS (TBD /o E PERCENT MIN MINIMUM / j/ / o // j/ %�,�/ GATE VALVE TO PAR ING /N BE INSTALLED & AND OC ON CENTER j/ 13 / /jj/j�/j AT TRANSITION @ AT POC POINT OF CONNECTION BETWEEN #/NO NUMBER PVC POLYVINYL CHLORIDE �. �� �� n ARCH ARCHITECTURAL PSI POUNDS PER SQUARE INCH T( A INSTALLATIONS CL CENTER LINE S SLIP ✓ZONE 7 - TRASH COR CITY OF RENTON SCH SCHEDULE SHRUB MIX PHASE INSTALLED ENCLOSURE, DIA DIAMETER SPEC(S) SPECIFICATION(S) ��. HYDRANT, SEE ARCH DWGS BY RESERVOIR r // // / SEE ARCH DWGS CONTRACTOR /Y DWGS DRAWINGS T THREAD �/ \ -- GENERATOR // EX EXISTING TBD TO BE DETERMINED AT � ASE INSTALLED ��/SEE ARCH DWGS GPM GALLONS PER MINUTE DESIGN DEVELOPMENT / / ZONE 4 -SOD./ / / \ / . , .. , , . � ^ BY STATION IRR IRRIGATION TYP TYPICAL n // i/j L LENGTH W WIDTH / // / / /./// C6 R MAX MAXIMUM W/ WITH j j / '�f - --� �� ZONE 3 - o //j�/ MFRS MANUFACTURERS / / ; .� SHRUB MIX i — ---- - - -- =- = —----- / / RETAINING ---a-�-- ///////7777 7// 7 77­� WALL, TYP, SEE ZONE.3 = .y I // CIVIL DWGS R R I GAT I O N NOTES isHRUB MIX/ -RL ZONE 5 -� PROPERTY /,. LINE / ZONE j%/ j j,�%' ;SHRUB 1. THERE IS A LOSS OF PRESSURE IN EACH PIPE FITTING DUE TO FRICTION. THESE CHANGE TYP x�j/% j ; R� MIX //// LOSSES ARE COMPENSATED FOR BY ADDING TEN (10) PERCENT TO THE ////// FIRE STATION BUILDING MANUFACTURERS RATED GPM FOR EACH NOZZLE. — PATIO (SEE ARCH DWGS) 2. LOCATE AUTOMATIC CONTROL VALVES IN PLANTING AREAS AT POINT OF EASY / R ACCESS. OWNER'S REPRESENTATIVE TO REVIEW & APPROVE FINAL LOCATION OF ' EXTERIOR &WALL MOUNT m/ j / / FENCE & MAN ALL QUICK COUPLERS & AUTOMATIC CONTROL VALVES PRIOR TO INSTALLATION. / ; IRRIGATION CONTROLLERyYj j GATE, SEE 3. CONTRACTOR SHALL COORDINATE IRRIGATION EQUIPMENT WITH PLANT / I. ARCH DWGS MATERIAL, TO AVOID CONFLICTS, SPRAY BLOCKAGE & ANY OTHER ITEMS DEEMED / FLAGPOLE, SEE ARCH DWGS APPROPRIATE BY THE OWNER'S REPRESENTATIVE. j BIKE RACKS, SEE RL 4. EX STATIC PSI AT WATER METER IS PSI. INFORMATION PROVIDED BY TELEPHONE RECEIVED ON (PSI IS APPROXIMATELY 98 PSI AT j / j j ARCH DWGS ELEVATION 210' PER CITY OF RENTON PRE -APPLICATION MEMORANDUM DATED 18 Co ---------- 4----- -- MAY, 2017). PRIOR TO INSTALLATION OF IRRIGATION SYSTEM, CONTRACTOR SHALL SLIDING GATE, / _ _ _ -- ---- �/ �� ' RL j� UTURE R W FIELD VERIFY EX PSI. NOTIFY OWNER'S REPRESENTATIVE OF ANY DISCREPANCIES SEE ARCH DWGS // // / TENSION BETWEEN THE DESIGN PSI & EX PSI PRIOR TO PROCEEDING WITH WORK. c - �` - - - IRRIGATION PROPERTY P / ./ //I /. j�// S BACK 5. SYSTEM DESIGNED TO PSI SPRAY HEADS ZONE 2 //� / SLEEVE, TYP / / / ( ) LINE, TYP / / 6. DRAWING IS SCHEMATIC. ACTUAL LOCATIONS MAY VARY DUE TO PLANT SHRUB MIX GATE VALVE TO GATE VALVE TO � /�!' ��- � / MATERIALS OR SITE CONDITIONS. %/ //j/ // j/ //I BE INSTALLED 7. IRRIGATION CONTRACTOR SHALL COORDINATE IRRIGATION SLEEVING LOCATIONS BE INSTALLED / ./ // // / / .// — — — — — _ �i%/, j/ AT TRANSITION WITH GENERAL CONTRACTOR. AT TRANSITION — j// j / \ ZONE 1 / TO AREA FOR 8. ALL IRRIGATION SLEEVING TO BE STAKED IN THE FIELD & REVIEWED BY OWNER'S TO AREA FOR / / SOD j / FUTURE ROW REPRESENTATIVE PRIOR TO INSTALLATION. LOCATE SLEEVES ON DIMENSIONED FUTURE ROW / j jj%jjjj/�/ /j�'j�/ 7j EXTENSION EXTENSION _ o ./ j j/ /j///jZONE 1 - SOD; /j E E /// / REMOVAL AS -BUILT DRAWING TO ALLOW FOR FUTURE LOCATION & USE. ON AS -BUILT / // �./ / // (REMOVAL) DRAWING, MAINLINE SHALL BE DIMENSIONED FROM ROADWAY CURB @ 30' OC TO (REMOVAL) / —T — — ALLOW FOR FUTURE LOCATION. MA7 < SPP/L1 --- 9. CONTRACTOR TO AIR BLOW IRRIGATION SYSTEM THROUGH QUICK COUPLERS TO -- WINTERIZE IRRIGATION SYSTEM IN FIRST SEASON. - IRRIGATIO PbINT 0 ONNEC N 3/4" EX WATER METER (TO BE 1 i --- ss ---- ss--- s-�_---ss__�REUSED FOR IRRIGATION POC) -- —ss--I--ss----ss +�}pss ss ---ss--ss--- S -4 ---Ss NOR TH - - � I —w— — — — w---- w — w---- w-- ---- w vJ__ — w---- w— -- w---- w---- w— I-- w — —— w- ---SD---- UI -- W---- SD ----S I --SSD--- SD-- — SD— — —— — SD— --- SD— — P La -- – -- --- – -- ---- 4---E--� E OE— --0 OE — -- ---=--nF— — QE ----OF — 0E— — —— —_ — — QE-- _ PP/UG 7— — — — NO S LE M LANDSCAPE ARCHITECTURE 215 WESTLAKE AVENUE NORTH 206.682.3051 phone SEATTLE, WA 98109 206.682.3245 fax F WAS �� SET B . VpNC�G,� �� a�] b� - r U �gNneroPE P Fire Station 15 Conditional Use Permit IRRIGATION LEGEND, DETAIL, ABBREVIATIONS, NOTES & PLAN Client Project No.: CAG -17-046 SSW Architects 17001 Project No.: Date: August 18, 2017 L2.01 _ _ J►I ARCHITECTS SCHREIBER STARLING WHITEHEAD 901 FIFTH AVE N03100 SEATTLE, WA 98164 206-682-8300 SSWARCHITECTS.COM M LANDSCAPE ARCHITECTURE 215 WESTLAKE AVENUE NORTH 206.682.3051 phone SEATTLE, WA 98109 206.682.3245 fax F WAS �� SET B . VpNC�G,� �� a�] b� - r U �gNneroPE P Fire Station 15 Conditional Use Permit IRRIGATION LEGEND, DETAIL, ABBREVIATIONS, NOTES & PLAN Client Project No.: CAG -17-046 SSW Architects 17001 Project No.: Date: August 18, 2017 L2.01