Loading...
HomeMy WebLinkAboutP_FloorPlanOverall_BuffaloDesign_170724_v1SHOWER(NO WORK)LOBBY(NO WORK)MEN(NO WORK)WOMEN(NO WORK)TELEPHONE(NO WORK)3TELEPHONE(NO WORK)SHOWER(NO WORK)JANITOR(NO WORK)TENANTSPACENO WORKTENANTSPACENO WORK12WOMEN(NO WORK)TELEPHONE(NO WORK)4567AFISRECEPTION132KCS WAITING107CLEANPROCESSING113EVIDENCE HOLDING117TENANTSPACENO WORKAFISADMINISTRATION130OFFICE108AFIS WAITING133KCS GENERAL OFFICE109KCS PHOTOGRAPHY LABORATORY111ALS CAMERA ROOM101POWDER PROCESSING114HALL116OFFICESUPERVISOR128EVIDENCE VIEWING115EMPLOYEEBREAK AREA126JANITOR/STORAGE119LATENT PROCESSING LABORATORY103HALL105VESTIBULE121CORRIDOR141VEHICLE PROCESSING FACILITY107CORRIDOR118HALL129HALL102WOMENS TOILET122WOMENSSHOWER123MENSSHOWER125MENS TOILET124EVIDENCE ARCHIVES142STORAGE137CORRIDOR141TRAININGROOM138AHALL140BREAKOUT136STORAGE144PHOTO ARCHIVES139STORAGE112OFFICE CENTER131TRAININGROOM138BKCS PHOTO STUDIO110REQUIRED DIAGONAL EXIT SEPARATION = 311'-0"/ 3 = 103'-0"life safety plana002construction documentsOFlw cc 7/24/2017 2016-018king county regional afis lab replacement 900 oakesdale sw renton, wa 1520 fourth avesuite 400seattle, wa98101206 467 6306buffalodesign.comarchitecture | interiorsking county project no:CO1187C17project informationlegendSCALE:life safety plan1/16" = 1'-0"OCCUPANT LOAD CALCULATION TABLE 1004.1.2GROUP AREAFACTOROCCUPANT LOADB OFFICE22,040 SF100 GROSS220B TRAINING 2,075 SF 15 GROSS138F-1 INDUSTRIAL 3,065 SF100 GROSS 31TOTAL389 (195 M + 195 F)FLOOR AREA - LEVEL 1AREA OF TENANT IMPROVEMENTS15,585 SFAREA OF NO WORK 8,530 SFTOTAL EXISTING FLOOR AREA24,115 SFVPF ADDITION / VEHICLE PROCESSING FACILITY 3,065 SF TOTAL PROJECT AREA27,180 SFPLUMBING FIXTURE CALCULATION CODE: IBC TABLE 2902.1 WASHINGTON STATEAMENDMENTSPROPOSEDAREAFACTOROCC. LOADMALE FEMALE LAVATORIESDFTOTAL FIXTURES4 + 2U682PARTIAL HEIGHT WALLNEW NON-RATED WALLSYMBOLDESCRIPTION1 HOUR FIRE RATED WALL2 HOUR FIRE RATED WALLNEW WORK1 HOUR AREA SEPARATIONEXIT(E) NON-RATED WALLEXISTING WC3 + 1U462NEW WC1 + 1U22REQUIREDAREAFACTOROCC. LOADMALE FEMALE LAVATORIES DFTABLE 2902.14 + 1U58211CHAPTER 3 ICC A117.1-2009: BUILDING BLOCKS :FLOOR SURFACES:CARPET AND SHEET VINYL SPECIFIED WILL BE INSTALLED TO MEET THE REQUIREMENTS PER ICC A117.1-2009 SECTION 302.CHANGES IN LEVEL:THE CARPET TO VINYL TRANSITION IS LESS THAT 1/4". THE THRESHOLD AT THE EXTERIOR ENTRY DOORS IS LESS THAN 1/2".CLEAR FLOOR SPACE:REFER TO THE LIFE SAFETY PLAN FOR TURING CLEARANCES AND ACCESSIBLE ROUTES OF TRAVEL AS REQUIRED PER ICC A117.1-2009 SECTION 304 .TOE AND KNEE CLEARANCES:REFER TO THE RESTROOM INTERIOR ELEVATIONS 1,2,3 & 4 ON SHEET a203 FOR CLEARANCES AS REQUIRED PER ICC A117.1-2009 SECTION 306PROTRUDING OBJECTS:THERE ARE NO PROTRUDING OBJECTS ON THE WALLS. DOOR CLOSERS AND OVERHEAD DOOR STOPS ARE LOCATED 78" AFF AS REQUIRED PER ICC A117.1-2009SECTION 307.CHAPTER 4 ICC A117.1-2009: ACCESSIBLE ROUTESREFER TO THE LIFE SAFETY PLAN a002 FOR FLOOR CLEARANCES. REFER TO SHEET a601 FOR DOOR HARDWARE SPECIFICATIONS: ALL HANDLES, PULLS, LATCHES ANDOPERABLE PARTS ARE CODE COMPLIANT AS REQUIRED BY ICC A117.1-2009 CHAPTER 4 .CHAPTER 5 ICC A117.1-2009: GENERAL SITE AND BUILDING ELEMENTSPARKING SPACES:ADA COMPLIANT PARKING SPACES ARE EXISTING. REFER TO THE SITE PLAN ON SHEET a100.CHAPTER 6 ICC A117.1-2009: PLUMBING ELEMENTS AND FACILITIESREFER TO INTERIOR ELEVATIONS 1,2,3, 4 & 5 ON SHEET a204. THE RESTROOMS MEET THE REQUIREMENTS OF ICC A117.1-2009 CHAPTER 6.summary of accessibility requirements