HomeMy WebLinkAboutP_Site_Plan_170717_v1CAR WORKS ADD TO RENTON LOTS 11,12, 13 TGW PORTION
OF LOT 14 LY NLY OF A LINE DAF - BEGIN NE CORNER OF LOT
14 TH S 18 FT TO BEGINNING OF LINE TH S 89-49-20 W 73 FT
TH S 00-18-00 W 6 FT TH S 82-14-50 W 30.30 FT TO W LINE OF
LOT 14 TO TERMINUS OF SAID LINE
PLAT BLOCK: 1
PLAT LOT: 11-12-13-14
LEGAL DESCRIPTION
APPROVED BY
CONSTRUCTION MANAGER
DATE SIGNATURE
PROJECT MANAGER
SITE ACQUISITION
ZONING
APPROVAL / SIGN OFF
PROJECT CONTACT LIST
PROJECT INFORMATION
UTILITY COMPANIES
THE INFORMATION CONTAINED IN THIS SET OF
CONSTRUCTION DOCUMENTS IS PROPRIETARY BY NATURE.
ANY USE OR DISCLOSURE OTHER THAN THAT WHICH
RELATES TO VERIZON WIRELESS SERVICES IS STRICTLY
PROHIBITED.
PROPRIETARY INFORMATION
RF
LDC, INC.
CONTACT: RICHARD B. HALL, AIA
PHONE: (425) 806-1869
EMAIL: rhall@ldccorp.com
PROJECT ARCHITECT:
APPLICANT:PROPERTY OWNER:
REVIEWERS SHALL CLEARLY PLACE INITIALS ADJACENT TO
EACH REDLINE NOTE AS DRAWINGS ARE BEING REVIEWED
FROM VERIZON WIRELESS OFFICE:
x GET ON I-90 W FROM SE EASTGATE WAY
x HEAD EAST TOWARD 158TH AVE SE
x TURN RIGHT ONTO 158TH AVE SE
x TURN RIGHT ONTO SE EASTGATE WAY
x TURN LEFT ONTO THE I-90 W RAMP TO SEATTLE
x KEEP LEFT, FOLLOW SIGNS FOR I-90 W/SEATTLE AND MERGE
ONTO I-90 W
x TAKE I-405 S TO WA-900/SUNSET BLVD N IN RENTON. TAKE
EXIT 4 FROM I-405 S
x MERGE ONTO I-90 W
x TAKE EXIT 10 FOR INTERSTATE 405 S TOWARD RENTON
x MERGE ONTO I-405 S
x TAKE EXIT 4 FOR WA-900 W TOWARD WA-169
S/RENTON/ENUMCLAW
x CONTINUE ON WA-900/SUNSET BLVD N. DRIVE TO BRONSON
WAY N
x MERGE ONTO WA-900/SUNSET BLVD N
x TURN RIGHT ONTO BRONSON WAY N
x TURN LEFT ONTO MEADOWS AVE N
x DESTINATION WILL BE ON THE LEFT
DRIVING DIRECTIONS
VERIZON WIRELESS
3245 158TH AVENUE SE
BELLEVUE, WA 98008
VERIZON WIRELESS PROPOSES TO INSTALL A TEMPORARY CELL ON
WHEELS (COW) TELECOMMUNICATIONS FACILITY WITH PANEL ANTENNAS,
AND MICROWAVE WITHIN A TEMPORARY FENCED COMPOUND.
MICROWAVE
(ON SITE)
TELEPHONE:POWER:
PUGET SOUND ENERGY
PHONE: (888) 225-5773
ZONING CLASSIFICATION:
CODE INFORMATION:
CA (COMMERCIAL ARTERIAL)
BUILDING CODE:IBC 2015
CONSTRUCTION TYPE:IIB
OCCUPANCY:U, S-2
JURISDICTION:CITY OF RENTON
PROPOSED BUILDING USE: UNMANNED TELECOM
LATITUDE:
SITE LOCATION (NAD83):
47° 29' 05.00" N
LONGITUDE:122° 11' 58.08" W
TOP OF STRUCTURE:86.00'± AMSL
BASE OF STRUCTURE:41.00'± AMSL
TBD
PROJECT LEASE AREA:
1352300060
PARCEL NUMBER:
0.33 ACRES
AREA OF PARCEL:
N/A
NEW IMPERVIOUS AREA:
1. PARKING REQUIREMENTS ARE UNCHANGED.
2. TRAFFIC IS UNAFFECTED.
3. SIGNAGE IS UNAFFECTED.
GENERAL INFORMATION:
PROJECT DESCRIPTION:
45.0' AGL
0.0' AGL
(47.484722° N)
(122.199466° W)
VICINITY MAP
NOT TO SCALE
GENERAL LOCATION MAP
NOT TO SCALE
PROJECT
PROJECT
BRYANT MOTORS INC.
1300 BRONSON WAY N
RENTON, WA 98055
CONTACT: KEN BRYANT
PHONE: (425) 255-3478
TITLE SHEET
T-1.0
LANDLORD
1300 BRONSON WAY N
RENTON, WA 98055
SEA CEDAR RIVER COW
DRAWING INDEX
DWG NO.DESCRIPTION
T-1.0 TITLE SHEET
A-1.0 SITE PLAN
A-2.0 ENLARGED SITE PLAN
A-3.0 ELEVATIONS
DO NOT SCALE DRAWINGS. CONTRACTOR MUST VERIFY
ALL DIMENSIONS AND ADVISE CONSULTANTS OF ANY
ERRORS AND OMISSIONS. ALL PREVIOUS ISSUES OF THIS
DRAWINGS ARE SUPERSEDED BY THE LATEST REVISION.
LDC TAKES NO RESPONSIBILITY FOR ADEQUACY OF
TOWER MOUNTS FOR EXISTING OR PROPOSED LOADING.
CONTRACTOR AND MOUNT MANUFACTURER TAKE FULL
RESPONSIBILITY FOR MOUNTING PRODUCTS USED &
THEIR ADEQUACY. MOUNTS SHOWN IN DRAWINGS ARE
FOR ILLUSTRATIVE PURPOSES ONLY.
DISCLAIMERS
SHEET NUMBER
SUBMITTALS
DATE:
DRAWN BY:
CHECKED BY:
SITE
DESCRIPTION BYDATE
SHEET TITLE
REV
SEA CEDAR RIVER COW
1300 BRONSON WAY N
RENTON, WA 98055
6-28-17
RJG
RBH
1 6-28-17 PRELIMINARY ZONING RJG
2 7-10-17 FINAL ZONING ENS
APPROVAL STAMP
Structural
Engineering
Architectural
www.LDCcorp.com
20210 142nd Ave NE
Woodinville, WA 98072
THE CIVIL ENGINEERING GROUP
Fx. 425.482.2893
Ph. 425.806.1869
Survey
8828
LDC, INC.
CONTACT: RICK CARDOZA
PHONE: (253) 218-9017
EMAIL: rcardoza@ldccorp.com
PROJECT ARCHITECT:
1
1
ZONING:
ADJACENT ZONING:
ZONING MAP
NOT TO SCALE
PROPOSED QUANTITIES
POWER LENGTH:
±18'
FIBER/TELCO LENGTH:N/A
ROAD LENGTH:N/A
UNDERGROUND:
OVERHEAD:±18'
SITE PLAN
22"x34" SCALE: 1" = 20'11"x17" SCALE: 1" = 40'
PROJECT
CA
PROPOSED VERIZON WIRELESS
ANTENNAS AND MICROWAVE MOUNTED
ON CELL ON WHEELS (COW) WITHIN A
TEMPORARY FENCED COMPOUND
EXISTING SITE ACCESS
SITE PLAN
A-1.0
CA (COMMERCIAL ARTERIAL)
R-10 (RESIDENTIAL 10 DU/AC)
SHEET NUMBER
SUBMITTALS
DATE:
DRAWN BY:
CHECKED BY:
SITE
DESCRIPTION BYDATE
SHEET TITLE
REV
SEA CEDAR RIVER COW
1300 BRONSON WAY N
RENTON, WA 98055
6-28-17
RJG
RBH
1 6-28-17 PRELIMINARY ZONING RJG
2 7-10-17 FINAL ZONING ENS
APPROVAL STAMP
Structural
Engineering
Architectural
www.LDCcorp.com
20210 142nd Ave NE
Woodinville, WA 98072
THE CIVIL ENGINEERING GROUP
Fx. 425.482.2893
Ph. 425.806.1869
Survey
8828
CA
CA
CA
CA
CA
ADJACENT ZONING:
CA (COMMERCIAL ARTERIAL)
ADJACENT ZONING:
CA (COMMERCIAL ARTERIAL)ADJACENT ZONING:
CA (COMMERCIAL ARTERIAL)
ADJACENT ZONING:
CA (COMMERCIAL ARTERIAL)
R10R10R10
18'±
TOWER SETBACK
117'±TOWERSETBACK79'±
TOWER SETBACK
24'±
TOWER SETBACK
1
1
ENLARGED SITE PLAN
22"x34" SCALE: 1/4" = 1'-0"11"x17" SCALE: 1/8" = 1'-0"
EXISTING SITE ACCESS
SECTOR3:290°SECTOR1:40°SECTOR2:165°ENLARGED SITE PLAN
A-2.0
SHEET NUMBER
SUBMITTALS
DATE:
DRAWN BY:
CHECKED BY:
SITE
DESCRIPTION BYDATE
SHEET TITLE
REV
SEA CEDAR RIVER COW
1300 BRONSON WAY N
RENTON, WA 98055
6-28-17
RJG
RBH
1 6-28-17 PRELIMINARY ZONING RJG
2 7-10-17 FINAL ZONING ENS
APPROVAL STAMP
Structural
Engineering
Architectural
www.LDCcorp.com
20210 142nd Ave NE
Woodinville, WA 98072
THE CIVIL ENGINEERING GROUP
Fx. 425.482.2893
Ph. 425.806.1869
Survey
8828
CONSTRUCTION PLAN KEYED NOTES
1. VERIFY ANTENNA MODEL, TIP HEIGHT & AZIMUTHS.
2. ANALYSIS OF TOWER & FOUNDATION SHALL BE PERFORMED BY
OTHERS & STAMPED BY A LICENSED STRUCTURAL ENGINEER.
SITE NOTES
PROPOSED POWER ROUTING.
PROPOSED VERIZON WIRELESS TEMPORARY 6'-0" HIGH
CHAIN LINK FENCE.
PROPOSED VERIZON WIRELESS TEMPORARY CHAIN LINK ACCESS GATE
WITH LOCKING MECHANISM. VZW SIGNAGE MOUNTED TO GATE.
PROPOSED VERIZON WIRELESS ANTENNA MOUNT.
PROPOSED VERIZON WIRELESS PANEL ANTENNA
(TYP 1 PER SECTOR, 3 TOTAL).
PROPOSED VERIZON WIRELESS DIPLEXER
(TYP 2 PER SECTOR, 6 TOTAL).
PROPOSED VERIZON WIRELESS MICROWAVE (1 TOTAL).
PROPOSED VERIZON WIRELESS RRUS B5 UNIT
(TYP 1 PER SECTOR, 3 TOTAL).
PROPOSED VERIZON WIRELESS RAYCAP DISTRIBUTION OVP BOX
(2 @ ANTENNAS, 2 @ EQUIPMENT, 4 TOTAL).
PROPOSED VERIZON WIRELESS CELL ON WHEELS (6'x14').
ENGINEERED BY OTHERS.
PROPOSED VERIZON WIRELESS WP METER/MAIN W/ METER
BASE AND DISCONNECT.
PROPOSED VERIZON WIRELESS EQUIPMENT CABINET.
PROPOSED VERIZON WIRELESS RRUS 32 UNIT
(TYP 1 PER SECTOR, 3 TOTAL).
PROPOSED VERIZON WIRELESS RRUS B13 UNIT
(TYP 1 PER SECTOR, 3 TOTAL).
3
4
5
6
7
9
10
11
12
13
21
25
28
29
PROPOSED VERIZON WIRELESS 30'-0"
TEMPORARY FENCED COMPOUNDPROPOSEDVERIZONWIRELESS35'-0"TEMPORARYFENCEDCOMPOUNDMEADOWSAVENEXISTING CHAIN LINK FENCE W/
PRIVACY SLATS (TO REMAIN)14'-0"PROPOSED10'-0"TEMPORARYACCESSGATE11'-0"9'-6"6'-6"
PROPOSED VERIZON
WIRELESS 14'-0"
CELL ON WHEELS
PROPOSED VERIZON
WIRELESS 6'-0"
CELL ON WHEELS
EXISTING PSE UTILITY
POLE (TO REMAIN)
4410
99 2125
PROPOSED VERIZON WIRELESS
TEMPORARY UTILITY POLE
PROPOSED TEMP
ECOLOGY BLOCK, TYP
PROPOSED VERIZON
WIRELESS TEMPORARY
GUY WIRE, TYP
12
11
6
EXISTING LANDSCAPING
(TO REMAIN)15'-0"15'-0"MW:TBD28
313
PROPOSED COW
OUTRIGGER, TYP
EXISTING PARKING LOT TOOLBOX7
29
5(BELOW)
(BELOW)
(BELOW)
1PROPOSED SOUTH ELEVATION (LOOKING NORTH)
22"x34" SCALE: 1/4" = 1'-0"11"x17" SCALE: 1/8" = 1'-0"
TIP HEIGHT OF PROPOSED
VERIZON WIRELESS ANTENNAS
45.0' AGL
FINISH GRADE
0.0' AGL
ELEVATIONS
A-3.0
CONSTRUCTION PLAN KEYED NOTES
1. VERIFY ANTENNA MODEL, TIP HEIGHT & AZIMUTHS.
2. ANALYSIS OF TOWER & FOUNDATION SHALL BE PERFORMED BY
OTHERS & STAMPED BY A LICENSED STRUCTURAL ENGINEER.
SITE NOTES
PROPOSED VERIZON WIRELESS TEMPORARY 6'-0" HIGH
CHAIN LINK FENCE.
PROPOSED VERIZON WIRELESS HYBRID FIBER CABLE TO ANTENNAS
(2 TOTAL).
PROPOSED VERIZON WIRELESS ANTENNA MOUNT.
PROPOSED VERIZON WIRELESS PANEL ANTENNA
(TYP 1 PER SECTOR, 3 TOTAL).
PROPOSED VERIZON WIRELESS DIPLEXER
(TYP 2 PER SECTOR, 6 TOTAL).
PROPOSED VERIZON WIRELESS MICROWAVE (1 TOTAL).
PROPOSED VERIZON WIRELESS RRUS B5 UNIT
(TYP 1 PER SECTOR, 3 TOTAL).
PROPOSED VERIZON WIRELESS RAYCAP DISTRIBUTION OVP BOX
(2 @ ANTENNAS, 2 @ EQUIPMENT, 4 TOTAL).
PROPOSED VERIZON WIRELESS CELL ON WHEELS (6'x14').
ENGINEERED BY OTHERS.
PROPOSED VERIZON WIRELESS WP METER/MAIN W/ METER
BASE AND DISCONNECT.
PROPOSED VERIZON WIRELESS RRUS 32 UNIT
(TYP 1 PER SECTOR, 3 TOTAL).
PROPOSED VERIZON WIRELESS RRUS B13 UNIT
(TYP 1 PER SECTOR, 3 TOTAL).
3
4
5
6
7
9
11
12
13
14
25
29
SHEET NUMBER
SUBMITTALS
DATE:
DRAWN BY:
CHECKED BY:
SITE
DESCRIPTION BYDATE
SHEET TITLE
REV
SEA CEDAR RIVER COW
1300 BRONSON WAY N
RENTON, WA 98055
6-28-17
RJG
RBH
1 6-28-17 PRELIMINARY ZONING RJG
2 7-10-17 FINAL ZONING ENS
APPROVAL STAMP
Structural
Engineering
Architectural
www.LDCcorp.com
20210 142nd Ave NE
Woodinville, WA 98072
THE CIVIL ENGINEERING GROUP
Fx. 425.482.2893
Ph. 425.806.1869
Survey
8828
PROPOSED VERIZON WIRELESS 30'-0"
TEMPORARY FENCED COMPOUND
PROPOSED VERIZON
WIRELESS 12'-4"
CELL ON WHEELS
12
6
7
PROPOSED VERIZON WIRELESS
TEMPORARY UTILITY POLE
PROPOSED TEMP
ECOLOGY BLOCK, TYP
PROPOSED VERIZON
WIRELESS TEMPORARY
GUY WIRE, TYP
EXISTING CHAIN LINK FENCE W/
PRIVACY SLATS (TO REMAIN)
EXISTING PSE UTILITY POLE
(TO REMAIN)
EXISTING LANDSCAPING
(TO REMAIN)
4
9
25
PROPOSED VERIZON WIRELESS
TEMPORARY OVERHEAD POWER
SERVICE ORIGINATING FROM
EXISTING PSE UTILITY POLE
29
5
3
13
14
RAD CENTER OF PROPOSED
VERIZON WIRELESS MICROWAVE
44.0' AGL
3
11(BEYOND)