HomeMy WebLinkAboutR-3919101-
Q
J
In
T
Z
O
Z
W
rr
O
1-
W
W
�2
V)
LI.I
<
z
L,
SEE SHEET 11
IE=509.84 A
AREA INLET A
GRATE=512.53
IE=509.73, 6"(S,NE,E)
T C13#20, TYPE 1 A7
GRATE=512.56
IE=506.81, 6"�N)
IE=504.81, 12 '(S)
(PRIVATE)
\ O2 12LF., 12" LCPE@S=60.0% (PRIVATE) A
47LF., 6" SD@S=6.21 %
CURB RAMP WIDTH 4' - 0" MIN. LANDING TO MATCH
CURB RAMP WIDTH - SEE CONTRACT PLANS
I
LANDING �
GRADE BREAK
LANDING
GRADE BREAK
CURB RAMP \
SEE CONTRACT PLANS -
SEE CONTRACT PLANS -
_ CEMENT CONCRETE
4'- 0" MIN. SIDEWALK - SEE NOTE 5
4'-0"MIN. 1
I
\
Y I
PROVIDE SMOOTH TRANSITION
CEMENT CONCRETE
TO SIDEWA-K WIDTH
SIDEWALK - SEE NOTE 5
(TYP.) SEE CONTRACT PLANS -
*
4'-0"MIN.
FLARE (TYP.)
3/8" EXPANSION
JOINT (TYP.) - SEE
318" EXPANSION
CURB RAMP STANDARD PLAN F-30.10
JOINT (TYP.) - SEE
STANDARD PLAN F-30.10
GRADE
BREAK TRANSITION TO SIDEWALK BUFFER, IF
GRADE BREAK
PRESENT, OR TO BACK OF CURB (TYP.) -
....................
•••••••••
SEE CONTRACT PLANS
.....E.•::::
v,
CURB, OR CURB
.............
AND GUTTER -
-� CURB, OR CURB
SEE NOTE 4
-
AND GUTTER -
DETECTABLE WARNING SURFACE - SEE NOTE 4
FACE OF CURB
I
SEE STANDARD PLAN F-46.10
FACE OF CURB
MEASURED PARALLEL
DEPRESSED CURB AND GUTTER -
TO CURB (TYP.)
CROSSWALK
SEE NOTE 4
I
L_
1O CONTRACTION JOINT (TYP.) - SEE STANDARD PLAN F-30.11
FOR CURB RAMP LENGTHS GREATER THAN 8'- 0" PROVIDE
PLAN VIEW CONTRACTION JOINT EQUALLY SPACED 4'- 0" MIN. DC.
TYPE PERPENDICULAR A
DETECTABLE WARNING SURFACE -
SEE STANDARD PLAN F45.10
A a eelAl rG n .AAV -% r
SLOPE TREATMENT -
SEE STANDARD PLAN F-30.10
CEMENT CONCRETE
PEDESTRIAN CURB -
SEE NOTE 4
wr.o L.,rwr
SECTION AO
CEMENT CONCRETE CURB RAMP "TYPE
PERPENDICULAR 'A" PAY LIMIT - SEE NOTE 6
DETECTABLE WARNING SURFACE -
SEE STANDARD PLAN F-45.10
3" R. TYP. DEPRESSED CURB AND GUTTER -
SEE NOTE 4
CEVENT CONCRETE CURB
AND GUTTER - SEE NOTE 4
CURB RADIUS DETAIL OB
A
NOTES
CURB RAMP WIDTH 4'- o" MIN.
1 At marked crosswalks, the connection between the curb ramp and the road -
LANDING TO MATCH CURB RAMP
WIDTH - SEE CONTRACT PLANS
way must be contained within the width of the crosswalk markings.
I
2 Where "GRADE BREAK" is called out, the entire length of the grade break
GRADE BREAK
between the two adjacent suface planes shall be Flush.
3 Do not place Gratings, Junction Boxes, Access Covers, or other appurten-
ances on any part of the Curb Ramp or Landing, or in front of the Curb
Ramp where it connects to the roadway.
SEE CONTRACT
4 See Contract Plans for the curb design specified. See Standard Plan
MIN.
PLANS - 4'- 0" MIN.
*
F-10.12 for Curb, Curb and Gutter, Depressed Curb and Gutter, and
BUFFER WIDTH -MATCH
Pedestrian Curb details.
I yr TO CURB RAMP DEPTH
(TYP.)
5 See Standard Plan F-30.10 for Cement Concrete Sidewalk Details. See
Contract Plans for width and placement of sidewalk.
m
v
6 The Bid Item "Cement Concrete Curb Ramp Type _" does not include the
adjacent Curb, Curb and Gutter, Depressed Curb and Gutter, Pedestrian
w
Curb, or Sidewalks.
/
7 The Curb Ramp length is not required to exceed 15 feet (unless shown
CEMENT CONCRETE
otherwise in the Contract Plans). When applying the 15-foot max. length,
PEDESTRIAN CURB -
the running slope of the Curb Ramp is allowed to exceed 8.3%. Use a
SEE NOTE 4
single constant slope from bottom of ramp to top of ramp to match into
DETECTABLE WARNING SURFACE -
the landing over a horizontal distance Of 15 feet. Do not Include the
SEE STANDARD PLAN F-45.10
abutting landing in the 15-foct max. measurement.
DEPRESSED CURB AND GUTTER
8 Curb Ramps and Landings sTall receive a broom finish. See Standard
CROSSWALK
Specifications 8-14.
9 Pedestrian Curb may be omitted if the ground surface at the back of the
Curb Ramp and/or Landing will be at the same elevation as the Curb
Ramp or Landing and there will not be material to retain.
PLAN VIEW
TYPE PERPENDICULAR B
(SHOWN WITH BUFFER)
GRADE BREAK
COUNTER SLOPE -
5.0%MAX
- TOP OF ROADWAY
DEPRESSED CURB AND GUTTER -
SEE STANDARD PLAN F-10.12
ISOMETRIC VIEW
TYPE PERPENDICULAR A PAY LIMIT
CEMENT CONCRETE CURB RAMP "TYPE
PERPENDICULAR "B" PAY LIMIT - SEE NOTE 6
LEGEND
SLOPE IN EITHER DIRECTION
*
1.5 OR FLATTER RECOMMENDED FOR
DESIGN/FORMWORK (2% MAX.)
* *
7.5% OR FLATTER RECOMMENDED FOR
DESIGN/FORMWORK (8.3% MAX.)
* * *
9.5% OR FLATTER RECOMMENDED FOR
DESIGN/FORMWORK (10% MAX.)
ISOMETRIC VIEW
TYPE PERPENDICULAR B PAY LIMIT
-0p WAS#/28680 t�
GI S TeV�oGN��cv
slONAL E0
Zeller, Scott
Jun 24 2016 7:20 AM
PERPENDICULAR
CURB RAMP
STANDARD PLAN F-40.15-03
SHEET 1 OF 1 SHEET
APPROVED FOR PUBLICATION
Carp-W,,, mR
eQ/YfIC/ltV'L. �1# Jun 292e162. 2R I'M
o,s
_ STATEDESIGN ENGINEER
Washington State Department of Transportation
GRAPHIC SCALE
0 5 10 20
I inch = 10 feet
6" CONCRETE APRON
W/ 4 REMOVEABLE BOLLARDS
PER CITY DWG. NAME H021 ,
SEE SHEET 13
I I I CONSTRUCTION RECORD DRAWING
THIS CONSTRUCTION RECORD DRAWING IS A COPY OF A CAD FILE PREPARED
BY OFFE ENGINEERS, PLLC AND HAS BEEN EDITED TO REFLECT FIELD VERIFIED
AAS-BUILT REVISION 12-1 1-2018 INVERT AND RIM ELEVATIONS OF THE STORM, SANITARY AND WATER SYSTEM. FIELD
VERIFIED INVERT AND RIM ELEVATIONS WERE PROVIDED BY PACIFIC COAST SURVEYS, INC.,
ON DECEMBER 10, 2018. THE ON -SITE PRIVATE STORM DRAINAGE AND PUBLIC/PRIVATE
7 AS -BUILT DLO 12/2018 WATER AND SEWER SYSTEMS WERE INSTALLED IN ACCORDANCE WITH THE APPROVED
tiZ, L , pay, 6 REVISED ROCKERY TO SAVE TREE DLO 9/201 s PLANS AND THE DOCUMENTED FIELD REVISIONS AND FUNCTION AS INTENDED.
OFFS ENGINEERS ��°FeWASy,N�To 5 REVISED VAULT PER CITY COMMENTS DLO 6/2018
SURVEYED:SCALE:
SURVEYING SCALE. HORI20NTALLNAVD 19
�a ya 4 REVISED PER CITY COMMENTS DLO 2/2018 CITY OF
13932 SOUTHEAST 159TH PLACE Ao _ DESIGNED:
3 REVISED PER CITY COMMENTS DLO 1/2018 D.L. OFFE, P.E. � RENTON
RENTON, WASHINGTON 98058 a 2 REVISED PER CITY COMMENTS DLO 9/2017 DRAWN: OFFE, P.E. •
PHONE: 425-260-3412 27460 ONE INCH
�'o�?'F� �o0 1 REVISED PER CITY COMMENTS DLO 2/2017 CHECKED: AT FULL SCALE DATUM
CONTACT: DARRELL OFFE, P.E. FSS�ONALI IF NOT 0 APPROVED: SCALE ACCORDINGLY
Planning/Building/Public Works Dept.
12/12/2018 N0. REVISION BY DATE APPR
remamble watertight
nupling or flange
2' min.
In
plate waded to elbow
with orifice as, specified
ELBOW
RESTRICTOR
DETAIL
IBOIIBiTRIC
elevation per plans
r min under
pa+emem 16" nez.
e" min.
elbow restrirAor, see detail
pipe supports
see Noe 6-
-FI
D 1
invrxt and I. Ann
por plans
welded matrlctor plant
with orifice diameter se,
specified (not needed If
for spill central only)
WIMMON AA
2'minclearance
.a
podion of f p-T
Indudlnp dhows
A
NOTES:
1. Use a mimimum of a 54" diameter type 2
catch basin.
2. Outlet Capacdy: 100-Year developed
peak flow.
3. Metal Parts: Corrosion resistant.
Non -Galvanized parts perferred.
esow reahictp
see detail
Galvanized pipe parts to have asphalt
treatment 1.
4. Frame and ladder or steps offset so:
A. Cleanout gate Is visible from top.
B. Climb -down space is dearof riser and
cleancut gate.
C. Frame is clear of curb.
5. II metal ou0el pipe connects to cement
concrete pipe: outlet pipe to have smooth
O.D. equal to concrete pipe I.D. less ?.
6. Provide at least one 3" X .09Cgage support bracket
ancharad to concmtewall.
(maximum T-O'vertloal spacing)
7. Locate elbow restrictor(s) as necessary to provide minimum
clearance asshown.
8. Locate additional ladder rungs in structures used as
access to tanks and .cults to
allow access Wien catch basin Is filled with water.
&solid rover
marked "DRAIN" with locking belts
see note 3
vertical bar
grate for
secondary inlet
steps or
sheer get. will, control
rod for deenavdrain
(rod bent as regwred
for vertical aliglmwt
with cover)
radtltlonal
ladder rungs
(in seta) a allow access
to tanks or vwh when
catch Ia filled An water
PWI YIEA
PUBLIC WORKS FLOW RESTRICTOR STD. PLAN - 287.00
aDEPARTMENT OIL POLLUTION CONTROL
TEE MARCH 2O08
SECTION 42
PIPES, OUTFALLS, AND PLJMPS
FIGURE 4.2.2.A PH'E/CULVERT DISCHARGE PROTECTION
channel
Required Dimensions
qC_K_�_2A"
_ ' ,, 8' for rock lining
12' for rip rap
see Table 4.2.2.A.
C
0
a
O
q
00
PLAN
NTS
place rock 1' above crown
both sides of channel for "A" < 8'
one side of channel for "A" > 8' -
ill T min.
discharge pipe
k�7
filter
fabric liner - V or 2' rock thickness
under rock see table 4.4.1.A
SECTION A -A
NTS
1/9/2009
2009 Surface Water Design Manual
4-32
frame
�o
n�n
(4'
min.)
Y
c
%9
w
0
30'min
a
o
2'
y
Y
O
O
O
O
RECORD DRAWINGS R-391910
IN COMPLIANCE WITH CITY OF RENTON STANDARDS
RENTON 14 PLAT
KENDALL HOMES, INC.
TRACT A LAYOUT PLAN
6201 NE 4th STREET
10
a
J
DATE:
12/12/2018 Tf
FlELDBOOK: L
PAGE: O
DRAWING N0:
Z
SHEET: 10 OF:2 W
Q