HomeMy WebLinkAboutW-397105Z
0
!�
V
z
ry
Q
L
STA.=50+00.00, ALLEY C & D—/
END ROAD IMPROVEMENTS
1" WATER SERVICE AND METER PER I
COR STANDARD PLAN 320.1 (TYP.)
28
28
27
27
26
26
25
25
A PORTION OF THE NE 1/4 OF SEC 13, TWP 23 N., RGE 4 E, W.M., KING COUNTY, WASHINGTON n
ROAD A
SEE SHEET RD-01
ROAD A
SEE SHEET WA-01
5
N N N N N N co r- rM r- c0 c0 c0 c0 c0 c0 c0 CID
�M COS �� ^ O� OM Ln In04 O00O� 0 �M N � N ��
00 � OO 0 � N �
17 ',00 00� O � O O� (3(.0) (3)� O CD r7 r7 N I
O(D (D(D �� O� OOO(0 O(0 O� O� �� ^ �^ r- CID �� �� r-
N N(D N N (D (D N (D N N N CID N N CIDN N CID N (0N N (0N N CIDN� N N� N N N N N N N N N N N N CID N N
CID N
N N
5
CL INT'X
STA 51 +63.35, ALLEY C & D
= STA. 7+33.15, ROAD A
ELEV=266.70
0
EX. GROUND
5
� J
PROPOSED GRADE @ — 3' MIN 3.00%
COVER
—1.00% / 2-00% 2.0090
0
Li
PROPOSED STORM
I
PROPOSED SEWER
0
50+00
Call 2 Working Days Before You Dig
811
Utilities Underground Location Center
(ID,MT,ND,OR,WA)
2-3-2020
51 +00
CERTIFICATION FOR AS—BUILTS ONLY.
SEE APPROVED PLANS BY ESM CONSULTING ENGINEERS
DATED JANUARY 30, 2018, JOB #1938-001 —01 6.
AS -BUILT
0 FIRST SUBMITTAL
1 SECOND SUBMITTAL
2 THIRD SUBMITTAL
NO. I REVISION
52+00
ESM 08/30/17 SURVEYED:
ESM 11/15/17 DESIGNED:
ESM 01/03/18 PDG
DRAWN:
CHECKED:
BY I DATE I A P P R I APPROVED
53+00
SCALE:
1 "=20'
ONE INCH
AT FULL SCALE
IF NOT ONE INCH
SCALE ACCORDINGLY
VERTICAL: NAVD 1988
HORIZONTAL: NAD 1983/1991
DATU M
O� \
STA.=53+38.29, 5.00' LT.
1-8" END CAP (MJ)
W/2" BLOW OFFF ASS'Y V ��
1-GONG. BLO CKI NG
STA.=53+40.79, ALLEY C & D
END ROAD IMPROVEMENTS
285
275
270
265
260
255
250
53+60
•
CITY OF
RENTON
Planning/Building/Public Works Dept.
SCALE: 1 "=20' HORIZ.
1 "=5' VERT.
CONTOUR INTERVAL = 2'
NONNI
20 10 0 20 40
1. A 6" THICK ETHAFOAM PAD TO BE
PLACED IN BETWEEN PIPES WHERE
MINIMUM PIPE SEPARATION OF 18"
CANNOT BE ACHIEVED.
2. AN INDIVIDUAL 1" PRESSURE
REDUCING VALVE (PRV) IS REQUIRED
DOWNSTREAM OF EACH DOMESTIC
WATER METER BECAUSE THE STATIC
WATER PRESSURE IS OVER 80 PSI
PER COR STANDARD PLAN 340.5.
3. DCVA REQUIRED BEHIND EACH METER
IF BUILDINGS ARE 3—STORY (TYPICAL
FOR ALL METERS.)
IN COMPLIANCE WITH CITY OF RENTON STANDARDS
EARLINGTON TOWNHOMES
WATER PLAN & PROFILE
UTILITY PERMIT #
01/23/18
FIELDBOOK:
PAGE:
DRAWING NO:
WA-03
SHEET: OF:
42 55
0
0
0
0
0
0
0
a_
W-397105