Loading...
HomeMy WebLinkAboutR-4003070 0 It I 6 I w C� I) CU LLI r•� O O I 0 U) I- Ld Ld U) 0 0 a U i Ld U Q ry ry Ld I- Ld V)n z �LO n fn Don o�ry 0-0)ry L.i LLI LLJ :2 �:2Q QFz z Lq LLJ J 0 N =a- z JOINTS IN FILTER FABRIC SHALL BE SPLICED AT POSTS. USE STAPLES, WIRE RINGS, OR FCII IIVAI FNT TO ATTACH FARRIr. TO Pl1CTC 6' MAX. POST SPACING MAY BE INCREASED TO 8' IF WIRE BACKING IS USED NOTES 1. CONDITION OF USE 2"x2" BY 14 Ga. WIRE OR EQUIVALENT, IF STANDARD STRENGTH FABRIC USED FILTER FABRIC so _� MINIMUM 4"x4" TRENCH Z N BACKFILL TRENCH WITH u NATIVE SOIL 2"x4" WOOD POSTS, STEEL FENCE POSTS, REBAR, OR EQUIVALENT 1.1. SILT FENCE MAY BE USED DOWNSLOPE OF ALL DISTURBED AREAS. 1.2. SILT FENCE IS NOT INTENDED TO TREAT CONCENTRATED FLOWS, NOR IS INTENDED TO TREAT SUBSTANTIAL AMOUNTS OF OVERLAND FLOW. ANY CONCENTRATED FLOW MOST BE CONVEYED THROUGH THE DRAINAGE SYSTEM TO A SEDIMENT TRAP OR POND. 2. DESIGN AND INSTALLATION SPECIFICATIONS 2.1. THE GEOTEXTILE USED MOST MET THE STANDARD LISTED BELLOW. A COPY OF THE MANUFACTURER'S FABRIC SPECIFICATIONS MOST BE AVAILABLE ON SITE. 30.100SIEVE SIZE 0.60-0.15MM FOR SILT FILM AOS (ASTM D4751) 50-100SIEVE SIZE (0.30-0.15MM) FOR OTHER FABRICS WATER PERMITTIVITY ASTM D491 0.02SEC`1 MINIMUM 180 LBS. MIN. FOR EXTRA STRENGH FABRIC GRAB TENSILE STRENCHT (ASTM D4632) 10D LBS. MIN. FOR STANDARD STRENGHT FABRIC GRAB TENSILE ELONGATION ASTM D4632 30%MAX. ULTRAVIOLATE RESISTANCE(ASTM D4355) 70%MIN. 2.2. STANDARD STRENGTH FABRIC REQUIRES WIRE BACKING TO INCREASE THE STRENGTH OF THE FENCE. WIRE BACKING OR CLOSER POST SPACING MAY BE REQUIRED FOR EXTRA STRENGTH FABRIC IF FIELD PERFORMANCE WARRANTS A STRONGER FENCE. 2.3. WHERE THE FENCE IS INSTALLED, THE SLOPE SHALL NOT BE STEEPER THAN 2HAV 2.4. IF A TYPICAL SILT FENCE IS USED, THE STANDARD 4X4 TRENCH MAY NOT BE REDUCED AS LONG AS THE BOTTOM 8 INCHES OF THE SILT FENCE IS WELL BURIED AND SECURE IN A TRENCH THAT STABILIZES THE FENCE AND DOES NOT ALLOW WATER TO BYPASS OR UNDERMINE THE SILT FENCE. 3. MAINTENANCE STANDARDS 3.1. ANY DAMAGE SHALL BE REPAIR IMMEDIATELY. 3.2. IF CONCENTRATED FLOES ARE EVIDENT UPHILL OD THE FENCE, THEY MUST BE INTERCEPTED AND CONVEYED TO A SEDIMENT TRAP OR POND. 3.3. IT IS IMPORTANT TO CHECK THE UPHILL SIDE OF THE FENCE FOR SIGNS OF THE FENCE CLOGGING AND ACTING AS A BARRIER TO FLOW AND THEN CAUSING CHANNELIZATION OF FLOWS PARALLEL TO THE FENCE. IF THIS OCCURS, REPLACE THE FENCE OR REMOVED THE TRAP SEDIMENT. 3.4. SEDIMENT MOST BE REMOVED WHEN SEDIMENT IS 6 INCHES HIGH. 3.5. IF THE FILTER FABRIC (GEOTEXTILE) HAS DETERIORATED DUE TO ULTRAVIOLET BREAKDOWN, IT SHALL BE REPLACED. G� PUBLIC WORKS SILT FENCE STD. PLAN - 214.00 ��NTO DEPARTMENT I�1� 11zC11 '( 08 CONSTRUCTION RECORD DRAWING THIS CONSTRUCTION RECORD DRAWING IS A COPY OF THE APPROVED CONSTRUCTION DRAWING PREPARED BY OSBORN CONSULTING INC. AND HAS BEEN EDITED USING INFORMATION PROVIDED BY OAK HILLS CONSTRUCTION, LLC TO REFLECT ASBUILT CONDITIONS INSTALL E IS A ROAE PER CITY NOTES RIVEWAYS SHALL BE PAVED TO THE EDGE ,F R-O-W PRIOR TO INSTALLATION OF THE ONSTRUCTION ENTRANCE TO AVOID AMAGING OF THE ROADWAY F IS RECOMMENDED THAT THE !NTRANCE BE CROWNED SO THAT ;UNOFF DRAINS OFF THE PAD PROVIDE FULL WIDTH OF INGRESS/EGRESS AREA 1. CONDITION OF USE 1.1. CONSTRUCTION ENTRANCE SHALL BE STABILIZED WHEREVER TRAFFIC WILL BE LEAVING A CONSTRUCTION SITE AND TRAVELING ON PAVED ROADS OR OTHER PAVED AREAS WITHIN 1,000 FEET OF THE SITE. GRAB TENSILE STREBNGTH (ASTM D4751) 200 PSI MIN. GRAB TENSILE ELONGATION (ASTM D4632) 30% MAX. MULLEN BURST STRENGTH ASTMD3786-80A 400PSI MIN. AOS (ASTM D4751) 20-45 (U.S. STANDARD SIEVE SIZE) 2. DESIGN AND INSTALLATION SPECIFICATIONS 2.1. HOG FUEL (WOOD BASED MULCH) MAY BE SUBSTITUTED FOR OR COMBINED WITH QUARRY SPALLS IN ARES THAT WILL BOT BE USED FOR PERMANENT ROADS. HOG FUEL IS NOT RECOMMENDED FOR ENTRANCE STABILIZATION IN URBAN AREAS. THE INSPECTOR MAY AT ANY TIME REQUIRE THE USE OF QUARRY SPALLS IF THE HOG FUEL IS NOT PREVENTING SEDIMENT FROM BEING TRACKED ONTO PAVEMENT OR IF THE HOG FUEL IS BEING CARRIED ONTO PAVEMENT. 2.2. FENCING SHALL BE INSTALLED AS NECESSARY TO RESTRICT TRAFFIC TO THE CONSTRUCTION ENTRANCE. 2.3. WHENEVER POSSIBLE, THE ENTRANCE SHALL BE CONSTRUCTED ON A FIRM, COMPACTED SUBGRADE. THIS CAN SUBSTANTIALLY INCREASE THE EFFECTIVENESS OF THE PAD AND REDUCE THE NEED FOR MAINTENANCE. 3. MAINTENANCE STANDARDS 3.1. QUARRY SPALLS SHALL BE ADDED IF THE PAD IS NO LONGER IN ACCORDANCE WITH THE SPECIFICATIONS. 3.2. IF THE ENTRANCE IS NOT PREVENTING SEDIMENT BEING TRACKED ONTO PAVEMENT, THEN ALTERNATIVE MEASURES TO KEEP THE STREETS FREE OF SEDIMENT SHALL BE USED. THIS MAY INCLUDE STREET SWEEPING, AN INCREASE IN THE DIMENSIONS OF THE ENTRANCE, OR THE INSTALLATION OF THE WHEEL WASH. IF WASHING IS USED, IT SHALL BE DONE ON AN AREA COVERED WITH CRUSHED ROCK, AND WASHED WATER SHALL DRAIN TO A SEDIMENT TRAP OR POND. 3.3. ANY SEDIMENT THAT IS TRACKED ONTO PAVEMENT SHALL BE REMOVED IMMEDIATELY BY SWEEPING. THE SEDIMENT COLLECTED BY SWEEPING SHALL BE REMOVED OR STABILIZED ON SITE. THE PAVEMENT SHALL NOT BE CLEANED BY WASHING DOWN THE STREET, EXCEPT WHEN SWEEPING IS INEFFECTIVE AND THERE IS A THREAT TO PUBLIC SAFETY. IF IT NECESSARY TO WASH THE STREETS, A SMALL SUMP MUST BE CONDUCTED. THE SEDIMENT WOULD THEN BE WASHED INTO THE SUMP WHERE IT CAN BE CONTROLLED AND DISCHARGED APPROPRIATELY. 3.4. ANY QUARRY SPALLS THAT ARE LOOSENED FROM THE PAD AND END UP ON THE ROADWAY SHALL BE REMOVED IMMEDIATELY. 3.5. IF VEHICLES ARE ENTERING OR EXITING THE SITES AT POINTS OTHER THAN THE CONSTRUCTION ENTRANCE(S), FENCING SHALL BE INSTALLED TO CONTROL TRAFFIC - STD. STD. PLAN - 215.10 PUBLIC WORKS STABILIZED DEPARTMENT CONSTRUCTION ENTRANCE 1'I-11�C11 008 5" MAX. - N DRAINAGE GRATE TRIM _ xx m GRATEFRAME z 3 V A.a a D SEDIMENT AND DEBRIS a 4 OVERFLOW BYPASS v o BELOW INLET GRATE DEVICE FILTERED WATER POLYETHYLENE CAP \ \\i A 0 PROVIDE ADEQUATE STRAPPING > o 77 PERFORATED POLYETHYLENE DRAINAGE TUBING, DIAMETER CORRUGATED SECTION VIEW MIN. 2" LARGER THANJWATERTIGHT METAL RISER DEWATERING ORIFICE FLOAT ACTIVATED PUMP PER TUBING SHALL COMPLY CONTRACTOR WITH ASTM F667 AND 3.5' MIN. AASHTO M294. DRAINAGE GRATE DEWATERING ORIFICE, SCHEDULE - RECTANGULAR GRATE SHOWN RETRIEVAL SYSTEM (TYP.) L COUPLING TACK WELD 40 STEEL STUB MIN. DIAMETER AS PER CALCULATIONS 6" MIN. FORCE MAIN TO APPROVE DISCHARGE LOCATION 18' MIN. ALTERNATIVELY, METAL STAKES AND WIRE MAY BE USED TO CONCRETE BASE PREVENT FLOTATION BELOW INLET GRATE DEVICE OVERFLOW BYPASS (TYP.) ­111-- 2X RISER DIA. MIN. ----- ft_ ISOMETRIC VIEW NOTES 1. Size the Below Inlet Grate Device (BIGD) for the storm water structure it will service. 2. The BIGD shall have a built-in high -flow relief system (overflow bypass). 3. The retrieval system must allow removal of the BIGD without spilling the collected material. 4. Perform maintenance in accordance with Standard Specification 8-01.3(15). O~�Y PUBLIC WORKS SEDIMENT POND STD. PLAN - 216.10 Gti�Y ��, PUBLIC WORKS CATCH BASIN FILTER STD. PLAN - 216.30 DEPARTMENT %$ DEPARTMENT RISER DETAIL -1aR�11 2008 �NTp MARCH 2O08 Know what's below. APPROVED BY: DATE: Cal before you dig. APPROVED BY: DATE: APPROVED BY: DATE: APPROVED BY: DATE: R-400307