Loading...
HomeMy WebLinkAboutR-398827• r #�i�.. w r HIDDEN) AND •i ILI PVC MAINLINE PIPE PVC SCH 40 TEE ,. ELL PVC SCH i MALE ADAPTER' 1-INCH MIMMUIA DEPTH 1 3/4-INCH WASHED GRAVEL PVC LATERAL PIPE ' REMOTE CONTROL ®FINISH GRADE/ 1' OF QUICK -COUPLING VA4VE AM COVER 0.p VALVE BOX V DEPTH OF WASHEDCvRAVEL BRICK (I OF PVC SCH 80,NIPPLE (LENGTH AS REQUIRED) r/,• ttsumn�tttctttt'�l�j� :+•0 wiwr■ l STREET K w :t NIPPLE tutumattitsst i► r' # �j 407EE OR ELL rol-m-pVC MAINLINE PIPE J -PVC SCH 1 ELL ---�-- -2" x 2" PRESSURE TREATED NOTE. WOOD STAKE W/ L FURNISH FITTINGS AND PIPING STAINLESS STEEL GEAR NOMINALLY SIZED IDENTICAL TO CLAMPS OR EQUIVALENT NOMINAL QUICK COUPLING VALVE INLET SIZE. SUPPORT SYSTEM TYP. QUICK COUPLER 777 SCAJ Ps N.T.S. RADE/TOF OF MULCH 'RAY SPRINKLER MALE NPT x .490 INCH CPE,12-INCH LENGTH. W TEE OR ELL MALE NPT x .490 INCH RAL PIPE TYP. POP UPS SPRINKLER HEAD SECTION VIEW MAINLINE, LATERAL, MAINLINE LATERAL AND MIRTH& IN PIPE PIPE THE SAME TRENCH WIRING IN CONDUIT P� WIRE W/0 CONDUIT RUN WIRMI * BENEATH ALL SOLVENT WELD TIE A 24-INCH LOOP AND BESIDE MAINLINE. PLASTIC PIPING TO ALL WIRING AT CHANGES TAPE AND BUNDLE AT BE SNAKED IN OF DIRECTION OF 30° 5-FOOT INTERVALS. TRENCH AS SHOWN. OR &BEATER. UNTIE AFTER ALL CONNECTIONS NOTES: HAVE BEEN MADE. 1. SLEEVE BELOW ALL HARbSCAPE ELEMENTS WITH TYPE 3034 PVC TWICE THE DIAMETER OF THE PIPE OR WIRE BUNDLE WITHIN. 2. FOR PIPE AND WIRE BURIAL DEPTHS SEE SPECIFICATIONS. TYP. PIPE AND WIRING TRENCH 8Cr4�.Es N.T/� SCAl s N.T.S. TO METER FINISH GRADE/ I Or OF MULCH VALVE BOX WITH COVER PVC SCH 40 TEE PVC LATERAL PIPE FILTERED DRAIN VALVE BRICK (1 OF 2) 6-INCH MINIMUM DEPTH OF 3/4'INC44 WASHED GRAVEL DRAIN VALVE St:AL•Es Lei•i -Peowm i NOZZLE AS SHOWN ON STAINLESS STEEL CLAD OR GALV. WIRE TWIST 36" SCH 80.1 FINISH LATERAL PIPE SWING PIPE CONNECTION SIMILAR TO TYPICAL POP-UP SPRINKLER FIXED RISER DETAIL • W-A-m N.T.S. GALV. 12" MIN. SECTION ADAPTER 419 3" MAX _ r GALv. a~ 00 r CAP ('TYPICAL) 18" MIN. 24" TO FINISH GRADE VING i 24" ORIENT SHRUB FOR BEST IF PLANT T5 BALLED AND APPEARANCE REMOVE ALL B{,�,APED THEN REMOVE BROKEN, DEAD STEMS DO NOT DISFIGURE PLANT TREATED BURLAP. FOLD, BACK NATURAL BURLAP OFF TOP OF ROOTBALL• CLEARANCE PROVIDE SLIGHT FINISH GRADE 4" MIN. {3.EAR WATERING SAUCER '-"�-"•-PAVING AROUND 5 GALLON AND n DITCH LARGE'R.PLANTS 2" HT. TYP, MULCH (Ur DEPTH IF • ,M i i t :� 1 1 s s ! N • • f • e • • e • • • • • • • • 1!, 0.28 f • • : 0.01 ! t!�! 094 1 f ! ! i M ! ! • f / 0.00 0.01 ;• 1 • ! 0.08 • • 1 1 • t 2.36 ! 1.44 1 0.36 0.90 0.12 1 0.68 0.06 0.44 0.02 .83 6: ! ! t.82 • !' 10053• ! • 2.23 202067 1.26 022 • •. Oil 11 061 0.04 • ! 0.34 1.24 t 18 1 0.06 ! :: f :f ! • i ! • r' va xa -s 4346 1.83 i • . i 36 t. f 1 �5{ } i t • .26 IN 3.03 34 09 ��30 -1 i .43 .CNN _ 'Y- Y • _ @ -••n �y�.• fYy'•'{�yi - 5'� 3.86 1.46 , i Z.65 056 s•a�; a= sz.-s'��-•w <.,�a f #rs e - 9:y ` s`'®4 � �g3.3 :�+�r • ♦ T g 3.08 17 075 fi �r • .96 /�G��s�� y -.a - .. " n}.a j'' '.., �i. ✓;.fz %,y siyi.s.�'F ""�F .x�t s ,:'�.- � _ _ - v-�%` _r_:.,�'S"� r K?.n 4.. , lr.: ,aS z >... z.,. C.c r �., .. , r•.,..,.. ,��Nfy� c` a., ..-. �:...,. .,471-.y / 53.t $t+ Yd`,,..5.. .) .......ss< A i SIZE 3/4"I,- OD 1.050 1.315 1.650 1.900 ID .930 1.189 1.502 1.720 IRRIGATION FLOW CHART SCALE= WE& 1. 1° ROUND WA5HED GRAVEL BY 6" DEEP ON BOTTOM OF BOX UICK COUPLER 2. ENCLOSE 2" & SMALLER D.C.V.A. IN TWO METER BOXES STACKED ON Dom' TOP OF EACH OTHER OR, OVER SIZED. MUST HAVE REMOVABLE COVER. PVC 3. MAXIMUM OF 3" DISTANCE BETWEEN UNDERSIDE OF LID AND HIGHEST POINT OF DEVICE. -----«�- 4. MUST INCLUDE (4) RESILIENT SEATED TEST -COCKS WITH PLUGS INSTALLED. FLOW 5. THE D.C.V.A. MUST INCLUDE (2) RESILIENT SEATED SHUTOFF VALVES. DOUBLE CHECK 6. Y-PATTERN D.C.V.A. SHOULD BE INSTALLED ON SIDE. ASSEMBLY 7. WHEN TEST -COCKS ARE FACING SIDEWAYS THERE MUST BE A 6" MINIMUM CLEARANCE BETWEEN THEM AND SIDE OF BOX. 8. MINIMUM OF 12" BETWEEN LOWEST POINT OF DEVICE AND DRAIN ROCK 9. PROVIDE SUPPORT FOR 2" DEVICES. -- - NOTES: 1. INSTALL ACCORDING TO MANUFACTURER'S SPECIFICATIONS. 2. ALL INSTALLATION MUST MEET MINIMUM STANDARDS OF UNIFORM PLUMBING CODE do WATER DISTRICT. 3. ASSEMBLY REQUIRES TESTING AND CERTIFICATION PRIOR TO USE AND ANNUALLY THEREAFTER. FOR INFORMATION CONTACT WATER QUALITY TECHNICIAN. 4. APPLY AND PAY FOR ALL REQUIRED PERMITS PLAN POINT OF CONNECTION =1X(tN�2 C4481< A 5EMELT K_ - 7 8C 4LN N•TlBr. SLEEVES a f 2'DEPTH PREPARED TOP-SCIL DIAMETER OF ROOTBALL TYPICAL A SHRUB r * ANTI a" EXXTA UZ r • ! HEM -FIR STAKE� AL EOM TO TREE WITH GALVANIZED WIRE ENCASED i IN REINFORCED1DULLGREEN WBRER J� HOSE AT POINT OF PLAW COWAa.+r ¢" TOP Of STAKE TO POINT SH GRADE Y _..wIM. 'FROM SIDE / �•w ROOTBALL i PREPARED SOIL BACKPILL. EXIST" SUBGRADE CONIFEROUS, • TREE -PLANTING SCALRsXTA SPAC"SPACING t ! I .! 10.4(r ii .738 +' .52 20.8(r . ! 30.W `` SEE GROUNbCOVER PLANT KEY FOR SPACING �A`. THIS CHARTIS TO BE USED . DETERMINE N"BEP. OF GROLWXOVEFt PLANTS REQUIRED IN A GIVEN A\*IA 0 0- LOCATION PLANT SPACrNG_ CHART FOR 0 PLANTS ARE SPACED EQUIDISTANT FROM OTHER, AS IN ALL MASSED r • PLANT SPACING CHART WALfisttTA Z" TREE SPECIMEN CENTRAL 2.375 LEADER SHALL NOT BE CUT 2.149 1/2" DIA. BLACK FLEX GARDEN HOSE WITH 16 ga. TIE WIRE. SECURE THRU"X"BRACE lx3 HEM FIR 24 HEM FIR STAKES JOP'iIONAI METHOD FOR 5A TERING EYER6RN V TREE iNq.UDEB 0 3 EQ.SPACEb GUV WIRES AR 0 AROUND WJ rx2"x24" CEDAR STAKES TREE TREE WELL. AROUND TREE 4" DEEP - MIN. 4$" DIAMETER 1 PREPARED SOIL BACICFILL REMOVE TOP 1/3 OF BURLAP 1. WIDTH OF PLANTING PIT SHALL. BE 24" MIN. 2 TIMES LARGER THAN ROOT BALL. 2. PRE -STAIN ALL WOOD. STAIN ALL FIELD CUTS TYP -ICAL DECD U+t3US TREE PtANTIN SGAL. mTs R-398827