HomeMy WebLinkAboutR-398827•
r #�i�.. w r
HIDDEN) AND •i
ILI
PVC MAINLINE PIPE
PVC SCH 40 TEE
,. ELL
PVC SCH i MALE ADAPTER'
1-INCH MIMMUIA DEPTH 1
3/4-INCH WASHED GRAVEL
PVC LATERAL PIPE
' REMOTE CONTROL
®FINISH GRADE/
1' OF
QUICK -COUPLING VA4VE
AM COVER
0.p VALVE BOX V
DEPTH OF
WASHEDCvRAVEL
BRICK (I OF
PVC SCH 80,NIPPLE
(LENGTH AS REQUIRED)
r/,• ttsumn�tttctttt'�l�j�
:+•0 wiwr■ l STREET K
w
:t NIPPLE
tutumattitsst i► r' #
�j 407EE OR ELL
rol-m-pVC MAINLINE PIPE
J -PVC SCH 1 ELL
---�-- -2" x 2" PRESSURE TREATED
NOTE. WOOD STAKE W/
L FURNISH FITTINGS AND PIPING STAINLESS STEEL GEAR
NOMINALLY SIZED IDENTICAL TO CLAMPS OR EQUIVALENT
NOMINAL QUICK COUPLING VALVE INLET SIZE. SUPPORT SYSTEM
TYP. QUICK COUPLER
777 SCAJ Ps N.T.S.
RADE/TOF OF MULCH
'RAY SPRINKLER
MALE NPT x .490 INCH
CPE,12-INCH LENGTH.
W TEE OR ELL
MALE NPT x .490 INCH
RAL PIPE
TYP. POP UPS SPRINKLER HEAD
SECTION VIEW
MAINLINE, LATERAL, MAINLINE LATERAL
AND MIRTH& IN PIPE PIPE
THE SAME TRENCH
WIRING IN
CONDUIT
P� WIRE W/0 CONDUIT
RUN WIRMI * BENEATH ALL SOLVENT WELD TIE A 24-INCH LOOP AND BESIDE MAINLINE. PLASTIC PIPING TO ALL WIRING AT CHANGES
TAPE AND BUNDLE AT BE SNAKED IN OF DIRECTION OF 30°
5-FOOT INTERVALS. TRENCH AS SHOWN. OR &BEATER. UNTIE
AFTER ALL CONNECTIONS
NOTES: HAVE BEEN MADE.
1. SLEEVE BELOW ALL HARbSCAPE ELEMENTS WITH TYPE 3034 PVC
TWICE THE DIAMETER OF THE PIPE OR WIRE BUNDLE WITHIN.
2. FOR PIPE AND WIRE BURIAL DEPTHS SEE SPECIFICATIONS.
TYP. PIPE AND WIRING TRENCH
8Cr4�.Es N.T/�
SCAl s N.T.S. TO METER
FINISH GRADE/ I Or OF MULCH
VALVE BOX WITH COVER
PVC SCH 40 TEE
PVC LATERAL PIPE
FILTERED DRAIN VALVE
BRICK (1 OF 2)
6-INCH MINIMUM DEPTH OF
3/4'INC44 WASHED GRAVEL
DRAIN VALVE
St:AL•Es Lei•i -Peowm i
NOZZLE AS SHOWN ON
STAINLESS STEEL CLAD
OR GALV. WIRE TWIST
36" SCH 80.1
FINISH
LATERAL PIPE
SWING PIPE CONNECTION
SIMILAR TO TYPICAL
POP-UP SPRINKLER
FIXED RISER DETAIL
• W-A-m N.T.S.
GALV.
12" MIN.
SECTION
ADAPTER
419
3" MAX
_ r GALv.
a~
00
r
CAP ('TYPICAL)
18" MIN.
24" TO
FINISH GRADE
VING
i
24"
ORIENT SHRUB FOR BEST IF PLANT T5 BALLED AND
APPEARANCE REMOVE ALL B{,�,APED THEN REMOVE
BROKEN, DEAD STEMS
DO NOT DISFIGURE PLANT TREATED BURLAP. FOLD,
BACK NATURAL BURLAP OFF
TOP OF ROOTBALL•
CLEARANCE PROVIDE SLIGHT FINISH GRADE
4" MIN. {3.EAR WATERING SAUCER
'-"�-"•-PAVING AROUND 5 GALLON AND
n DITCH LARGE'R.PLANTS 2" HT. TYP, MULCH (Ur DEPTH IF
• ,M i i t :� 1 1 s
s
! N • •
f •
e • •
e • •
•
•
•
•
•
•
1!,
0.28
f •
• :
0.01
!
t!�!
094
1
f
! !
i
M !
!
• f
/
0.00
0.01
;•
1
•
!
0.08
•
• 1
1
• t
2.36
!
1.44
1 0.36
0.90
0.12 1
0.68
0.06
0.44
0.02
.83
6:
!
!
t.82
• !'
10053•
!
•
2.23 202067
1.26
022
• •.
Oil 11
061
0.04
•
!
0.34
1.24
t 18
1
0.06
!
::
f
:f
!
•
i
! •
r'
va xa -s 4346 1.83 i •
.
i 36
t.
f 1
�5{
}
i
t
• .26
IN
3.03
34
09
��30
-1
i .43
.CNN _ 'Y- Y • _ @
-••n �y�.• fYy'•'{�yi - 5'�
3.86
1.46
,
i
Z.65
056
s•a�; a= sz.-s'��-•w <.,�a f #rs e - 9:y ` s`'®4 � �g3.3 :�+�r • ♦
T g
3.08
17
075
fi
�r
•
.96
/�G��s��
y -.a - .. " n}.a j'' '.., �i. ✓;.fz %,y siyi.s.�'F ""�F .x�t
s ,:'�.- � _ _ - v-�%` _r_:.,�'S"� r K?.n 4.. , lr.: ,aS z >... z.,. C.c r �., .. , r•.,..,..
,��Nfy�
c`
a., ..-. �:...,.
.,471-.y
/ 53.t $t+
Yd`,,..5.. .) .......ss<
A i
SIZE
3/4"I,-
OD
1.050 1.315 1.650 1.900
ID
.930 1.189 1.502 1.720
IRRIGATION FLOW CHART
SCALE= WE&
1.
1° ROUND WA5HED GRAVEL BY 6" DEEP ON BOTTOM OF BOX
UICK COUPLER 2.
ENCLOSE 2" & SMALLER D.C.V.A. IN TWO METER BOXES STACKED ON
Dom'
TOP OF EACH OTHER OR, OVER SIZED. MUST HAVE REMOVABLE COVER.
PVC
3.
MAXIMUM OF 3" DISTANCE BETWEEN UNDERSIDE OF LID AND
HIGHEST POINT OF DEVICE.
-----«�-
4.
MUST INCLUDE (4) RESILIENT SEATED TEST -COCKS WITH PLUGS INSTALLED.
FLOW
5.
THE D.C.V.A. MUST INCLUDE (2) RESILIENT SEATED SHUTOFF VALVES.
DOUBLE CHECK
6.
Y-PATTERN D.C.V.A. SHOULD BE INSTALLED ON SIDE.
ASSEMBLY
7.
WHEN TEST -COCKS ARE FACING SIDEWAYS THERE MUST BE A 6" MINIMUM
CLEARANCE BETWEEN THEM AND SIDE OF BOX.
8.
MINIMUM OF 12" BETWEEN LOWEST POINT OF DEVICE AND DRAIN ROCK
9.
PROVIDE SUPPORT FOR 2" DEVICES. -- -
NOTES:
1.
INSTALL ACCORDING TO MANUFACTURER'S SPECIFICATIONS.
2.
ALL INSTALLATION MUST MEET MINIMUM STANDARDS
OF UNIFORM PLUMBING CODE do WATER DISTRICT.
3.
ASSEMBLY REQUIRES TESTING AND CERTIFICATION PRIOR TO USE
AND ANNUALLY THEREAFTER. FOR INFORMATION CONTACT WATER
QUALITY TECHNICIAN.
4. APPLY AND PAY FOR ALL REQUIRED PERMITS
PLAN
POINT OF CONNECTION =1X(tN�2 C4481< A 5EMELT
K_ - 7 8C 4LN N•TlBr.
SLEEVES
a f
2'DEPTH PREPARED TOP-SCIL DIAMETER OF ROOTBALL
TYPICAL
A SHRUB
r * ANTI
a" EXXTA
UZ r • ! HEM -FIR STAKE�
AL
EOM TO TREE WITH
GALVANIZED WIRE ENCASED
i
IN REINFORCED1DULLGREEN
WBRER
J�
HOSE AT POINT
OF PLAW COWAa.+r ¢"
TOP Of STAKE TO POINT
SH
GRADE
Y
_..wIM.
'FROM SIDE /
�•w ROOTBALL
i PREPARED SOIL
BACKPILL.
EXIST" SUBGRADE
CONIFEROUS,
• TREE -PLANTING
SCALRsXTA
SPAC"SPACING
t !
I .!
10.4(r
ii .738
+'
.52
20.8(r . !
30.W
``
SEE GROUNbCOVER PLANT KEY FOR
SPACING �A`. THIS CHARTIS TO BE USED . DETERMINE
N"BEP. OF GROLWXOVEFt PLANTS REQUIRED IN A GIVEN
A\*IA 0 0-
LOCATION
PLANT SPACrNG_ CHART
FOR 0 PLANTS ARE SPACED EQUIDISTANT FROM
OTHER, AS IN ALL MASSED r •
PLANT SPACING CHART
WALfisttTA
Z"
TREE SPECIMEN CENTRAL
2.375
LEADER SHALL NOT BE CUT
2.149
1/2" DIA. BLACK FLEX
GARDEN HOSE WITH
16 ga. TIE WIRE. SECURE
THRU"X"BRACE
lx3 HEM FIR
24 HEM FIR STAKES
JOP'iIONAI METHOD FOR
5A TERING
EYER6RN V TREE iNq.UDEB
0
3 EQ.SPACEb GUV WIRES
AR
0 AROUND
WJ rx2"x24" CEDAR STAKES
TREE
TREE WELL. AROUND
TREE 4" DEEP
-
MIN. 4$" DIAMETER
1
PREPARED SOIL BACICFILL
REMOVE TOP 1/3 OF BURLAP
1. WIDTH OF PLANTING PIT SHALL. BE
24" MIN.
2 TIMES LARGER THAN ROOT BALL.
2. PRE -STAIN ALL WOOD.
STAIN ALL FIELD CUTS
TYP -ICAL DECD U+t3US TREE PtANTIN
SGAL. mTs
R-398827