HomeMy WebLinkAboutW-395704N Sig L J M�M t'J zl:t U) / W 75 O 2 Z O I- rW V I� W U) I- rW 4./ Z ''Z) vJ FIRE HYDRANT SHALL BE COREY-TYPE EQUAL TO IOWA F-5110 OR COMPRESSION TYPE SUCH AS CLOW MEDALLION; M & H 929, MUELLER SUPER CENTURION 200, AND WATEROUS PACER WITH 6" MECHANICAL JOINT INLET WITH LUGS. 5-1/4" MAIN VALVE OPENING. TWO 2-1/2" HOSE CONNECTIONS NATIONAL STANDARD THREADS. 4" PUMPER CONNECTION CITY OF SEATTLE THREADS WITH A STORZ ADAPTOR, 4.875" SEATTLE THREAD X 5' STORZ, ATTACHED WITH 1/8" STAINLESS STEEL CABLE. 1-1/4" PENTAGON OPERATING NUT. FIRE HYDRANT TO BE PAINTED WITH TWO COATS OF PAINT. KELLY- MOORE/PRESERVATI VE PAINT No. 5780-563 DTM ACRYLIC GLOSS, SAFETY YELLOW OR APPROVED EQUAL. PUMPER CONNECTION TO FACE ROADWAY OR AS DIRECTED BY RENTON FIRE DEPARTMENT. FIRE HYDRANT EXTENSION TO BE USED IF REQUIRED. MIN. 18" TO 20" BEHIND BACK OF CURB OR 12" BEHIND BACK OF 3' SIDEWALK THAT IS ADJACENT TO CURB 4.875" x 5" STORZ 5'x5'x6" THICK CONCRETE PAD AROUND HYDRANT. FINISH TO MATCH SIDEWALK. EXPANSION JOINT AT 2„� ® BACK OF SIDEWALK fCONCRETE SIDEWALK OR PLANTING STRIP 36" MIN a COVER"t TWO-PIECE CAST IRON VALVE BOX WITH LUG TYPE COVER. EQUAL TO OLYMPIC FOUNDRY CO. STANDARD B" TOP SECTION WITH REGULAR BASE SECTION LENGTH TO FIT. VALVE NUT EXTENSION AS REQUIRED. RAISED PAVEMENT MARKER TYPE 88-A STIMSONITE TWO-WAY BLUE REFLECTIVE CONCRETE BLOCKING CONCRETE THRUST BLOCK �'y.- `; MAIN LINE TEE. WITH 6" FLANGE SIDE OUTLET. 6" GATE VALVE (FL X MJ) AWWA C-509, RESILIENT SEAT 6" DUCTILE IRON PIPE, CLASS 52 CEMENT LINED, LENGTH TO FIT 2-3/4" COR-TEN STEEL TIE RODS. 16" x 8" x 4" MININUM 1/2 YARD OF 1-1/4" WASHED DRAIN ROCK CONCRETE BEARING 1' ABOVE BOOT FLANGE. PLACE 8 MIL BLOCK UNDER HYDRANT POLYETHYLENE FILM AROUND TOP AND SIDES OF GRAVEL. FIRE HYDRANT ASSEMBLY LEVEL ALL GROUND a LEVEL ALL GROUND MIN 3RADIUS MIN 3' RADIUS 1 ONE MAN ROCK �6 1 1 //. • 6" CONCRETE PAD 6 `- 6" CONCRETE PAD CUT FILL HYDRANT LOCATION IN CUT OR FILL + :•� + PUBLIC WORKS (FIRE HYDRANT ASSEMBLY SM. PLAN - 310.1 DEPARTMENT MARCH 2010 FIRE HYDRANT NTS TESTING DETAIL f 10 FT EXISTING WATER LINE EXISTING TEE, DEAD END LINE, CAP OR PLUG DO NOT DISTURB BLOCKING NEW WATER LINE O H- VERTICAL CROSS (MJxFL) FOR POLYPIGGING 1-BLIND FLANGE ON TOP WITH 2"TAP & 2"PLUG 1-BLIND FLANGE ON BOTTOM 1-PLUG(MJ) W/2"TAP & 2" BLOW -OFF TEMP. BLOCK FINAL CONNECTION DETAIL NEW WATER LINE EXIST. WATER LINE = �\ F-ten v )E AFTER ALL TESTING, CLEANING BY POLYPIG AND DISINFECTION, REMOVE TEMP. BLOCK & BLOW -OFF & CONNECT TO EXISTING WATER LINE WITH SLEEVE (MJ) AND D.I. SPOOLS FINAL CONNECTION BY CITY FORCES` PUBLIC WORKS CONNECTION TO WATER MAIN STD. PLAN - 300.5 + + DEPARTMENT EXISTING TEE OR END LINE CAP MARCH 2O10 END CONNECTION Know what's below. Call 48 hours before you dig. NTS WATER MAIN r 2" CLOSE NIPPLE 2" 90' ELBOW - CONCRETE BLOCKING IF ADDITIONAL ADJUSTMENT IS REQUIRED, INSTALL 2-2" CLOSE NIPPLE AND 2-2" 90' BEND, SCREWED AT THIS POINT. FIELD LOCATE PLASTIC METER BOX IN PLANTER OR CAST IRON BOX IN PAVED OR CONCRETE AREAS. 2" CLOSE NIPPLE 2" 90' ELBOW 2" GALVANIZED PIPE AS REQUIRED PLAN VALVE NUT EXTENSION AS REQUIRED TWO PIECE CAST IRON VALVE (SEE DWG BR46 / PAGE B090) EQUAL TO OLYMPIC FOUNDRY CO. GROUND LINE CONCRETE SIDEWALK STANDARD 8" TOP SECTION, 6" MAX. WITH REGULAR BASE SECTION LENGTH TO FIT. - 2" RESILIENT SEATED GATE VALVE, SCREWED 2" GALVANIZED PIPE 12" LONG 2" CLOSE NIPPLE _ BETWEEN CAP OR PLUG AND 2" 90" ELBOW _ o D.P�oO" o a D O;p e�D"c 00 a°p INSTALL 4 MIL POLYETHYLENE 18" MAX. °- 0'2 "W ° o"-° PLASTIC COVER OVER WASHED o° n 0 "CO.OD 0 0° 0 �� ° ° ��0� GRAVEL. CUT HOLE FOR PIPE ° otl.o`oo. �oc 10 CU. FT. WASHED GRAVEL PASSING 1-1/2" AND RETAINED ON 1/4" MESH FOR DRAIN ELEVATION 2 1/2" NST (HOSE) AND 2 1/2" FNST CAP WITH GASKET 2"x2"x2" TEE AND 2" CAP 2" CLOSE NIPPLE BEWTEEN TEE AND 90' ELBOW. 2" 90" ELBOW STD. PLAN - 340.1 PUBiiC WORKS 2" BLOW -OFF DEPARTMENT PE..Rr%!AN=N- ASSEMBLY MARCH 2O10 BLOW OFF DETAIL DUNCANSON Company, Inc. 145 SW 155th Street, Suite 102 Seattle, Washington 98166 Phone 206.244.4141 Fax 206.244.4455 NTS 13N24" PLASTIC METER BOX EQUAL TO MID -STATES PLASTIC, INC. BCF SERIES MSBCF 1324-18 WITH 1.75" THICK DUCTILE IRON DIAMOND PLATE COVER EQUAL TO MID -STATES PLASTICS, INC. MSCBC-1324-R WITH READER LID AND 2" DRILLED HOLE FOR TOUCHREAD PIT LID (SEE DETAIL A -A) 9" MIN. 12" MAX FINISH GRADE �> - o 36" MIN COVER N M U 22-1/2" CITY PRIVATE PIPING PIPING IN UNIMPROVED RIGHT OF WAY INSTALL METER BOX AT PROPERTY LINE WITH 12" w • LONG COPPER TAILPIECE. w aI SIDEWALK a s:. WATER J FTOUCHREAD METER TO BE 12" SUPPLIED BY THE I Q CITY pi TYPE "K" SOFT o O COPPER TUBING NEW DUCTILE IRON WATERMAIN IF SERVICE LINE TO HOUSE IS 3/4" OR 1" TO BE INSTALLED IN THE FUTURE GALVANIZED INSTALL FORD C14-33 OR 44 F1PT PLUG x COMPRESSION COUPLING LOOP DOWN TO CENTERLINE OF WATER MAIN TO PROVIDE SLACK IN COPPER COPPERSETTER FOR 5/BN3/4" METER: FORD SERVICE LINE TO METER. VBH72-15W-44-33G, OR MCDONALD BRASS: 21-215WCQQ33, OR MUELLER: 3/4-8-2470-2 WITH ANGLE BALL VALVE ON INLET AND SINGLE CHECK VALVE ON OUTLET CORPORATION STOP WITH BALL VALVE. FORD COPPERSETTER FOR 1" METER: FORD VBH72-15W-44-44G, OR TAPERED THREAD (CC). QUICK JOINT MCDONALD BRASS: 21-415WCQQ44, OR MUELLER: 1-8-2470-2 (3/4" FB1000-3-Q) OR AY MCDONALD 4701E BOTH INLET AND OUTLET WITH QUICK JOINT. PADLOCK WINGS ON (1" F81000-4-Q) OR AY MCDONALD 47018 INLET ANGLE BALL VALVE AND SINGLE CHECK VALVE ON OUTLET. ALL FITTINGS SHALL BE WITH QUICK JOINT. NOTE: ALL METER BOXES INSTALLED WITHIN CONCRETE OR PAVED DRIVEWAYS SHALL BE CAST-IRON EQUAL TO OLYMPIC FOUNDARY. EXPANSION JOINTS MUSH BE INSTALLED ON BOTH SIDES OF METER BOX. DRILL 2" DIA. HOLE FOR AMR (AUTOMATIC METER READ) TOUCHREAD DEVICE - 2-1/2" MIN. FROM NEAREST AND FRONT EDGE OF PIT LID J I NOTE: THE CENTER OF THE HOLE MUST BE AT LEAST 1" FROM UNDERNEATH RIBS UNLESS THE RIB SPACING ALLOWS THE NUT TO TIGHTEN AGAINST THE OPEN SIDE OF MORE THAN ONE RIB. + + PUBLIC WORKS 34" AND 1" WATER SERVICE SM. PLAN - 320.1 DEPARTMENT NUVE_LIBER 2009 EXISTING WATER LINE PLAN VIEW TESTING DETAIL gT7 LINE VERTICAL CROSS(MJxFL) FOR POLYPIGGING OME BLIND FLANGE ON TOP WITH 2'TAP L 2'PLUG ONE DLIND FLANGE ON BOTTOM ONE (NJ) PLUG WITH 2' TAP & 2' TEMPORARY BLOW -OFF TEMPORARY BLOCK CUT -IN (BY CITY FORCES) TEE (FLxFL) W/ CONIC. BLOCK 2- GATE VALVES (FLxMJ) 2- SOLID SLEEVES (MJ) OR RO-MAC COUPLINGS 1- ADAPTER (FL x MJ) 1- PLUG CMJ) W/2'TAP L TEMP. ELDW-OFF TEMP. BLOCK EXISTING WATER LINE EXISTING WATER LINE FINAL CONNECTION DETAIL II�C E AFTER ALL TESTING, CLEANING BY POLYPIG, AND DISINFECTION, REMOVE TEMP. BLOCK L BLOW -OFF L CONNECT WITH SLEEVE (NJ) L DJ, SPOOLS I I FINAL CONNECTMN BY CITY FORCES + XISTING WATER LINE PUBLIC WORKS CONNECTION TO WATER MAIN CUT SM. PLAN - 300.3 DEPARTMENT IN -LINE TEE & TWO VALVES MARCH 2O10 CUT IN CONNECTION NTS 3 PER CITY COMMENTS 2 PER RESUBMITTING SCREENING 1 PER CITY COMMENTS NO. REVISION WATER SERVICE W z J ar 3� I NTS ) VCA N OTE IVCA SHALL BE LOCATED IN THE GARAGE BETWEEN -HE BUILDING AND THE PRESSURE REDUCING VALVE U_ IIJ O EL DIRECTION OF FLOW 0 W „ (M3IN.) 1 6" MIN. I6"MIN.(TYP.) I I \-UNION (TYP.) PLAN It a n 11-1/4' BEND 22-1/2" BEND 45" BEND 1 ' CAP TEE 90" BEND THRUST BLOCK BEARING AREA IN SQUARE FEET (SEE NOTES) FOR HORIZONTAL AND DOWNWARD VERTICAL BENDS SOIL FIRM SILT OR FIRM SILTY SAND COMPACT SAND COMPACT SAND & GRAVEL 90, 45' BEND 11 1/4' 90' 45' BEND 11 1/4' 90' 45' BEND 11 1/4' FITTING BEND TEE CAP OR PLUG & 22 1/2' BEND TEE CAP OR PLUG & 22 1/2' BEND TEE CAP OR PLUG & 22 1/2' BEND BEND BE 4 7.0 4.2 4.2 1.7 2.9 2.1 2.1 1.0 2.2 1.8 1.6 1.0 6 13.3 9.4 9.4 3.8 6.7 4.7 4.7 1.9 5.0 3.5 3.5 1.4 8" 23.3 16.7 16.7 8.7 11.7 8.4 8.4 12' 53.0 37.5 37.5 15.D 26.5 18.8 18.8 7.5 20.0 14.0 14.0 5.6 AREAS CALCULATED ON 300 PSI TEST PRESSURE. 3'-0" MIN. COVER FOR WATERMAIN LESS THAN 12". 4'-0" MIN. COVER FOR WATERMAIN 12" OR GREATER. MAX. HEIGHT OF THRUST BLOCK (FT) = 0.5 x DEPTH OF TRENCH MIN. HEIGHT OF THRUST BLOCK (FT) = O.D. PIPE + 1.0' iRUST BLOCK BEARING REA REFERS TO THE WE OF BLOCK MEASURED IN SQUARE FEET NOTES: 1. LOCATION AND SIZE OF BLOCKING FOR PIPE LARGER THAN 12"DIAMETER AND FOR SOIL TYPES DIFFERENT THAN SHOWN SHALL BE DETERMINED BY THE ENGINEER. 2. ALL BLOCKING SHALL BE POURED IN PLACE AGAINST UNDISTURBED NATIVE GROUND. 3. ALL POURED THRUST BLOCKS SHALL BE BACKFILLED AFTER MIN. 1 DAY. PRESSURE TESTING SHALL OCCUR AFTER CONCRETE HAS REACHED NOMINAL COMPRESSIVE STRENGTH. 4. ALL BLOCKING SHALL BE CONCRETE CL 5 5. BLOCKING AGAINST FITTINGS SHALL BEAR AGAINST THE GREATEST FITTING SURFACE AREA POSSIBLE. BUT SHALL NOT COVER OR ENCLOSE BELL ENDS, JOINT BOLTS OR GLANDS REASONABLE ACCESS TO BOLTS AND GLANDS SHALL BE PROVIDED. CONCRETE BLOCKING FOR SM. PLAN - 330.2 • PUHHC WORKS + � + DEPARTMENT VERTICAL AND DOWNWARD VERTICAL BENDS MARCH 2O10 TO CITY may ,•••,�• METER STACKED METER SECTION 6" MIN. FREE BOXES DRAINING GRAVEL NOTES: 1. ALL DOUBLE CHECK VALVE ASSEMBLIES (DCVA's) MUST BE LISTED ON LATEST LIST OF "BACKFLOW PREVENT0N ASSEMBLIES APPROVED FOR INSTALLATION IN WASHINGTON STATE", PUBLISHED BY STATE OF WASHINGTON DEPARTMENT OF HEALTH. 2. THE OWNER/APPLICANT MUST OBTAIN A SEPARATE CITY OF RENTON PLUMBING PERMIT FOR THE INSPECTION OF THE INSTALLATION OF THE DCVA AND PIPING. THE OWNER SHALL FURNISH, INSTALL AND MAINTAIN THE DCVA AND.ALL PIPING AND APPURTENANCES SHOWN ON THIS PLAN.. 3. THE DCVA MUST BE TESTED BY A STATE CERTIFIED BACKFLOW ASSEMBLY TESTER AFTER ITS INITIAL INSTALLATION, AFTER REPAIRS AND ANNUALLY THEREAFTER AT OWNER'S EXPENSE. A COPY OF THE TEST REPORT SHALL BE SENT OR FAXED TO CITY OF RENTON WATER UTILITY ENGINEERING DEPT.. ATTN: WATER UTILITY CROSS -CONNECTION CONTROL SPECIALIST, FAX NO. 425-430-7241. 4. DCVA AND METER BOX SHALL BE LOCATED ON PRIVATE PROPERTY AND AS NEAR AS POSSIBLE TO THE WATER METER. PUBLIC WORKS IY4" TO 2" DOUBLE CHECK VALVE STD. PLAN - 340.8 .+ + DEPARTMENT ASSEMBLY FOR IRRIGATION OR RESIDENTIAL FIRE SPRINKLER MARCH 2O10 SURVEYED: JMB DESIGNED: HMD LTK 9/8/17 HMD LTK 7/18/17 HARD DRAWN: HARD LTK 7/12/1 CHECKED: HMD BY DATE APPR APPROVED: HMD SCALE: SEE PLANS ONE INCH AT FULL SCALE IF NOT ONE INCH SCALE ACCORDINGLY D VC A NTS VERTICAL: NAVD 1988 HORIZONTAL: NAD 1983/1991 VD W 0INA CONCRETE BLOCKING LO O N O •i, NJ NTS ti WATER PLAN GENERAL NOTES (STD PLAN NO, 300 N 0 1. ALL WORK AND MATERIALS SHALL BE IN ACCORDANCE WITH THE LATEST EDmON OF THE CIIY OF RENTON PUBLIC O WORKS STANDARD SPECIFICATIONS AND SPECIAL PROVISIONS AND WSDOT / APWA STANDARD SPECIFICATIONS, LATEST EDITION AS AMENDED BY THE CIIY OF RENTON. A SET OF CITY APPROVED PLANS SHALL BE KEPT AT THE JOB SITE WHENEVER I` CONSTRUCTION IS IN PROGRESS. A PRE -CONSTRUCTION CONFERENCE SHALL BE HELD PRIOR TO THE START OF CONSTRUCTION. r THE CONTRACTOR AND OR DEVELOPER SHALL BE RESPONSIBLE FOR SECURING ALL NECESSARY PERMITS PRIOR TO nj CONSTRUCTION. L.L 2. ALL EXISTING UTILITIES SHALL REMAIN IN SERVICE DURING CONSTRUCTION UNLESS OTHERWISE NOTED. THE CONTRACTOR SHALL CALL 1-800-424-5555 TO VERIFY UTILIIY LOCATIONS BEFORE BEGINNING EXCAVATION. 3. ALL MATERIALS USED FOR THE CONSTRUCTION OF WATER SYSTEM IMPROVEMENTS SHALL BE NEW AND UNDAMAGED, AND "CATALOG CUTS" FOR ALL MATERIALS SHALL BE APPROVED IN WRITING BY THE CIIY OF RENTON PRIOR TO BRINGING ANY MATERIALS ON -SITE. 4. ALL WATER MAIN PIPE MATERIALS SHALL BE CEMENT LINED DUCTILE IRON PIPE, THICKNESS CLASS 52 PER AWWA C 151AND C 104. PIPE JOINTS SHALL BE PUSH -ON OR MECHANICAL JOINT. CAST IRON OR DUCTILE IRON PIPE FITTINGS SHALL BE CLASS 250 AS PER ANSI/AWWA C110/A21.10-82. ALL DUCTILE IRON PIPE AND FITIINGS SHALL BE WRAPPED WITH 8-MIL BLACK, TUBE -TYPE, POLYETHYLENE PLASTIC PER AWWA C105 STANDARDS. 5. MINIMUM COVER FROM TOP OF WATER MAINS TO FINISHED GRADE SHALL BE 36 INCHES FOR PIPE DIAMETER OF 10-INCH OR LESS AND 48 INCHES FOR PIPE DIAMETER OF 12-INCH AND LARGER. MAXIMUM COVER FOR ALL WATER MAINS SHALL BE 60 INCHES. ANY DEVIATIONS MUST BE APPROVED BY THE CIIY OF RENTON PRIOR TO CONSTRUCTION. WHERE UTILITY CONFLICTS OCCUR, THE PROFILE OF THE WATER MAIN SHALL BE ADJUSTED AS NECESSARY TO CLEAR CONFLICTS AND TO PROVIDE MINIMUM COVER. PIPE DEFLECTION SHALL NOT EXCEED ONE-HALF OF PIPE MANUFACTUREWSSPECIFICATION FOR SIZE OF PIPE USED. ALL TRENCH BACKFILL SHALL BE COMPACTED TO 95 PERCENT MAXIMUM DRY DENSIIY AS DETERMINED BYTHE MODIFIED PROCTOR TEST METHOD {MOD) IN ROADWAYS, ROADWAY SHOULDERS, ROADWAY PRISM AND DRIVEWAYS, AND 85 PERCENT MOD IN UNPAVED AREAS. ALL PIPE ZONE COMPACTION SHALL BE 95 MOD. 6. CONCRETE BLOCKING FOR WATER MAINS SHALL BE DESIGNED, INSTALLED AND POURED IN PLACE IN ACCORDANCE WITH CIIY OF RENTON STANDARD DETAILS AND SPECIFICATIONS AND SHALL BE INSTALLED AT ALL VERTICAL AND HORIZONTAL BENDS, FITTINGS AND BASE OF HYDRANTS. MEGA -LUGS {OR SIMILAR PRODUCT) MAY BE REQUIRED ON ALL MECHANICAL JOINTS IN ADDITION TO CONCRETE BLOCKING. 7. ALL NEW WATER MAIN PIPES AND FITTINGS SHALL HAVE A FOAM PIPE PIG RUN THROUGH THEM PRIOR TO BEING FLUSHED, DISINFECTED, AND TESTED. CLEANING, PRESSURE AND PURIIY TESTING SHALL BE DONE IN THE PRESENCE OF AND UNDER THE SUPERVISION OF A CITY OF RENTON UTILITY INSPECTOR. THE CONTRACTOR SHALL SUPPLY, INSTALL AND REMOVE PLUGS, CORPORATION STOPS, BLOW -OFF ASSEMBLIES, AND THRUST RESTRAINT/ BLOCKING FOR TESTING AND PURIIY ACCEPTANCE. NO CONNECTION SHALL BE MADE BETWEEN THE NEW MAIN OR BETWEEN THE NEW WET -TAP VALVE TO AN EXISTING MAIN UNTIL THE NEW PIPING HAS BEEN FOAM -PIGGED, DISINFECTED, FLUSHED, AND PASSED BOTH PRESSURE AND PURIIY TESTING. 8. NEW WATER MAINS INCLUDING SERVICE LATERALS SHALL BE TESTED AT A STATIC PRESSURE OF 150 PSI ABOVE WORKING PRESSURE WITH A MINIMUM OF 225 PSI TEST PRESSURE FOR 120 MINUTES WITH A MAXIMUM OF 5 PSI PRESSURE DROP DURING THE ENTIRE TEST PERIOD. UPON SATISFACTORY COMPLETION OF THE PRESSURE TEST, THE LINE SHALL BE DISINFECTED, FLUSHED, AND THEN WATER SAMPLES SHALL BETAKEN FOR PURITY TESTING BY THE PUBLIC WORKS INSPECTOR. LO 9. THE CONTRACTOR SHALL NOTIFY THE CITY OF RENTON WATER UTILIIY AND MAINTENANCE DEPARTMENTS AT LEAST 10 WORKING DAYS PRIOR TO MAKING CONNECTIONS TO THE EXISTING WATER SYSTEM. THE CONTRACTOR SHALL EXPOSE THE EXISTING WATER MAIN AND FITTINGS AT THE CONNECTION POINT BEFORE ORDERING THE NECESSARY ADAPTORS AND FITTINGS REQUIRED FOR THE FINAL CONNECTION. THE CONTRACTOR SHALL EXCAVATE, REMOVE ALL SURFACE MATERIALS, AND PROVIDE SHORING AND ALL MATERIALS REQUIRED FOR THE CITY OF RENTON TO PERFORM THE CONNECTION TO THE EXISTING WATER SYSTEM. THE CONTRACTOR SHALL PROVIDE AND INSTALL BACKFILL, CONCRETE BLOCKING, AND COMPLETE W SURFACE RESTORATION. W-395704 0 = IN COMPLIANCE WITH CITY OF RENTON STANDARDS Z ELOPMENT ENGINEERING O Lrnair10/24/2017 1— W RECORD DRAWING NO CHANGES 0 W DATE: CITY OF SUNSET'S EDGE TOWNHOMES FIELD600/1/17 R E N TO N WATER DETAILS AND NOTES W PAGE: ' " DRAWING N0: Z/1 Plan ning/Building/Public Works Dept. 701-707 SUNSET BOULEVARD NE, RENTON, WA C3"3 SUNSET'S EDGE TOWNHOMES SHEET: Z 0F: Z DCI PROJECT NO. 15375