HomeMy WebLinkAboutR-389787r-
04
;� WAS i
o
03
J to
/NORTHWEST
a ��o
EPDXY FILL EPDXY FILL �
TRA FF/C EXPERTS
g - _ FSS G,
11410 NE 124th St., #590, Kirkland, WA 98034 ONAI ab
CONDUIT ENTR. AREA S�
INLINE SPLICE Phone: 425.522.4118 Fax: 425.522.4311
p WYE SPLICE o.o
4.
SPLICE KIT ,
- -t PLAN ME ..
LUMINAIRE WIRES WILL BE A CONTINUOUS RUN s _ SIZE TO FIT SIZE TO FIT
FROM FUSE HOLDER i0 FIXTURE WITH
W NO SPLICES. CABINET CABINET
A/ Q GROUND ROD - - _ 6• 6 I' -O" ..
U r -Grade Level
A
.d
W FUSE KITS WICK DISCONNECT TO LUMINAIRE _ N
Z 3 AMP IN LINE FUSE KITS LUMINAIRE HARES WILL BE 2
` p S.E.C. OR EQUAL w • -
/ AWG IN A JACKETED CAB
REFER TO WS00T LOCKING LID STANDARD 4'11 GREEN INSULATED PARE -
DUTY JUNCTION BOX TYPES 1 & 2 TO FIXTURE GROUND LUG - FRONT MEW SIDE MEWe
'SYANDARO PLAN J -40.10 -OJ
Qo
Z GROUND LUG - -
A. 1/4". MHJMAl1M '
DRAIN HOLE STREET LIGHT CONTACTOR FOUNDATION -
- SPLICE KITS CLEAR EPDXY 2' MIN. GROUT TOP OF CONCRETE FOUNDATION TO STREET
KITS ON ALL THRU
WARE RUNS UNDER POLE BASE BE LEVEC:WITH TOP OF SIDEWALK,
1 4" CONCRETE PAO OBER CURBa DIAMETER = 7/8" _ -
Q
Ld
2 IN. /B BARE COPPER ,.Y�i II (I I -
_
GROUND WIRE II II I ^ _ 7 /Q n _ - _ -
' ^ GROUND II II j�--`F C, _ Shim to plumb Shim to plumb
V) U CLAMP - ASmBUILTS
See Note 3 See Note 3 - -
W A` hO.per +� µ bar c "I CERTIFY THAT THE INFORMATION SHOWN HEREON WHICH WAS AS -BUILT BY D.R.
LOAD LINE o �4 bar oath corner c /4 bar oath tamer
WIREW/GREEN INSULATION 2" PVC CONDUIT II II f �
FROM SERVICE CABINET SYSTEM II / FUSE /
2 - LIGHTING SYSTEM � `� � - - 'I 4" � 4»... _ � _ -� � -- STRONG, AND MAY INCLUDE LOCATIONS, ELEVATIONS, DEPTHS, PIPE SIZES, AND AS -
VARIES TO CONTACTOR I 6' MIN r to 2• 6• MIN -BUILT COMMENTS
(SIZED AS REO'0.) CONCRETE - fl - ff - 3/A• diameter plastic drain 3/11" d'rometer pbsGc drab - ACCURATELY REFLECTS EXISTING FIELD CONDITIONS AS -
FouNDnnoN 3• SO. OR DIA. 1 /8 O 1/8)) DETERMINED BY ME OR UNDER MY DIRECT SUPERVISION ON THIS DATE: 1/12/2018.
5/8"x11' COPPE(2 CLAD
SIDE MEW SIDE VIEW
GROUND ROD
CUTTING RINGS 1 -60
Cab+ z depth Cabinet depth
IZ - - -
NOTA -----
L EQUIPMENT GROUND WIRE &BARE WIRE SHALL 8E $ J4 bar each r r4 bar each RECOMMENDED
Y SECURELY FASTENED TO THE GROUND LUG INSIDE THE s comer s comer
Q O POLE HANDHOLE. ALL BONDING & GROUNDING CONNECTIONS s C + A4 hoope + R4 Nowa FOR APPROVAL
SHALL REMAIN ACCESSIBLE FOR INSPECTION AND FUSE K I T
MAINTENANCE.
S 8
Vm
� 2 IF THE FIXTURE MANUFACTURER HAS MADE PROVISION FOR BY
�...� THE ATTACHMENT OF A GROUND WIRE A GREEN INSULATED
' W WIRE OF THE SAME SIZE SHALL BE RUN FROM THE FIXTURE PLAN MEw PLAN MEw BY
TO THE GROUND LUG INSIDE THE POLE HANDHOLE. IF THE
T \ N PAD MOUNT PAD MOUNT
FIXTURE MANUFACTURER HAS A GROUND LUG A8 GREEN
INSULATED WIRE SHALL BE RUN FROM THE FIXTURE g CONTROLLER CABINET FOUNDATION BATTERY BACKUP SYSTEM (BBS) FOUNDATION BY
— GROUND LUG TO THE POLE GROUND LUG.
FUSE KIT & SPLICE KIT DETAILS'`' For NOTES see Std. Plan 126.2 CHECKED FOR COMPLIANCE
m M. PLAN — 119
PUBLIC WORKS TYPICAL LIGHTING APPROV>?Db �'`" s'rn. PLAN — 126.1 TO CITY STANDARDS
oY DEPARTMENT UNDERGROUND SYSTEM - + • ; PUBLIC WORKS CABINET FOUNDATION DETAILS P ROVE '
0
�._u I. a C Y DEPARTMENT
c ... � )c)�+ ADOPTED`' �1 . DATE / 3 d / 7
c :��� _ - - :- - - _ — V CITY OF RENTONedDATE
IL Standard plans
�`N LST DATE: 11/5/96
_ DATE
Ob
CM DATE REVISION BY APPR' DWG. NAME: JR -12 SP PAGE: J013
x�
U Z _ !
NZo STREET LIGHTING CONTACTOR CABINET
0
o <Z r WIRING SCHEMATIC
TYPE III SERVICE 120/240 VOLT
O C) .e 3
DO
100 A MAIN BREAKER (MIN.)
�$
� Z 2 POLE 240 VOLT
8 STREET LIGHT POLE z O O
JUNCTION BOX o
z 8 0 PLAN VIEW m
a
~ §4 BRANCH BREAKERS E
Owl. i
OL" 120/240 VOLT
W a ev TEST
ErW O N SWITCH 16 POLE
L-1 w
o� a
w�& 2
DOW a e I I B
Q 4" DEEP A
TERMINAL B C
xg o 0 0-0 �m BLOCK
MIS
0-0
m u �W Y17711_ �l 0 'U B >t g A UTILITY
A Pr.- I° i, j� Wit]' A PLUG (G I)
u
x
m� awl A STREET LIGHTING
a _ .I„ T.t ti` a a B CONTACTORS
SIDE VIEW sa#<m xa o
ac� r
J • . e' _
Z D
a• .. j' 1--i L®� W CIRCUIT WIRES TO LIGHTING RUNS
LIGHTING STANDARD &JUNCTION BOX I W I A
PHOTO -CELL TO GROUND
ry N 0 I m Z Pa MOUNTED ON ROD
PLAN VIEW t I p NEAREST
.LUMINAIRE
-- — --' r I.X.I I . <4
X.