HomeMy WebLinkAboutP_Floor_Plan_170518_v1.pdf0 0 0 0 0 0 EXISTING PRECAST CONC, PANEL DEMO EXISTING EXTERIOR PEDESTAL LEAVING COLUMN � ---DEMO EXISTING STOREFRONT AND FRAMING ABOVE COMPLETE DEMO EXISTING WALK COMPLETE FOR NEW CONSTRUCTION i DEMO EXISTING SOFFIT AND FRAMING COMPLETE WALL TYPES 01 EXTERIOR CONCRETE WALL: 62" TEXTURED PRECAST INSULATED CONCRETE WALLS PANELS TO MATCH EXISTING. ❑2 CMU WALL: 8" FULLY GROUTED REINFORCED CMU WALL TO STRUCTURE - SLAB TO DECK. r3 CMU WALL: 8" FULLY GROUTED REINFORCED CMU WALL TO BOTTOM OF EXISTING WALL CONCRETE WALL. CMU WALL TO MEET LEVEL 3 BALLISTIC CONSTRUCTION BY US BANK. EXISTING CONCRETE WALL ABOVE TO BE RETROFITTED TO ME LEVEL 3 BALLISTIC CONSTRUCTION BY US BANK. KEY NOTES Q1 BOLLARD, SEE DETAIL Q2 12'-0" X 14'-0" HIGH ROOL-UP DOOR - MOTORIZED CONTROLS, REMOTE CONTROL OF DOOR WITHIN RECEIVING ROOM INSIDE CASH VAULT. Q3 BULLET RESISTANT GLASS AND FRAME ASSEMBLY. PROVIDE AND INSTALLED BY US BANK TENANT IMPROVEMENT GENERAL CONTRACTOR. CORE AND SHELL CONTRACTOR TO COORDINATE INSTALLATION REQUIREMENTS AND PROVIDE ROUGH OPENING T.I. G.C. TO PAINT METAL FRAME AFTER INSTALL. ® 542"W X 57$"H OPENING REQUIRED FOR BULLET RESISTANT CART PASS THRU. BULLET RESISTANT CART PASS THRU PROVIDED AND INSTALLED BY US BANK TENANT IMPROVEMENT GENERAL CONTRACTOR. CORE AND SHELL GENERAL CONTRACTOR TO COORDINATE REQUIREMENTS AND PROVIDE ROUGH OPENING. G.C. TO PAINT UNIT AFTER INSTALL. © NOT USED O7 42" X 7'-0" BULLET RESISTANT DOOR / FRAME PROVIDE BY US BANK TENANT IMPROVEMENT GENERAL CONTRACTOR. CORE AND SHELL GENERAL CONTRACTOR TO COORDINATE INSTALLATION REQUIREMENTS. PROVIDE ROUGH OPENING. G.C. TO REFER TO BULLET RESISTANT DOOR NOTES / REQUIREMENTS ON SHEET A4.1. HARDWARE TO BE PROVIDED BY TENANT IMPROVEMENT G.C. ELECTRIC STRIKE ELECTRONIC PANIC DEVICE WITH LEVER TRIM - DELAYED EGRESS - FAIL SECURE CLOSER, INTERLOCK CONTROL HARDWARE. T.I. G.C. TO PAINT DOOR / FRAME. SEE DETAIL 2/D. ® G.C. TO PAINT ALL EXPOSED CONDUIT / J -BOXES AFTER INSTALLATION. LEGEND 101 DOOR NUMBER �j DEMO EXISTING ROOM STOREFRONT AND DEMO EXISTING EXISTING WALL T_ C:) FRAMING ABOVE WALK COMPLETE FIRE EXTINGUISHER NOTES: COMPLETE FOR NEW WINDOW TYPES. CONSTRUCTION v w / f O J o IY J H a_ EXISTING Q 06 PRECAST CONC, Z Q PANEL, ABOVE o CN DEMO EXISTING 00 SOFFIT AND FRAMING Li COMPLETE DEMO EXISTING EXTERIOR PEDESTAL LEAVING COLUMN � ---DEMO EXISTING STOREFRONT AND FRAMING ABOVE COMPLETE DEMO EXISTING WALK COMPLETE FOR NEW CONSTRUCTION i DEMO EXISTING SOFFIT AND FRAMING COMPLETE WALL TYPES 01 EXTERIOR CONCRETE WALL: 62" TEXTURED PRECAST INSULATED CONCRETE WALLS PANELS TO MATCH EXISTING. ❑2 CMU WALL: 8" FULLY GROUTED REINFORCED CMU WALL TO STRUCTURE - SLAB TO DECK. r3 CMU WALL: 8" FULLY GROUTED REINFORCED CMU WALL TO BOTTOM OF EXISTING WALL CONCRETE WALL. CMU WALL TO MEET LEVEL 3 BALLISTIC CONSTRUCTION BY US BANK. EXISTING CONCRETE WALL ABOVE TO BE RETROFITTED TO ME LEVEL 3 BALLISTIC CONSTRUCTION BY US BANK. KEY NOTES Q1 BOLLARD, SEE DETAIL Q2 12'-0" X 14'-0" HIGH ROOL-UP DOOR - MOTORIZED CONTROLS, REMOTE CONTROL OF DOOR WITHIN RECEIVING ROOM INSIDE CASH VAULT. Q3 BULLET RESISTANT GLASS AND FRAME ASSEMBLY. PROVIDE AND INSTALLED BY US BANK TENANT IMPROVEMENT GENERAL CONTRACTOR. CORE AND SHELL CONTRACTOR TO COORDINATE INSTALLATION REQUIREMENTS AND PROVIDE ROUGH OPENING T.I. G.C. TO PAINT METAL FRAME AFTER INSTALL. ® 542"W X 57$"H OPENING REQUIRED FOR BULLET RESISTANT CART PASS THRU. BULLET RESISTANT CART PASS THRU PROVIDED AND INSTALLED BY US BANK TENANT IMPROVEMENT GENERAL CONTRACTOR. CORE AND SHELL GENERAL CONTRACTOR TO COORDINATE REQUIREMENTS AND PROVIDE ROUGH OPENING. G.C. TO PAINT UNIT AFTER INSTALL. © NOT USED O7 42" X 7'-0" BULLET RESISTANT DOOR / FRAME PROVIDE BY US BANK TENANT IMPROVEMENT GENERAL CONTRACTOR. CORE AND SHELL GENERAL CONTRACTOR TO COORDINATE INSTALLATION REQUIREMENTS. PROVIDE ROUGH OPENING. G.C. TO REFER TO BULLET RESISTANT DOOR NOTES / REQUIREMENTS ON SHEET A4.1. HARDWARE TO BE PROVIDED BY TENANT IMPROVEMENT G.C. ELECTRIC STRIKE ELECTRONIC PANIC DEVICE WITH LEVER TRIM - DELAYED EGRESS - FAIL SECURE CLOSER, INTERLOCK CONTROL HARDWARE. T.I. G.C. TO PAINT DOOR / FRAME. SEE DETAIL 2/D. ® G.C. TO PAINT ALL EXPOSED CONDUIT / J -BOXES AFTER INSTALLATION. LEGEND 101 DOOR NUMBER �j WINDOW NUMBER ROOM 999 ROOM NAME/NUMBER EXISTING WALL T_ C:) NEW WALL CF.E. FIRE EXTINGUISHER NOTES: 1. SEE SHEETS A4.1 DOOR SCHEDULES, DOOR & WINDOW TYPES. w PARTIAL DEMOLITION FLOOR PLAN PARTIAL FLOOR PLAN SCALE NOTED ON DRAWINGS 0 0 o FOR 2436 SHEETS. Z SCALE: 1/4"= 1'-0" Z SCALE: 1/41p= 1'-0" ui U) © CORNERSTONE ARCHITECTURAL GROUP 4 41 0 IRIEGISTER__ED I ARCHITECT Richard V. Utt STATE OF WASHINGTON T_ C0 T_ C:) O J Z � z O r O v w Lu 0 O J o IY J H a_ Q 06 � Q Z Q o CN 00 Li P- 0 0 LLJ LJJ C= ~W 0 C/� Q:�