Loading...
HomeMy WebLinkAboutRS_Traffic_Analysis_Final_170518_v1.pdf 2813 Rockefeller Avenue  Suite B  Everett WA, 98201 Tel: 425-339-8266  Fax: 425-258-2922  E-mail: info@gibsontraffic.com MEMORANDUM To: Rick Utt, Cornerstone Architectural Group From: Brad Lincoln, PE Project: US Bank Expansion GTC #17-027 Subject: Traffic Analysis Date: May 10, 2017 This memorandum summarizes the trip generation and traffic mitigation fee calculations for the US Bank Expansion project. The project site is located along the east side of East Valley Road, north of SW 27th Street in Renton. The project is proposed to include a 2,673-square-foot addition to an existing office building, which is currently utilized by US Bank. A site vicinity map in included in Figure 1. SW 27th St Lind Ave SW SITE E Valley Rd US Bank Expansion Traffic Analysis Gibson Traffic Consultants, Inc. May 2017 info@gibsontraffic.com 2 GTC #17-027 Figure 1: Site Vicinity 1. Trip Generation Calculations Neither the use of the existing US Bank tenant space within the existing office building nor the proposed use of the proposed expansion space is bank branch operations open to the general public for provision of services to customers, such as bank transactions, opening accounts, etc. The trip generation calculations for the proposed expansion space are based on data contained in the Institute of Transportation Engineers’ (ITE) Trip Generation Manual, 9th Edition – Volume 2: Data (2012). Because neither the use of the existing US Bank tenant space within the existing office building nor the proposed expansion space is for use as a bank branch open to the public for provision of such retail banking services to bank customers, the average trip generation rates for ITE Land Use Code 710, General Office Building, have been used for the proposed use. This use is consistent with the use of the space in the existing building and the anticipated use of the expansion. The trip generation calculated for the proposed US Bank Expansion is summarized in Table 1. Table 1: Trip Generation Calculations 2,673 SF General Office Average Daily Trips AM Peak-Hour Trips PM Peak-Hour Trips Inbound Outbound Total Inbound Outbound Total Inbound Outbound Total Generation Rate 11.03 trips per 1,000 SF 1.56 trips per 1,000 SF 1.49 trips per 1,000 SF Splits 50% 50% 100% 88% 12% 100% 17% 83% 100% Trips 15 1415 29 4 0 4 1 3 4 The US Bank Expansion is anticipated to generate 29 average daily trips with 4 AM and PM peak- hour trips. The City of Renton Policy Guidelines for Traffic Impact Analysis for New Development identifies that a traffic impact analysis is only required for developments that generate 20 or more AM or PM peak-hour trips. The US Bank Expansion will not exceed this threshold and, therefore, a full traffic impact analysis is not required. 2. Transportation Impact Fees The transportation impact fee for the US Bank Expansion has been calculated using the latest City of Renton Fee Schedule. The City of Renton requires payment of transportation impact fees for office at the rate of $7.29 per square-foot. The 2,673 SF US Bank Expansion would therefore have City of Renton transportation impact fees of $19,486.17. It is important to note that this fee does not vest and is calculated when the building permits are applied for. A ITE Data A - 1 A - 2 A - 3