HomeMy WebLinkAboutM_Application_Review_Sheets_Fire_091116.pdfCITY OF RENTON
FIRE PREVENTION BUREAU
DATE: November 12, 2009
TO: Jerry Wasser, Associate Planner
FROM: Corey Thomas, Plans Review Inspector
SUBJECT: Wilson Park Preliminary Plat
ENVIRONMENTAL IMPACT COMMENTS:
1. A fire mitigation fee of $488.00 is required for all new single-family
structures. Credit will be granted for the one single family home to be
removed.
CODE -RELATED COMMENTS:
1. A fire hydrant with 1000 GPM fire flow is required within 300 feet of
all new single-family structures. If the building square footage exceeds
3600 square feet in area, the minimum fire flow increases to 1500 GPM
and requires two hydrants within 300 feet of the structures.
2. Fire apparatus access roadways appear adequate. All required
roadways shall be fully paved and shall not exceed 15% grade elevation,
turning radius is 25 -foot inside and 45 -foot outside. Proposed access
gate shall meet all requirements for fire department standards including
Click -2 -Enter control device. Minimum 20 -foot roadway sections shall
be signed for "No Parking - Anytime" on each side at maximum 50 -foot
intervals.
City of Renton Department of Community & Economic Development
ENVIRONMENTAL & DEVELOPMENT APPLICATION REVIEW SHEET
REVIEWING DEPARTMENT: ; ')
iZC_- COMMENTS DUE: NOVEMBER 16, 2009
APPLICATION NO: LUA09-140, ECF, PP DATE CIRCULATED: NOVEMBER 2, 2009
APPLICANT: Steve Beck PLANNER: Jerry Wasser
PROJECT TITLE: Wilson Park Preliminary Plat PLAN REVIEWER; Kayren Kittrick
SITE AREA: 108,884 square feet EXISTING BLDG AREA (gross): 3,520 square feet
LOCATION; 720 S 55" Street PROPOSED BLDG AREA (gross) N/A
JWORK ORDER NO: 78147
SUMMARY OF PROPOSAL; The applicant is requesting an Environmental (SEPA) Review and approval of a Preliminary Plat for the
subdivision of a 108,884 square foot parcel in the R-1, R-8 and R-14 zones and in the Urban Separator Overlay. The proposal
encompasses 13 lots and 4 tracts (for open space and storm detention). The proposed lots range in size from 4,639 square feet to
6,512 square feet with a density of 7.99 dwelling units per acre. The proposed lots are intended for the future construction of
single family residences. The southwestern portion of the site contains a small area of steep slopes. Access to the proposed lots
would be via a new street off of S 55th Street; a secondary access for emergency vehicles is also proposed.
A. ENVIRONMENTAL IMPACT (e.g. Non -Code) COMMENTS
Element of the Probable Probable More
Environment Minor Major information
Impacts Impacts Necessary
Earth
Air
WOW
Plants
Land/Shoreline Use
Animals
Environmental Health
Energy/
Natural Resources
J -e—
8. POLICY -RELATED COMMENTS
C. CODE -RELATED COMMENTS
Element of the Probable Probable More
Environment Minor Major Information
Impacts Impacts Necessary
Housing
Aesthetics
Li ht/Glore
Recreation
utilities
Transportation
Public Services
Historic/Cultural
Preservation
Airport Environment
10,000 Feet
14,000 Feet
A161, Al/ f? --
r
We have reviewed this application with particular attention to those areas in which we have expertise and have identified areas of probable impact
or areas where additional information is needyd to properly os,ess this proposal.