Loading...
HomeMy WebLinkAboutR-397001UTILITY CONFLICT NOTE O THE CONTRACTOR SHALL BE RESPONSIBLE FOR VERIFYING THE LOCATION, DIMENSION, AND a) DEPTH OF ALL EXISTING UTILITIES, WHETHER SHOWN ON THESE PLANS OR NOT, BY Oa) POTHOLING THE UTILITIES AND SURVEYING THE HORIZONTAL AND VERTICAL LOCATION PRIOR TO CONSTRUCTION. THIS SHALL INCLUDE CALLING UTILITY LOCATE @ 1-800424-5555 AND THEN POTHOLING ALL EXISTING UTILITIES AT LOCATIONS OF NEW UTILITY CROSSINGS TO PHYSICALLY VERIFY WHETHER OR NOT CONFLICTS EXIST, LOCATIONS OF SAID UTILITIES AS SHOWN ON THESE PLANS ARE NOT GUARANTEED AND ARE SUBJECT TO VARIATION. IF W CONFLICTS SHOULD OCCUR, THE CONTRACTOR SHALL CONSULT AP CONSULTING ENGINEERS F. PLLC TO RESOLVE ALL PROBLEMS PRIOR TO PROCEEDING WITH CONSTRUCTION. SHARED MAINTENANCE AGREEMENT NOTE: THE PLAT THAT EXECUTES A SHARED MAINTENANCE AGREEMENT FOR EQUAL Q OWNERSHIP AND MAINTENANCE RESPONSIBILITIES FOR IMPROVEMENTS IN TRACT A. n rr O 25' TRACT A () 5- Q W w Iz 0 Iz rr W Cm G z �I W W PER DETAIL 11C3 - . A SHARED DRIVEWAY C1 NTS ALL UTILITY LINES SERVING THE PROPOSED DEVELOPMENT MUST BE UNDERGROUND. ALL FRANCHISE UTILITIES REQUIRE A SEPARATE FRANCHISE PERMIT. CONSTRUCTION OF THESE FRANCHISE UTILITIES MUST BE INSPECTED AND APPROVED BY A CITY OF RENTON INSPECTOR. S88a04'46"E 370.28' _ FOUND MON IN CASE AT THE INTER. OF SE 164th ST & 109th AVE co SE = oN Id < o rn m w z -I r w 0 0- V) Q w I I II 1` J \ Sheet Number \o, C1 �o \ C2 \ C3 C4 d y0 C5 \ C6 C7 d �0 L1 L2 \ J \ Sheet Number \o, C1 �o \ C2 \ C3 C4 d y0 C5 \ C6 C7 d �0 L1 L2 \ L3 AREAS NOTE: PROPERTY 37,400 SQ FT 0.86AC DISTURBED AREA 9,107 SQ FT 0.21AC FILL =130 CY CUT = 58 CY PARCEL 0088000890 \ PROJECT ADDRESS 1 036 SE 164TH ST, 1 0936 ENTON, WA 98055 \ GROSS ON -SITE IMPERVIOUS AREA 6,169 SQ FT 0.14 AC NET NEW IMPERVIOUS AREA 3,916 SQ FT 0.09 AC \ OFF -SITE IMPERVIOUS (GRAVEL SHOULDER)1,740 SQ FT 0.04 AC IMPERVIOUS SURFACE COVERAGE BASED ON GROSS IMPERVIOUS AREA 7.5% (LOT 1) ; 47.3 (LOT 2) BUILDING COVERAGE 5.8% (LOT 1) ; 46.8% (LOT 2) BUILDING SIZES 1,749 SF (LOT 1) ; 2,381 SF (LOT 2) \ PARKING COUNT N/A NET DENSITY 2.47 DU/AC \ ZONING R-8 \ MAX LOT COVERAGE 2,545 SQ FT (50%) MAX IMPERVIOUS SURFACE AREA 19,693 SQ FT (65%) (LOT 1) ; 3,308 SQ FT (65°%) (LOT 2) \SETBACKS 20 FT FRONT; 20 FT REAR; 5 FT SIDE WEST 85 FEET OF THE EAST 471.64 FEET MEASURED ALONG THE SOUTH LINE OF TRACT 5, BLOCK 10 , AKER'S FARMS NO. 6, ACCORDING TO THE PLAT THEREOF RECORDED IN VOLUME 42 OF PLATS, PAGE 15, RECORDS OF KING COUNTY , ` WASHINGTON. / / \ 30298.27 SQ FT 0.70 ACRES r M N I a \ O �- �I 16 -� 7.6, bK 1 7.8' APPLE / 8 68"AP ( 7 ' 8.'r APPL 1 6 5T APPL g I 6.Y;PPL 87 APPL 1 IC, I` LOT 1 ( I ''"�"ER �o z Q`��'� DATE OF SURVEY: MAY 2016 ( I r co �QP� Q BASIS OF BEARING: PLAT OF AKER'S FARM NO.6 VOLUME 42, PAGE 15. rn I aGo o SE 164th STREET (N 88°04'46"W) BENCHMARK: CITY OF RENTON MON # 1640 o I z Y NE CORNER OF SEC 29-23-05 AT THE o INTERSECTION OF SE 160th ST AND 116th AVE SE 000 12.3' FOUND 3" BRASS DISK WITH PUNCH IN CASE CD} s I ELEVATION = 466.08 (NAVD 88) SITE BENCHMARK: EXISTING SS MH AT THE SOUTHWEST CORNER \ OF THE SITE. EXG GRAVEL DIMI ELEVATION = 428.75 NAVD88 1,749 SIF TRACT A: SHARED D/W PER SECTION AIC1 I : EXG BUILDING -- - - � - 00 I 36.2' \ I \\ \ o .:•-�25.01 o \EXG �I 1 ..•.• . -.. 60.0' BUILDING i RACT A 2117.16SQFT 0 o 0.05 ACRES :. :. ---------------N --- as -- 4 -..73' $.26t 1 LOT 2 8.0' PROPOSED STORM 5090.08 SQ FT I EASEMENT l :5.0 I 0.12 ACRES ' I PRIVATE 16.0' ' PROPOSED HOUSE ' EXG ROCK WALL PROPOSED ACCESS & UTILITY TRACT : .' 1 FRONTAGE IMPROVEMENT :::: :: 250' �L-________ __ ------ SEE SHEET C4 60.0 0 H P 6tiP JMV wc_ L EXG SSMH - I M EL: 428 3� -: . ::. :: :: :::..:..: .:: NEII F :::.::::. NEVICT. : IN EL E,W: 415.:T::-` SAFE WALKING ROUTE IMPROVEMENT ------ SEE SHEET C7 :: :: :: :: :: ::- ::�::: ::: :::-:::•:::•::::: �: :::•:::•:: :: :: : :: :: �: .:::.:. SAFE WALKING ROUTE IMPROVEMENT SEE SHEET C7 cn 0 N = o Ili SITE PLAN c. M 1 =30' W E SURVEYED: DESIGNED: KL S DRAWN: KL CHECKED: AEP NO. REVISION BY DATE APPR A►'PROVE CITY OF RENTON MON #1640 NE CORNER OF 29-23-05 FOUND 3" BRASS DISK W/PUNCH IN CASE AT THE INTER 116th AVE SE & SE 160th STREET N-170648.98 E-1305835.75 FOUND MON IN CASE AT THE INTER. OF SE 164th . ST & 109th AVE SE : EXG SSMH: s RItv� EL: 442.52 IN EL W: 431.27 CITY OF RENTON MON #1863 - E 1 /4 OF 29-23-05 FOUND COPPER PIN IN CASE AT THE INTER 116th AVE SE & SE 168th STREET CURRENT PLANNING N-167989.62 E-1305752.85 Matt Herrera [DateL+j ] CITY OF RENTON Planning/Building/Public Works Dept. SCALE: SHEETINDEX Sheet Title SITE PLAN TESC PLAN GRADING, DRAINAGE & UTILITIES PLAN FRONTAGE IMPROVEMENT PLAN - SE 164TH ST STANDARD DETAILS STANDARD DETAILS 164TH ST SAFE WALKING ROUTE PLAT PLAN TREE RETENTION / LANDSCAPING PLAN TOPOGRAPHY MAP LEGEND DESCRIPTION NEW EXISTING STORM SEWER D - - - D - - - SANITARY SEWER S - - _S_ WATER W - - - W - - - CONTOURS 50 - 50 - - SILT FENCE F POWER (OHP/UGP) - OHP/UGP - - OHP/UGP ASPHALT PAVING ® t• • • • • • • .l PERVIOUS CONC. CONC. PAVING GRAVEL SURFACE LANDSCAPING CONCRETE CURB -- SPOT ELEVATIONS �"" "" """" PARKING COUNT O FOUND CASE MON B FIRE HYDRANT Y GAS METER 0 0 GUY WIRE ANCHOR E- JUNCTION BOX m ❑ PARKING LOT LIGHT POWER POLE W/TRANSFORMER 0 POWER VAULT a a ROCKERY CA" c1� SIGN T SIGNAL POLE STORM CATCHBASIN ■ ❑ STREET LIGHT TELEPHONE JUNCTION BOX ❑ TELEPHONE VAULT OT 111 UNDERGROUND POWER UTILITY POLE -0- UTILITY MANHOLE 0 0 WATER METER in EB WATER VALVE 0.4 N SCALE ONE INCH AT FULL SCALE IF NOT ONE INCH SCALE ACCORDINGLY VERTICAL: NAVD 1988 HORIZONTAL• NAD 1983/1991 DATUM e.g S Spd mg ['roods y5 � 4 9a �c 4Riia Aid O a Pima Medical to P 5 15th St A� 0 N+s 5 16th St 517th St N m S 181h S, p h ya S lgth St ao t] Pizza .;me c 5?151 S1 ABBREVIATIONS: r. 1d u °ty�. t catitarR'dr Q r �s SE Ifith M Phoenix Monressorl - 5 lath St Ludy Fumitwe aQ Oz^Z rpo Ro91ng�•� G ''A r, St > 4 SE ztsa se 1 .. M -pq/SE 2: O SE M Pi O PROJECT SITE 5F 1 2 xt 5t SE,62nd St r K, v ;h St 5E 164th <z VICINITY MAP BLC BUILDING CORNER MJ MECHANICAL JOINT C COMPACT OH OVERHEAD CB CATCH BASIN PL PROPERTY LINE CL CLASS R RADIUS CO CLEAN OUT REF REFERENCE DRAWING COR CITY OF RENTON RIW RIGHT-OF-WAY D STORM DRAIN S - SANITARY SEWER DDCV DOUBLE DETECTOR CHECK VALVE SQ FT SQUARE FEET DI DUCTILE IRON STD - STANDARD DS DOWNSPOUT S/W - SIDEWALK DTL DETAIL T TELEPHONE D/W DRIVEWAY TIC - TOP OF CURB EL ELEVATION TP - TEST PIT ESMT EASEMENT TV TELEVISION EXG EXISTING U.N.O UNLESS NOTED FD FOUNDATION DRAIN OTHERWISE FDC FIRE DEPARTMENT CONNECTION YL YARD LIGHT FF FINISHED FLOOR S SOUTH FHY FIRE HYDRANT W - WEST FL FLANGE JOINT E EAST H/C HANDICAP N NORTH IE INVERT ELEVATION NW NORTHWEST LF LINEAR FEET SW SOUTHWEST US LANDSCAPING NE NORTHEAST MH MANHOLE SE SOUTHEAST 0 - DIAMETER SOUND BUILDING & CONSTRUCTION 26859129TH AVE SE KENT, WA 98030 PH: 206.790.5385 SURVEYOR TOLIMA ENGINEERS & LAND SURVEYORS 255 SW 41ST STREET RENTON, WA 98057 PH: 425.251.0665 ENGINEER ADAM E. PAUL, PE AP CONSULTING ENGINEERS PLLC PO BOX 162 AUBURN, WA 98071 PH: 253.737.4173 APCE@APCONSULTINGENGINEERS.COM LANDSCAPE ARCHITECT BRADLEY DESIGN GROUP, INC 4330 N LEXINGTON STREET TACOMA, WA 98407 PH: 253.272.4848 UTILITIES: WATER: SOOS CREEK WATER AND SEWER DISTRICT SEWER: SOOS CREEK WATER AND SEWER DISTRICT c� o a < z m F---i a E--� r T j Z `14 o LU wL �^ �W Z W M L J cn LO O LO Uwe E W L COAL MINE HAZARD NOTE A COAL MINE HAZARD EXISTS ON THE PROJECT SITE. R-397001 IN COMPLIANCE WITH CITY OF RENTON STANDARDS 0 c.� L U a a DEVELOPMENT ENGINEERING � SURFACE WATER UTILITY Q Ann Fowler 08/01 /2018 rstraka 08/03/2018 J REGIONAL FIRE AUTHORITY Et+Tp L� CURRENT PLANNING APPROVED z (�^ 4ngelea Weihs 08/13/2018 cthomas 08/16/2018 yq(FIRE pis O LALLY'S SHORT PLAT SITE PLAN COVERSHEET 77 DATE* 08/03/2017 (n W RELDBOOK: BOOK PAGE: PAGE DRAWING NO: C1 Q SHEET: OF: 1 7 R-397001