MANHOLE FRAME AND COVER
SEE STD. PLAN 401
ADJUSTMENT RINGS (2" MIN.)
SEE NOTE 6
MORTAR :JOINT(S} (3/8" MIN.)
SEE NOTE 5
CONE (ECCENTRIC)
RUBBER GASKETED JOINTS IN
ACCORDANCE WITH ASTM 0-443
STEPS - POLYPROPYLENE STEPS
SHALL BE INCLUDED
CONCRETE RISER BY PIPE INC.,
OR. APPROVED EQUAL.
LADDER-f OL:YPROPYLENE
SHALL. BE ATTACHED TO MANHOLE
MAX: PIPE SIZE :- "E'
CONCRETE SHELF
PRECAST BASE SECTION
OR CAST IN SHELF.
IA,
"D,
,C,
'D'
,E,
4e MH
4.8"
f;" MIN.
5"MIN
24" MIN,.
54" MH
54
1 8" MIN.
5.5" MIN.
24" MIN,
24" I.D.
SO" MH
60"
1 8" MIN.
6" MIN,
42" MIN.,
30" I.D.
NOTES:
1. STEPS TO BE POLYPROPYLENE SAFETY STEPS.
24 STEPS ARE TO BE IN PLACE BEFORE MANHOLE SECTIONS AREANSTALLEDw
3. CASTING SHALL BE PER STD. PLAN 401.
S 4. MANHOLE SECTIONS TO 8E OF REINFORCED PRECAST CONCRETE.
.5i .ALL JOINTS BETWEEN THE CONE,. RISER RINGS, BRICKS AND CASTING SHALL BE GROUTED.
6. ADJUSTMENT OF THE CASTING TO GRADE SHALL BE ACCOMPLISHED WITH A COMBINATION OF
ADJUSTMENT RINGS, BRICKS AND MORTAR ONLY. BRICKS SHALL BE STAGGERED TO CREATE A RUNNING
BOND OR 1/2 BOND. THE USE OF SHIMS IS PROHIBITED:
7: SANITARY SEWER MANHOLES SHALL HAVE ALL INTERIOR SURFACES, INCLUDING CHANNELING,
COATED (SEALED) WITH A HIGH SOLIDS URETHANE COATING; WASSER MC--AROSH18W OR
APPROVED EQUAL; COLOR OF COATING SHALL BE WHITE.
8; RUBBER GASKETED JOINTS SHALL BE IN CONFORMANCE WITH ASTM C-443.
9. CHANNEL HEIGHT SHALL BE A MINIMUM OF 3/4 OF THE INSIDE DIAMETER OF THE LARGEST PIPE.
10. CONNECTIONS TO MANHOLE SHALL BE MADE USING GPK ADAPTOR, KOR-N-SEAL BOOTS OR
APPROVED EQUAL.
11. IN UNIMPROVED AREAS;: MANHOLES SHALL EXTEND A MINIMUM OF 6" AND A :MAXIMUM OF 12"
ABOVE FINISHED GRADE OR MUST HAVE A MINIMUM 2' DIAMETER CONCRETE RINGS POURED AT GRADE:
IN PAVED AREAS, COVER MUST SLOPE IN ALL DIRECTIONS TO MATCH PAVING.
PUBLIC WORKS . PLAN 4004
DEPARTMENT S"i" SANITARY HOLE
cp SEPTEMBER 2011
tt tf)alEil'�CE�1'%rt�i;`
c tr is T'd rla . it ltaa A . l Tea
��i�T��,�T:��),I��I.
Ip T1110 a
S1'b, PIAN :aop tit
O.D.
limits of pipe
O.D.
L w(see rote 4) �I
3' max.
T m
compaction
r
I limit of pipe zone
bedding
1' - 0°
material
b
for flexible
_
pipe (see
note 6)
0.16 O.D. min.
m
O.D.
limits of pipe
Q
compaction
0.65 O.D. min.
foundation
level
gravel bail _-
--'-®'
gravel backfiil for
-
for pipe bedding
foundations when specified
- -
• A = 4' min. Zr I.D. and under
6° min., over 2T I.D.
A. Metal and Concrete Pipe
Bedding for Flexible Pipes
s an span
Tmi
span 3' max
max
Flexible Pipe NOTES:
.-g°
1. Provide uniform support under barrels.
2. Hand tamp under haunches.
3. Compact bedding material to 95% max: density; directly
N
over pipe, hand tamp only.
0.15 ttae min.
4. See "Excavation and Preparation of Trench" in sanitary
sewers section of the standard WSDOT/APWA
limits of pipe
specifications for trench width "W" and trenching
compai
�0.65 rise min.
options. The pipe zone will be the actual trench width.
The minimum concrete width shall be 1 I I.D. =18".
9 revel bacMll
gravel baddll for
5. Trench backFlll shall conform to "BackFllling Sewer
for pipe bedding
foundations when 5paoieea
Trenches" In the sanitary sewers section of the
WSDOT/APWA standard specifications, except that
rocks or lumps larger than V per foot of pipe diameter
B. Pipe - Arch installation
shall not be used in the backfill material.
6. See "Bedding Material for Flexible Pipe" in aggregates
ndard specifications
section of the WSDOT/APWA standard
for the material specifications.
Rigid Pipe NOTES:
1. Pipe compaction limits shown on this plan are for pipe
construction in an embankment. For pipe construction
in a trench, the horizontal limits of the pipe compaction
zone shall be the walls of the trench.
2. All steel and aluminum pipe and pipe -arches shall be
installed in accordance with design A.
3. Concrete pipe with elliptical reinforcement shall be
installed in accordance with design A.
4. Concrete pipe, plain or with circular reinforcement, shall
be installed with design A.
5. 0. D. is equal to the outside diameter of a pipe or the
outside span of pipe -arch. The dimensions shown as
O.D. with 3' maximum shall be O.D. until O.D. equals
3; at which point T shall be used.
' 1'-0" for diameters 12" through 42" and spans through
50". 2'-0' for diameters greater than 42" and spans
greater than 50".
Backfili material placed in 0.6 loose layers and
compacted to 95% maximum density.
Method B or C compaction (WSDOT/APWA)
standard specifications.)
Pipe
Size
Min. disc.
between
barrels
circular pipe
conc., LCPE, CMP
(diameter)
12" to 24"
12"
30" to 96"
diam. / 2
102" to 180"
48"
pipe - arch
metal only
(span)
18" to 36"
12"
43" to 142"
span / 3
148" to 199"
1 48"
�zY O *�+ PUBLIC WORKS PIP PI STD" P- 220.00
DEPARTMENT DESIGN AND BACKFILL
MARCH 2O08
3"
6"
HOT MIX ASPHALT, CLASS # INCH
FRAME AND VANED GRATE
nfi � '�•
6" OR 12'
ONE #3 BAR HOOP FOR 6" HEIGHT
TWO #3 BAR HOOPS FOR 12" HEIGHT
RECTANGULAR ADJUSTMENT SECTION
A/
#3 BAR EACH CORNEF
#3 BAR EACH SIDE
#3 BAR EACh ..,..
PRECAST BASE SECTION
#3 BAR EACH CORNER
18" MIN
#3 BAR HOOP
PIPE ALLOWANCES
MAXIMUM
PIPE MATERIAL
INSIDE
DIAMETER
REINFORCED OR
12„
PLAIN CONCRETE
ALL METAL PIPE
15,
CPSSP*
12"
(STD. SPEC. M5.20)
SOLID WALL PVC
15"
(STD. SPEC. 9-05.12(1))
PROFILE WALL PVC
15"
(STD. SPEC. 9-05.12(2))
CORRUGATED POLYETHYLENE
STORM SEWER PIPE
NOTES
1. As acceptable altematives to the rebar shown in the PRECAST BASE
SECTION, fibers (placed according to the Standard Specifications), or
wire mesh having a minimum area of 0.12 square inches per foot shall
be used with the minimum required rebar shown in the ALTERNATIVE
PRECAST BASE SECTION. Wire mesh shall not be placed in the
knockouts.
2. The knockout di
r shall not be greater than 20". Knockouts shall
diameter e a
have a wall thickness of 2" minimum to 2.5" maximum. Provide a 1.5"
a
minimum gap between the knockout wall and the outside of the pipe.
After the pipe is installed, fill the gap with joint mortar in accordance
with Standard Specification 9-04.3.
3. The maximum depth from the finished grade to the lowest pipe invert
shall be 5'.
4. The frame and grate must be installed with the flange down.
5. The Precast Base Section may have a rounded floor, and the walls may
be sloped at a rate of 1:24 or steeper.
6. The opening shall be measured at the top of the precast base section.
7. All pickup holes shall be grouted full after the basin has been placed.
8. All grade rings and castings shall be set in mortar in accordance with
Standard Specification 9-04.3.
SEE NOTE 1
ALTERNATIVE PRECAST BASE SECTION
4�y o STD. P - 200.00
PUBLIC WORKS BASINP I
�NTo� DEPARTMENT MARCH 2O08
�- 95% COMPACTED, 1 1 /4"
CRUSHED SURFACING
BASE COURSE, WSDOT
I�IIII�IIIII�IIIII�IIIII�IIIII�II_II
9-03.9(3)
OTE 95% COMPACTED SUBGRADE
1. DEPTHS ARE COMPACTED THICKNESS.
DRIVE AISLE SECT90N
NI°S.
2„
4"
a m1amp. 's
HOT MIX ASPHALT, CLASS INCH
95% COMPACTED, 1 1/4"
_ CRUSHED SURFACING
BASE COURSE, WSDOT
I�IIIIIIIIII�IIIII�IIIII�IIIII�IIII 9_03.9(3)
NOTE 95% COMPACTED SUBGRADE
1. DEPTHS ARE COMPACTED THICKNESS.
I S TION
N.T.S.
Mill
6" FLEXIBLE
PERFORATED
TO INFILTRATIO
TRENCH
PLAN VIEW SUMP WITH SOLID LID
ROOF DRAIN
OVERFLOW WYE
SPLASH BLOCK
FROP TEE
TO INFILTRATION 1' MIN
TRENCH 1' MIN. SUMP
FINE MESH SCREEN 15' MIN.Wi
TYPE 1 CB
SUMP WITH SOLID LID
SEDIMENT CONTROL STRUCTURE
N TS
1 ? I
A
5' R
5'
R
0.50'
TOP OF
D 0.50' I
WALL ELEV.
i
OQ p�
HEIGHT VARIES
VARIES I
SEE SHEET C4.
-_
II
o
' 2.091DEL U1 a
2.07.TYP.
I I
I
/.....................................
i................................:.....::::.::::.::..:
I
.::.:::::..,:::..:.::::::::::::::.:-:-
.....................................................................
.::.:..:.:....:::......:...:....................................:.........................................::::::::::
::... II_
. ......
...................:.....................
- -
-III-III II II II
/����//�����
_
- - - -
-III-III-III-III III
- -
II-�-
I I=1 I I=1 I I-1 I I=1 11=
I I III I I
/�\//��//�✓� CONCRETE CEMENT =�
4 CONCRETE CEMENT
2" CSTC a. l�l
2" CSTC
/
TOP OF WALL ELEV. =1 I - =
BOTTOM OF WALL ELEV,
BOTTOM OF WALL ELEV.
I
WALL NOTES:
HEIGHT VARIES, SEE SHEET
C4.
1) THE WALLS SHOWN ARE FOR
GRADING PURPOSES ONLY.
WALLS OVER 4-FEET REQUIRE
I
I
A BUILDING PERMIT. I FILL
I CUT
2) WALLS OVER 2.5 FEET MUST
PROVIDE A RAILING OR FENCE.
3) RETAINING WALLS ARE LIMITED
TO 6-FEET IN HEIGHT. GENERAL CONCRETE
'WALKWUY [PRIVATE]
3
N.T.S.
COVER VARIES
(1.00' MIN.)
FINISHED GRADE
ELEV. 196.00
ASBUILT RECORD NOTE
THE SHOWN HORIZONTAL AND VERTICAL LOCATIONS OF THE
STORM DRAINAGE AND ROAD SYSTEMS WAS FIELD SURVEYED
BY ME OR UNDER MY DIRECTION, THOSE RELYING ON THIS
RECORD DOCUMENT ARE ADVISED TO OBTAIN INDEPENDENT
VERIFICATION OF ITS ACCURACY BEFORE APPLYING IT FOR ANY
PURPOSE.
WASHED DRAIN ROCK
48LF 6" PERFORATED 1.5"0 TO 0"75"0
ADS N-12 PIPE ® 0.00%
WRAPPED IN GEOTEXTILE I FILTRATION T CH SECT[
FABRIC. NTS
1. CONTRACTOR SHALL EMPLOY REASONABLE MEANS TO AVOID COMPACTION OF THE
INFILTRATION SURFACE, SUCH AS THE USE OF LIGHT TRUCKED EQUIPMENT, DRAGLINES, TRACK
HOES, ETC. THE INFILTRATION AREA SHALL BE FLAGGED OR MARKED WHEN IT HAS BEEN
EXCAVATED TO A DEPTH OF 4 FEET FROM THE FLOOR OF THE INFILTRATION FACILITY TO
KEEP HEAVY EQUIPMENT AND RUBBER TIRED VEHICLES FROM ENTERING THE AREA.
2. AFTER EXCAVATION OF THE INFILTRATION GALLERY TO FINAL DEPTH, CONTRACTOR SHALL
COORDINATE' WITH THE'ENGINEER TO ARRANGE FOR INFILTRATION TESTING. SUFFICIENT TIME
SHALL BE ALLOWED FOR TESTING AND POSSIBLE REVISIONS TO THE GALLERY CON FIGURA11ON
RESULTING THEREFROM.
3. THE TYPE OF FLOW CONTROL BMP IS LIMITED INFILTRATION.
12'
48LF 6" PERFORATED -�
ADS N-12 PIPE ® 0.00% I ILT IO CTI
WRAPPED IN GEOTEXTILE
FABRIC. NTS
CAP END ON PIPE
S-390602