HomeMy WebLinkAboutP_Topography_Plan_181001_v1-0-PTLU
/
/
X 4 5. 0
/ 44.6
EDGE X 44.6
ASPHALT
A_)
43
X 63.1
IE
W. END
/ J � 4" PVC
\ EL = 58.6
X 44.7 44.8
c J TOE
SLOPE / / x CLFNC x
/ TOP]
l' , /SLOP
`V 44.3
63.0
X 44.5
44.2 / / I
O�
N X
/ / = 64.5
�c 62.6
CB
/44.1 /
HVAC
/ Q X 64.7
TBM-B
GREEN
LID
X 44.3
O
x�F\. VERT. PVC 1 64.8
PIPE 00KSW WALL-\
TOE
SLOPE / /
/ TOP
EDGE / SLOPE
ASPHALT /
44.1 �
/61.6 X 62.2
N VICINITY MAP
NOT TO SCALE N 36TH ST
N 35TH ST
JO /
O�
O�
\� N 34TH ST
P�
�r
1
N 89°04'29" W 110.00
X 62.8
BAY WINDOW
z
w
z
Q
Q
W
Y
z
Of
(if
Q
m
G_
N 30TH ST
N 89°04'29" W 92.10'
x x
ro
HOUSE
rl�
0
EAVE LINE
BAY WINDOW
PPU -0- MB
X 68.8
WM
c
- 15.6'-
I/
a
x
0
A
I c
/7.q -
69.8
FINISH FLOOR °
= 71.0 COLUMN d� / w I =
=
c
d 100.6 a d �I 0� L
° r
X ° n L
X
,-f 1° d
GA d o
R AGE 1 z d ° d
d
BAY WINDOW
°I
1-11 GM
�
HOUSE
GM PM
FINISH FLOOR Z A °
= 69.4 Q °
� f a
a LL d° d d d
a (n
1 \`_ d d
1 d d
° 1
A
° 70.5
20'- -
PM G 69.5 -
G
K 70.5 -"- KSW WALL
M
V)
M
I
X 68.9
I
X 69.9
J
W N
I
25.0'
N
TBM-A
71.1
I
N
EDGE
ASPHALT
71.2
U)
4
d
• • 10 20 3#
mom
ASSUMED
DATUM
CONTOUR INTERVAL = 2'
EQUIPMENT & PROCEDURES
FIELD SURVEY CONDUCTED USING A COMBINATION OF GPS USING A
REFERENCE NETWORK AND A 5" ELECTRONIC TOTAL STATION WAS USED
FOR THIS FIELD TRAVERSE SURVEY.
SURVEY PROCEDURES MEET OR EXCEED STATE STANDARDS AS SPECIFIED
BY W.A.C. 332-130 WITH REGARD TO LINEAR AND ANGULAR CLOSURES.
ALL MEASURING INSTRUMENTS FOR THIS SURVEY HAVE BEEN MAINTAINED
ACCORDING TO MANUFACTURES SPECIFICATIONS AND HAVE BEEN
COMPARED WITH A NATIONAL GEODETIC SURVEY CALIBRATED BASELINE
WITHIN THE LAST 12 MONTHS.
BENCHMARKS
ORIGINAL BM: CONCRETE MONUMENT, CITY OF RENTON #1836
ELEV. = 120.03
TBM - A: SET HUB + MAG NAIL.
ELEV. = 70.56
TBM - B: SET PAINT
ELEV. = 62.97
GENERAL NOTES
1. THE INFORMATION DEPICTED ON THIS MAP REPRESENTS THE RESULTS OF
A SURVEY MADE ON THE DATE INDICATED AND CAN ONLY BE CONSIDERED AS
INDICATING THE GENERAL CONDITION EXISTING AT THAT TIME.
2. UNDERGROUND UTILITIES WERE LOCATED BASED ON THE SURFACE
EVIDENCE OF UTILITIES (I.E. PAINT MARKS, SAW CUTS IN PAVEMENT, COVERS,
LIDS ETC.) THE CONTRACTOR SHALL VERIFY THE EXACT LOCATION, ELEVATION
AND SIZE OF EXISTING UTILITIES PRIOR TO CONSTRUCTION.
o N 3. TREE SIZES WERE LOCATED & SPECIES DETERMINED TO THE BEST OF
z OUR ABILITY. HOWEVER, TYEE SURVEYORS DOES NOT WARRANT THE ACCURACY
OF SIZE & SPECIES SHOWN HEREON. ANY TREES CONSIDERED TO BE
CRITICAL SHOULD BE VERIFIED BY A TRAINED ARBORIST.
EJB 2'4 73.3
4. THIS MAP DOES NOT PURPORT TO SHOW EASEMENTS OF RECORD, IF ANY.
I 5. NO PROPERTY CORNERS WERE SET IN CONJUNCTION WITH THIS SURVEY.
w
z
3
71.7 0
w
J
a
w
a
EDGE
173.3 ASPHALT
I
Q
j
m I
PLU
I
FND: 4"X4" CONC.
MON + 1 3/4" BRASS
DISK W/PUNCH, -0.6'
IN CASE
o W
L6 Z
� Q
WIO
W
FND: 4"X4" CONC. w cn
MON +1/8" NAIL W
-0.5' IN CASE o
CITY OF RENTON #1836 z
N: 192137.3027
E: 1300977.6668
EL = 120.03
cn
U)
V)
cn
V)
N
SSMH
N34THST
LEGAL DESCRIPTION
LOT 3, BLOCK 2, C.D. HILLMANS LAKE WASHINGTON GARDEN OF EDEN ADDITION TO
SEATTLE NO. 1, AS PER PLAT RECORDED IN VOLUME 11 OF PLATS, PAGE 63,
RECORDS OF KING COUNTY AUDITOR;
SITUATE IN THE CITY OF RENTON, COUNTY OF KING, STATE OF WASHINGTON.
LEGEND:
CB CATCH BASIN
EJB ELECTRICAL JUNCTION BOX
GM GAS METER
IE INVERT ELEVATION
KSW KEY STONE WALL
MB MAIL BOX
PM POWER METER
PP POWER POLE
PPU POWER POLE W/UNDERGROUND
PTLU POWER POLE W/XFMR&LIGHT&UG
SGN SIGN
SSMH SANITARY SEWER MANHOLE
WM WATER METER
$ CONCRETE HATCH
a°
DECK HATCH
GRAVEL HATCH
OVERHEAD POWER LINE
ROCKERY
6-14-18
PARCEL # 3342100020
NW1 /4, SW1 /4, SEC. 32, T. 24 N., R. 5 E., W.M.