Loading...
HomeMy WebLinkAboutR-399101INDEX TO SHEETS: PM1.01 PAVEMENT MARKING AND R1 OF 20 COVER SHEET SIGNING PLAN rn R2 OF 20 DEMOLITION AND TESC PLAN (OFF -SITE) PM1.02 PAVEMENT MARKING AND c� SIGNING PLAN COVER SHEET FOR o R3 OF 20 DEMOLITION AND TESC PLAN (OFF -SITE) PM1.03 PAVEMENT MARKING AND R4 OF 20 DEMOLITION AND TESC PLAN ( FF SITE) _MEDICINE= VALLEY MEDICALCENTER R5 OF 20 DEMOLITION AND TESC PLAN (ON -SITE) SIGNING PLAN CITY DETAILSUW o PM1.04 PAVEMENT MARKING AND TALBOT ROAD TRAFFIC SIGNAL AND INTERSECTION IMRPOVEMENTS LL_I R6 OF 20 TESC CONSTRUCTION NOTES AND DETAILS SIGNING PLAN -CITY DETAILS R7 OF 20 TALBOT ROAD IMPROVEMENT PLAN AND PM1.05 PAVEMENT MARKING AND PROFILE R8 OF 20 TALBOT ROAD IMPROVEMENT PLAN AND SIGNING PLAN -CITY DETAILS TS1.01 TRAFFIC SIGNAL PLAN CIO PROFILE ~ R9 OF 20 TALBOT ROAD IMPROVEMENT PLAN TS1.02 TRAFFIC SIGNAL PLAN 771 I_I_I R10 OF 20 PEDESTRIAN RAMP DETAILS TS1.03 TRAFFIC SIGNAL PLAN R11 OF 20 PEDESTRIAN RAMP DETAILS WIRE DIAGRAM '-'-I R12 OF 20 NORTH ACCESS ROAD IMPROVEMENT PLAN TS1.04 TRAFFIC SIGNAL PLAN � POLE CHART AND PROFILE o TS2.01 TRAFFIC SIGNAL PLAN R13 OF 20 WATER PLAN -NORTH ACCESS ROAD PLAN FLASHING BEACON AND PROFILE R14 OF 20 CONSTRUCTION NOTES AND DETAILS T82.02 TRAFFIC SIGNAL PLAN 77-1 R15 OF 20 CONSTRUCTION NOTES AND DETAILS FLASHING BEACON p R16 OF 20 CONSTRUCTION NOTES AND DETAILS NOTES AND DETAILS R17 OF 20 CONSTRUCTION NOTES AND DETAILS TS3.01 TRAFFIC SIGNAL PLAN INTERCONNECT SCHEDULE R18 OF 20 CONSTRUCTION NOTES AND DETAILS T84.01 TRAFFIC SIGNAL PLAN L`I R19 OF 20 CONSTRUCTION NOTES AND DETAILS cn T84.02 TRAFFIC SIGNAL PLAN - DETAILS R20 OF 20 SIGNAL FOUNDATION MODIFICATION PLAN T85.01 TRAFFIC SIGNAL PLAN - CITY DETAILS L11 T85.02 TRAFFIC SIGNAL PLAN - CITY DETAILS ~_ SEPA MITIGATION MEASURES T85.05 TRAFFIC SIGNAL PLAN - CITY DETAILS z 1. PROJECT CONSTRUCTION SHALL BE REQUIRED TO COMPLY WITH THE RECOMMENDATIONS FOUND IN THE \ 0 GEOTECHNICAL STUDIES COMPLETED BY GEOENGINEERS INC. FOR THE MEDICAL OFFICE BUILDING (DATED Z SEPTEMBER 16, 2016) AND THE GEOTECHNICAL STUDY FOR THE PARKING GARAGE EXPANSION (DATED AUGUST 2, Q 2016) OR UPDATED REPORTS SUBMITTED AT A LATER DATE. / J 2. THE APPLICANT SHALL VOLUNTARILY CONDUCT ADDITIONAL TRAFFIC ANALYSIS AND SUBMIT AN UPDATED TRAFFIC Q IMPACT ANALYSIS (TIA) FOR THE MEDICAL OFFICE BUILDING (ORIGINALLY PREPARED BY WALKER PARKING z CONSULTANTS- DATED OCTOBER 17, 2016). THE UPDATED TIA SHALL ADDRESS STAFF COMMENTS SENT TO THE APPLICANT ON JANUARY 10, 2017. THE FINDINGS AND RECOMMENDATIONS OF THE UPDATED TIA MAY BE SUBJECT O TO AND INDEPENDENT THIRD PARTY REVIEW AND/OR STUDY AND SHALL COMPLY WITH ANY ADDITIONAL / Cn RECOMMENDATIONS OF A SECONDARY TIA. THE UPDATED REPORT AND THE POTENTIAL SECONDARY ANALYSIS OF TRAFFIC IMPACTS SHALL BE SUBJECT TO APPROVAL BY THE CITY OF RENTON PLAN REVIEW PROJECT MANAGER C) AND THE CITY OF RENTON PUBLIC WORKS TRANSPORTATION DIVISION PRIOR TO CONSTRUCTION PERMIT ISSUANCE. 3. PROJECT CONSTRUCTION SHALL BE REQUIRED TO CONSTRUCT A TRAFFIC SIGNAL AT THE NORTH ACCESS ROAD LL (S 177TH ST & TALBOT RD S) INTERSECTION ALONG WITH ROADWAY IMPROVEMENTS WITHIN THE INTERSECTION TO Q ENSURE THE SAFE AND EFFICIENT FUNCTION OF THE INTERSECTION. THE TRAFFIC SIGNAL AND ROADWAY pC IMPROVEMENTS SHALL BE REVIEWED AND APPROVED BY THE CITY OF RENTON PLAN REVIEW PROJECT MANAGER I� AND THE CITY OF RENTON PUBLIC WORKS TRANSPORTATION DIVISION PRIOR TO BUILDING PERMIT ISSUANCE OF I THE MEDICAL OFFICE BUILDING OR ANY ADDITIONAL TRAFFIC BEING DIVERTED TO OR FROM THIS INTERSECTION. THE MEDICAL OFFICE BUILDING SHALL NOT RECEIVE CERTIFICATE OF OCCUPANCY UNTIL THE NEW TRAFFIC SIGNAL IS Q FULLY TESTED AND OPERATIONAL. I Q) O X 4. ACCESS TO THE NORTH PARKING GARAGE EXPANSION, VIA THE ENTRANCE RAMP THAT EXTENDS OFF THE EAST � DC ELEVATIONS OF PARKING GARAGE, SHALL BE DEVELOPED FOR EMERGENCY ACCESS ONLY ALONG WITH A GATE THAT I J PREVENTS GENERAL VEHICULAR ACCESS FROM TALBOT RD S. THE GATE AND RAMP LOCATION AND ACCESS SHALL z BE SUBJECT TO REVIEW AND APPROVAL BY THE CITY OF RENTON PLAN REVIEW PROJECT MANAGER, THE CITY OF Q RENTON PUBLIC WORKS TRANSPORTATION DIVISION AND THE RENTON REGIONAL FIRE AUTHORITY. THE EMERGENCY m ACCESS GATE MAY BE EXPANDED TO A HOSPITAL STAFF KEY CARD REGULATED READER ACCESS GATE UPON THE J INSTALLATION OF AN OPERATIONAL TRAFFIC SIGNAL AT THE NORTH ACCESS ROAD (S 177TH ST & TALBOT RD S) Q INTERSECTION ALONG WITH ROADWAY IMPROVEMENTS WITHIN THE INTERSECTION. I CONTRACTOR SHALL BE FULLY RESPONSIBLE FOR OBTAINING PERMITS FROM THE v -_ WASHINGTON STATE DEPARTMENT OF NATURAL RESOURCES FOR REMOVING AND Q REPLACING ALL SURVEY MONUMENTATION THAT MAY BE AFFECTED BY CONSTRUCTION 0 w ACTIVITY, PURSUANT TO WAC 332-120. APPLICATIONS MUST BE COMPLETED BY A co F-- REGISTERED LAND SURVEYOR. APPLICATIONS FOR PERMITS TO REMOVE MONUMENTS Z MAY BE OBTAINED FROM THE WASHINGTON STATE DEPARTMENT OF NATURAL Q w RESOURCES, OR BY CONTACTING THEIR OFFICE BY TELEPHONE AT (206) 902-1190. n o U WASHINGTON STATE DEPARTMENT OF NATURAL RESOURCES EX J PUBLIC LAND SURVEY OFFICE DG - 1111 WASHINGTON STREET S.E. o Q P.O. BOX 47060 � CU OLYMPIA, WASHINGTON 98504-7060 I M 0 UPON COMPLETION OF CONSTRUCTION, ALL MONUMENTS DISPLACED, REMOVED, OR DESTROYED SHALL BE REPLACED BY A REGISTERED LAND SURVEYOR, AT THE COST AND AT THE DIRECTION OF THE CONTRACTOR, PURSUANT TO THESE REGULATIONS. THE APPROPRIATE FORMS FOR REPLACEMENT OF SAID MONUMENTATION SHALL ALSO BE THE Q? RESPONSIBILITY OF THE CONTRACTOR. ow J UTILITY CONFLICT NOTE: J Q Q THE CONTRACTOR SHALL BE RESPONSIBLE FOR VERIFYING THE LOCATION, DIMENSION, AND DEPTH OF ALL EXISTING UTILITIES WHETHER SHOWN ON THESE PLANS OR NOT BY POTHOLING THE UTILITIES AND SURVEYING THE HORIZONTAL AND VERTICAL LOCATION PRIOR TO CONSTRUCTION. m THIS SHALL INCLUDE CALLING UTILITY LOCATE AT 811 AND THEN POTHOLING ALL OF THE I EXISTING UTILITIES AT LOCATIONS OF NEW UTILITY CROSSINGS TO PHYSICALLY VERIFY WHETHER OR NOT CONFLICTS EXIST. LOCATIONS OF SAID UTILITIES AS SHOWN ON THESE PLANS ARE BASED UPON THE UNVERIFIED PUBLIC INFORMATION AND ARE SUBJECT TO VARIATION. IF o CONFLICTS SHOULD OCCUR, THE CONTRACTOR SHALL NOTIFY BARGHAUSEN CONSULTING 00 ENGINEERS, INC. TO RESOLVE ALL PROBLEMS PRIOR TO PROCEEDING WITH CONSTRUCTION. w HORIZONTAL CONTROL NOTE: a CONTRACTOR SHALL HAVE ALL PROPERTY LINES, CURB, SIDEWALK, STRUCTURES, CONCRETE PADS � AND ANY OTHER ABOVE GROUND PERMANENT STRUCTURE DEPICTED ON THESE PLANS STAKED co FOR CONSTRUCTION BY A LICENSED SURVEYOR. LICENSED SURVEYOR SHALL STAKE ALL ITEMS co Lij USING COORDINATE GEOMETRY (RECTIFIED TO SITE CONTROL) CONTAINED IN CAD DRAWING FILES e - Ipop II��`,' ice; L 7,­��. Rol 0 y �J / EX BLDG 9 4 u� EX J FOUND MONUMENT IN CASE BLDG // COORDINATE SYSTEM NEW NORTHING: 165,057.54 MEDICAL FASTING: 1,299,413.82 OFFICE BUILDING o� FF=81.0 / r� FF=97.25 \ / \ FOUND MONUMENT IN CASE �<I�I COORDINATE SYSTEM AREA OF NORTHING: 164,722.03 FASTING: 1,299,325.95 CONSTRUCTIONS - vir EX BLDG Q PROVIDED BY BARGHAUSEN CONSULTING ENGINEERS, INC. IT IS THE CONTRACTOR'S RESPONSIBILITY TO RETRIEVE LATEST CAD FILES FROM BARGHAUSEN CONSULTING ENGINEERS INC., Cv+E � REFLECTING ANY ISSUED PLAN REVISIONS. BARGHAUSEN CONSULTING ENGINEERS SHALL _ - IMMEDIATELY BE NOTIFIED OF ANY DISCREPANCIES PRIOR TO THE START OF CONSTRUCTION. - _ " BRASS -DM U CITY OFRENTGN- - H COORDINATE SYSTEM- N 18215 72ND AVENUE SOUTH P�� SqDR EASTING: 1,298,666.96 N KENT, WA 98032 ��OF WASy��� • CD m 2 (425)251-6222 00 Z 0 (425)251-8782 FAX 00 o� �F 24661 00 sG `' CIVIL ENGINEERING, LAND PLANNING, �`/STEM w i �T �� ss/ONA L FAG\ Know what's below. 1 REVISED PER ASBUILT CONDITIONS a �HG ENG�N� SURVEYING, ENVIRONMENTAL SERVICES Z Call before you dig. N0. REVISION 9 22 2020 EXISTING BUILDING SURVEYED: DESIGNED: ZTW DRAWN: ZTW ZTW 2 16 20 ZTW CHECKED: AS BY DATE APPR AlPRavm: AS ily'vFOUND MONUMENT IN CASE COORDINATE SYSTEM NORTHING: 164,295.26 4rEASTING: 1,299,157.79 CITY OF RENTON COORDINATE SYSTEM NORTHING: 164,147.41 EASTING: 1, 299, 099.50 FOUND BRASS ROD IN CASE CITY OF RENTON CONTROL POINT NO. 1229 NORTHING: 163,956.15 EASTING: 1,299,050.25 SCALE: 1 =100, ONE INCH AT FULL SCALE IF NOT ONE INCH SCALE ACCORDINGLY 0 � �o���000�00000000000 unary PROVIDER& SANITARY SEWERS, STORM DRAINAGE, WATER CITY OF RENTON DEVELOPMENT SERVICES 1055 SOUTH GRADY WAY • RENTON, WA 98055 VICINITY M A P I(425) 430-7200 POWER AND NATURAL GAS N NO SCALE I PUGET SOUND ENERGY 411 108TH AVENUE NE PO BOX 97034 BELLEVUE, WA 98009 (425) 454-6363 FAX: (425) 462-3300 TELEPHONE QWEST LDA GROUP PO BOX 625001 LITTLETON, CO 80162 (800) 526-3557 DESCRIPTION: LOTS 1 THROUGH 10 OF VALLEY MEDICAL CENTER NORTH CAMPUS BINDING SITE PLAN, RECORDED IN VOLUME 166 AT PAGES 89 THROUGH 93, INCLUSIVE, IN KING COUNTY, WASHINGTON. FKMONTAL DATUM: NAD 1983/91 - AS PROVIDED BY CITY OF RENTON SURVEY CONTROL NETWORK. REFERENCE VALUES WERE ACQUIRED AND MONUMENTS WERE VISITED IN AUGUST, 2003. REFERENCE CONTROL POINTS ARE AS FOLLOWS: 1227 LOCATION: FOUND A 3/8" BRASS PLUG IN 10" MONUMENT CASE AT A PC ON TALBOT ROAD SOUTH IN THE INTERSECTION OF TALBOT ROAD SOUTH AND SOUTH 45TH PLACE. THERE IS A SIMILAR MONUMENT SOUTH 24° EAST 11.4 FEET. MONUMENT: 3/8 IN BRASS PLUG IN MONUMENT CASE NORTHING: 163,155.0641 EASTING: 1,298,978.216 1229 LOCATION: FOUND 10" MONUMENT CASE AT THE INTERSECTION OF SOUTHWEST 43RD STREET AND TALBOT ROAD SOUTH APPROXIMATELY 10' NORTH OF ANOTHER MONUMENT CASE AT THE PC OF A CURVE ON TALBOT ROAD SOUTH. MONUMENT: MONUMENT CASE NORTHING: 163,956.1484 EASTING: 1,299,050.266 VERITCAL DATUM: NAVD 1988 - AS PROVIDED BY CITY OF RENTON SURVEY CONTROL NETWORK. REFERENCE VALUES WERE ACQUIRED AND MONUMENTS WERE VISITED IN AUGUST, 2003. REFERENCE CONTROL POINT USED: 1892 LOCATION: DOT BRASS DISK SURVEY MARK SET IN A 10" DIAMETER CONCRETE MONUMENT LOCATED AT THE ORILLIA INTERCHANGE EAST OF THE SOUTHWEST 43RD STREET SR 167 UNDERCROSSING, ABOUT HALFWAY TO THE INTERSECTION WITH A TRAFFIC LIGHT CONTROLLING FREEWAY OFF AND ON RAMP TRAFFIC. MONUMENT: WSDOT BRASS DISC IN CONCRETE LOCATED SELY OF SOUTHWEST 43RD STREET OVERPASS OF SR 167 NORTHING: 163,921.58 EASTING: 1,298,126.31 ELEVATION: 84.97 (SEE DRAWING FOR BENCHMARKS SET FOR SITE USE). CIVIL ENGINEER BARGHAUSEN CONSULTING ENGINEERS E DAN BALMELLI. PE, PRINCIPAL 18215 72ND AVE SOUTH KENT, WA 98032 (425) 251-6222 / SHEET R4 ARCHITECT OP NBBJ 223 YALE AVENUE NORTH _ SEATTLE, WA 98109 (206) 621-2314E T T TRAFFIC ENGINEER 1 TENW 11400 SE 8TH STREET, SUITE 200 SHEET KEY MAP BELLEVUE, WA 98004 (425) 250-0582 SCALE: 1 "=200' 00 CIO 0 I c� J !Y IN COMPLIANCE WITH CITY OF RENTON STANDARDS w z LIJ U J U 0 w • CITY OF COVER SHEET 09/27/19 2i VR UW MEDICINE -VALLEY MEDICAL CENTER FlELDBOOK: RENTON TALBOT ROAD INTERSECTION UPGRADES DRAWING NO: '-'-I I Planning/Building/Public Works Dept. 400 SOUTH 43RD STREET RENTON, WA 98055 SHEET: R1 20