Loading...
HomeMy WebLinkAboutT-399110Cn z W W > O rr /� n 2 z O U w C/) rr L L1 z 0 z Q Q z (3 U IL ILL Q 0 Q O O m J Q L L1 z W U J Q U_ 0 L L1 L L1 J J Q > TRAFFIC SIGNAL PLAN - RRFB FOR UW MEDICINE - VALLEY MEDICAL CENTER TALBOT ROAD TRAFFIC SIGNAL AND INTERSECTION IMR.POVEMENTS EX - - - - - 3 S4 S1 2 S2 EX 5' F4 EX 1 1 '- o EX 5.5' 5.5' 10' 5 - RIW - - - - 267 RIW SEE SHEET TS1.01 I I SOURCE LOCATION. I I I I I I I I I I I .I SIGNAL CONSTRUCTION NOTES (THIS SHEET ONLY): 0 CONSTRUCT FOUNDATION PER WSDOT STANDARD PLAN J-21.10 AT STATION 07+43.0, 33.5' RT. FURNISH AND INSTALL BLACK FB SIGNAL POLE (15-FT HEIGHT), BASE, AND CAP. INSTALL TWO 36 "x36" W 1 1-2 SIGNS, ONE 24 "x 12" W 16-7P(R) SIGN, ONE 24"x12" W16-7P L SIGN, ONE W1 1-501 SIGN, ONE CARMANAH TWO-SIDED WRAP AROUND RRFB UNIT WITH PEDSTRIAN VERIFICATION LIG T , ONE CONTROLLER UNIT WITH CABINET AND ONE NEW POLARA MODEL X APS PUSHBUTTON ON THE SIGNAL POLE. SEE POLE 1 DETAIL, SHEET 2.02 FOR CONFIGURATION OF SIGNS AND BEACONS ON THE POLE. PEDESTRIAN PUSHBUTTON SHALL FACE NORTH PARALLEL TO CROSSWALK. CONSTRUCT FOUNDATION PER WSDOT STANDARD PLAN J-20.11 AT STATION 07+37.0, 30.0' LT. FURNISH AND INSTALL BLACK FB SIGNAL POLE (15-FT HEIGHT), BASE, AND CAP. INSTALL TWO 36"x36" W11-2 SIGNS, ONE 24"x12" W16-7P(R) SIGN, ONE 24"x12" W16-7P L SIGN, ONE W1 1-501 SIGN, ONE CARMANAH TWO-SIDED WRAP AROUND RRFB UNIT WITH PEDSTRIAN VERIFICATION LIGHTS, AND ONE NEW POLARA IMODEL X APS PUSHBUTTON ON THE SIGNAL POLE. SEE POLE 2 DETAIL, SHEET 2.02 FOR CONFIGURATION OF SIGNS AND BEACONS ON THE POLE. PEDESTRIAN PUSHBUTTON SHALL FACE NORTH PARALLEL TO CROSSWALK. 3 REMOVE EXISTING POLE AND EQUIPMENT. SALVAGE AND RETURN ALL TO THE CITY OF RENTON SIGNAL MAINTENANCE SHOP. REMOVE FOUNDATION TO A MINIMUM 24" BELOW SURFACE GRADE. COMPACT VOID. SIGNAL GENERAL NOTES o f EX - I v � o i 5.5' - 1. THIS PROJECT SHALL BE CONSTRUCTED PER 2016 WSDOT STANDARD SPECIFICATIONS FOR ROAD, BRIDGE, AND MUNICIPAL CONSTRUCTION, CITY OF RENTON STANDARD PLANS (CURRENT EDITION), AND WSDOT STANDARD DETAILS (CURRENT EDITION). EACH OF THESE DOCUMENTS SHALL BE CONSIDERED PART OF THIS CONTRACT. 2. 3. ALL TRAFFIC SIGNAL AND PEDESTRIAN HEADS AND PUSH BUTTONS SHALL BE SECURELY AND COMPLETELY COVERED WHILE NOT IN OPERATION. 2. JUNCTION BOXES SHALL BE PLACED OUTSIDE OF PAVEMENT SURFACE AND WHEELCHAIR RAMPS UNLESS OTHERWISE INSTRUCTED BY THE ENGINEER. ALL JUNCTION BOXES WITHIN THE PAR/SIDEWALK SHALL USE NON-SKID COVERS PER WSDOT GSP8.20.2(9-29.2(1)A).OPT 1.GR8. 3. ALL WORK SHALL BE IN ACCORDANCE WITH THESE PLANS AND THE CURRENT EDITION OF THE CITY OF RENTON STANDARD SPECIFICATIONS AND DETAILS. THE CURRENT EDITION OF THE CITY OF RENTON STANDARD SPECIFICATIONS AND DETAILS SHALL BE CONSIDERED PART OF THIS CONTRACT. 4. THE LOCATIONS OF FEATURES SHOWN ARE APPROXIMATE AND SHALL BE VERIFIED IN THE FIELD BY THE CONTRACTOR AS NECESSARY. 5. THE CONTRACTOR SHALL SUBMIT A REQUEST TO THE INSPECTOR FOR MATERIALS APPROVAL THREE WEEKS PRIOR TO REQUESTED APPROVAL DATE. 6. ALL WORK SHALL BE CONSISTENT WITH UTILITY AGENCY REQUIREMENTS. THE CONTRACTOR SHALL CONTACT ALL PERTINENT UTILITY AGENCIES 48 HOURS BEFORE COMMENCING WORK, AND SHALL COORDINATE WITH AFFECTED UTILITY AGENCIES THROUGHOUT THE PROJECT. 7. THE CONTRACTOR SHALL BE RESPONSIBLE FOR ANY DAMAGE TO EXISTING UTILITIES. THE CONTRACTOR SHALL NOTIFY THE AFFECTED UTILITY COMPANY AND THE CITY OF RENTON IMMEDIATELY UPON DAMAGE. 8. EXISTING FEATURES TO REMAIN UNLESS OTHERWISE NOTED. 9. ALL CONDUCTORS FOR SIGNAL HEADS, LOOPS, PEDESTRIAN HEADS, PUSHBUTTONS, AND STREET LIGHTS SHALL BE LABELED IN EACH JUNCTION BOX. 10. ALL SIGNALIZED CROSSWALKS SHALL BE OPERATIONAL AT ALL TIMES UNLESS FLAGGERS/POLICE ARE PRESENT TO ASSIST PEDESTRIANS. 11. SALVAGE REMOVED SIGNAL EQUIPMENT TO THE CITY AS REQUESTED, INCLUDING TRAFFIC SIGNAL HEADS, TRAFFIC SIGNAL CONTROLLER CABINET, MAST ARM STREET NAME SIGNS, AND OTHER ITEMS AS REQUESTED. CONTRACTOR SHALL DISPOSE OF ITEMS NOT DESIRED BY THE CITY. 12. CONTRACTOR SHALL PROVIDE TENW WITH REDLINE MARKUPS SHOWING ANY AND ALL CHANGES FROM THESE APPROVED PLANS FOLLOWING CONSTRUCTION. 13. SIGNAL POLE BASE PLATES AND FACE OF PUSHBUTTONS SHALL ALIGN WITH THE BEARING OF THE CROSSWALK IT SERVES. FAILURE TO ORIENT POLES/BASE PLATES WITH THE CROSSWALK WILL REQUIRE THE FOUNDATION TO BE REMOVED AND RE -POURED BY THE CONTRACTOR. SEE SIGNAL POLE PLACEMENT DETAIL SHEET TS2.02. 14. CONTRACTOR SHALL CONFIRM PREFERRED TRENCHING/BORING METHOD WITH CITY OF RENTON PRIOR TO BEGINNING CONSTRUCTION. 15. TRAFFIC SIGNAL, ILLUMINATION AND INTERCONNECT CONDUIT SHALL BE PLACED SUCH THAT IT WILL NOT CONFLICT WITH FUTURE STREET TREE OR STRUCTURE INSTALLATIONS. VERIFY CONDUIT PLACEMENT WITH ENGINEER PRIOR TO BEGINNING CONSTRUCTION. IPTENW Transportation Engineering Northwest Transportation Planning I Design I Traffic Impact & Operations PO Box 65254, Seattle, WA 98155 1 Office (206) 361-7333 Project Contact: Chris Bicket, P.E. Phone: 425-250-5002 "ER••T: B •oF wAj o:14 6'1STE9�P� ONAL•� 07/18/2= _5 23 10' - 1------ 5'------ - F1 - - - I RAW - S1 S3 I I� :EX::jDEWALK I TOOT R- S - -EXR/W _ I EX 5' SIDEWALK RIW SIGNAL WIRING SCHEDULE RACEWAY CONDUIT SIZE FLASH PPB C BEACON PWR #8 EQUIP, GRND. * PULL WIRE CONDUIT FILL ALLOW. FILL NEW NO. 22 2" SCH40 PVC 1 1 0.28 0.890 2" SCH80 PVC 1 1 0.28 0.890 23 2" SCH80 PVC SPARE 1 --- 0.890 24 2" SCH80 PVC 1 2 1 0.45 0.890 2" SCH80 PVC 2 1 0.17 0.890 25 2" SCH80 PVC SPARE 1 --- 0.890 26 2" SCH40 PVC 2 1 0.17 0.890 *EQUIPMENT GROUND SIZE SHALL BE EQUAL TO OR LARGER THAN THE LARGEST WIRE SIZE IN THE CONDUIT. Z 10 40 0 20 60 SCALE IN FEET SIGNAL DISPLAYS EL] ELI] RECTANGULAR RAPID FLASHING BEACON NEW: F1,172,F3,F4 ALL NEW DISPLAYS SHALL BE LED. SIGNAL LEGEND (THIS SHEET ONLY) NEW DESCRIPTION O SIGNAL POLE TYPE FB H POLE MOUNTED SIGN © POLE MOUNTED CONTROLLER CABINET OCONSTRUCTION NOTE ® SIGNAL POLE NUMBER NEW SIGN NOTES (THIS SHEET ONLY) S1 INSTALL ONE (1) 36"x36" W1 1-2 SIGN. INSTALL ONE (1) 24"x 12" W 16-7P(L) SUPPLEMENTAL PLAQUE BENEATH S2 W 1 1-2 SIGN. S3 INSTALL ONE (1) 24"x 12" W 16-7P(R) SUPPLEMENTAL PLAQUE BENEATH W 1 1-2 SIGN. S4 INSTALL ONE (1) 12 "x 12" W 1 1-501 SIGN ABOVE PUSHBUTTON. SIGN LEGEND W 16-7P(L) < 24"x12" > S2 W11-2 36 "x36" W 16-7P(R) S1 24"x12" S3 • W11-501 CROSS TRAFFIC 12 "x 12" MAY NOT STOP S4 USE CAUTION WHEN CROSSING AFFIX R10-25 (9"X12" PER MUTCD) PLAQUE TO PEDESTRIAN PUSHBUTTON ASSEMBLIES PUSH POLARA MODEL X: 2 CT BUTTON TO TURN ON WARNING BACKGROUND : YELLOW LIGHTS TEXT/SYMBOL : BLACK W 16-7P SIGNS SHALL BE FLOURESCENT YELLOW -GREEN WITH BLACK SYMBOLS AND BORDER. W 1 1-2 SIGN SHALL BE FLOURESCENT YELLOW -GREEN WITH BLACK SYMBOLS AND BORDER. SEE POLE DETAILS, SHEET TS-2.02 FOR ADDITIONAL SIGNING REQUIREMENTS. T-3991 010 IN COMPLIANCE WITH CITY OF RENTON STANDARDS TRANSPORTATION OPERATION (Di cbarnes 09/19/2018 SURVEYED: SCALE: VERTICAL: AD HORIZONTAL: NAD 193/183/1 991 DATUM A&W& C TY OF vRRENTON • Planning/Building/Public Works Dept. TRAFFIC SIGNAL PLAN - RRFB UW MEDICINE -VALLEY MEDICAL CENTER TALBOT ROAD INTERSECTION UPGRADES 400 SOUTH 43RD STREET RENTON, WA 98055 DATE: 7/18/18 DESIGNED: J LS FIELDBOOK: PAGE: DRAWN: JLS ONE INCH DRAWING NO: TS2. 1 CHECKED: AT FULL SCALE IF NOT ONE INCH SCALE ACCORDINGLY NO. REVISION BY DATE APPR APPROVED: SHEET: 1 O OF: 1 7 00 M O O Cfl T Q J N O L0 O 0 (0 T 7 C/) z Lu 2 Lu O z O_ U Lu C/) Lu z 0 z Q J Q z 0 C/) U_ IL IL Q 0 Q O O In J Q L L1 z L L1 U J Q U_ 0 L L1 G J >