HomeMy WebLinkAboutMFP18004979DEPARTMENT OF COMMUNITY
AND ECONOMIC DEVELOPMENT
Franchise Permit: MFP18004979
IVR Number: 18004979
Permit Informaon
Permit Name:Century Link Permits
Address/Locaon :09/05/2018Application Date:1623059135Parcel Number:3407 NE 2ND ST
Permit Type:09/14/2018Issue Date:Franchise
Permit Work Class:09/14/2019Expiration Date:Minor Utility
Job Number:N.415367Franchise Type:Telephone
Description:APPROVED WITH COMMENTS OR REDLINES
Century Link to access HH1087, place 2 bore pits, bore 50', trench 52', and overset Century Link ped with a big shot
ped. Pothole all existing utilities. Restoration per City of Renton standards.
Contacts
Name Address PhoneTypeBilling
C/O QWEST CORP 1801 CALIFORNIA ST #4600
Denver, CO 80202
Applicant
Kim Parker
QWest Corporation
931 14th St, Suite 1000A
Denver, CO 80202
B: (303) 992-0752Contact
Heather Binkly
Dycom Industries dba North Sky
11770 Us Hwy 1, SUITE 101
Palm Beach Gardens, FL 33408
B: (360) 254-6920
O: (360) 450-3287
Contractor
Business License Number: 36846Construction Contractor: NORTHSC857Q4
CITY OF RENTON ROW 1055 S Grady Way
Renton, WA 98057-3232
Owner
QWest/Century Link - Billing 7850 S TRAFTON St
TACOMA, WA 98409
Specialized
Billing
X
General Condions & Signature
Permission is hereby given for the work described on this permit according to the conditions hereon and according to the
approved plans and specifications pertaining thereto, subject to compliance with the Ordinance of the City of Renton.
This permit and plans must be posted at the job site at all times.
I hereby certify that no work is to be done except as described above and in approved plans, and that work is to conform to
Renton Trench Restoration and Street Overlay Requirements.
Call (425) 430-7203 or go to: www.MyBuildingPermit.com one working day in advance to schedule an inspections and for ANY
work in the Right of Way.
Call 8 1 1 to locate underground utilities at least two full business days prior to any excavation.
In accordance with RCW 19.122.033(4) the permit holder is required to contact (Williams Northwest Pipeline at 425.868.1010)
(Olympic Pipeline at 206.510.0575) (Puget Sound Energy at 425.375.3397) to request a consultation with the transmission
pipeline company prior to performing any construction or excavation activities. This requirement to consult with the
transmission pipeline company is in addition to the requirement to Call before You Dig as required in RCW 19.122.
(Date)(Signature)
Page 1 of 1THIS PERMIT AND PLANS MUST BE POSTED AT THE JOB SITE AT ALL TIMES
DEPARTMENT OF COMMUNITY
AND ECONOMIC DEVELOPMENT
Page 1 | Published: 3/30/2017
Planning Division | 1055 South Grady Way, 6th Floor | Renton, WA 98057 | 425-430-7200
Email: franchisepermits@rentonwa.gov Website: rentonwa.gov
FRANCHISE PERMIT APPLICATION
Published: 3/30/2017
TO THE APPLICANT: Submit an electronic copy of the plans with the Franchise Permit Application and the
Traffic Control Application to franchisepermits@rentonwa.gov. Permit cost is $360.50. Inspection fee for
trenching more than 60 lineal feet or installation of 6 or more poles will be billed at $60.00 per hour.
Franchise Agency:
Franchise Job Number: Phone:
Contact Name: Email:
Job Site Address: Project Name:
Description of Work:
Please check all that apply:
☐New Construction ☐Repair/Relocate ☐ Underground ☐Overhead ☐Sidewalk ☐Street
☐Open Trench ☐ Bore # of feet:
Contractor Name: Phone:
State Contractors License #: City of Renton Business License #:
“I certify that I am the owner or applicant’s authorized agent and do hereby agree to abide to the terms and conditions set forth under this permit and shall comply with the City of Renton’s Trench Restoration and Street Overlay Requirements. ”
Signature Date
INSPECTIONS SHALL BE REQUESTED 24 HOURS PRIOR TO COMMENCEMENT OF ALL WORK BY CALLING THE
INSPECTION LINE AT 425-430-7203 OR BY GOING TO MYBUILDINGPERMIT.COM
Jobs are required to be called in for job start, re-inspection and project final. Re-inspection fees are billed at $75/hour.
All Pre-Construction meetings shall be scheduled at a maximum of 14 days prior to the job start date.
Plan Review/Development Engineering Date Approved as submitted
Pre-Construction Meeting required
Site Construction Inspector Date Approved with comments or redlines
Camera inspection of utilities required
Development Engineering Manager Date
Amy Silbaugh
Qwest Corp d/b/a CenturyLink
N.415367
Amy Silbaugh
253-372-5311
amy.silbaugh@centurylink.com
3407 NE 2nd St
CenturyLink to access HH1087, place 2 bore pits, bore approx. 50', trench a total
of approx 52', and overset CTL ped with a Big Shot Ped. Disturbance of surface to be restored to
the city of Renton standards.
102'
North Sky Communications 260-254-6920
NORTHSC857Q4 BL.028638
09/05/2018
MFP18004979
Scott Warlick 9/6/2018
POTHOLE ALL EXISTING UTILITIES
Holly Powers 9/14/2018
NE 2ND ST
NO OUTLE
T
NO OUTLETMONROE AVE NEACCESS RDTRAFFIC CONTROL PLAN
JOB # N.415367.C.45
PERMIT #
Designed for: CENTURYLINK
Project # N.415367.C.45
Darlene Durr
Traffic Control Supervisor
TCS # 008900 EXP. 4/30/19
Approved 9/4/18
Phone 253-737-5198
darlene.durr@hotmail.com
_______________________
Date:9/4/18 Author:Darlene Durr, Traffic Control Supervisor Project:N.415367.C.45
CERT:TCS # 008900 EXP 4/30/19 CENTURYLINK:Certified Traffic Control Plan (DO NOT ALTER)
Comments:
General Requirements
1. All signs and spacing to conform to the MUTCD and City of RENTON requirements.
2. Channelizing devices are 28" traffic cones with retro reflective material.
3. All signs are 48' X 48' B/O unless otherwise specified.
4. Alert affected local residents and businesses.
5. Crew is required to leave a minimum 11' for lane width.
6. Work hours will be ____am to ____pm.
Legend
WORK TRUCK
WORK AREA
CONES
FLAGGER
Plan Scale
1 : 1536 (1'' = 128')NOT TO SCALE
UNLAWFUL FOR ANYONE OTHER THAN THE CITY OF RENTON TO
ALTER THIS CERTIFIED TRAFFIC CONTROL PLAN
IN ANY FORM WITHOUT EXPRESS WRITTEN CONSENT FROM:
DARLENE DURR, TCS #008900, darlene.durr@hotmail.com
Comments:
CHANNELIZATION SPACING
MPH TAPER TANGENT
35 / 45 30' 60'
25 / 30 20' 40'
ONE LANE TWO WAY
TAPER 50' TO 100' MAX
ONE LANE TWO WAY TAPER 50' MIN/100' MAX CITY USE ONLYPRINTER SETTINGS: PAGE SIZE 8.5" X 11"/ ADVANCED: FIT TO 11" X 17" FOR CITY USE3407
NE 2ND ST BORE
PIT #2
NEW BIG SHOT
PEDESTAL
PLACEMENT
TRENCH
WORK AREA
+/- 22'
BORE
PIT #1
TRENCH
WORK AREA
+/- 30'
HH 1087
BORE
WORK AREA
+/- 50'18'18'WORK AREA
10' X 80'
WORK AREA
10' X 80'
ROAD
WORK
AHEAD
W20-1 ROADWORKAHEADW20-1ROADWORKAHEADW20-1ROADWORKAHEADW20-1ONE LANEROADAHEADW20-4W20-7aONE LANEROADAHEADW20-4W20-7a200'
200'
200'
200'200'200'
200'
SPEED
LIMIT30
N
NE 2ND ST @ MONROE AVE NE
BORE & TRENCH / NEW BIG SHOT PLACEMENT / RESTORE
ONE LANE TWO WAY WITH FLAGGERS
Comments:
THIS IS TO BORE & TRENCH FROM HH 1087 LOCATED IN THE NORTH SIDE OF NE
2ND ST EAST OF MONROE AVE NE TO 3407 NE 2ND ST LOCATED IN THE SOUTH
SIDE OF NE 2ND ST EAST OF MONROE AVE NE, PLACE NEW BIG SHOT AT EXISTING
PEDESTAL AND RESTORE AS REQUIRED.
THIS IS A ONE LANE TWO WAY WITH FLAGGERS OF NE 2ND ST EAST OF MONROE
AVE NE.
FLAGGERS WILL ASSIST WITH DRIVEWAYS AND PEDESTRIANS AT WORK AREA.VICINITY MAP
3407 NE 2ND ST
50'
50'
www.invarion.com
MFP18004979
NOTICE-NOT FOR DISCLOSURE OUTSIDE OF CENTURYLINK AND AFFILIATES EXCEPT UNDER WRITTEN AGREEMENTJOB:SH OF BEFORE YOU DIG811CALL TWO WORKING DAYSRNGE:SECT:TOWN:GEO CODE:WC CLLI:TOTAL EXISTING CONDUIT USED:TOTAL NEW BORE:TOTAL NEW DIRT TRENCHESTIMATED TOTALSTOTAL NEW AERIAL:SIDEWALK (PCC) R&R:ASPHALT (AC) R&R:S.F.S.F.L.F.L.F.L.F.L.F.TOTAL NEW ASPHALT TRENCH:L.F.TOTAL NEW S/W TRENCH:L.F.0505200000”NVICINITY MAP5%12'1(914-POF: @ HANDHOLE 1087 SPLICE COUNT LRE16, 15-16 TO NEW 24 FIBER. PLACE NEW 1-2" CONDUIT, 24FIBER & 1" INNERDUCT APPROX. 134' ACROSS NE 2nd STREET, THEN CONTINUE TO CUSTOMER'S BUILDING.%7561/'40#/'4'06106'%*0+%#.%1..')'.%102#7.4#-'.2*10'01
Ä'/#+.RTCMGN"TVEGFW241,'%6+&5&54+&&54/6.6&'0)+0''4%14;%1#6'2*10'01
Ä'/#+.EEQCVGOVP"IOCKNEQODRAFTED BY: MOUNTAIN LTD/SL 08/28/1823N5E16N.415367W26226RNTNWA013407 NE 2ND STREETRENTON, WA 9805613(+$'4'0)+0''4#.':41)'452*10'01
Ä'/#+.CNGZTQIGTU"EGPVWT[NKPMEQOMFP18004979
TTEE CATV CATV CATV GG TS TS WW S S SD SD IRRIG IRRIG C/L C/L R/W R/W R/W P/L P/L B/C B/C B/C EOP EOP TTTUSAMEEPWREETVTVVTSVWSSDVETTTXXX'XXX'XXX'XXX'XITEM #STATIONHT-CL-YRPROPOSED HOAPOLE NUMBER(S) - CTL/PWR/OTHERITEM#STAHT-CL-YRXX'-X"POLE#MAKE READYEXISTING ATTACHMENTSNOTICE-NOT FOR DISCLOSURE OUTSIDE OF CENTURYLINK AND AFFILIATES EXCEPT UNDER WRITTEN AGREEMENTJOB:SH OF RNGE:SECT:TOWN:GEO CODE:WC CLLI: BEFORE YOU DIG811CALL TWO WORKING DAYS/6.6&'0)+0''4%14;%1#6'2*10'01
Ä'/#+.EEQCVGOVP"IOCKNEQODRAFTED BY: MOUNTAIN LTD/SL 08/28/1823N5E16N.415367W26226RNTNWA013407 NE 2ND STREETRENTON, WA 9805623(+$'4'0)+0''4#.':41)'452*10'01
Ä'/#+.CNGZTQIGTU"EGPVWT[NKPMEQOMFP18004979
NOTICE-NOT FOR DISCLOSURE OUTSIDE OF CENTURYLINK AND AFFILIATES EXCEPT UNDER WRITTEN AGREEMENTRNGE:SECT:TOWN:JOB:SH OF GEO CODE:WC CLLI: BEFORE YOU DIG811CALL TWO WORKING DAYS016'(1470&'4)4170&#%6+8+6;6'56#0&8'06+.#6'/#0*1.'76+.+6;8#7.624+1461'064;2.#%'9#40+0)&'8+%'5#0&914-#4'#2416'%6+10#54'37+4'�&75'';'#0&*'#&5#('6;2416'%6+102'4('&'4#.56#6'#0&.1%#.4')7.#6+105/6.6&'0)+0''4%14;%1#6'2*10'01
Ä'/#+.EEQCVGOVP"IOCKNEQODRAFTED BY: MOUNTAIN LTD/SL 08/28/1823N5E16N.415367W26226RNTNWA013407 NE 2ND STREETRENTON, WA 9805633(+$'4'0)+0''4#.':41)'452*10'01
Ä'/#+.CNGZTQIGTU"EGPVWT[NKPMEQO EOP EOP EOP EOP EOP EOP EOP EOP EOP EOP EOP EOP EOP C/L C/L C/L C/L C/L C/L C/L C/L C/L EOP EOP EOP EOP R/W R/W R/W R/W R/W R/W R/W R/W R/W R/W R/W R/W R/W R/W R/W R/W R/W R/W R/W 36'60'50'0'PF564''65+&'9#.-2.#06'4.#0&5%#2'.#0&5%#2'
18'45'6%6.2'&9$+)5*162'&T28'29'
:$14'2+6
:$14'2+6
21(%6.**016'TRENCH FOR 30' OF NEW1-2" CONDUIT, 24 FIBER &1" INNERDUCT WITHRESTORATION.016'@ HANDHOLE 1087 SPLICE COUNTLRE16, 15-16 TO NEW 24 FIBER.016'BORE FOR 50' OF NEW 1-2" CONDUIT,24 FIBER & 1" INNERDUCT WITHRESTORATION.016'TRENCH FOR 22' OF NEW 1-2"CONDUIT, 24 FIBER & 1" INNERDUCTTO TIE INTO CUSTOMER'S CBO 2"WITH RESTORATION.016'EXISTING 1-3" DUCT.REPLACE LB JOINTW/24"X24" PULLBOX.016'30' OF 1-1" INNERDUCT.016'2" CBO CONDUIT.4/%7565'48'44/4/016'CUSTOMER TOPLACE 2" DUCTTHRU WALL 6".016'5CTL TO TRENCH FOR 52' OF NEW 1-2" CONDUIT.CTL TO BORE FOR 50' OF 1-2" CONDUIT.CUSTOMER TO PLACE 1-24"X24" PULLBOX.CUSTOMER TO PLACE 1-2" CONDUIT THRU WALL 6" TOCREATE PATH TO SERVER ROOM.CTL TO PLACE 134' OF FIBER & 1" INNERDUCT.36'016'OVERSET OLD PEDESTALWITH BIG SHOTPEDESTAL. NO DUCTSVERIFIED.52'0'PF564''6&4+8'9#;
&4+8'9#;574(#%'.'8'.%10&7+636' MIN.574(#%'.'8'.6;2+%#.$14' 64'0%*22'2'#2241:+/#6'.;(41/*#0&*1.'61/1041'#8'0'
%6.**
$14'2+6
64''Ä
'1&Ä
'1&MFP18004979