HomeMy WebLinkAboutP_Design_105088720_V1_180727SHADOW AVENUE NENE 3RD STREET
NE 3RD COURT
ROSARIO PLACE NENE 4TH STREET
336.4ACSR
336.4ACSR
115kV
ABCABCTRACT BTRACT CPLAT OF AMBERWOOD II
105036903
EXISTING HOME
TO REMAIN
(6201)
EX: 1-2"
FUT: 1-2"
FUT: 1-2"
FUT: 2-3"
COORDINATE WITH PSE REGARDING
LOCATION OF CATCH BASINS IN
FRONTAGE EASEMENT
T-MOBILE
CELL TOWER
REMOVE
53'20.5'47'#2 ACSR84'1" = 50'
DESIGNED BY
UTILITIES
CONTACT
PHONE#
COUNTY
1/4 SEC
U-MAP NO (POWER)
OP MAP
Emer Sect Gas Wk Ctr POWER WK CTR
PLAT MAP
JOINT FACILITIES ARRANGEMENTS
DRAWN BY
CHECKED BY
APPROVED BY
FOREMAN #1
FOREMAN #2
MAPPING
INCIDENT MAOP
Gas Order Elect Order
SCALE PAGE
ENGR - POWER
ENGR - GAS
FUNCTION
PROJECT MGR
PERMITREAL ESTATE/EASEMENT
2
1
REV#
3
DATE DESCRIPTIONBY
CONTACT PHONE NO DATE
OH CKT MAP CIRCUIT NOUG CKT MAP
L. BROWN 425.417.8620 5.22.18
S.MARSHALL .5.22.18
S.MARSHALL .5.22.18
E. PASAYE .5.22.18
REDT # ( RW-109364 )RENTON
RENTON 14 PLAT
1Ø PRIMARY U/G LINE EXTENSION - 14 S/F LOTS
6201 NE 4TH ST, RENTON, WA 98059
PUGET SOUND ENERGY
N/A IP 088-60
107056137 105088720
1" = 50'2 OF 4
KING 30 CIKNC QCSOKE
14NW-T23N-R05E 208.086 208.088
2305E054 2306E076 2305E054 MAP-17
COMCAST
DANIEL LAROCHE
253-358-5460
CENTURYLINK
TARYN EHLIG
206-733-8858
RIGHT OF WAY
ALEX E MALESIS
425-462-3436
.
.
.
SITE PLAN
CIRCUIT LOADING TABLE
AS OF
EXIST. PEAK LOAD
EST. NEW LOAD
TOTAL
CIRCUIT:
A PHASE B PHASE C PHASE
MAP-13
6.6.18
162 165 204
N/A N/A 9
162 165 213
...
...
...
SCHED.SQ. FT.
MAX LRC =
CIRCUIT FEET ADDED: 780
27 3500
115 AMPS
THIS SKETCH NOT TO BE RELIED UPON FOR EXACT LOCATION OF EXISTING FACILITIES
CALL (800) 424-5555
2 BUSINESS DAYS BEFORE YOU DIG
For contacts below dial 1-888-CALL PSE (225-5773)
WIRE REMOVAL TABLE
Location
Wire Size & Type Quantity
Length
(per
conductor)RemarksFromTo
P01 P02 #2 ACSR 2 150
300 Total Feet (#2 ACSR) Removed
POLE RETIREMENT TABLE TEMP TRANSFERS ST. LIGHT TRANSFERS
SITE
#
POLE DATA POLE
TEL TV FIBER TRAN RMVD ID NUMBER
GRID #HEIGHT CLASS YEAR TOPPED RMVD
P02 318079-167833 45 3 2018
DEDICATED FACILITIES (105088720) Dedicated Stub Location
SITE SPAN ADDITIONAL REMARKS LABOR UNITS
#FROM TO FOOTAGE
-V02 LOT 10 70 DED. CONDUIT & WIRE 2-36, 2-54A
TOTAL FT=70
CROSSINGS CONDUIT TABLE
X-ING
NO.
LOCATION GAS POWER Length
Remarks (type of crossing)
SIZE Type Qty Location SIZE Type Qty
(Primary, Feeder, Secondary, St.
FROM TO (in)sched each N-S-E-W (in)sched each (ft)Light, Gas Only, etc.)
X01 LOT 14 LOT 12 4 40 1 S 3 SCH80 2 30
SECONDARY, GAS MAIN
2 1 PRIMARY
X02 LOT 14 LOT 13 2 40 1 S 3 SCH80 1 30 SECONDARY, GAS SERVICE
X03 LOT 10 LOT 1 2 40 1 S 3 SCH80 2 65 SECONDARY, GAS SERVICE
X04 LOT 8 LOT 3 2 40 1 N 3 SCH80 1 65 SECONDARY, GAS SERVICE
X05 LOT 5 LOT 4 2 40 1 N 3 SCH80 1 65 SECONDARY, GAS SERVICE
X06 LOT 8 LOT 5 4 40 1 W 2 SCH80 1 60 PRIMARY, GAS MAIN
X07 LOT 5 LOT 8 2 40 1 W 3 SCH80 2 60 SECONDARY, GAS SERVICE
2" PVC PLUG /CAPS = 10 2" YELLOW SCH 40 PVC = 285 FT 2" SCH80 GREY PVC = 90 FT 2" PVC PLUG /CAPS = 4
4" PVC PLUG /CAPS = 4 4" YELLOW SCH 40 PVC = 90 FT 3" SCH80 GREY PVC = 470 FT 3" PVC PLUG /CAPS = 18
DEVELOPER RESPONSIBLE
FOR CONDUIT/WIRE FROM
H1B TO IRRIGATION METER
LOCATION
Removed at site:
Grid Number:
kVA Rating:
Foreman to redline the following information
TRANSFORMER REMOVAL
Company ID#:
Primary phase connected to:
Tested Secondary Voltage
P02
318079-167833
25
SITE SPECIFIC NOTES
AT SITE P02: GRID# 318096-167835
EXIST PSE OWNED 2010 75'CLH3 POLE TO REMAIN
AT SITE P02: GRID# 318082-167834
REMOVE EXIST 2018 45' CLASS 3 POLE & ALL OH EQUIPMENT
SPAN NOTES
P01 TO P02:
REMOVE EXIST #2 ACSR OH PRIMARY ±150'
CABLE REMOVAL TABLE
Location
Cable Size &
Type Quantity
Length
(per
conductor)RemarksFromTo
P02 H2A 4/0 UG TPX 65