Loading...
HomeMy WebLinkAboutP_Design_105088720_V1_180727SHADOW AVENUE NENE 3RD STREET NE 3RD COURT ROSARIO PLACE NENE 4TH STREET 336.4ACSR 336.4ACSR 115kV ABCABCTRACT BTRACT CPLAT OF AMBERWOOD II 105036903 EXISTING HOME TO REMAIN (6201) EX: 1-2" FUT: 1-2" FUT: 1-2" FUT: 2-3" COORDINATE WITH PSE REGARDING LOCATION OF CATCH BASINS IN FRONTAGE EASEMENT T-MOBILE CELL TOWER REMOVE 53'20.5'47'#2 ACSR84'1" = 50' DESIGNED BY UTILITIES CONTACT PHONE# COUNTY 1/4 SEC U-MAP NO (POWER) OP MAP Emer Sect Gas Wk Ctr POWER WK CTR PLAT MAP JOINT FACILITIES ARRANGEMENTS DRAWN BY CHECKED BY APPROVED BY FOREMAN #1 FOREMAN #2 MAPPING INCIDENT MAOP Gas Order Elect Order SCALE PAGE ENGR - POWER ENGR - GAS FUNCTION PROJECT MGR PERMITREAL ESTATE/EASEMENT 2 1 REV# 3 DATE DESCRIPTIONBY CONTACT PHONE NO DATE OH CKT MAP CIRCUIT NOUG CKT MAP L. BROWN 425.417.8620 5.22.18 S.MARSHALL .5.22.18 S.MARSHALL .5.22.18 E. PASAYE .5.22.18 REDT # ( RW-109364 )RENTON RENTON 14 PLAT 1Ø PRIMARY U/G LINE EXTENSION - 14 S/F LOTS 6201 NE 4TH ST, RENTON, WA 98059 PUGET SOUND ENERGY N/A IP 088-60 107056137 105088720 1" = 50'2 OF 4 KING 30 CIKNC QCSOKE 14NW-T23N-R05E 208.086 208.088 2305E054 2306E076 2305E054 MAP-17 COMCAST DANIEL LAROCHE 253-358-5460 CENTURYLINK TARYN EHLIG 206-733-8858 RIGHT OF WAY ALEX E MALESIS 425-462-3436 . . . SITE PLAN CIRCUIT LOADING TABLE AS OF EXIST. PEAK LOAD EST. NEW LOAD TOTAL CIRCUIT: A PHASE B PHASE C PHASE MAP-13 6.6.18 162 165 204 N/A N/A 9 162 165 213 ... ... ... SCHED.SQ. FT. MAX LRC = CIRCUIT FEET ADDED: 780 27 3500 115 AMPS THIS SKETCH NOT TO BE RELIED UPON FOR EXACT LOCATION OF EXISTING FACILITIES CALL (800) 424-5555 2 BUSINESS DAYS BEFORE YOU DIG For contacts below dial 1-888-CALL PSE (225-5773) WIRE REMOVAL TABLE Location Wire Size & Type Quantity Length (per conductor)RemarksFromTo P01 P02 #2 ACSR 2 150 300 Total Feet (#2 ACSR) Removed POLE RETIREMENT TABLE TEMP TRANSFERS ST. LIGHT TRANSFERS SITE # POLE DATA POLE TEL TV FIBER TRAN RMVD ID NUMBER GRID #HEIGHT CLASS YEAR TOPPED RMVD P02 318079-167833 45 3 2018 DEDICATED FACILITIES (105088720) Dedicated Stub Location SITE SPAN ADDITIONAL REMARKS LABOR UNITS #FROM TO FOOTAGE -V02 LOT 10 70 DED. CONDUIT & WIRE 2-36, 2-54A TOTAL FT=70 CROSSINGS CONDUIT TABLE X-ING NO. LOCATION GAS POWER Length Remarks (type of crossing) SIZE Type Qty Location SIZE Type Qty (Primary, Feeder, Secondary, St. FROM TO (in)sched each N-S-E-W (in)sched each (ft)Light, Gas Only, etc.) X01 LOT 14 LOT 12 4 40 1 S 3 SCH80 2 30 SECONDARY, GAS MAIN 2 1 PRIMARY X02 LOT 14 LOT 13 2 40 1 S 3 SCH80 1 30 SECONDARY, GAS SERVICE X03 LOT 10 LOT 1 2 40 1 S 3 SCH80 2 65 SECONDARY, GAS SERVICE X04 LOT 8 LOT 3 2 40 1 N 3 SCH80 1 65 SECONDARY, GAS SERVICE X05 LOT 5 LOT 4 2 40 1 N 3 SCH80 1 65 SECONDARY, GAS SERVICE X06 LOT 8 LOT 5 4 40 1 W 2 SCH80 1 60 PRIMARY, GAS MAIN X07 LOT 5 LOT 8 2 40 1 W 3 SCH80 2 60 SECONDARY, GAS SERVICE 2" PVC PLUG /CAPS = 10 2" YELLOW SCH 40 PVC = 285 FT 2" SCH80 GREY PVC = 90 FT 2" PVC PLUG /CAPS = 4 4" PVC PLUG /CAPS = 4 4" YELLOW SCH 40 PVC = 90 FT 3" SCH80 GREY PVC = 470 FT 3" PVC PLUG /CAPS = 18 DEVELOPER RESPONSIBLE FOR CONDUIT/WIRE FROM H1B TO IRRIGATION METER LOCATION Removed at site: Grid Number: kVA Rating: Foreman to redline the following information TRANSFORMER REMOVAL Company ID#: Primary phase connected to: Tested Secondary Voltage P02 318079-167833 25 SITE SPECIFIC NOTES AT SITE P02: GRID# 318096-167835 EXIST PSE OWNED 2010 75'CLH3 POLE TO REMAIN AT SITE P02: GRID# 318082-167834 REMOVE EXIST 2018 45' CLASS 3 POLE & ALL OH EQUIPMENT SPAN NOTES P01 TO P02: REMOVE EXIST #2 ACSR OH PRIMARY ±150' CABLE REMOVAL TABLE Location Cable Size & Type Quantity Length (per conductor)RemarksFromTo P02 H2A 4/0 UG TPX 65 65 Total Feet (4/0 UG TPX) Removed