HomeMy WebLinkAboutMFP17001799DEPARTMENT OF COMMUNITY
AND ECONOMIC DEVELOPMENT
Franchise Permit: MFP17001799
IVR Number: 17001799
Permit Inrman
Permit Name:Puget Sound Energy - Electric
Address/Lcan :04/21/2017Aican Date :8857670060Parce Number :400 S 43RD ST
Permit Tye :05/10/2017Issue Date:Franchise
Permit Wrk Cass :05/10/2018Eiran Date :Minor lity
Jb Number :105084325Franchise Tye :Electric
Descrin:Install 3 phase j box and 3 phase ug line extension to new pm transformer. Pre onstrucon meeng reu ired.
Cntacts
Name Address PhneTyeBiing
arli Bunkelman
PSE/POTELO - Billing
6905 S 228th St
Kent, WA 98032
B: (253) 437-6708ApplicantX
VIKI HENSON
POTELO IN
8001 212th St S
Kent, WA 98032
B: (253) 863-0484ontractor
Business License Number: BL.005109Eectrica Cntractr : POTELI*344O4
Cnstrucn Cntractr : POTELI*227PL
PBLI HOSP DIST#1 KING O P O BOX 50010
Renton, WA 98058
Owner
ITY OF RENTON ROW 1055 S Grady Way
Renton, WA 98057-3232
Owner
enera Cndins & Signature
Permission is hereby gien for the work described o n this permit according to the condions hereon and according to the approed
plans and specicaons pertaining thereto, subject to compliance with the Ordinance of the ity of Ren ton.
This permit and plans must be posted at the job site at all mes .
I hereby cerfy that no work is to be done except a s described aboe and in approed plans, and that w ork is to conform to Renton
Trench Restoraon and Street Oerlay Reuirements .
all (425) 430-7203 or go to: www.MyBuildingPermit.com one working day in adance to schedule an inspe cons and for ANY work in
the Right of Way.
all 8 1 1 to locate underground ulies at least two full bus iness days prior to any excaaon .
In accordance with RW 19.122.033(4) the permit hol der is reuired to contact (Williams Northwest Pipe line at 425.868.1010) (Olympic
Pipeline at 206.510.0575)(Puget Sound Energy at 425.457.5816) to reuest a consultaon with the transm ission pipeline company prior
to performing any construcon or excaaon acies . This reuirement to consult with the transmissio n pipeline company is in
addion to the reuirement to all before You Dig a s reuired in RW 19.122.
(Date)(Signature)
Page 1 of 2THIS PERMIT AND PLANS MUST BE POSTED AT THE JOB SITE AT ALL TIMES
DEPARTMENT OF COMMUNITY
AND ECONOMIC DEVELOPMENT
Page 1 | Published: 3/30/2017
Planning Division | 1055 South Grady Way, 6th Floor | Renton, WA 98057 | 425-430-7200
Email: franchisepermits@rentonwa.gov Website: rentonwa.gov
FRANCHISE PERMIT APPLICATION
Published: 3/30/2017
TO THE APPLICANT: Submit an electronic copy of the plans with the Franchise Permit Application and the
Traffic Control Application to franchisepermits@rentonwa.gov. Permit cost is $360.50. Inspection fee for
trenching more than 60 lineal feet or installation of 6 or more poles will be billed at $60.00 per hour.
Franchise Agency:
Franchise Job Number: Phone:
Contact Name: Email:
Job Site Address: Project Name:
Description of Work:
Please check all that apply:
☐ New Construction ☐ Repair/Relocate ☐ Underground ☐ Overhead ☐ Sidewalk ☐ Street
☐ Open Trench ☐ Bore # of feet:
Contractor Name: Phone:
State Contractors License #: City of Renton Business License #:
“I certify that I am the owner or applicant’s authorized agent and do hereby agree to abide to the terms and conditions set forth under this permit and shall comply with the City of Renton’s Trench Restoration and Street Overlay Requirements. ”
Signature Date
INSPECTIONS SHALL BE REQUESTED 24 HOURS PRIOR TO COMMENCEMENT OF ALL WORK BY CALLING THE
INSPECTION LINE AT 425-430-7203 OR BY GOING TO MYBUILDINGPERMIT.COM
Jobs are required to be called in for job start, re-inspection and project final. Re-inspection fees are billed at $75/hour.
All Pre-Construction meetings shall be scheduled at a maximum of 14 days prior to the job start date.
Plan Review/Development Engineering Date Approved as submitted
Pre-Construction Meeting required
Site Construction Inspector Date Approved with comments or redlines
Camera inspection of utilities required
Development Engineering Manager Date
Puget Sound Energy
105084325
Carli Bunkelman
253-437-6708
Carli.Bunkelman@pse.com
400 s 43rd St UW VMC MOB
Crew to install 3 phase j box and a 3 phase ug line extension to newpm transformer
to serve "400".
10'
Potelco Inc.253-437-6708
BL005109 Poteli*227PL
4/19/2017
Justin Johnson 04/24/2017
MFP17001799
Holly Powers 5/4/2017
CITY OF RENTON
TRAFFIC CONTROL PLAN
PROJECT NAME: PERMIT#
CONSTRUCTION COMPANY: PHONE#:
CONTACT NAME: PHONE#:
ADDRESS: CELL#:
E-MAIL ADDRESS: FAX#:
PROJECT LOCATION: N/E/S/W OF:
WORK TIME: APPROVED BY:
WORK DATE: APPROVAL DATE:
OFFICE COPY T-
CONTRACTOR
DEV. SERVICE, INSPECTION P. MILLER
DEV. SERVICE, PLAN REVIEW B. BANNWARTH
POLICE CHARLES KARLEWICZ
FIRE FIRE MARSHALL FS #13
Permit Holder agrees to all the following:
• Comply with all traffic regulations of the City of Renton and the State of Washington.
• Prepare a traffic control plan and obtain City approval of that plan. That plan shall be implemented for
all street and lane closures, and the plan shall be performed in compliance with the Manual on
Uniform Traffic Control Devices.
• Notify emergency services (253-852-2121) twenty-four (24) hours before any street or lane closures.
• Any lane or street closures not in conformance with the approved traffic control plan and/or without
notification of emergency services may result in receiving a citation for violation of R.C.W. 47.36.200
through 47.36.220, 9A.36.050 Reckless Endangerment, and other applicable State and City codes.
• Indemnify and hold harmless the City of Renton from any and all claims, actions, and judgments,
including all costs of defense and attorney’s fees incurred in defending against same, arising from and
related to implementation of the approved traffic control plans including claims arising from towing of
private vehicles and the acts of the Permit Holder’s agents and employees.
• The City of Renton shall be entitled, in its reasonable discretion, to settle claims prior to suit or
judgment, and in such event shall indemnify and hold harmless the City for any such claims paid,
including the City’s reasonable attorney’s fees and litigation costs incurred resulting from such claim.
• In the event any claim or suit is brought against City within the scope of this Agreement, Permit Holder
will pay for legal counsel chosen by the City to defend against same.
• Flagger and sign placement are subject to revision by the City Inspector on site, if needed to address
traffic or pedestrian safety or travel.
• By my signature herein, I acknowledge all the above requirements.
PRINT NAME: DATE:
SIGNATURE:
Reset FormPrint Form
UW VMC MOB
Potelco Inc.
Brad Elkin 425-495-6489
6905 S. 228th St, Kent, WA 98032
Brad.Elkin@pse.com
400 s 43rd St
8:30 am - 3:00 pm
Monday - Friday
Carli Bunkelman 4/19/2017
Justin Johnson 04/24/2017
SKETCH
I
-- NORTH --
I
NOTES:
• Work Zone Traffic Control shall be in accordance with the Manual on Uniform Traffic Control Devices (MUTCD)
and shown by sketch or reference to WSDOT.
• The plan must be submitted to the City’s PW/Transportation Division for review and/or approval at least three
working days prior to work.
• Approved Temporary Traffic Control Plan must be at the work site during work hours.
• Contractor or entity must call Renton School District (425-204-4455) or any public/private agency to be affected
by a temporary lane or road closure.
• Complete assistance and accommodation shall be provided to all kinds of pedestrian traffic when sidewalk or
walkway is impeded.
• Total road closure lasting more than 24 hours is subject to the approval by the City Council.
• Any vehicle, equipment, barricade, or portable tow-away sign used within the work area must display a
company logo or any legally acceptable sign showing the company name, address, and telephone number at a
conspicuous place on the vehicle or equipment.
In the case of Temporary No Parking Zones, all the following apply in addition to previous:
• Contractor must complete form to show limits of Temporary No Parking Zone identifying barricade locations for
vacate parking or curb lane usage.
• Contractor must post notice of dates and time of Temporary No Parking Zone with at least two signs per block
72 hours in advance of effective date and time.
• The cover sheet of this Traffic Control Plan form must be attached to each Temporary No Parking Sign on the
project site.
• Temporary traffic control devices must be removed immediately when work is done or no construction activities
are going on. If deemed abandoned, City crews will remove and store them at the City’s maintenance shop
(3555 NE 2nd Street).
P01
BUSSTOPRIGH
T
KEEP
R4-7BARRW-BRDW4-2LROADWORKAHEADW20-1RIGHT LANECLOSEDAHEADW20-5R100'100'100'CENTE
R
L
A
N
E
CLOS
E
D
AHEA
D W9-3ROA
D
WOR
K
AHEA
D W20-1100'100'100'W4-2RS 177th StTalbot Rd SCONETOPPERCONETOPPERROADWORKAHEADW20-111
111212R9-9SIDEWALKCLOSEDR9-9SIDEW
A
L
K
CLOSE
D
R9-11SIDE
W
A
L
K
CLOS
E
D
AHEA
D
DET
O
U
RM4-9bMOVE BUS STOP
APPROX
50' SOUTH
STOP
FLAGGER
SPOTTER TO ASSIST
PEDESTRIANS CROSS
A WORKING AREA
PLACE SIGNS
AT NEAREST
CROSSWALK
CHANNELIZATION
DEVICE SPACING
MPH
55/70
35/45
25/30
TAPER
40
30
20
TANGENT
80
60
40
N
PSE PUGET
SOUND
ENERGY
Job#105084325
400 S 43rd St Renton, WA
April 6th, 2017
Sheet 1 of 1 mitchell.peterson@pse.com
425-398-6071
Notes:
1. All signs and spacing to conform to the MUTCD
and City of Renton standards.
2. All sidewalks, driveways, exits and egresses
shall be completely clear unless otherwise indicated.
3. Channelizing devices are 28" traffic cones.
4. Sign size can be a minimum of 48" x 48" and
shall not obstruct pedestrian access.
5. Crew is required to leave a minimum of 11' for
traveling lane width.
6. Alert affected residents and businesses.
7. Work to take place between 9 a.m. and 4 p.m.
Puget Sound Energy
Traffic Control Supervisor:
Gregory Harwood
Card No. 008997
Card Exp. 08/13/2019
gregory.harwood@pse.com
(425)424-6425
28" TRAFFIC CONE
TRAFFIC FLOW
WORK VEHICLE
SIGN LOCATION
WARNING FLAG
STOP
FLAGGER
LEGEND
POLE
ARROW BOARD
DNDNDNNEW MEDICAL OFFICE BUILDINGPLANTED AREAENTRY / DROP-OFFENTRY / DROP-OFFPLANTED AREAPLANTED AREAPLANTED AREAEXISTING CURB TO BE DEMOLISHEDEDGE OF BUILDINGBELOWHCVAN+97'-3"+81'-0"RETAINING WALLHCVANFIRE LANE REQUIREMENTSNO PARKING ALLOWED IN DESIGNATED ZONE.13'-6" VERTICAL HEIGHT CLEARANCE MINIMUM.IDENTIFICATION SIGNAGE TO BE SPACED NOGREATER THAN 50'-0" APART.TRASHUTILITY TRANSFORMERARCHITECTURALGATE ANDSCREEN WALL+97'-3"MECHELECEMERGENCYTRANSFORMERUTILITY TERMINALCABINET10'-0" TRANSFORMERCLEARANCEPLANTED AREAENTRY CANOPY ABOVEPICK-UPHCVANHCVANBENCH SEATBENCH SEATBENCH SEATRETAINING WALLRETAINING WALLSTEPS LIGHTSBOLLARD LIGHTBOLLARD LIGHTBOLLARD (NO LIGHT)BOLLARD LIGHTBOLLARD LIGHTBOLLARD (NO LIGHT)10'
277'
82'
8'
S 177TH STTALBOT RD SVIC
16
15'
SITE PLAN
N
Vicinity Map
N/A
Owner / Developer Contact Info
officeATTN:
UW VMC MOB
400 S 43ST
RENTON, WA 98055
CHRIS BARKER (206)623-0717 105084325THIS SKETCH NOT TO BE RELIED UPON FOR EXACT LOCATION OF EXISTING FACILITIES
CALL (800) 424-5555
2 BUSINESS DAYS BEFORE YOU DIG
For contacts below dial 1-888-CALL PSE (225-5773)
SITE SPECIFIC NOTES
OVERHEAD CIRCUIT MAP
SCALE: NONE
CIRCUIT FEET ADDED: 370' 3Ø
ARE TO BE INSTALLED, CROSS SECTION DETAILS OF THE TYPICAL EROSION
STRUCTURES, & SPECIAL REQUIREMENTS FOR WORK IN SENSITIVE AREAS.)
EROSION & SEDIMENT CONTROL REQUIREMENTS
NOTES DETAILING WHERE EROSION OR SEDIMENT CONTROL STRUCTURES
(LOCAL JURISDICTIONS MAY HAVE ADDITIONAL REQUIREMENTS INCLUDING
0150.3200 TECHNIQUES FOR TEMPORARY EROSION & SEDIMENT CONTROL
EROSION & SEDIMENT CONTROL SHALL BE PER PSE STANDARD PRACTICE
& ANY ADDITIONAL LOCAL JURISDICTION REQUIREMENTS.
FOREMAN (CHECK BOX WHEN COMPLETED)
PSE Equipment LOCKED/SECURED & Work Area left in CLEAN/SAFE Condition.
Grid, Cable, and Switch numbers INSTALLED & VERIFIED.
Field Changes RED-LINED on As-built.
Indicate correct FUSE SIZE on As-built & VERIFY proper PHASE.
Foreman's Signature _______________________________________________
Print Name ___________________________________ Date ______________
Material VERIFIED and CHANGES noted on Paperwork.
Total PRIMARY Cable noted on As-built.
Company ID#'s RECORDED in correct location on As-built.
Deviations noted on the As-built and their reason.
I certify that the work performed meets PSE's standards and procedures
and that all quality requirements are met.
CIRCUIT LOADING TABLE
AS OF
EXIST. PEAK LOAD
EST. NEW LOAD
TOTAL
CIRCUIT:
A PHASE B PHASE C PHASE
VIC-16
2016
253 202 210
35.45 35.45 35.45
288.45 237.45 245.45
GAS
PHONE
CABLE TV
503963685 105084325
N/A 108100001
N/A 594113515
N/A 593182157
N/A N/A
504422733 104289639
N/A N/A
N/A N/A
N/A N/A
PROJECT PHASE
PWR
NOTIF#ORDER#
Superior
Perm. Service
Relocation
Removal
Temporary
Job Order
Distribution
HP Main
HP Svc/MSA
POWER GENERAL NOTES - COMMERCIAL PROJECT
8.
EXCAVATION: The customer is to provide all trenching, backfill, vault excavations, compaction and
restoration per this sketch and per PSE standards. A minimum protective cover of 36" is required over
PSE's primary voltage equipment and 24" is required of PSE's secondary voltage equipment. The customer
will provide any and all shoring or they will side slope the trench to 1:1.
All materials to be installed in accordance with Puget Sound Energy's (PSE) standards. Any deviation from
this work sketch must be AUTHORIZED by PSE's Project Manager and NOTED on the Foremans' Copy.
All switching arrangements and/or outage arrangements are to be made with the Project Manager at least
three (3) working days in advance.
Contact the Utilities Underground Location Center (1-800-424-5555) at least 48 hours prior to commencing
work to get the underground facilities located.
STAKING: The customer will provide all staking (transformer, handhole, trench, grade, lot, pole, sidewalk,
etc.). See sketch and details for locations. Equipment locations must be approved by the Project Manager.
SITE PREPARATION: The work area will be at or near finished grade, clear of trench spoils or construction
materials which would restrict construction and/or equipment access, before work can begin.
Roads shall be paved or have a compacted , crushed rock base in place.
CLEARANCES: Transformers require a minimum of 6 feet from fire fighting equipment, 10 feet from
combustible walls, overhangs, doors, and windows, and a minimum of 5 feet from the back of curb (or guard
posts will be required per PSE standards). All conduits and vaults are to be at least 5 feet away from water,
storm and sewer lines when paralleling them in the right of way, and at least 1 foot when crossing them.
All work is to be done in accordance with local municipal and county permit requirements as applicable.
Customer/Developer is responsible to provide, install and maintain all secondary service cables, conduits
and crossings from the individual unit's meter base to the designated connection point.
Inclement weather conditions may cause delays in construction times and dates.
1.
2.
3.
4.
5.
6.
7.
9.
11.
10.
PSE
No
No
No
Yes
Yes
Yes
No
YesDeveloper
"Flagging Required"
"Outages Required"
"Locates Required"
E-Mail:
Cell Phone:
Project Manager Contact Information:
Manager:BRAD ELKIN
425-495-6489
bradley.elkin@pse.com
LRC:
% V. Drop:
% Flicker:
Sq. Footage:
Panel Size:
Heat Type:
Est. Demand:
160,000SQ.
4000AMPS
ELEC
650KW
390A
2.8%
1.8%
SCALE: 1" = 50'
UTILITIES
CONTACT
PHONE#
COUNTY
1/4 SEC
U-MAP NO (POWER)
OP MAP
Emer Sect Gas Wk Ctr POWER WK CTR
PLAT MAP
JOINT FACILITIES ARRANGEMENTS
DRAWN BY
CHECKED BY
APPROVED BY
FOREMAN #1
FOREMAN #2
MAPPING
INCIDENT MAOP
Gas Order Elect Order
SCALE PAGE
ENGR - POWER
ENGR - GAS
FUNCTION
PROJECT MGR
PERMITREAL ESTATE/EASEMENT
2
1
REV#
3
DATE DESCRIPTIONBY
CONTACT PHONE NO DATE
OH CKT MAP CIRCUIT NOUG CKT MAP
BRAD ELKIN 425-495-6489 03/30/17
BRAD ELKIN 425-495-6489 03/30/17
N/A N/A N/A
J. REIBMAN N/A 03/30/17
EASEMENT REQUIRED CITY OF RENTON
UW VMC MOB
INSTALL 3Ø J-BOX & 3Ø L/E & PM TRF
400 S 43ST, RENTON, WA 98055
N/A N/A
N/A 105084325
AS NOTED 1/2
KING N/A N/A CSPSKEIN
T23N, R05E, NE SEC 31 N/A N/A
2305E121 2305E124 2305E121 VIC-16
N/A
N/A
N/A
N/A
N/A
N/A
N/A
N/A
N/A
N/A
N/A
N/A
PRIMARY CABLE & CONDUIT TABLE
LOCATION CONDUIT PRIMARY CABLE
ASBUILT INFORMATION
SIZE Qty LENGTH
Design
(ft)
BENDS PULL PULL Cable LENGTH
Design
(ft)
Cable Numbers Please Record Foreman - Complete
FROM TO (in)90°45°22°11°(lbs)
Rev
(lbs)Size A B C Manufacturer Compound Year Actual Amount Installed (Conduit & Cable)
P01 J01 4 1 10 1 3Ø PRI 60 EHM675 EHM676 EHM677
J01 V01 2 1 15 1 1Ø PRI 25 EHM678 REPLACE EXISTING CABLE & NEW TAGS
V01 V02 4 1 370 1 1 3Ø PRI 390 EHM679 EHM680 EHM681
Vault & Equipment Table
Site Grid
Number
Vault Size
& Cover
Type & Size
Equipment
In Vault
Primary Bushings Transformer
ID Numbers
(Company ID)
ASBUILT INFORMATION
Foreman-Complete
LB DC
J01 316503
165935
5'X7'
Diamond PL Lid
Matid: 7663200
J-BOX
Matid: 7625900 7 5
V01 316503
165937 EXISTING EXISTING
1Ø TUT 2 -
EXISTING
V02 316512
165905
7'X7' W/ 8'X10' LID
Matid: 7917900
TRF
Matid: 6259350 3 -
P01
-REMOVE EXISTING 1Ø 200A TERM & 2" RISER
-INSTALL NEW 3Ø 200A TERM ON NEW TRI-UNIT
-INSTALL 1-4" PRIMARY RISER
J01
-INSTALL NEW 575 J-BOX
V01
-EXISTING 1Ø TUT 25kVA
V02
-INSTALL 3Ø 1000kVA 277/480v PM TRF
-CONNECT AND TAG 10 RUNS CUSTOMER OWNED SVC
SPAN NOTES
SEE TABLES
P01-V01
-REPLACE EXISTING 1Ø PRI AND RESERVE V01 FROM J01
SCALE: 6" = 1 MILE
UNDERGROUND CIRCUIT MAP EXISTING
JOB
SITE
JOB
SITE
SCALE: 6" = 1 MILE
UNDERGROUND CIRCUIT MAP FUTURE
JOB
SITE
15'
15'
8'11X11 WORK PIT
11X9 WORK PIT
4X4 WORK PIT
(1) RUN 3Ø 1/0 PRI, ± 50'
1-2" SCH'L 80 CONDUIT, ± 15'
(1) RUN 3Ø 4/0 PRI, ± 390'
1-2" SCH'L 80 CONDUIT, ± 370'
277'
82'
(1) RUN 1Ø 4/0 PRI, ± 35'
1-2" SCH'L 80 CONDUIT, ± 15'
SCALE: NONE
CIRCUIT ONE-LINE DIAGRAM
4'-0"
1'-0"
5'-8"
8"
7'-0"
Tubes for 1"
adjustable bolts ( 4)
Cover
2,490 lbs
Top Section
1,835 lbs
Base
4,760 lbs
4'-8"
(2) 3' Square
Plate Doors
NOTE: For Installations in pavement or sidewalks with adjustable cover
SIDE VIEW
TOP VIEW
9'-0"
11'-0"
2"
6'-0"
6"
Crushed
Rock
3-piece handhole, increase excavation Depth to 6'-6" and 24 cubic yards.
4'-8" x 7' Handhole ( 575) w/adjustable Cover
MID#: 7663206
VAULT & EXCAVATION DETAIL
Not to scale 6051.1500
Excavation - 20 cubic yards
Communications
Primary Power
Cables or Conduit
Excavated Dirt Pile
ROADSIDE
Final Grade
24" Min
4" Min
Separation
36"
Min
Cover
48"
Max
Backfill
(No rocks over 10" diameter)
Separation
12" Min
Gas
4" Sand Bedding
32" Typical
(Power, Gas, and
Communications)
JOINT TRENCH DETAIL
Primary-Mainline Gas & Communications (NTS)
Separation
12" Min
6" or 12" Min Sand Shading after Compaction
- A 6" layer of sand is allowed when excavated native material contains rocks no larger than 8" in diameter.
Trench and backfill requirements for primary electric line extension trenches (No PSE gas)
- A 12" layer of sand is required when excavated native material contains rocks up to 10" in diameter.
2"
Excavation - 20 cubic yards
10'-0"
7'-0"
8'-0"
8"
6'-2"
SIDE VIEW
6'-6"Crushed
6"
Rock
11'
11'
TOP VIEW
5'-6"
7'-0"
6775.0030Not to scale
VAULT & EXCAVATION DETAIL
UTILITIES
CONTACT
PHONE#
COUNTY
1/4 SEC
U-MAP NO (POWER)
OP MAP
Emer Sect Gas Wk Ctr POWER WK CTR
PLAT MAP
JOINT FACILITIES ARRANGEMENTS
DRAWN BY
CHECKED BY
APPROVED BY
FOREMAN #1
FOREMAN #2
MAPPING
INCIDENT MAOP
Gas Order Elect Order
SCALE PAGE
ENGR - POWER
ENGR - GAS
FUNCTION
PROJECT MGR
PERMITREAL ESTATE/EASEMENT
2
1
REV#
3
DATE DESCRIPTIONBY
CONTACT PHONE NO DATE
OH CKT MAP CIRCUIT NOUG CKT MAP
BRAD ELKIN 425-495-6489 03/30/17
BRAD ELKIN 425-495-6489 03/30/17
N/A N/A N/A
J. REIBMAN N/A 03/30/17
EASEMENT REQUIRED CITY OF RENTON
UW VMC MOB
INSTALL 3Ø J-BOX & 3Ø L/E & PM TRF
400 S 43ST, RENTON, WA 98055
N/A N/A
N/A 105084325
AS NOTED 2/2
KING N/A N/A CSPSKEIN
T23N, R05E, NE SEC 31 N/A N/A
2305E121 2305E124 2305E121 VIC-16
N/A
N/A
N/A
N/A
N/A
N/A
N/A
N/A
N/A
N/A
N/A
N/A
CONDUIT RISER PLACEMENT DETAIL
TOP VIEW
Not to Scale
Standoff Bracket
15" Min Length
Conduit Clamp Conduit
Field Face
Quadrant
Climbing
Space
Road Face
Quadrant
Climbing
Space
5" Min
CL LCDirection of Vehicular Traffic
COOLING
5' MIN
5' MIN
10' MIN
5'
MIN
FINS
ACCESS
CONCRETE PAD
MINIMUM CLEARANCES FOR PSE EQUIPMENT
CURB OR EDGE OF PAVEMENT
CURB OR EDGE OF PAVEMENT
5' MIN
ROAD OR
PARKING AREA
TYP. PAD
& TRANS-
FORMER
3'
MIN
18" MIN
18" MIN
DOOR
ACCESS
DOOR
REQUIRED
WORK SPACE
AREA
6775.0035 Not to scale
5' MIN
5' MIN
5'
MIN
10' MIN OF CLEARANCE FOR NON COMBUSTIBLES