HomeMy WebLinkAboutP_Utility Plan UW VMC MOB Sheet2_105084324_V1_17041915' 15' 8'11X11 WORK PIT 11X9 WORK PIT 4X4 WORK PIT (1) RUN 3Ø 1/0 PRI, ± 50' 1-2" SCH'L 80 CONDUIT, ± 15' (1) RUN 3Ø 4/0 PRI, ± 390' 1-2" SCH'L 80 CONDUIT, ± 370' 277' 82' (1) RUN 1Ø 4/0 PRI, ± 35' 1-2" SCH'L 80 CONDUIT, ± 15' SCALE: NONE CIRCUIT ONE-LINE DIAGRAM 4'-0" 1'-0" 5'-8" 8" 7'-0" Tubes for 1" adjustable bolts ( 4) Cover 2,490 lbs Top Section 1,835 lbs Base 4,760 lbs 4'-8" (2) 3' Square Plate Doors NOTE: For Installations in pavement or sidewalks with adjustable cover SIDE VIEW TOP VIEW 9'-0" 11'-0" 2" 6'-0" 6" Crushed Rock 3-piece handhole, increase excavation Depth to 6'-6" and 24 cubic yards. 4'-8" x 7' Handhole ( 575) w/adjustable Cover MID#: 7663206 VAULT & EXCAVATION DETAIL Not to scale 6051.1500 Excavation - 20 cubic yards Communications Primary Power Cables or Conduit Excavated Dirt Pile ROADSIDE Final Grade 24" Min 4" Min Separation 36" Min Cover 48" Max Backfill (No rocks over 10" diameter) Separation 12" Min Gas 4" Sand Bedding 32" Typical (Power, Gas, and Communications) JOINT TRENCH DETAIL Primary-Mainline Gas & Communications (NTS) Separation 12" Min 6" or 12" Min Sand Shading after Compaction - A 6" layer of sand is allowed when excavated native material contains rocks no larger than 8" in diameter. Trench and backfill requirements for primary electric line extension trenches (No PSE gas) - A 12" layer of sand is required when excavated native material contains rocks up to 10" in diameter. 2" Excavation - 20 cubic yards 10'-0" 7'-0" 8'-0" 8" 6'-2" SIDE VIEW 6'-6"Crushed 6" Rock 11' 11' TOP VIEW 5'-6" 7'-0" 6775.0030Not to scale VAULT & EXCAVATION DETAIL UTILITIES CONTACT PHONE# COUNTY 1/4 SEC U-MAP NO (POWER) OP MAP Emer Sect Gas Wk Ctr POWER WK CTR PLAT MAP JOINT FACILITIES ARRANGEMENTS DRAWN BY CHECKED BY APPROVED BY FOREMAN #1 FOREMAN #2 MAPPING INCIDENT MAOP Gas Order Elect Order SCALE PAGE ENGR - POWER ENGR - GAS FUNCTION PROJECT MGR PERMITREAL ESTATE/EASEMENT 2 1 REV# 3 DATE DESCRIPTIONBY CONTACT PHONE NO DATE OH CKT MAP CIRCUIT NOUG CKT MAP BRAD ELKIN 425-495-6489 03/30/17 BRAD ELKIN 425-495-6489 03/30/17 N/A N/A N/A J. REIBMAN N/A 03/30/17 EASEMENT REQUIRED CITY OF RENTON UW VMC MOB INSTALL 3Ø J-BOX & 3Ø L/E & PM TRF 400 S 43ST, RENTON, WA 98055 N/A N/A N/A 105084325 AS NOTED 2/2 KING N/A N/A CSPSKEIN T23N, R05E, NE SEC 31 N/A N/A 2305E121 2305E124 2305E121 VIC-16 N/A N/A N/A N/A N/A N/A N/A N/A N/A N/A N/A N/A CONDUIT RISER PLACEMENT DETAIL TOP VIEW Not to Scale Standoff Bracket 15" Min Length Conduit Clamp Conduit Field Face Quadrant Climbing Space Road Face Quadrant Climbing Space 5" Min CL LCDirection of Vehicular Traffic COOLING 5' MIN 5' MIN 10' MIN 5' MIN FINS ACCESS CONCRETE PAD MINIMUM CLEARANCES FOR PSE EQUIPMENT CURB OR EDGE OF PAVEMENT CURB OR EDGE OF PAVEMENT 5' MIN ROAD OR PARKING AREA TYP. PAD & TRANS- FORMER 3' MIN 18" MIN 18" MIN DOOR ACCESS DOOR REQUIRED WORK SPACE AREA 6775.0035 Not to scale 5' MIN 5' MIN 5' MIN 10' MIN OF CLEARANCE FOR NON COMBUSTIBLES