HomeMy WebLinkAboutP_Utility PlanUW VMC MOB Sheet1_105084325_V1_170419DNDNDNNEW MEDICAL OFFICE BUILDINGPLANTED AREAENTRY / DROP-OFFENTRY / DROP-OFFPLANTED AREAPLANTED AREAPLANTED AREAEXISTING CURB TO BE DEMOLISHEDEDGE OF BUILDINGBELOWHCVAN+97'-3"+81'-0"RETAINING WALLHCVANFIRE LANE REQUIREMENTSNO PARKING ALLOWED IN DESIGNATED ZONE.13'-6" VERTICAL HEIGHT CLEARANCE MINIMUM.IDENTIFICATION SIGNAGE TO BE SPACED NOGREATER THAN 50'-0" APART.TRASHUTILITY TRANSFORMERARCHITECTURALGATE ANDSCREEN WALL+97'-3"MECHELECEMERGENCYTRANSFORMERUTILITY TERMINALCABINET10'-0" TRANSFORMERCLEARANCEPLANTED AREAENTRY CANOPY ABOVEPICK-UPHCVANHCVANBENCH SEATBENCH SEATBENCH SEATRETAINING WALLRETAINING WALLSTEPS LIGHTSBOLLARD LIGHTBOLLARD LIGHTBOLLARD (NO LIGHT)BOLLARD LIGHTBOLLARD LIGHTBOLLARD (NO LIGHT)10' 277' 82' 8' S 177TH STTALBOT RD SVIC 16 15' SITE PLAN N Vicinity Map N/A Owner / Developer Contact Info officeATTN: UW VMC MOB 400 S 43ST RENTON, WA 98055 CHRIS BARKER (206)623-0717 105084325THIS SKETCH NOT TO BE RELIED UPON FOR EXACT LOCATION OF EXISTING FACILITIES CALL (800) 424-5555 2 BUSINESS DAYS BEFORE YOU DIG For contacts below dial 1-888-CALL PSE (225-5773) SITE SPECIFIC NOTES OVERHEAD CIRCUIT MAP SCALE: NONE CIRCUIT FEET ADDED: 370' 3Ø ARE TO BE INSTALLED, CROSS SECTION DETAILS OF THE TYPICAL EROSION STRUCTURES, & SPECIAL REQUIREMENTS FOR WORK IN SENSITIVE AREAS.) EROSION & SEDIMENT CONTROL REQUIREMENTS NOTES DETAILING WHERE EROSION OR SEDIMENT CONTROL STRUCTURES (LOCAL JURISDICTIONS MAY HAVE ADDITIONAL REQUIREMENTS INCLUDING 0150.3200 TECHNIQUES FOR TEMPORARY EROSION & SEDIMENT CONTROL EROSION & SEDIMENT CONTROL SHALL BE PER PSE STANDARD PRACTICE & ANY ADDITIONAL LOCAL JURISDICTION REQUIREMENTS. FOREMAN (CHECK BOX WHEN COMPLETED) PSE Equipment LOCKED/SECURED & Work Area left in CLEAN/SAFE Condition. Grid, Cable, and Switch numbers INSTALLED & VERIFIED. Field Changes RED-LINED on As-built. Indicate correct FUSE SIZE on As-built & VERIFY proper PHASE. Foreman's Signature _______________________________________________ Print Name ___________________________________ Date ______________ Material VERIFIED and CHANGES noted on Paperwork. Total PRIMARY Cable noted on As-built. Company ID#'s RECORDED in correct location on As-built. Deviations noted on the As-built and their reason. I certify that the work performed meets PSE's standards and procedures and that all quality requirements are met. CIRCUIT LOADING TABLE AS OF EXIST. PEAK LOAD EST. NEW LOAD TOTAL CIRCUIT: A PHASE B PHASE C PHASE VIC-16 2016 253 202 210 35.45 35.45 35.45 288.45 237.45 245.45 GAS PHONE CABLE TV 503963685 105084325 N/A 108100001 N/A 594113515 N/A 593182157 N/A N/A 504422733 104289639 N/A N/A N/A N/A N/A N/A PROJECT PHASE PWR NOTIF#ORDER# Superior Perm. Service Relocation Removal Temporary Job Order Distribution HP Main HP Svc/MSA POWER GENERAL NOTES - COMMERCIAL PROJECT 8. EXCAVATION: The customer is to provide all trenching, backfill, vault excavations, compaction and restoration per this sketch and per PSE standards. A minimum protective cover of 36" is required over PSE's primary voltage equipment and 24" is required of PSE's secondary voltage equipment. The customer will provide any and all shoring or they will side slope the trench to 1:1. All materials to be installed in accordance with Puget Sound Energy's (PSE) standards. Any deviation from this work sketch must be AUTHORIZED by PSE's Project Manager and NOTED on the Foremans' Copy. All switching arrangements and/or outage arrangements are to be made with the Project Manager at least three (3) working days in advance. Contact the Utilities Underground Location Center (1-800-424-5555) at least 48 hours prior to commencing work to get the underground facilities located. STAKING: The customer will provide all staking (transformer, handhole, trench, grade, lot, pole, sidewalk, etc.). See sketch and details for locations. Equipment locations must be approved by the Project Manager. SITE PREPARATION: The work area will be at or near finished grade, clear of trench spoils or construction materials which would restrict construction and/or equipment access, before work can begin. Roads shall be paved or have a compacted , crushed rock base in place. CLEARANCES: Transformers require a minimum of 6 feet from fire fighting equipment, 10 feet from combustible walls, overhangs, doors, and windows, and a minimum of 5 feet from the back of curb (or guard posts will be required per PSE standards). All conduits and vaults are to be at least 5 feet away from water, storm and sewer lines when paralleling them in the right of way, and at least 1 foot when crossing them. All work is to be done in accordance with local municipal and county permit requirements as applicable. Customer/Developer is responsible to provide, install and maintain all secondary service cables, conduits and crossings from the individual unit's meter base to the designated connection point. Inclement weather conditions may cause delays in construction times and dates. 1. 2. 3. 4. 5. 6. 7. 9. 11. 10. PSE No No No Yes Yes Yes No YesDeveloper "Flagging Required" "Outages Required" "Locates Required" E-Mail: Cell Phone: Project Manager Contact Information: Manager:BRAD ELKIN 425-495-6489 bradley.elkin@pse.com LRC: % V. Drop: % Flicker: Sq. Footage: Panel Size: Heat Type: Est. Demand: 160,000SQ. 4000AMPS ELEC 650KW 390A 2.8% 1.8% SCALE: 1" = 50' UTILITIES CONTACT PHONE# COUNTY 1/4 SEC U-MAP NO (POWER) OP MAP Emer Sect Gas Wk Ctr POWER WK CTR PLAT MAP JOINT FACILITIES ARRANGEMENTS DRAWN BY CHECKED BY APPROVED BY FOREMAN #1 FOREMAN #2 MAPPING INCIDENT MAOP Gas Order Elect Order SCALE PAGE ENGR - POWER ENGR - GAS FUNCTION PROJECT MGR PERMITREAL ESTATE/EASEMENT 2 1 REV# 3 DATE DESCRIPTIONBY CONTACT PHONE NO DATE OH CKT MAP CIRCUIT NOUG CKT MAP BRAD ELKIN 425-495-6489 03/30/17 BRAD ELKIN 425-495-6489 03/30/17 N/A N/A N/A J. REIBMAN N/A 03/30/17 EASEMENT REQUIRED CITY OF RENTON UW VMC MOB INSTALL 3Ø J-BOX & 3Ø L/E & PM TRF 400 S 43ST, RENTON, WA 98055 N/A N/A N/A 105084325 AS NOTED 1/2 KING N/A N/A CSPSKEIN T23N, R05E, NE SEC 31 N/A N/A 2305E121 2305E124 2305E121 VIC-16 N/A N/A N/A N/A N/A N/A N/A N/A N/A N/A N/A N/A PRIMARY CABLE & CONDUIT TABLE LOCATION CONDUIT PRIMARY CABLE ASBUILT INFORMATION SIZE Qty LENGTH Design (ft) BENDS PULL PULL Cable LENGTH Design (ft) Cable Numbers Please Record Foreman - Complete FROM TO (in)90°45°22°11°(lbs) Rev (lbs)Size A B C Manufacturer Compound Year Actual Amount Installed (Conduit & Cable) P01 J01 4 1 10 1 3Ø PRI 60 EHM675 EHM676 EHM677 J01 V01 2 1 15 1 1Ø PRI 25 EHM678 REPLACE EXISTING CABLE & NEW TAGS V01 V02 4 1 370 1 1 3Ø PRI 390 EHM679 EHM680 EHM681 Vault & Equipment Table Site Grid Number Vault Size & Cover Type & Size Equipment In Vault Primary Bushings Transformer ID Numbers (Company ID) ASBUILT INFORMATION Foreman-Complete LB DC J01 316503 165935 5'X7' Diamond PL Lid Matid: 7663200 J-BOX Matid: 7625900 7 5 V01 316503 165937 EXISTING EXISTING 1Ø TUT 2 - EXISTING V02 316512 165905 7'X7' W/ 8'X10' LID Matid: 7917900 TRF Matid: 6259350 3 - P01 -REMOVE EXISTING 1Ø 200A TERM & 2" RISER -INSTALL NEW 3Ø 200A TERM ON NEW TRI-UNIT -INSTALL 1-4" PRIMARY RISER J01 -INSTALL NEW 575 J-BOX V01 -EXISTING 1Ø TUT 25kVA V02 -INSTALL 3Ø 1000kVA 277/480v PM TRF -CONNECT AND TAG 10 RUNS CUSTOMER OWNED SVC SPAN NOTES SEE TABLES P01-V01 -REPLACE EXISTING 1Ø PRI AND RESERVE V01 FROM J01 SCALE: 6" = 1 MILE UNDERGROUND CIRCUIT MAP EXISTING JOB SITE JOB SITE SCALE: 6" = 1 MILE UNDERGROUND CIRCUIT MAP FUTURE JOB SITE