HomeMy WebLinkAboutP_Utility Plan REVISED_105084322_V2_17041911' x 9' WORK PIT 8' x 8' WORK PIT (1) RUN 3Ø 1/OAL JKT UG PRI CABLE ±30' AØEHC194, BØEHC195, CØEHC196 EXISTING CONDUIT FROM DIP1 TO J02 (1) 4" DB120 GREY PVC CONDUIT ±10' J01 TO DIP1 (1) RUN 3Ø 1/OAL JKT UG PRI CABLE ±30' AØEHC197, BØEHC198, CØEHC199 (1) 4" DB120 GREY PVC CONDUIT ±10' (1) RUN 3Ø 1/OAL JKT UG PRI CABLE ±20' AØ54980, BØ54981, CØ54982 (1) 4" DB120 GREY PVC CONDUIT ±10' 4' x 4' WORK PIT S TOBIN STRAINIER AVE SLAKE AVE S54 95STARBUCKS X170 SHOPPING CENTER AØ54980 BØ54981 CØ54982 317967-165820 112.5kVA 120/208V 317968-165818 NEW 1/OAL (+&$‘ (+&%‘ (+&&‘ NEW 1/OAL (+&$‘ (+&%‘ (+&&‘317970-165831 CØADW830 GAS PHONE CABLE TV 594113508 104289608 PROJECT PHASE PWR NOTIF#ORDER# Superior PSE No No No Yes Yes Yes No YesDeveloper "Flagging Required" "Outages Required" "Locates Required" X X X X THIS SKETCH NOT TO BE RELIED UPON FOR EXACT LOCATION OF EXISTING FACILITIES CALL (800) 424-5555 2 BUSINESS DAYS BEFORE YOU DIG For contacts below dial 1-888-CALL PSE (225-5773)105084322Owner / Developer Contact Info officeATTN: BURKHEIMER FAMILY, LLC 1326 5TH AVENUE #708 SEATTLE, WA 98101 TED DIMOF 206-323-4144 N Vicinity Map NOT TO SCALE FOREMAN (CHECK BOX WHEN COMPLETED) PSE Equipment LOCKED/SECURED & Work Area left in CLEAN/SAFE Condition. Grid, Cable, and Switch numbers INSTALLED & VERIFIED. Field Changes RED-LINED on As-built. Indicate correct FUSE SIZE on As-built & VERIFY proper PHASE. Foreman's Signature _______________________________________________ Print Name ___________________________________ Date ______________ Material VERIFIED and CHANGES noted on Paperwork. Total PRIMARY Cable noted on As-built. Company ID#'s RECORDED in correct location on As-built. Correct QC Checklist(s) reviewed. Deviations noted on the As-built and their reason. I certify that the work performed meets PSE's standards and procedures and that all quality requirements are met. DESIGNED BY UTILITIES CONTACT PHONE# COUNTY 1/4 SEC U-MAP NO (POWER) OP MAP Emer Sect Gas Wk Ctr POWER WK CTR PLAT MAP JOINT FACILITIES ARRANGEMENTS DRAWN BY CHECKED BY APPROVED BY FOREMAN #1 FOREMAN #2 MAPPING INCIDENT MAOP Gas Order Elect Order SCALE PAGE ENGR - POWER ENGR - GAS FUNCTION PROJECT MGR PERMITREAL ESTATE/EASEMENT 2 1 REV# 3 DATE DESCRIPTIONBY CONTACT PHONE NO DATE OH CKT MAP CIRCUIT NOUG CKT MAP BRAD ELKIN 253-395-6872 3/8/17 BRAD ELKIN 253-395-6872 3/8/17 C. SNYDER 714-893-2405 3/15/17 REQUIRED RENTON RENTON STARBUCKS 3PH JBOX CUT-IN, 3PH UG L/E & TRF SET 68 RAINIER AVENUE S., RENTON, WA 98055 PSE 105084322 AS NOTED 1/1 KING CSPSKEIN NE18-T23N-R05E 2305E069 2305E076 PCR-13 TBD TBD TBD TBD TBD TBD TBD TBD TBD TBD TBD TBD 2305E069 504061832 105084322 E-Mail: Cell Phone: Project Manager Contact Information: Manager:BRAD ELKIN 253-395-6872 Ext. 82-6872 bradley.elkin@pse.com ARE TO BE INSTALLED, CROSS SECTION DETAILS OF THE TYPICAL EROSION STRUCTURES, & SPECIAL REQUIREMENTS FOR WORK IN SENSITIVE AREAS.) EROSION & SEDIMENT CONTROL REQUIREMENTS NOTES DETAILING WHERE EROSION OR SEDIMENT CONTROL STRUCTURES (LOCAL JURISDICTIONS MAY HAVE ADDITIONAL REQUIREMENTS INCLUDING 0150.3200 TECHNIQUES FOR TEMPORARY EROSION & SEDIMENT CONTROL EROSION & SEDIMENT CONTROL SHALL BE PER PSE STANDARD PRACTICE & ANY ADDITIONAL LOCAL JURISDICTION REQUIREMENTS. 504419758 OVERHEAD CIRCUIT MAP SCALE: 6" = 1 MILE SITE MAP SCALE: 1" = 50' CIRCUIT FEET ADDED: 30'POWER GENERAL NOTES - COMMERCIAL PROJECT 9. 7. 6. 5. 4. 3. 2. 1.All materials to be installed in accordance with Puget Sound Energy's (PSE) standards. Any deviation from this work sketch must be AUTHORIZED by Potelco's Project Manager and NOTED on the Foremans' Copy. All switching arrangements and/or outage arrangements are to be made with the Project Manager at least three (3) working days in advance. Contact the Utilities Underground Location Center (1-800-424-5555) at least 48 hours prior to commencing work to get the underground facilities located. STAKING: The customer will provide all staking (transformer, handhole, trench, grade, lot, pole, sidewalk, etc.). See sketch and details for locations. Equipment locations must be approved by the Project Manager. SITE PREPARATION: The work area will be at or near finished grade, clear of trench spoils or construction materials which would restrict construction and/or equipment access, before work can begin. CLEARANCES: Transformers require a minimum of 6 feet from fire fighting equipment, 10 feet from combustible walls, overhangs, doors, and windows, and a minimum of 5 feet from the back of curb (or guard posts will be required per PSE standards). All conduits and vaults are to be at least 5 feet away from water, storm and sewer lines when paralleling them in the right of way, and at least 1 foot when crossing them. All work is to be done in accordance with local municipal and county permit requirements as applicable. Inclement weather conditions may cause delays in construction times and dates. EXCAVATION: The customer is to provide all trenching, backfill, vault excavations, compaction and restoration per this sketch and per PSE standards. A minimum protective cover of 36" is required over PSE's primary voltage equipment and 24" is required of PSE's secondary voltage equipment. The customer will provide any and all shoring or they will side slope the trench to 1:1. 8. JOB SITE CIRCUIT LOADING TABLE AS OF EXIST. PEAK LOAD EST. NEW LOAD TOTAL CIRCUIT: A PHASE B PHASE C PHASE PCR-13 5.06.16 266 253 212 3.82 3.82 3.82 269.82 256.82 215.82 SITE SPECIFIC NOTES J01: 317968-165818 -INSTALL 4'-8" x 7'-0" VAULT & COVER -INSTALL (3) 4-POS J-BOX -INSTALL (9) L/B ELBOWS & (3) DUST CAPS -INSTALL GRID # V01: 317967-165820 -INSTALL 4'-8" SQ VAULT W/ 4'-8" x 5'-6" COVER ,167$//N9$‘3075)9 -INSTALL (3) L/B ELBOWS -INSTALL SECONDARY CONNECTORS -INSTALL GRID # -CONNECT & TAG CUSTOMER UG SVC (1 RUN OF UNK) SPAN SPECIFIC NOTES PSE TO INSTALL NEW PRIMARY CABLE & CONDUIT IN CUSTOMER PROVIDED TRENCH & EXCAVATION -SEE PRIMARY CABLE & CONDUIT TABLE CIVIL CONTRACTOR & CUSTOMER NOTES THE CUSTOMER IS RESPONSIBLE FOR PROVIDING ALL TRENCHING, SELECT BACKFILL, COMPACTION & RESTORATION PER PUGET SOUND ENERGY STANDARDS 6750.6500 -REQUIRED TO PROVIDE 11' X 9' WORK PIT AT J01 -REQUIRED TO PROVIDE 8' X 8' WORK PIT AT V01 -REQUIRED TO PROVIDE 4' X 4' WORK PIT AT DIP1 & DIP2 -REQUIRED TO FOLLOW ALL TRENCH DETAILS ON SELECT BACKFILL -REQUIRED TO PROVIDE EQUIPMENT TO PUMP OUT WATER FOR WORK PITS & TRENCH AT ALL TIMES -EXCAVATE & EXPOSE EXISTING PSE UG FACILITIES 48 HOURS PRIOR TO CONSTRUCTION -EXCAVATION, TRENCH & L&I INSPECTIONS ARE REQUIRED 48 HOURS PRIOR TO CONSTRUCTION -PSE INSPECTION IS REQUIRED PRIOR TO FINAL BACKFILL -PSE WILL NOT ENERGIZE FACILITIES UNTIL BACKFILL IS COMPLETE CUSTOMER TRENCHING IN CITY, COUNTY OR WSDOT R.O.W NOTES THE CUSTOMER IS RESPONSIBLE FOR REVIEWING THE MUNICIPALITIES' TRENCHING REQUIREMENTS UNDER THE PERMIT. ALL INSPECTIONS ARE REQUIRED BY PSE -IF A PRE-CON MEETING IS REQUIRED BY THE CITY, COUNTY OR WSDOT, A PSE PROJECT MANAGER WILL SET-UP & SCHEDULE A MEETING WITH THE MUNICIPALITY PRIOR TO ANY EXCAVATION OR INSTALLATION BEGINNING. ELECTRICIAN & CUSTOMER NOTES THE CUSTOMER IS RESPONSIBLE TO COORDINATE NEW 400-AMP METER INSTALLATION WITH PUGET SOUND ENERGY PROJECT MANAGER & THE METERING DEPARTMENT UPON L&I INSPECTION APPROVAL PSE CONTACT INFORMATION: -METER DEPARTMENT - DAVE MUTSCHLER AT (206) 396-2145 -PROJECT MANAGER - BRAD ELKIN AT (253) 395-6872 NEW CABLE & CONDUIT DIAGRAM NOT TO SCALE Sq. Footage: 2034 SQ FT Panel Size: 400 AMP Heat Type: GAS Est. Demand: 70kW LRC: 65A % V. Drop: 2.7% (208V) % Flicker: 1.0% (208V) FAULT CURRENT TABLE ‘3075$16)250(5 <9 208V WINDINGS LOCATION SIZE R/X MIN. %Z FAULT CURRENT V01 112.5 kVA 0.3 1.55 26,900 AMPS JOB SITE TOP VIEW Excavation - 10-1/3 cubic yards SIDE VIEW Rock Crushed 6" 4'-4" 2" 8'-0" 4'-8" 3'-6" 4'-8" 6" 20" 4'-8"5'-6" 44" 8'-0" No Secondary PSE Primary Conduit Customer's service wire conduits may enter at any corner other than the corner where the primary cable enters the vault. VAULT & EXCAVATION DETAIL @ V01 NOT TO SCALE 2" Excavation - 19-1/2 cubic yards SIDE VIEW 5'-4"Crushed 6" Rock TOP VIEW 9' 11' 7'-0" 4'-0" 1' 4'-8" VAULT & EXCAVATION DETAIL @ J01 NOT TO SCALE PRIMARY CABLE & CONDUIT TABLE LOCATION CONDUIT CABLE ASBUILT INFORMATION - FOREMAN COMPLETE FROM TO SIZE (IN)QTY. DESIGN LENGTH (FT) BENDS PULL (LBS) PULL REV (LBS) CABLE SIZE DESIGN LENGTH (FT) PHASE - ID TAG RECORD RECORD PHASE TAPPED & ACTUAL FOOTAGE INSTALLED 90°45°22°11°A B C MANUFACTURER COMPOUND YEAR NOTES CONDUIT CABLE J01 DIP1 4 1 10 -1 --CONDUIT ONLY - J01 J02 CABLE ONLY 131 131 1/0 AL JKT 30 EHC194 EHC195 EHC196 - J01 DIP2 4 1 10 ----105 105 1/0 AL JKT 20 54980 54981 54982 - J01 V01 4 1 10 1 ---154 155 1/0 AL JKT 30 EHC197 EHC198 EHC199 - 4" PVC (FT) & BENDS =30 1 1 0 0 1/0 AL JKT TOTAL (FT) =240 VAULT & EQUIPMENT TABLE SITE #GRID # VAULT SIZE & COVER TYPE & SIZE EQUIPMENT IN VAULT PRIMARY BUSHINGS TRANSFORMER ID NUMBERS (COMPANY ID) AS-BUILT INFORMATION LB DC FOREMAN: INCLUDE PHASE TAPPED J01 317968 165818 5' x 7' x 5' Matid: 7663200 9 3 V01 317967 165820 4'8" x 4'8" x 3'6" Matid: 7663900 112.5KVA MP TRF 120/208V Matid: 6258050 3 0 CIRCUIT FEET REMOVED: 20' UNDERGROUND CIRCUIT MAP SCALE: 1" = 100' Perm. Service PRIMARY CABLE TRENCH DETAIL NOT TO SCALE Communications Primary Power Cables or Conduit Excavated Dirt Pile ROADSIDE Final Grade 24" Min 4" Min Separation 36" Min Cover 48" Max Backfill (No rocks over 10" diameter) Separation 12" Min Gas 4" Sand Bedding 32" Typical (Power, Gas, and Communications) Separation 12" Min 6" or 12" Min Sand Shading after Compaction - A 6" layer of sand is allowed when excavated native material contains rocks no larger than 8" in diameter. Trench and backfill requirements for primary electric line extension trenches (No PSE gas) - A 12" layer of sand is required when excavated native material contains rocks up to 10" in diameter. Installed at site: Grid Number: kVA Rating: Foreman to redline the following information TRANSFORMER INSTALLATION Company ID#: Primary phase connected to: Tested Secondary Voltage Material ID#: V01 317967-165820 112.5kVA COOLING FINS ACCESS CONCRETE MINIMUM CLEARANCES FOR PSE EQUIPMENT NOT TO SCALE CURB OR CURB OR EDGE OF PAVEMENT TYP. PAD & TRANS- FORMER DOOR 5' MIN5' MIN 10' MIN 5' MIN 5' MIN 3' MIN 3' MIN 3' MIN ROAD OR PARKING AREA PAD REQUIRED WORK SPACE AREA EDGE OF PAVEMENT