Loading...
HomeMy WebLinkAboutMFP17002351DEPARTMENT OF COMMUNITY AND ECONOMIC DEVELOPMENT Franchise Permit: MFP17002351 IVR Number: 17002351 Permit Informa!on Permit Name:Puget Sound Energy - Electric Address/Loca!on:05/19/2017Applica!on Date:3623049113Parcel Number:601 SW 41ST ST Permit Type :05/22/2017Issue Date:Franchise Permit Work Class:05/22/2018Expira!on Date :Minor U%lity Job Number:#101105002Franchise Type :Electric Descrip!on:INSTALL 2 NEW J BOXES IN ROW OF LIND AVE SW TO RE ROUTE PRIMARY POWER AROUND NEW PARKING LOT ENTRANCE TO IKEA. Contacts Name Address PhoneTypeBilling Carli Bunkelman PSE/POTELCO - Billing 6905 S 228th St Kent, WA 98032 B: (253) 437-6708Applicant VICKI HENSON POTELCO INC 8001 212th St S Kent, WA 98032 B: (253) 863-0484Contractor Business License Number: BL.005109Electrical Contractor : POTELI*344O4 Construc!on Contractor : POTELI*227PL CITY OF RENTON ROW 1055 S Grady Way Renton, WA 98057-3232 Owner Carli Bunkelman PSE/POTELCO - Billing 6905 S 228th St Kent, WA 98032 B: (253) 437-6708Specialized Billing X General Condi!ons & Signature Permission is hereby given for the work described on this permit according to the condi%ons hereon and according to the approved plans and specifica%ons pertaining thereto, subject to compliance with the Ordinance of the City of Renton. This permit and plans must be posted at the job site at all %mes . I hereby cer%fy that no work is to be done except as described above and in approved plans, and that work is to conform to Renton Trench Restora%on and Street Overlay Requirements . Call (425) 430-7203 or go to: www.MyBuildingPermit.com one working day in advance to schedule an inspec%ons and for ANY work in the Right of Way. Call 8 1 1 to locate underground u%li%es at least two full business days prior to any excava%on . In accordance with RCW 19.122.033(4) the permit holder is required to contact (Williams Northwest Pipeline at 425.868.1010) (Olympic Pipeline at 206.510.0575)(Puget Sound Energy at 425.457.5816) to request a consulta%on with the transmission pipeline company prior to performing any construc%on or excava%on ac%vi%es . This requirement to consult with the transmission pipeline company is in addi%on to the requirement to Call before You Dig as required in RCW 19.122. (Date)(Signature) Page 1 of 2THIS PERMIT AND PLANS MUST BE POSTED AT THE JOB SITE AT ALL TIMES DEPARTMENT OF COMMUNITY AND ECONOMIC DEVELOPMENT Page 1 | Published: 3/30/2017 Planning Division | 1055 South Grady Way, 6th Floor | Renton, WA 98057 | 425-430-7200 Email: franchisepermits@rentonwa.gov Website: rentonwa.gov FRANCHISE PERMIT APPLICATION Published: 3/30/2017 TO THE APPLICANT: Submit an electronic copy of the plans with the Franchise Permit Application and the Traffic Control Application to franchisepermits@rentonwa.gov. Permit cost is $360.50. Inspection fee for trenching more than 60 lineal feet or installation of 6 or more poles will be billed at $60.00 per hour. Franchise Agency: Franchise Job Number: Phone: Contact Name: Email: Job Site Address: Project Name: Description of Work: Please check all that apply: ☐ New Construction ☐ Repair/Relocate ☐ Underground ☐ Overhead ☐ Sidewalk ☐ Street ☐ Open Trench ☐ Bore # of feet: Contractor Name: Phone: State Contractors License #: City of Renton Business License #: “I certify that I am the owner or applicant’s authorized agent and do hereby agree to abide to the terms and conditions set forth under this permit and shall comply with the City of Renton’s Trench Restoration and Street Overlay Requirements. ” Signature Date INSPECTIONS SHALL BE REQUESTED 24 HOURS PRIOR TO COMMENCEMENT OF ALL WORK BY CALLING THE INSPECTION LINE AT 425-430-7203 OR BY GOING TO MYBUILDINGPERMIT.COM Jobs are required to be called in for job start, re-inspection and project final. Re-inspection fees are billed at $75/hour. All Pre-Construction meetings shall be scheduled at a maximum of 14 days prior to the job start date. Plan Review/Development Engineering Date Approved as submitted Pre-Construction Meeting required Site Construction Inspector Date Approved with comments or redlines Camera inspection of utilities required Development Engineering Manager Date Puget Sound Energy 101105002 Carli Bunkelman 253-437-6708 Carli.Bunkelman@pse.com 601 SW 41st St Crew to install 2 new j boxes in ROW of Lind Ave SW, re-routing primary around new parking lot entrance to Ikea. 100' +/- Potelco Inc.253-437-6708 BL005109 Poteli*227PL 5/11/2017 4 4 Carli Bunkelman IKEA MFP17002351 Holly Powers Justin Johnson 5-22-2017 5-22-2017 CITY OF RENTON TRAFFIC CONTROL PLAN PROJECT NAME: PERMIT# CONSTRUCTION COMPANY: PHONE#: CONTACT NAME: PHONE#: ADDRESS: CELL#: E-MAIL ADDRESS: FAX#: PROJECT LOCATION: N/E/S/W OF: WORK TIME: APPROVED BY: WORK DATE: APPROVAL DATE: OFFICE COPY T- CONTRACTOR DEV. SERVICE, INSPECTION P. MILLER DEV. SERVICE, PLAN REVIEW B. BANNWARTH POLICE CHARLES KARLEWICZ FIRE FIRE MARSHALL FS #13 Permit Holder agrees to all the following: • Comply with all traffic regulations of the City of Renton and the State of Washington. • Prepare a traffic control plan and obtain City approval of that plan. That plan shall be implemented for all street and lane closures, and the plan shall be performed in compliance with the Manual on Uniform Traffic Control Devices. • Notify emergency services (253-852-2121) twenty-four (24) hours before any street or lane closures. • Any lane or street closures not in conformance with the approved traffic control plan and/or without notification of emergency services may result in receiving a citation for violation of R.C.W. 47.36.200 through 47.36.220, 9A.36.050 Reckless Endangerment, and other applicable State and City codes. • Indemnify and hold harmless the City of Renton from any and all claims, actions, and judgments, including all costs of defense and attorney’s fees incurred in defending against same, arising from and related to implementation of the approved traffic control plans including claims arising from towing of private vehicles and the acts of the Permit Holder’s agents and employees. • The City of Renton shall be entitled, in its reasonable discretion, to settle claims prior to suit or judgment, and in such event shall indemnify and hold harmless the City for any such claims paid, including the City’s reasonable attorney’s fees and litigation costs incurred resulting from such claim. • In the event any claim or suit is brought against City within the scope of this Agreement, Permit Holder will pay for legal counsel chosen by the City to defend against same. • Flagger and sign placement are subject to revision by the City Inspector on site, if needed to address traffic or pedestrian safety or travel. • By my signature herein, I acknowledge all the above requirements. PRINT NAME: DATE: SIGNATURE: Reset FormPrint Form Potelco Inc. Devendra Kumar 425-516-5486 6905 S. 228th St, Kent, WA 98032 Carli.Bunkelman@pse.com 601 SW 41st St 9:00 am to 3:00 pm Monday through Friday 5-22-2017 Carli Bunkelman 5/11/2017 Carli Bunkelman MFP17002351IKEA Justin Johnson SKETCH I -- NORTH -- I NOTES: • Work Zone Traffic Control shall be in accordance with the Manual on Uniform Traffic Control Devices (MUTCD) and shown by sketch or reference to WSDOT. • The plan must be submitted to the City’s PW/Transportation Division for review and/or approval at least three working days prior to work. • Approved Temporary Traffic Control Plan must be at the work site during work hours. • Contractor or entity must call Renton School District (425-204-4455) or any public/private agency to be affected by a temporary lane or road closure. • Complete assistance and accommodation shall be provided to all kinds of pedestrian traffic when sidewalk or walkway is impeded. • Total road closure lasting more than 24 hours is subject to the approval by the City Council. • Any vehicle, equipment, barricade, or portable tow-away sign used within the work area must display a company logo or any legally acceptable sign showing the company name, address, and telephone number at a conspicuous place on the vehicle or equipment. In the case of Temporary No Parking Zones, all the following apply in addition to previous: • Contractor must complete form to show limits of Temporary No Parking Zone identifying barricade locations for vacate parking or curb lane usage. • Contractor must post notice of dates and time of Temporary No Parking Zone with at least two signs per block 72 hours in advance of effective date and time. • The cover sheet of this Traffic Control Plan form must be attached to each Temporary No Parking Sign on the project site. • Temporary traffic control devices must be removed immediately when work is done or no construction activities are going on. If deemed abandoned, City crews will remove and store them at the City’s maintenance shop (3555 NE 2nd Street). Lind Ave SWJJ01 JJ03 JJ02 IP1 IP2 R9-9SIDEWALK CLOSEDR9-9SIDEWALKCLOSEDARRW-BRD ROAD WORK AHEAD W20-1350'R9-11SIDEWALK CLOSED AHEAD DETOURM4-9bDETOURM4-9bR9-11SIDEWALKCLOSEDAHEAD12 11111111 11 111111 11 11111111111111111111W4-2LROADWORKAHEADW20-1RIGHT LANECLOSEDAHEADW20-5R350'350'350'ROADWORKAHEADW20-1 ROADWORKAHEADW20-1SW 41st St PLACE SIGNS AT SW 43RD ST INTERSECTION CHANNELIZATION DEVICE SPACING MPH 55/70 35/45 25/30 TAPER 40 30 20 TANGENT 80 60 40 N PSE PUGET SOUND ENERGY Job#101105002 601 SW 41st St Renton, WA May 8th, 2017 Sheet 1 of 1 mitchell.peterson@pse.com 425-398-6071 PRINT ON 11X17" SHEETS ONLY Notes: 1. All signs and spacing to conform to the MUTCD and City of Renton standards. 2. All sidewalks, driveways, exits and egresses shall be completely clear unless otherwise indicated. 3. Channelizing devices are 28" traffic cones. 4. Sign size can be a minimum of 48" x 48" and shall not obstruct pedestrian access. 5. Crew is required to leave a minimum of 11' for traveling lane width. 6. Alert affected residents and businesses. 7. Work to take place between 9 a.m. and 4 p.m. Puget Sound Energy Traffic Control Supervisor: Gregory Harwood Card No. 008997 Card Exp. 08/13/2019 gregory.harwood@pse.com (425)424-6425 28" TRAFFIC CONE TRAFFIC FLOW WORK VEHICLEWORK VEHICLE SIGN LOCATION WARNING FLAG LEGEND VAULTVault ARROW BOARD LIND AVE SW316471-165629 316474-165628 316465-165628 316471-165641 WORK ZONE SE 43RD ST SW 43RD ST LIND AVE SWSW 41ST ST WORK ZONE SITE PLAN Owner / Developer Contact Info officeATTN: IKEA PROPERTY INC 420 ALAN WOOD RD CONSHOHOKEN, PA 19428 JIM MEYER (425) 484-4100 101105002THIS SKETCH NOT TO BE RELIED UPON FOR EXACT LOCATION OF EXISTING FACILITIES CALL (800) 424-5555 2 BUSINESS DAYS BEFORE YOU DIG For contacts below dial 1-888-CALL PSE (225-5773) SITE SPECIFIC NOTES OVERHEAD CIRCUIT MAP(2305E124) SCALE: 6" = 1 MILE CIRCUIT FEET REMOVED: 160' ARE TO BE INSTALLED, CROSS SECTION DETAILS OF THE TYPICAL EROSION STRUCTURES, & SPECIAL REQUIREMENTS FOR WORK IN SENSITIVE AREAS.) EROSION & SEDIMENT CONTROL REQUIREMENTS NOTES DETAILING WHERE EROSION OR SEDIMENT CONTROL STRUCTURES (LOCAL JURISDICTIONS MAY HAVE ADDITIONAL REQUIREMENTS INCLUDING 0150.3200 TECHNIQUES FOR TEMPORARY EROSION & SEDIMENT CONTROL EROSION & SEDIMENT CONTROL SHALL BE PER PSE STANDARD PRACTICE & ANY ADDITIONAL LOCAL JURISDICTION REQUIREMENTS. FOREMAN (CHECK BOX WHEN COMPLETED) PSE Equipment LOCKED/SECURED & Work Area left in CLEAN/SAFE Condition. Grid, Cable, and Switch numbers INSTALLED & VERIFIED. Field Changes RED-LINED on As-built. Indicate correct FUSE SIZE on As-built & VERIFY proper PHASE. Foreman's Signature _______________________________________________ Print Name ___________________________________ Date ______________ Material VERIFIED and CHANGES noted on Paperwork. Total PRIMARY Cable noted on As-built. Company ID#'s RECORDED in correct location on As-built. Deviations noted on the As-built and their reason. I certify that the work performed meets PSE's standards and procedures and that all quality requirements are met. GAS PHONE CABLE TV 504547479 101105002 N/A 108100584 N/A N/A N/A N/A N/A N/A N/A N/A N/A N/A N/A N/A N/A N/A PROJECT PHASE PWR NOTIF#ORDER# Superior Perm. Service Relocation Removal Temporary Job Order Distribution HP Main HP Svc/MSA DESIGNED BY UTILITIES CONTACT PHONE# COUNTY 1/4 SEC U-MAP NO (POWER) OP MAP Emer Sect Gas Wk Ctr POWER WK CTR PLAT MAP JOINT FACILITIES ARRANGEMENTS DRAWN BY CHECKED BY APPROVED BY FOREMAN #1 FOREMAN #2 MAPPING INCIDENT MAOP Gas Order Elect Order SCALE PAGE ENGR - POWER ENGR - GAS FUNCTION PROJECT MGR PERMITREAL ESTATE/EASEMENT 2 1 REV# 3 DATE DESCRIPTIONBY CONTACT PHONE NO DATE OH CKT MAP CIRCUIT NOUG CKT MAP D. KUMAR (425) 516-5486 4/28/17 NATE LINVILLE (253) 970-7284 4/28/17 N/A N/A N/A NATE LINVILLE (253) 970-7284 REQUIRED RENTON IKEA - VAULT RELOCATION REMOVE 3Ø JVAULT, INST. 2 - 3Ø VAULT, 601 SW 41ST ST, RENTON, WA 98057 PUGET SOUND ENERGY N/A N/A N/A 101105002 AS NOTED 1 OF 1 KING N/A N/A CSPSKEPM NW-31-23-05E N/A N/A 2305E122 2305E124 2305E122 VIC-17 N/A N/A N/A N/A N/A N/A N/A N/A N/A N/A N/A N/A SCALE: 6" = 1 MILE UNDERGROUND CIRCUIT MAP POWER GENERAL NOTES - COMMERCIAL PROJECT 8. EXCAVATION: The customer is to provide all trenching, backfill, vault excavations, compaction and restoration per this sketch and per PSE standards. A minimum protective cover of 36" is required over PSE's primary voltage equipment and 24" is required of PSE's secondary voltage equipment. The customer will provide any and all shoring or they will side slope the trench to 1:1. All materials to be installed in accordance with Puget Sound Energy's (PSE) standards. Any deviation from this work sketch must be AUTHORIZED by PSE's Project Manager and NOTED on the Foremans' Copy. All switching arrangements and/or outage arrangements are to be made with the Project Manager at least three (3) working days in advance. Contact the Utilities Underground Location Center (1-800-424-5555) at least 48 hours prior to commencing work to get the underground facilities located. STAKING: The customer will provide all staking (transformer, handhole, trench, grade, lot, pole, sidewalk, etc.). See sketch and details for locations. Equipment locations must be approved by the Project Manager. SITE PREPARATION: The work area will be at or near finished grade, clear of trench spoils or construction materials which would restrict construction and/or equipment access, before work can begin. Roads shall be paved or have a compacted , crushed rock base in place. CLEARANCES: Transformers require a minimum of 6 feet from fire fighting equipment, 10 feet from combustible walls, overhangs, doors, and windows, and a minimum of 5 feet from the back of curb (or guard posts will be required per PSE standards). All conduits and vaults are to be at least 5 feet away from water, storm and sewer lines when paralleling them in the right of way, and at least 1 foot when crossing them. All work is to be done in accordance with local municipal and county permit requirements as applicable. Customer/Developer is responsible to provide, install and maintain all secondary service cables, conduits and crossings from the individual unit's meter base to the designated connection point. Inclement weather conditions may cause delays in construction times and dates. 1. 2. 3. 4. 5. 6. 7. 9. 11. 10. PSE No No No Yes Yes Yes No YesDeveloper "Flagging Required" "Outages Required" "Locates Required" E-Mail: Cell Phone: Project Manager Contact Information: Manager:DEVENDRA KUMAR (425) 516-5486 DEVENDRA.KUMAR@PSE.COM N Vicinity Map N/A AT J01: EXISTING REMOVE EXISTING 575 VAULT, LID, AND JBUS ABANDON EXISTING CABLES IN PLACE AT J02: NEW -INSTALL 5' X 7' X 5' VAULT & LID 6055.1030 (JB0X15L) -INSTALL 3- 4POS J-BOX -INSTALL 6- L/B ELBOWS & 6- DUST CAPS 6041.1000 (ELB10J) -INSTALL GRID 316477-165628 AT J03: NEW -INSTALL 5' X 7' X 5' VAULT & LID 6055.1030 (JB0X15L) -INSTALL 3- 4POS J-BOX -INSTALL 6- L/B ELBOWS & 6- DUST CAPS 6041.1000 (ELB10J) -INSTALL GRID 316461-165628 SPAN NOTES: IP1 TO J01 -INTERCEPT EXISTING CABLES AØACE543, BØACE544, CØACE545 RE-ROUTE TO J02 J02 TO J03 -INST. 3 - 1/0 AL SOL JKT CABLES 160'± ____ACTUAL -INST. CABLE TAGS AØEHM618, BØEHM619, CØEHM620 IP2 T0 J03 -INTERCEPT EXISTING CABLES AØAGI337, BØAGI338, CØAGI339 RE-ROUTE TO J03 THREE PH PRIMARY J-BOX DETAIL 6055.1030-01Not to scale 7'-0" 4'-8" 4'-0" 1'-0" Internal vault ground installed by manufacturer 4760 lbs Two 3' Sq Std Plate Doors 2490 lbS Base Cover TRENCH DETAIL Electric Service Cable in Conduit (NTS) Electric Service Cable in Conduit Excavated Dirt Pile Final Grade 24" Min 24" Min to 36" Max Cover 12" Typical (6" Min) Backfill for Conduit Free of rocks larger than 8" in diameter) 36" MINIMUM COVER IN RIGHT OF WAY To Excavated Dirt Pile 3" Schedule 40 Grey PVC Backfill for In Conduit - The backfill layer shall be soil that is free from construction debris, glass, sharp rocks, frozen clods, and rocks larger than 8" in diameter. SCALE: 1" = 20' CUSTOMER TO REMOVE BRUSH AROUND TRANSFORMER