Loading...
HomeMy WebLinkAboutP_Utility Plan_101105002_V1-170510LIND AVE SW316471-165629 316474-165628 316465-165628 316471-165641 WORK ZONE SE 43RD ST SW 43RD ST LIND AVE SWSW 41ST ST WORK ZONE SITE PLAN Owner / Developer Contact Info officeATTN: IKEA PROPERTY INC 420 ALAN WOOD RD CONSHOHOKEN, PA 19428 JIM MEYER (425) 484-4100 101105002THIS SKETCH NOT TO BE RELIED UPON FOR EXACT LOCATION OF EXISTING FACILITIES CALL (800) 424-5555 2 BUSINESS DAYS BEFORE YOU DIG For contacts below dial 1-888-CALL PSE (225-5773) SITE SPECIFIC NOTES OVERHEAD CIRCUIT MAP(2305E124) SCALE: 6" = 1 MILE CIRCUIT FEET REMOVED: 160' ARE TO BE INSTALLED, CROSS SECTION DETAILS OF THE TYPICAL EROSION STRUCTURES, & SPECIAL REQUIREMENTS FOR WORK IN SENSITIVE AREAS.) EROSION & SEDIMENT CONTROL REQUIREMENTS NOTES DETAILING WHERE EROSION OR SEDIMENT CONTROL STRUCTURES (LOCAL JURISDICTIONS MAY HAVE ADDITIONAL REQUIREMENTS INCLUDING 0150.3200 TECHNIQUES FOR TEMPORARY EROSION & SEDIMENT CONTROL EROSION & SEDIMENT CONTROL SHALL BE PER PSE STANDARD PRACTICE & ANY ADDITIONAL LOCAL JURISDICTION REQUIREMENTS. FOREMAN (CHECK BOX WHEN COMPLETED) PSE Equipment LOCKED/SECURED & Work Area left in CLEAN/SAFE Condition. Grid, Cable, and Switch numbers INSTALLED & VERIFIED. Field Changes RED-LINED on As-built. Indicate correct FUSE SIZE on As-built & VERIFY proper PHASE. Foreman's Signature _______________________________________________ Print Name ___________________________________ Date ______________ Material VERIFIED and CHANGES noted on Paperwork. Total PRIMARY Cable noted on As-built. Company ID#'s RECORDED in correct location on As-built. Deviations noted on the As-built and their reason. I certify that the work performed meets PSE's standards and procedures and that all quality requirements are met. GAS PHONE CABLE TV 504547479 101105002 N/A 108100584 N/A N/A N/A N/A N/A N/A N/A N/A N/A N/A N/A N/A N/A N/A PROJECT PHASE PWR NOTIF#ORDER# Superior Perm. Service Relocation Removal Temporary Job Order Distribution HP Main HP Svc/MSA DESIGNED BY UTILITIES CONTACT PHONE# COUNTY 1/4 SEC U-MAP NO (POWER) OP MAP Emer Sect Gas Wk Ctr POWER WK CTR PLAT MAP JOINT FACILITIES ARRANGEMENTS DRAWN BY CHECKED BY APPROVED BY FOREMAN #1 FOREMAN #2 MAPPING INCIDENT MAOP Gas Order Elect Order SCALE PAGE ENGR - POWER ENGR - GAS FUNCTION PROJECT MGR PERMITREAL ESTATE/EASEMENT 2 1 REV# 3 DATE DESCRIPTIONBY CONTACT PHONE NO DATE OH CKT MAP CIRCUIT NOUG CKT MAP D. KUMAR (425) 516-5486 4/28/17 NATE LINVILLE (253) 970-7284 4/28/17 N/A N/A N/A NATE LINVILLE (253) 970-7284 REQUIRED RENTON IKEA - VAULT RELOCATION REMOVE 3Ø JVAULT, INST. 2 - 3Ø VAULT, 601 SW 41ST ST, RENTON, WA 98057 PUGET SOUND ENERGY N/A N/A N/A 101105002 AS NOTED 1 OF 1 KING N/A N/A CSPSKEPM NW-31-23-05E N/A N/A 2305E122 2305E124 2305E122 VIC-17 N/A N/A N/A N/A N/A N/A N/A N/A N/A N/A N/A N/A SCALE: 6" = 1 MILE UNDERGROUND CIRCUIT MAP POWER GENERAL NOTES - COMMERCIAL PROJECT 8. EXCAVATION: The customer is to provide all trenching, backfill, vault excavations, compaction and restoration per this sketch and per PSE standards. A minimum protective cover of 36" is required over PSE's primary voltage equipment and 24" is required of PSE's secondary voltage equipment. The customer will provide any and all shoring or they will side slope the trench to 1:1. All materials to be installed in accordance with Puget Sound Energy's (PSE) standards. Any deviation from this work sketch must be AUTHORIZED by PSE's Project Manager and NOTED on the Foremans' Copy. All switching arrangements and/or outage arrangements are to be made with the Project Manager at least three (3) working days in advance. Contact the Utilities Underground Location Center (1-800-424-5555) at least 48 hours prior to commencing work to get the underground facilities located. STAKING: The customer will provide all staking (transformer, handhole, trench, grade, lot, pole, sidewalk, etc.). See sketch and details for locations. Equipment locations must be approved by the Project Manager. SITE PREPARATION: The work area will be at or near finished grade, clear of trench spoils or construction materials which would restrict construction and/or equipment access, before work can begin. Roads shall be paved or have a compacted , crushed rock base in place. CLEARANCES: Transformers require a minimum of 6 feet from fire fighting equipment, 10 feet from combustible walls, overhangs, doors, and windows, and a minimum of 5 feet from the back of curb (or guard posts will be required per PSE standards). All conduits and vaults are to be at least 5 feet away from water, storm and sewer lines when paralleling them in the right of way, and at least 1 foot when crossing them. All work is to be done in accordance with local municipal and county permit requirements as applicable. Customer/Developer is responsible to provide, install and maintain all secondary service cables, conduits and crossings from the individual unit's meter base to the designated connection point. Inclement weather conditions may cause delays in construction times and dates. 1. 2. 3. 4. 5. 6. 7. 9. 11. 10. PSE No No No Yes Yes Yes No YesDeveloper "Flagging Required" "Outages Required" "Locates Required" E-Mail: Cell Phone: Project Manager Contact Information: Manager:DEVENDRA KUMAR (425) 516-5486 DEVENDRA.KUMAR@PSE.COM N Vicinity Map N/A AT J01: EXISTING REMOVE EXISTING 575 VAULT, LID, AND JBUS ABANDON EXISTING CABLES IN PLACE AT J02: NEW -INSTALL 5' X 7' X 5' VAULT & LID 6055.1030 (JB0X15L) -INSTALL 3- 4POS J-BOX -INSTALL 6- L/B ELBOWS & 6- DUST CAPS 6041.1000 (ELB10J) -INSTALL GRID 316477-165628 AT J03: NEW -INSTALL 5' X 7' X 5' VAULT & LID 6055.1030 (JB0X15L) -INSTALL 3- 4POS J-BOX -INSTALL 6- L/B ELBOWS & 6- DUST CAPS 6041.1000 (ELB10J) -INSTALL GRID 316461-165628 SPAN NOTES: IP1 TO J01 -INTERCEPT EXISTING CABLES AØACE543, BØACE544, CØACE545 RE-ROUTE TO J02 J02 TO J03 -INST. 3 - 1/0 AL SOL JKT CABLES 160'± ____ACTUAL -INST. CABLE TAGS AØEHM618, BØEHM619, CØEHM620 IP2 T0 J03 -INTERCEPT EXISTING CABLES AØAGI337, BØAGI338, CØAGI339 RE-ROUTE TO J03 THREE PH PRIMARY J-BOX DETAIL 6055.1030-01Not to scale 7'-0" 4'-8" 4'-0" 1'-0" Internal vault ground installed by manufacturer 4760 lbs Two 3' Sq Std Plate Doors 2490 lbS Base Cover TRENCH DETAIL Electric Service Cable in Conduit (NTS) Electric Service Cable in Conduit Excavated Dirt Pile Final Grade 24" Min 24" Min to 36" Max Cover 12" Typical (6" Min) Backfill for Conduit Free of rocks larger than 8" in diameter) 36" MINIMUM COVER IN RIGHT OF WAY To Excavated Dirt Pile 3" Schedule 40 Grey PVC Backfill for In Conduit - The backfill layer shall be soil that is free from construction debris, glass, sharp rocks, frozen clods, and rocks larger than 8" in diameter. SCALE: 1" = 20' CUSTOMER TO REMOVE BRUSH AROUND TRANSFORMER