Loading...
HomeMy WebLinkAboutP_Utility Plan_186048176_V1_170517I 00 lwq- t0 00 v U O Q / d- 000 Q0 0 0 4-1C N 0 c0 r dq- 00 0 N 0 a V) C_ I LLI (n I 0 X E CLd- I 0 N N Q SITE PLAN: P01 & P02_ ISCALE: 1:100 Z TABLE (NEW) Site # Z 3812 Grid # Height 766 •18271-1 o 3301 3307 66884 50 1 3407 3413 3425 3 i z 1 3 7.5kVA 12o1240v 3313 PSE Equip # 3331 3401 3419 318365-16699 318366-167020 1 m A 3319 3325 318351-167024 25kVA 1201240v LINK 1953 ' i ' i D i < i m 762 CHECKED BY w 318359-167035 N/A N/A QCSOKE i 249-166 8 M ( 3304 3310 318250-166854 3322 3328 APPROVED BY 3410 3404 3422 2 0 QT 758 OH CKT MAP 3334 N S� 3416 3428 i %T31/2 318250 BCN (Po'� 318250-166884 MAPPING JOINT FACILITIES ARRANGEMENTS 01NETT UTILITIES 16 6 8 6 8 37.5kVA 120/24ov N/A 318250-166916 318249-166925 U N/A kVA 1201240vc� PHONE# N/A N/A N/A 25kVA 1201240v X77903 SOUNDGas ENERGY i 336.4 MCMACSR e � 1:100 1/1 407 co 318242-166868 NE 6TH ST 754 31 8 2 cJ 0 37.5kVA � QP Q 2 120/240v 3706 i 2 1007 � 166900 3809 j2 X174 3719 i r11__3303 \� 3801 i NE 7TH ST 577 1 #2ACSR � #4W 579 31827-166862318230-1 687 R' 574 3407 318340-166995 C7- 3309 I ��o -- 25kVA 120/240v __ ti 318242-166923 Tn 25kVA 1201240 i i 3 a 572 fi fr / 571 SITE PLAN: P01 & P02_ ISCALE: 1:100 SITE PLAN: P03- I SCALE: 1:100 EROSION &SEDIMENT CONTROL REQUIREMENTS EROSION & SEDIMENT CONTROL SHALL BE PER PSE STANDARD PRACTICE 0150.3200 TECHNIQUES FOR TEMPORARY EROSION &SEDIMENT CONTROL & ANY ADDITIONAL LOCAL JURISDICTION REQUIREMENTS. (LOCAL JURISDICTIONS MAY HAVE ADDITIONAL REQUIREMENTS INCLUDING NOTES DETAILING WHERE EROSION OR SEDIMENT CONTROL STRUCTURES ARE TO BE INSTALLED, CROSS SECTION DETAILS OF THE TYPICAL EROSION STRUCTURES, & SPECIAL REQUIREMENTS FOR WORK IN SENSITIVE AREAS.) SITE SPECIFIC NOTES P01: 318250-166868 (TREE TRIMMING REQUIRED) - INSTALL NEW 50' CL -1 POLE WITH GROUNDS - INSTALL NEW HD 11' DBL CROSSARMS W/ 2 P&G STD# 6033.3060 (DEP315) - INSTALL NEW 30 336.4MCMSACSR PRIMARY NEUTRAL DEADENDS EAST - INSTALL NEW STD 11' SGL CROSSARM W/ 6 P&G STD# 6033.3022 (TAPD313) - INSTALL NEW 7/16" PRIMARY DOWN GUY TO EXISTING ANCHOR NORTH - INSTALL NEW RIGID CLEVIS EAST - TRANSFER'PRIMARY SPAN GUY WEST - TRANSFER & RECONNECT OH TRIPLEX - TRANSFER & RECONNECT STREETLIGHT - COMMUNICATIONS TO TRANSFER THEIR OWNS WIRES & EQUIPMENT - REMOVE & RETIRE EXISTING 45'1962 CLA POLE P02: 318250-166900 RAISE EXISTING STREETLIGHT 6" CLEAN UP/TIGHTEN UP DRIP LOOPS P03: 318351-167024 - INSTALL NEW 45' CL -3 POLE WITH GROUNDS - INSTALL NEW 10 PTP - INSTALL NEW 10 ARM MOUNTED #2ACSR LATERAL TAP FUSED @ 40T - INSTALL NEW COMMON NEUTRAL RIGID CLEVIS - INSTALL 2 NEW 3/8" DOWN GUYS TO EXISTING ANCHOR SOUTH (1- PRI, 1- NEU) - INSTALL NEW RIGID CLEVIS EAST - INSTALL NEW SW# X78639 - TRANSFER & RECONNECT OH TRIPLEX - TRANSFER & RECONNECT STREETLIGHT - COMMUNICATIONS TO TRANSFER THEIR OWNS WIRES & EQUIPMENT - REMOVE & RETIRE EXISTING 40'1953 POLE Z TABLE (NEW) Site # Z 3812 Grid # Height 766 Year W P01 318250-166868 50 1 759 B > 760 4 3 LU Z 1 3 2017 PSE Equip # (101095644) El z 318365-16699 318366-167020 0 318363-167050 318364 DESCRIPTION P03 318351-167024 25kVA 1201240v LINK 1953 POWER WK CTR w LJJ 762 CHECKED BY w 318359-167035 N/A N/A QCSOKE 1/4 SEC OP MAP 50kVA 120/240v 759 APPROVED BY / 755 3800 N/A N/A 758 OH CKT MAP UG CKT MAP N S� FOREMAN #2 2305EO39 751 2305EO39 PRE -11 MAPPING JOINT FACILITIES ARRANGEMENTS 01NETT UTILITIES 18355-166995 N/A N/A N/A N/A U N/A kVA 1201240vc� PHONE# N/A N/A N/A N/A PUGU PRE -1 1 CENTURYLINK RENTON 55 SOUNDGas ENERGY REPLACE POLE, RAISE STREET LIGHTS 3304 NE 6TH ST RENTON WA 98056 3712 e � 1:100 1/1 407 754 318351 P03167024 3624 v 3706 SW# X78639 � 3809 3719 3805 3801 NE 7TH ST 3715 #2ACSR � #4W � 318338-167018 318340-166995 C7- 25kVA 120/240v SITE PLAN: P03- I SCALE: 1:100 EROSION &SEDIMENT CONTROL REQUIREMENTS EROSION & SEDIMENT CONTROL SHALL BE PER PSE STANDARD PRACTICE 0150.3200 TECHNIQUES FOR TEMPORARY EROSION &SEDIMENT CONTROL & ANY ADDITIONAL LOCAL JURISDICTION REQUIREMENTS. (LOCAL JURISDICTIONS MAY HAVE ADDITIONAL REQUIREMENTS INCLUDING NOTES DETAILING WHERE EROSION OR SEDIMENT CONTROL STRUCTURES ARE TO BE INSTALLED, CROSS SECTION DETAILS OF THE TYPICAL EROSION STRUCTURES, & SPECIAL REQUIREMENTS FOR WORK IN SENSITIVE AREAS.) SITE SPECIFIC NOTES P01: 318250-166868 (TREE TRIMMING REQUIRED) - INSTALL NEW 50' CL -1 POLE WITH GROUNDS - INSTALL NEW HD 11' DBL CROSSARMS W/ 2 P&G STD# 6033.3060 (DEP315) - INSTALL NEW 30 336.4MCMSACSR PRIMARY NEUTRAL DEADENDS EAST - INSTALL NEW STD 11' SGL CROSSARM W/ 6 P&G STD# 6033.3022 (TAPD313) - INSTALL NEW 7/16" PRIMARY DOWN GUY TO EXISTING ANCHOR NORTH - INSTALL NEW RIGID CLEVIS EAST - TRANSFER'PRIMARY SPAN GUY WEST - TRANSFER & RECONNECT OH TRIPLEX - TRANSFER & RECONNECT STREETLIGHT - COMMUNICATIONS TO TRANSFER THEIR OWNS WIRES & EQUIPMENT - REMOVE & RETIRE EXISTING 45'1962 CLA POLE P02: 318250-166900 RAISE EXISTING STREETLIGHT 6" CLEAN UP/TIGHTEN UP DRIP LOOPS P03: 318351-167024 - INSTALL NEW 45' CL -3 POLE WITH GROUNDS - INSTALL NEW 10 PTP - INSTALL NEW 10 ARM MOUNTED #2ACSR LATERAL TAP FUSED @ 40T - INSTALL NEW COMMON NEUTRAL RIGID CLEVIS - INSTALL 2 NEW 3/8" DOWN GUYS TO EXISTING ANCHOR SOUTH (1- PRI, 1- NEU) - INSTALL NEW RIGID CLEVIS EAST - INSTALL NEW SW# X78639 - TRANSFER & RECONNECT OH TRIPLEX - TRANSFER & RECONNECT STREETLIGHT - COMMUNICATIONS TO TRANSFER THEIR OWNS WIRES & EQUIPMENT - REMOVE & RETIRE EXISTING 40'1953 POLE POWER GENERAL NOTES 1.. All materials to be installed in accordance with Puget Sound Energy's (PSE) standards. Any deviation from this work sketch must be AUTHORIZED by Potelco's Project Manager and NOTED on the Foremans' Copy. 2. All switching arrangements and/or outage arrangements are to be made with the Project Manager at least three (3) working days in advance. 3. Contact the Utilities Underground Location Center (1-800-424-5555) at least 48 hours prior to commencing work to get the underground facilities located. 4. All work is to be done in accordance with focal municipal and county permit requirements as applicable. 5. Inclement weather conditions may cause delays in construction times and dates. L -t,. I C •-25 c� C 80K o�0 65 �`�O �hh0 �V _ _ I 1 t� �• 1 I • Z I Q rn r 1 257 p C 1 � 030 I q-�ut AO _�_.♦ Z AO r 1 X-07091- _ _ — HIG ..•., X1503 657' W oGo <. •'- 1007 1100T X100 40T p 407 C NE 18 ST Q •'' " •''' Q I A '� X �' NE /O LN 257 X766 X11307 • 1 q3 �6 C •• •30 40T--__..___B::-:-:00900*A C , ;3 0 wo p I Q 65T 1 NE ! A A 40T X12082:C ; ; • • • • • X4M _ _B _ y 3 .. PRE Mo Q 1 - - - . , o _ .� O ST - = 257 . � :407 . x rn O X9848 -IN c A r — 000.0... •..• • C) I ��NE 9 PL, i AIS 11 O I - - - .1 WN�B T A ,40i' • 6 Co. A 657 ------ �p 0000• 1 WIVai A . ° : '< I X9850 -f cK .A 0000.. NE 9 ST 4U I ;•• I 40TX9604 257 0.00.• _ _ _ r 5T _ .:.� ~� �o o . 10755 1 657 4 I 1 — — — — ORS 4t '� � i t A •... X9673 e� � � �x -r �I �' 1 � �. � � '407 0000. � 657 ____' �- ao wN�' 9 --�- a ., X0812 �, 3� • 4OT 1 1 Np s'�" I 1 1007 + d I 1 C� X9411 257 131 - � e 1 I 25 JOB SITES I C f X25 X10231 yONEYDEW ' 25 ` . Sr I B0 100T. '25T .%� G / - -1- -L _ -{ 1�• -- PRE .1007 ELE'V �25 , -, A I D 6985 I , „ :......:3 X678 N 65 X857 3�'� 407 !A IA /NK442 ; o� I C ,,,_ IC A� N E HiCHLAN S B •. •• 1 %6 xo WNL ` A ......r... A`' 6 p� r 25 ELEM NE ' 8 S R 65T _ c��r _ T-„f�B WN -V Q A NE: ,.,,• �� 257 1OOT X1930 39� 65T 00 B 40�T.' � 1000387 1 y 25 40T • t I 65T • • L 'f WNL CK00368 • • , • „� 257 �� I HiG 100 C wN� T' I A ., B B . A � Qr-- c �� a �� B1� �s 657 X1929 l- T PiL_Z ��.. A INE 6 f', L. �t ♦ 48 lop 1 ?5 C 5T �: 0000.7D� T ?>40T I �.. I ♦ w0 I A W Z I AVS' S PL '* r tM' -- -, B •,o L 1 •• ��F `I•�&% A � � 1 0 - - 1- - -L 1 . 5! I I v A 1007 C042601 CK00367 B • T. C _ _ 407 w ` _ � a'p I I J X77903 X233 © 65 257 6 C i • fi5T I= L I 0000..• g• • 257 X111121 �� i >1 X1742 ':,• CK275 /j/�" 6 ST �""' :"'•••� goo X103591 f'' o 'S PT - @C03551 NE A' 100T ; ;C ;•• 25TA W •........:::' OOT 0000.• g•� C; I' IW l s C .. ; A • X2949 1 C C t NESPL 35�: 407 r.� � PRE � a '""'' A ' -%31lOT • 0 1,.30... ... . : evoc, a sees 407 I A :� ! A♦x A 407 �; ; ... . • : •.::• g:... : A � � I . .g � � � �;•• B .. PRE 11 0 •C X881 Q ' o ♦ 407 ...._:....• 14 B. �n �,� 3 0 . X6906 .13 X9569 3 : 3 S 0128 :0000 T •• 3� ' • 3 S� •. • 12 9570 3 ' ;...i 0000. ., = �� , ; •, : ; g... '0000 ,.: �• •) •' •.V g:..: 1fERNDA X363 '- :e "-0- 30 30 ti`�'`oo� •. 3� • . •........ .... OVERHEAD CIRCUIT MAP. NOT TO SCALE POLE RETIREMENT TABLE POLE TABLE (NEW) Site # POLE DATA Pole Data Grid # Height Class Year Remarks /Location Ref. P01 318250-166868 50 1 2017 PSE Equip # P03 318351-167024 45 1 3 2017 PSE Equip # POWER GENERAL NOTES 1.. All materials to be installed in accordance with Puget Sound Energy's (PSE) standards. Any deviation from this work sketch must be AUTHORIZED by Potelco's Project Manager and NOTED on the Foremans' Copy. 2. All switching arrangements and/or outage arrangements are to be made with the Project Manager at least three (3) working days in advance. 3. Contact the Utilities Underground Location Center (1-800-424-5555) at least 48 hours prior to commencing work to get the underground facilities located. 4. All work is to be done in accordance with focal municipal and county permit requirements as applicable. 5. Inclement weather conditions may cause delays in construction times and dates. L -t,. I C •-25 c� C 80K o�0 65 �`�O �hh0 �V _ _ I 1 t� �• 1 I • Z I Q rn r 1 257 p C 1 � 030 I q-�ut AO _�_.♦ Z AO r 1 X-07091- _ _ — HIG ..•., X1503 657' W oGo <. •'- 1007 1100T X100 40T p 407 C NE 18 ST Q •'' " •''' Q I A '� X �' NE /O LN 257 X766 X11307 • 1 q3 �6 C •• •30 40T--__..___B::-:-:00900*A C , ;3 0 wo p I Q 65T 1 NE ! A A 40T X12082:C ; ; • • • • • X4M _ _B _ y 3 .. PRE Mo Q 1 - - - . , o _ .� O ST - = 257 . � :407 . x rn O X9848 -IN c A r — 000.0... •..• • C) I ��NE 9 PL, i AIS 11 O I - - - .1 WN�B T A ,40i' • 6 Co. A 657 ------ �p 0000• 1 WIVai A . ° : '< I X9850 -f cK .A 0000.. NE 9 ST 4U I ;•• I 40TX9604 257 0.00.• _ _ _ r 5T _ .:.� ~� �o o . 10755 1 657 4 I 1 — — — — ORS 4t '� � i t A •... X9673 e� � � �x -r �I �' 1 � �. � � '407 0000. � 657 ____' �- ao wN�' 9 --�- a ., X0812 �, 3� • 4OT 1 1 Np s'�" I 1 1007 + d I 1 C� X9411 257 131 - � e 1 I 25 JOB SITES I C f X25 X10231 yONEYDEW ' 25 ` . Sr I B0 100T. '25T .%� G / - -1- -L _ -{ 1�• -- PRE .1007 ELE'V �25 , -, A I D 6985 I , „ :......:3 X678 N 65 X857 3�'� 407 !A IA /NK442 ; o� I C ,,,_ IC A� N E HiCHLAN S B •. •• 1 %6 xo WNL ` A ......r... A`' 6 p� r 25 ELEM NE ' 8 S R 65T _ c��r _ T-„f�B WN -V Q A NE: ,.,,• �� 257 1OOT X1930 39� 65T 00 B 40�T.' � 1000387 1 y 25 40T • t I 65T • • L 'f WNL CK00368 • • , • „� 257 �� I HiG 100 C wN� T' I A ., B B . A � Qr-- c �� a �� B1� �s 657 X1929 l- T PiL_Z ��.. A INE 6 f', L. �t ♦ 48 lop 1 ?5 C 5T �: 0000.7D� T ?>40T I �.. I ♦ w0 I A W Z I AVS' S PL '* r tM' -- -, B •,o L 1 •• ��F `I•�&% A � � 1 0 - - 1- - -L 1 . 5! I I v A 1007 C042601 CK00367 B • T. C _ _ 407 w ` _ � a'p I I J X77903 X233 © 65 257 6 C i • fi5T I= L I 0000..• g• • 257 X111121 �� i >1 X1742 ':,• CK275 /j/�" 6 ST �""' :"'•••� goo X103591 f'' o 'S PT - @C03551 NE A' 100T ; ;C ;•• 25TA W •........:::' OOT 0000.• g•� C; I' IW l s C .. ; A • X2949 1 C C t NESPL 35�: 407 r.� � PRE � a '""'' A ' -%31lOT • 0 1,.30... ... . : evoc, a sees 407 I A :� ! A♦x A 407 �; ; ... . • : •.::• g:... : A � � I . .g � � � �;•• B .. PRE 11 0 •C X881 Q ' o ♦ 407 ...._:....• 14 B. �n �,� 3 0 . X6906 .13 X9569 3 : 3 S 0128 :0000 T •• 3� ' • 3 S� •. • 12 9570 3 ' ;...i 0000. ., = �� , ; •, : ; g... '0000 ,.: �• •) •' •.V g:..: 1fERNDA X363 '- :e "-0- 30 30 ti`�'`oo� •. 3� • . •........ .... OVERHEAD CIRCUIT MAP. NOT TO SCALE POLE RETIREMENT TABLE TEMP TRANSFERS ST. LIGHT TRANSFERS SITE # POLE DATA POLE TEL TV FIBER TRAN RMVD ID NUMBER GRID # HEIGHT CLASS YEAR TOPPED RMVD P01 318250-166868 45 1 1962 El El El El 0 El DESCRIPTION P03 318351-167024 40 LINK 1953 POWER WK CTR DRAWN BY BAUGHN 253.327.3162 4/10/17 CHECKED BY KING N/A N/A ENGR-1: # 106784 FOREMAN (CHECK BOX WHEN COMPLETED) ❑ PSE Equipment LOCKED/SECURED & Work Area left in CLEAN/SAFE Condition. ❑ Grid, Cable, and Switch numbers INSTALLED & VERIFIED. ❑ Field Changes RED -LINED on As -built. ❑ Material VERIFIED and CHANGES noted on Paperwork. ❑ Total PRIMARY Cable noted on As -built. ❑ Company ID#'s RECORDED in correct location on As -built. ❑ Indicate correct FUSE SIZE on As -built & VERIFY proper PHASE. ❑ Deviations noted on the As -built and their reason. ❑ I certify that the work performed meets PSE's standards and procedures and that all quality requirements are met. Foreman's Signature Print Name Date PROJECT PHASE NOTIF# ORDER# PWR Superior Installation Removal Expense 504191257 186048176 N/A 101105125 N/A 108100560 N/A 186048670 Vicinity Map N/A _ A�_w...NESt ft .. `♦ si SLwvwM.aY.'�N.v'. '- a.lj.+..t _ ;.._ _� - ry..J(..", � r '. i'` �.tf•.i-' e_�t- •�SYgnfw.4..-�E17th Sl! • - `, _ - _ - -,.ref 771 —7- s _ _ s • _ _ — i r £ j. }. drys ..sa..7.; 0. :-NE-4 - T 11ODS, +� 2 rel I Mills A9A-r%r%r%s Developer Yes Yes X PSE 2 BUSINESS DAYS BEFORE YOU DIG "Locates Required" No X No THIS SKETCH NOT TO BE RELIED UPON FOR EXACT LOCATION OF EXISTING FACILITIES "Outages Required" Yes x No REAL ESTATE/EASEMENT PERMIT "Flagging Required" Yes x No N/A CITY OF RENTON 3 FUNCTION CONTACT PHONE NO DATE 2 PROJECT MGR SIERRA VEGA 253.327.3162 4/10/17 1 ENGR - POWER SIERRA VEGA 253.327.3162 4/10/17 REV# DATE BY DESCRIPTION ENGR - GAS N/A N/A N/A COUNTY Emer Sect Gas Wk Ctr POWER WK CTR DRAWN BY BAUGHN 253.327.3162 4/10/17 CHECKED BY KING N/A N/A QCSOKE 1/4 SEC OP MAP PLAT MAP APPROVED BY / FOREMAN #1 10 -SW T23N R05E N/A N/A U -MAP NO (POWER) OH CKT MAP UG CKT MAP CIRCUIT NO FOREMAN #2 2305EO39 2305EO40 2305EO39 PRE -11 MAPPING JOINT FACILITIES ARRANGEMENTS UTILITIES N/A N/A N/A N/A N/A N/A N/A N/A CONTACT PHONE# N/A N/A N/A N/A PUGU PRE -1 1 CENTURYLINK RENTON INCIDENT MAOP N/A N/A SOUNDGas ENERGY REPLACE POLE, RAISE STREET LIGHTS 3304 NE 6TH ST RENTON WA 98056 Order Elect Order NIA 186048176 SCALE PAGE DESIGNED BY POTELCO 1:100 1/1