Loading...
HomeMy WebLinkAboutP_Sketch_101101327-V1_170525PSE GENERAL SPECIFICATIONS ABANDONING PRIMARY CABLES PSE std. 6825.6200 General In a Vault if the cable is Existing Utilities: - All work is to be completed per PSE Standards & Practices. Copies of all PSE Standards Hand excavate (pothole) all marked utility crossings to verify exact location and depth at point 7. Remove all "Danger Do Not Operate" tags. are available upon request. In conduit, -Remove the cable - Work sites shall be kept clear of debris and all construction materials, equipment and Not in conduit or it cannot be pulled out, -Cut the cable off approximately one foot packing shall be removed daily. Maintain existing electrical system in service until new system is complete, tested, and ready* for service. from the vault wall. - Return all unused and removed poles, transformers and hardware to PSE, storeroom. All installations. Transition trench or tunnel profile gradually as required at crossings. Maintain -When practical, attach the old cable copper shall be coiled and returned the day it is removed from the poles. Remove all unused The general scope of this project is to remediate primary 1/0 cables within the project area by the most economic number to the cable stub. pins and insulators. Excavation The project involves replacing existing electrical cables in new conduit. - Return all Street lights, area lights and floodlights to Sumner yard. In a Minipad hand hole 36" of cover for primary conductors and 24" of cover for secondary conductors. - All fault indicators will be maintained in their current location on the 1/0 cables upon - Road crossings and all trenches within the Right-of-way shall be of sufficient depth to Project location: 1805 GRANT AVE S., RENTON, WA 98055 completion of the job. If it is noted to remove any of the indicators they shall be returned to In conduit, -Remove the cable local PSE first response department for re -issue. - Back fill in road crossings and within the Right-of-way shall be compacted to 95% density or Cable Footage Estimated : 5,035' Preconstruction Not in conduit or it cannot be pulled out, -Cut the cable off as much as practical Cable Numbers Repaired: 0 #2 Print Name -When practical, attach the old cable number to - Notify appropriate city, County or DOT authorities 48 to 72 hours, or as required by Cable Numbers Replaced : 3430-32, 3983, 3975, 16079, 16080, ABD078, 3544-51, 10442, 4590-95 the cable stub. permitting agency, in advance of starting work in Right-of-way involving a Permit. - Vaults shall be placed level and 2" above final grade in landscaped areas and flush with -Stuff the tail into the bottom of the - All system switching shall be approved by System Operations (425-882-4652) a minimum 24-hour advance notice of no parking in work areas. Access will be maintained to all residences and their handhole. Be sure the new cables are not Of 48 hours in advance. - All conduit entrances shall be grouted. trapped by the old cables or the concentric - Notify customers of all outages 48 hours in advance. Traffic Revisions neutrals. Work Drawings & Documents - Unless splices are called for, or otherwise noted or approved, conduit risers shall be hours. - Field design changes shall be approved by PSE Project Manager or Engineer. At Risers if the cable is - Install insulating caps on all unused primary bushings. - Mark all field changes, equipment ID numbers and Underground cable information in red on - Civil crew to install Conduit plug on each end until new cable to be installed. HANDHOLE Foreman's copy of work sketch. In Conduit -Remove Cable - Return one Foreman's copy of work sketch to Project Manager at completion of job. Direct buried or it cannot be pulled out, -Cut off & cap the cable at the top of the riser. - When permits are required, a copy shall be available On work site at all times. and the pole will remain. -Attach the old cable number to the cable stub. Safety POTELCO DESIGN AND INDEX - Refer to PSE standards 6275.3000 and 6275.6000 for system ground requirements. X.F.M.R. = TRANSFORMER QUALITY ASSURANCE - Refer to PSE standards 6275.9050 for personal protective grounding requirements. DIRECT BURIED Direct buried or it cannot be pulled out, -Remove the riser. - Refer to PSE standards 6275.9150 for vehicle grounding and barricading requirements. and the pole will be replaced -Cut off & cap the cable underground near the base of the - Proper line clearances shall be taken at the beginning, and released at the end, of each ❑ This design complies with PSE Design/Engineering Standards. pole. work day, or as otherwise instructed by the System Operator. Any/all variations have been pre-approved/documented by the Traffic /Pedestrian control notes The cable is direct buried or it cannot be -Cut off & cap the cable underground near the base of the appropriate PSE Representative. pulled out, and the pole will be removed. pole. - Utilize flagging and other vehicle traffic control as necessary and in conformance with local signature "e'g, PAGE 6 - CIVIL PLAN traffic regulations. �6 Print Name C!'t `i � �l > ih -The uniform code of traffic control shall be adhered to at all times.. neutral is connected with a hot tap, replace it. If the transformer bank has a 2 -bolt connector on -Provide signs, barricades, and traffic control in conformance with local permit regulations. the neutral bus, replace it. -Provide route for pedestrians when working on or near sidewalks. NOTE: If the pole is to be replaced, remove the abandoned riser and elbow, and stand off brackets (unless they support other conduits). -Maintain traffic flow as required by permitting agency. NOTE: If the riser is made of transite material, it shall be removed following procedures in standard 0100.5000, "Transite Pipe Removal and Disposal." NOTE: Completely rebuild terminations. EXCEPTION: DO NOT REPLACE CUTOUTS UNLESS THEY ARE THE OLDER "BOX TYPE" OR 50 AMP "TRIP LINK" TYPE CUTOUT. -Remove (not abandon) aboveground transite riser when it is encountered in the field. Belowground transite may be left in REPLACE J -BOXES IF REQUIRED. UTILIZE FEED-THRU T.U.T.S AND REMOVE place and backfilled. (Transite is a mixture of asbestos to moisture, low temperature, and corrosive agents). and cement. Itis nonmetallic, flame-retardant, and resistant J -BOXES IF POSSIBLE. REPLACE ALL TRANSFORMER JUMPERS WITH NEW 1/0 -For removal use an approved certified abatement contractor. Call the Environmental Services Department 24-hour pager JACKETED CABLE. (206-994-3186) to have a contractor dispatched. Procedure to Abandon Primary Cables: UNDERGROUND CONSTRUCTION 1. Call the Systems Operator to request a clearance. 2. Follow the directions to ensure the cable is de -energized, apply proper tags as specified in Standard Practice Additional notes to standards. 0201. 1011, "Switching and Clearances Handbook," and report back to the Systems Operator. -Erosion control must be placed before construction starts. Silt bags must be installed in 3. Obtain a clearance from the Systems Operator on the cable to be abandoned. A t t h b 4. Cut the ends of the cable. owns ream ca c CIO HO. 5. The cable number tag may be left on the abandoned cable. SURFACE IMPROVEMENT AND RESTORATION 1) FOLLOWING FINAL GRADING ACTIVITY, SOD SHALL BE PLACED ON EXPOSED SOIL TO PROVIDE PERMANENT AND IMMEDIATE EROSION PROTECTION. 2) TEMPORARY COLD MIX SHALL BE PLACED ON EXPOSED GRAVEL IN HARD SURFACE FOR IMMEDIATE EROSION PROTECTION AND HOT MIX ASPHALT WILL BE APPLIED AT FINAL RESTORATION TO PROVIDE PERMANENT EROSION PROTECTION. EXPOSED SOIL PROTECTION NOTES: AREAS WHERE THE GRADING ACTIVITIES, BORE PIT EXCAVATION OR UTILITY POT HOLING, WILL BE TEMPORARILY STABILIZED BY ONE OF THE FOLLOWING METHODS WHICH ARE BASED ON PERIOD OF EXPOSED SOILS ARE LEFT UNWORKED. -THERE WILL BE NO EXPOSED SOILS ON SITE DURING CONSTRUCTION. ALL SPOILS FROM EXCAVATION WILL BE VAC EXCAVATED INTO THE TRUCK. EROSION & SEDIMENT CONTROL REQUIREMENTS EROSION & SEDIMENT CONTROL SHALL BE PER PSE STANDARD PRACTICE 0150.3200 TECHNIQUES FOR TEMPORARY EROSION & SEDIMENT CONTROL & ANY ADDITIONAL LOCAL JURISDICTION REQUIREMENTS. (LOCAL JURISDICTIONS MAY HAVE ADDITIONAL REQUIREMENTS INCLUDING NOTES DETAILING WHERE EROSION OR SEDIMENT CONTROL STRUCTURES ARE TO BE INSTALLED, CROSS SECTION DETAILS OF THE TYPICAL EROSION STRUCTURES, & SPECIAL REQUIREMENTS FOR v'VORK IN SENSITIVE AREAS.) Filter fabric skirt Secured with grate. Catch Basin Grate Collected Sediment M -4 --overflow y A, Filter fabric walls for dewatering sediment I Catch Basin Insert MID 9995728 Gravel bags (MID 9995692) must be h gher at sides than center. 6" Min 44" Gravel Check Dam EROSION CONTROL NOT TO SCALE NOTE: The cable number shall not be reused. Existing Utilities: 6. Call the Systems Operator and release the clearance. Hand excavate (pothole) all marked utility crossings to verify exact location and depth at point 7. Remove all "Danger Do Not Operate" tags. of crossing. Protect underground utilities during excavation. Use hand excavation methods if 8. The System Operator will then close the Incident Number (1 -number). necessary to avoid damage to existing utilities. Fabricate and install adequate temporary Existing System: structures to support and protect underground utilities while exposed during construction. FUSED DISCONNECT: J Maintain existing electrical system in service until new system is complete, tested, and ready* for service. Maintain 6" minimum clearance at CrOSSIngS between existing utilities and new duct Disable existing system only to make cutovers and connections as directed br PSE System Operator. installations. Transition trench or tunnel profile gradually as required at crossings. Maintain SCOPE OF WORK 24" minimum separation between new trench or tunnel and parallel existing utilities or as The general scope of this project is to remediate primary 1/0 cables within the project area by the most economic required by the permit agency. means possible using replacement, or abandonment. Excavation The project involves replacing existing electrical cables in new conduit. - Trenching outside of the Right-of-way shall be of sufficient depth to provide a minimum of ❑ 36" of cover for primary conductors and 24" of cover for secondary conductors. Project type : Planned - Road crossings and all trenches within the Right-of-way shall be of sufficient depth to Project location: 1805 GRANT AVE S., RENTON, WA 98055 provide a minimum of 36" of cover for all conductors or as required by the permitting Agency. CRUSHED SURFACING - No rocks larger than 6" shall be included in backfill Number of Cables: 24 - Back fill in road crossings and within the Right-of-way shall be compacted to 95% density or Cable Footage Estimated : 5,035' as required by the permitting Agency. Cable Numbers Injected : 0 - Restore all excavated areas to original condition. Cable Numbers Repaired: 0 #2 Print Name Cable Numbers Abandoned: 0 Vaults & Hand holes Cable Numbers Replaced : 3430-32, 3983, 3975, 16079, 16080, ABD078, 3544-51, 10442, 4590-95 - Refer to PSE standard 6775.0040 "Vault and Hand hole Installation" Trench Footage Estimated : 3,757' - Vaults shall be placed level and 2" above final grade in landscaped areas and flush with There will be an advance notice provided by the contractor I r when laced in hard surface areas. n final grade de p 24-hour advance notice of no parking in work areas. Access will be maintained to all residences and their - A minimum 6�� bed of 5/8�� crushed rock shall be placed under all vaults. driveways. When work is occurring directly in front of driveways, the contractor will work with the residence to - All conduit entrances shall be grouted. manage access. Conductors & Conduit Traffic Revisions - Refer to PSE standard 6800.6000 "PVC Conduit Installation". Flagging crews will maintain one lane; flaggers will assist vehicles alternating through the roadway during work - Unless splices are called for, or otherwise noted or approved, conduit risers shall be hours. plumbed directly to road crossing conduits. For more information on the project - Install insulating caps on all unused primary bushings. 24-hour project information (888) 471-7339, (360) 825-5236 - Civil crew to install Conduit plug on each end until new cable to be installed. HANDHOLE - All "spare" conduits shall be capped at each end. SINGLE PHASE, ONE WIRE/CABLE - 7.2 KV Surface Restoration _____ TRENCH PATH Restore ground surface to original contour and original condition or better. Restore asphalt ABBREVIATIONS and concrete in accordance with requirements of local permitting agency. Cold patch or plate w w w— EXISTING WATER trench when necessary. Leave area in its original state or better at the end of construction. P.E. = POLYETHYLENE POTELCO DESIGN AND INDEX PHONE# X.F.M.R. = TRANSFORMER QUALITY ASSURANCE Tom. EXISTING TELEPHONE OVERHEAD APPARATUS N.T.S. = NOT TO SCALE —G—G—G—G— PAGE 1 - GENERAL NOTES When performing planned work on a pole with an existing transformer or device, the Service INCIDENT N/A Order N/A SCALE AS NOTED ❑ This design complies with PSE Design/Engineering Standards. PAGE 2 - SITE PLAN Provider will change out bolted connectors to pressed connectors". Use unit 1-3A to charge Any/all variations have been pre-approved/documented by the PAGE 3 - CONDUIT & CABLE PAGE 4 - ONE -LINE DIAGRAM time. appropriate PSE Representative. PAGE 5 - CIVIL PLAN If you are working on a pole with the pole ground connected with a hot tap, replace it. If the signature "e'g, PAGE 6 - CIVIL PLAN transformer has split bolts on the secondary neutral or services, replace them. If the primary �6 Print Name C!'t `i � �l > ih neutral is connected with a hot tap, replace it. If the transformer bank has a 2 -bolt connector on Date 1r the neutral bus, replace it. SURFACE IMPROVEMENT AND RESTORATION 1) FOLLOWING FINAL GRADING ACTIVITY, SOD SHALL BE PLACED ON EXPOSED SOIL TO PROVIDE PERMANENT AND IMMEDIATE EROSION PROTECTION. 2) TEMPORARY COLD MIX SHALL BE PLACED ON EXPOSED GRAVEL IN HARD SURFACE FOR IMMEDIATE EROSION PROTECTION AND HOT MIX ASPHALT WILL BE APPLIED AT FINAL RESTORATION TO PROVIDE PERMANENT EROSION PROTECTION. EXPOSED SOIL PROTECTION NOTES: AREAS WHERE THE GRADING ACTIVITIES, BORE PIT EXCAVATION OR UTILITY POT HOLING, WILL BE TEMPORARILY STABILIZED BY ONE OF THE FOLLOWING METHODS WHICH ARE BASED ON PERIOD OF EXPOSED SOILS ARE LEFT UNWORKED. -THERE WILL BE NO EXPOSED SOILS ON SITE DURING CONSTRUCTION. ALL SPOILS FROM EXCAVATION WILL BE VAC EXCAVATED INTO THE TRUCK. EROSION & SEDIMENT CONTROL REQUIREMENTS EROSION & SEDIMENT CONTROL SHALL BE PER PSE STANDARD PRACTICE 0150.3200 TECHNIQUES FOR TEMPORARY EROSION & SEDIMENT CONTROL & ANY ADDITIONAL LOCAL JURISDICTION REQUIREMENTS. (LOCAL JURISDICTIONS MAY HAVE ADDITIONAL REQUIREMENTS INCLUDING NOTES DETAILING WHERE EROSION OR SEDIMENT CONTROL STRUCTURES ARE TO BE INSTALLED, CROSS SECTION DETAILS OF THE TYPICAL EROSION STRUCTURES, & SPECIAL REQUIREMENTS FOR v'VORK IN SENSITIVE AREAS.) Filter fabric skirt Secured with grate. Catch Basin Grate Collected Sediment M -4 --overflow y A, Filter fabric walls for dewatering sediment I Catch Basin Insert MID 9995728 Gravel bags (MID 9995692) must be h gher at sides than center. 6" Min 44" Gravel Check Dam EROSION CONTROL NOT TO SCALE SS EXISTING SEWER Trench and backfill requirements for primary electric line extension trenches - A 12" layer of sand is required when excavated native material contains rocks up to 10" in diameter. - A 3" layer of sand is allowed when excavated native material contains rocks no larger than 8" in diameter. Excavated Dirt Pile ROADSIDE Final Grade 12" Typical 24 Mi — ►{ /i\//\/i\//\/i\ 36" Min Cover (ROW) 24"Min Cover (Pvt. Property) 48" Max TRENCH DETAIL NOT TO SCALE Backfill P��f No rocks over 10" diameter) j� 12" Min Sand Shading j\ 3" Sand Bedding —Primary Power in DB120 Conduit (ROW) Primary Power in SCH80 Conduit (Pvt. Property) Cables or Conduit - iG r - 3�'A_iM 25T I 100T 1 30 CLX X5005 ,}• ? X229 30�' �. S 5 ST p'.' x5002 1 •''3 • I `° I i� I �, oNo aoo j 4oT S 04641 co I I COCK N I N 04 CD �°' 7176 I zt a..... I N o x �� 1' X7175 G j� ` x� 1 X X �X 100T �• X 30: .. :3 �_� o �' o�1�t+25T� • ••• Q colw NZoIN V I -r7 •'.30 • co a' 7174 ^ I 1 B P X1459 U21S.:. ' ,.� a I X G ccooc .:3b. o� �• � 1 I �� 15T.•...0 �I t I Y@ X r- X X 11007 C r 'C 100TIOnX2297 •Y�100T ;��„ 40TS 7 STt................ A 0376 X5688 N X626 GRA A; ~off I I O .......A •• 1007 X8394 o� 2I N I 4 100T . 3 16 B : '-X i� � I i......... S UG 188_ _ _ IW x 3b �'—•}_ _yi PHIL LIP S •'s T 00385 s X1 0477 25TI I =I ARNOLD •00098 14 ,� 1 I PARK �••• c=�:.� = X4835 I � . 3 fb EAR -x'34••., GRA } c ccc - 405 15 r h ...... •.: 26 V y GRA 756•-330 30 �. , ; 00514 n; •i ;30 , .0 16 GRA .30 ll05 7Ms ��:• '� ':..;A 26 J22113 . B ;30 t ' 3s� •s•U2217 s 723 T 1 r, -c N H /C BC n� IC 1�oIC XLr) .'30: �•• :B S ' XN Lr)! I� �/ a� <S ..11 Z C, : :.,C•� ,35�...: T '04 Min 257 40T C �'� X11262 �•.• ''s„ ; •� 25A ... 1 1 C 25T 1 N X25 '- 146 S q1 X _ X��S� A'.�8•'••••' 30':•' A t m1 cn1 1 �� ; 16 S 65 a, ' .•C: B: :A • c� C 40T Q' s'T :: .... ' ....... 3�'•, 67 `11 1t` Qi 117 ST tti.' .•X4657 30 �.. CONO ::eo C ......:A L4J+fit , 1 / GRA •B �WN9 ; A. -'N..... :A ' BNa• WN�1 o C 25 �1 %... •: " ST t Q S A 19 Z1 _ �V�c T�-A 2Y_ 00.30 3�'' I..... E B,C .B •:,C •(�� 5T ..3 3 (/?¢ I• $ �- ......B (T ...- 16 �oX9 99 PU :.... • Y I c• A QJ Vic c � ^ e 70106 ?J rte¢ • .;•1 X1055 3 o : A Q I o 't ST • 21S cM y WNO X247 'B ,'c•"A •..30 C • ...;. :W 67 ZI BAB3� (/ 0902 X11 a67 r �I 257 .I 1...3 : • . .... ' •.� 889 :A ... 1 I.•• U869 s X11a6B x11164 :i i' . :3� .... 30: 657: TALBOT c:'Z :N� iH/LL 3 A' C:' V :A ELEO ; B GRA •';� �A •: 25 X7520 r' �o NELSON po 1042 A' S 965 30- 'ys 6TI� X B� X721 Q Vic Q: ti. S 30 loor 407 16 A 'ST.'A A- ''N :' SK746 3�.ST 257 W SE 1257 W65 ' S '�.• . X S 27 t B �uICO2358 .. X1781 063 21, '.� •' ,C m '•.D c. m� X 006 C — -IW Q I 100 . � . "�' _'�� B...• 'Z '•rte` :Q �so� SK 685' OVERHEAD CIRCUIT MAP: 2305E088 SCALE 611 = 1 MILE 12" MIN 48" MAX 36" MIN (ROW) 24" MIN (Pvt. Property) Primary Cable(S) - in Conduit 12" LEGEND FOREMAN (CHECK BOX WHEN COMPLETED) -� 12" MIN ELECTRONIC MARKER Q SOLID BLADE DISCONNECT J ❑ UNDERGROUND COMBINATION J-BOX/XFMR ' FUSED DISCONNECT: J COMBINATION J-BOX/PADMOUNT XFMR Material VERIFIED and CHANGES noted on Paperwork. 10T, 15T, 25T, 40T, 100T - INDICATES FUSE SIZE ❑ ASPHALT PATCH, 2" MIN —I (— NORMAL OPEN (N.O.) J ■ NEW UNDERGROUND COMBINATION J-BOX/XFMR ❑ Indicate correct FUSE SIZE an As -built & VERIFY proper PHASE. ❑ ❑ -j W b� WILL NOT PHASE (WN0) J A NEW COMBINATION J-BOX/PADMOUNT XFMR ❑ CRUSHED SURFACING I certify that the work performed meets PSE's standards and procedures TOTAL UNDERGROUND XFMR (T.U.T.) CD— OVERHEAD TO UNDERGROUND CABLE TERM. #1 Foreman's Signature #1 Print Name O� NEW OVERHEAD TO UNDERGROUND CABLE #2 Print Name PAD MOUNT XFMR OP MAP N/A TERMINATION 1■ NEW UNDERGROUND XFMR O FAULT INDICATOR 141 NEW PADMOUNT XFMR —+-- CABLE SPLICE PJ UNDERGROUND J-BOX FOREMAN #2 PRIMARY METERING OS UNDERGROUND SWITCH I IMQ CABLE TERMINATION BUS (J -BOX) PULL VAULT - — — — — THREE PHASE WIRE/CABLE - 12.5 KV Q HANDHOLE UTILITIES SINGLE PHASE, ONE WIRE/CABLE - 7.2 KV _____ TRENCH PATH ABBREVIATIONS — w— w w w— EXISTING WATER P.E. = POLYETHYLENE P —P —P EXISTING POWER PHONE# X.F.M.R. = TRANSFORMER Tom. EXISTING TELEPHONE N.T.S. = NOT TO SCALE —G—G—G—G— EXISTING GAS INCIDENT N/A Order N/A SCALE AS NOTED SD - SD - SD EXISTING STORM DRAIN SS EXISTING SEWER Trench and backfill requirements for primary electric line extension trenches - A 12" layer of sand is required when excavated native material contains rocks up to 10" in diameter. - A 3" layer of sand is allowed when excavated native material contains rocks no larger than 8" in diameter. Excavated Dirt Pile ROADSIDE Final Grade 12" Typical 24 Mi — ►{ /i\//\/i\//\/i\ 36" Min Cover (ROW) 24"Min Cover (Pvt. Property) 48" Max TRENCH DETAIL NOT TO SCALE Backfill P��f No rocks over 10" diameter) j� 12" Min Sand Shading j\ 3" Sand Bedding —Primary Power in DB120 Conduit (ROW) Primary Power in SCH80 Conduit (Pvt. Property) Cables or Conduit - iG r - 3�'A_iM 25T I 100T 1 30 CLX X5005 ,}• ? X229 30�' �. S 5 ST p'.' x5002 1 •''3 • I `° I i� I �, oNo aoo j 4oT S 04641 co I I COCK N I N 04 CD �°' 7176 I zt a..... I N o x �� 1' X7175 G j� ` x� 1 X X �X 100T �• X 30: .. :3 �_� o �' o�1�t+25T� • ••• Q colw NZoIN V I -r7 •'.30 • co a' 7174 ^ I 1 B P X1459 U21S.:. ' ,.� a I X G ccooc .:3b. o� �• � 1 I �� 15T.•...0 �I t I Y@ X r- X X 11007 C r 'C 100TIOnX2297 •Y�100T ;��„ 40TS 7 STt................ A 0376 X5688 N X626 GRA A; ~off I I O .......A •• 1007 X8394 o� 2I N I 4 100T . 3 16 B : '-X i� � I i......... S UG 188_ _ _ IW x 3b �'—•}_ _yi PHIL LIP S •'s T 00385 s X1 0477 25TI I =I ARNOLD •00098 14 ,� 1 I PARK �••• c=�:.� = X4835 I � . 3 fb EAR -x'34••., GRA } c ccc - 405 15 r h ...... •.: 26 V y GRA 756•-330 30 �. , ; 00514 n; •i ;30 , .0 16 GRA .30 ll05 7Ms ��:• '� ':..;A 26 J22113 . B ;30 t ' 3s� •s•U2217 s 723 T 1 r, -c N H /C BC n� IC 1�oIC XLr) .'30: �•• :B S ' XN Lr)! I� �/ a� <S ..11 Z C, : :.,C•� ,35�...: T '04 Min 257 40T C �'� X11262 �•.• ''s„ ; •� 25A ... 1 1 C 25T 1 N X25 '- 146 S q1 X _ X��S� A'.�8•'••••' 30':•' A t m1 cn1 1 �� ; 16 S 65 a, ' .•C: B: :A • c� C 40T Q' s'T :: .... ' ....... 3�'•, 67 `11 1t` Qi 117 ST tti.' .•X4657 30 �.. CONO ::eo C ......:A L4J+fit , 1 / GRA •B �WN9 ; A. -'N..... :A ' BNa• WN�1 o C 25 �1 %... •: " ST t Q S A 19 Z1 _ �V�c T�-A 2Y_ 00.30 3�'' I..... E B,C .B •:,C •(�� 5T ..3 3 (/?¢ I• $ �- ......B (T ...- 16 �oX9 99 PU :.... • Y I c• A QJ Vic c � ^ e 70106 ?J rte¢ • .;•1 X1055 3 o : A Q I o 't ST • 21S cM y WNO X247 'B ,'c•"A •..30 C • ...;. :W 67 ZI BAB3� (/ 0902 X11 a67 r �I 257 .I 1...3 : • . .... ' •.� 889 :A ... 1 I.•• U869 s X11a6B x11164 :i i' . :3� .... 30: 657: TALBOT c:'Z :N� iH/LL 3 A' C:' V :A ELEO ; B GRA •';� �A •: 25 X7520 r' �o NELSON po 1042 A' S 965 30- 'ys 6TI� X B� X721 Q Vic Q: ti. S 30 loor 407 16 A 'ST.'A A- ''N :' SK746 3�.ST 257 W SE 1257 W65 ' S '�.• . X S 27 t B �uICO2358 .. X1781 063 21, '.� •' ,C m '•.D c. m� X 006 C — -IW Q I 100 . � . "�' _'�� B...• 'Z '•rte` :Q �so� SK 685' OVERHEAD CIRCUIT MAP: 2305E088 SCALE 611 = 1 MILE 12" MIN 48" MAX 36" MIN (ROW) 24" MIN (Pvt. Property) Primary Cable(S) - in Conduit 12" #2 FOREMAN (CHECK BOX WHEN COMPLETED) -� 12" MIN PSE Equipment LOCKED/SECURED & Work Area left in CLEAN/SAFE Condition. MIN ❑ Grid, Cable, and Switch numbers INSTALLED & VERIFIED. ❑ EXISTING Field Changes RED -LINED on As -built. ❑ PAVEMENT / SIDEWIALK 1 Material VERIFIED and CHANGES noted on Paperwork. ❑ ❑ ASPHALT PATCH, 2" MIN ❑ ❑ Company ID#'s RECORDED in correct location on As -built. MATCH EXISTING ❑ Indicate correct FUSE SIZE an As -built & VERIFY proper PHASE. ❑ ❑ Correct QC Checklist(s) reviewed. VERTICAL SAW ❑ CUT LINE ❑ CRUSHED SURFACING I certify that the work performed meets PSE's standards and procedures MATERIAL COMPACT _ TO 95% MAX DENSITY. 12" Min Sand Shading 3" Sand Bedding EXCAVATION AND HARD RESTORATION DETAIL SCALE: NONE #1 #2 FOREMAN (CHECK BOX WHEN COMPLETED) ❑ ❑ PSE Equipment LOCKED/SECURED & Work Area left in CLEAN/SAFE Condition. ❑ ❑ Grid, Cable, and Switch numbers INSTALLED & VERIFIED. ❑ ❑ Field Changes RED -LINED on As -built. ❑ ❑ Material VERIFIED and CHANGES noted on Paperwork. ❑ ❑ Total PRIMARY Cable noted on As -built. ❑ ❑ Company ID#'s RECORDED in correct location on As -built. ❑ ❑ Indicate correct FUSE SIZE an As -built & VERIFY proper PHASE. ❑ ❑ Correct QC Checklist(s) reviewed. ❑ ❑ Deviations noted on the As -built and their reason. ❑ ❑ I certify that the work performed meets PSE's standards and procedures Gas Wk Ctr N/A POWER WK CTR QSEPRE and that all quality requirements are met. #1 Foreman's Signature #1 Print Name Date #2 Foreman's Signature #2 Print Name Date PROJECT PHASE NOTIF# ORDER# SUPERIOR FAILED SILICONE REMOVAL O&M MAINTENENCE EXPENSE 11260578 101101327 Approximate Trench Footage: 108097382 Abandon Cable Segments: 0 Replaced Cable Segments: CABLE REPLACEMENT REAL ESTATE/EASEMENT Trench Method: TRENCH Approximate Trench Footage: 4110' Abandon Cable Segments: 0 Replaced Cable Segments: 24 Approximate New 10/30 1/0 pri. Cable Footage: 4,390'/ 920' Approximate 2"/4" Poly/DB120 Conduit Footage: 3985'/ 855' Vaults: 2 "Locates Required" Yes No VICINITY MAP O C) N 4 Contact Information PSE: PLANNER 355 - 110TH AVE NE BELLEVUE, WA 98004 JOHN LERTKANTITHAM 425-462-3941 For contacts below dial 1 -888 -CALL PSE (225-5773) MAKE NO CHANGES TO THIS JOB WITHOUT PRIOR APPROVAL Notify Customers and Service Area 48 HRS Prior To Planned Outages CALL (800) 424-5555 2 BUSINESS DAYS BEFORE YOU DIG THIS SKETCH NOT TO BE RELIED UPON FOR EXACT LOCATION OF EXISTING FACILITIES Yes "Flagging Required" No REAL ESTATE/EASEMENT PERMIT CITY OF RENTON 3 FUNCTION CONTACT PHONE NO DATE 2 PROJECT MGR C. YLENNI 253-720-9700 10/28/16 1 ENGR - POWER A. BERRY 253-326-1524 10/21/16 REV# DATE BY DESCRIPTION ENGR - GAS N/A N/A N/A COUNTY KING Emer Sect N/A Gas Wk Ctr N/A POWER WK CTR QSEPRE DRAWN BY S. ANDREWS 253-234-6114 10/21/16 CHECKED BY d1 ®> 1/4 SEC SW -20-23-5 OP MAP N/A PLAT MAP N/A APPROVED BY j> FOREMAN #1 U -MAP NO (POWER) 2305EO79 OH CKT MAP 2305EO88 JUGCKTIMAP 2305E079 ICIRCUITNO GRA -25 FOREMAN #2 IMAPPING JOINT FACILITIES ARRANGEMENTS UTILITIES CONTACT PHONE# PUGET SOUNDGas ENERGY DESIGNED BY Potelco, Inc. GRA -25 S ETHIER RD 2017 CRP CABLE REMEDIATION PROGRAM 1805 GRANT AVE S., RENTON, WA 98055 INCIDENT N/A Order N/A SCALE AS NOTED P MOP Elect Order 101101327 PAGE 1/6 TYP 151 :K- jL7) PERMIT CITY OF RENTON 3 FUNCTION CONTACT PHONE NO DATE 2 PROJECT MGR C. YLENNI 253-720-9700 10/28/16 1 ENGR - POWER A. BERRY 253-326-1524 10/21/16 REV# DATE BY DESCRIPTION ENGR - GAS N/A N/A NN COUNTY KING Emer Sect N/A Gas Wk Ctr N/A POWER WK CTR QSEPRE DRAWN BY S. ANDREWS \� 10/21/16 CHECKED BY y>/ Secondary Gable \ 10 APPROVED BY Secondary Cable �-- DB 120 PVG OH CKT MAP 2305EO88 UG CKT MAP 2305EO79 CIRCUIT INO GRA -25 FOREMAN #2 2" DE 120 PVC - Primary C.N. Cable Secondary Cable J Figure 2 Typical minipad transformer installation with conduit (loop construction) L MINIPAD TRANSPOMER INSTALLATR Not to scale 6045.1010 V/ CONDUIT SITE PLAN SCALE: 1:500 iA SITE PLAN CONT. SCALE: 1:50 0 0 w N 4 REAL ESTATE/EASEMENT PERMIT CITY OF RENTON 3 FUNCTION CONTACT PHONE NO DATE 2 PROJECT MGR C. YLENNI 253-720-9700 10/28/16 1 ENGR - POWER A. BERRY 253-326-1524 10/21/16 REV# DATE BY DESCRIPTION ENGR - GAS N/A N/A N/A COUNTY KING Emer Sect N/A Gas Wk Ctr N/A POWER WK CTR QSEPRE DRAWN BY S. ANDREWS 253-234-6114 10/21/16 CHECKED BY y>/ 1/4 SEC SW -20-23-5 OP MAP N/A PLAT MAP N/A APPROVED BY FOREMAN #1 U -MAP NO (POWER) 2305EO79 OH CKT MAP 2305EO88 UG CKT MAP 2305EO79 CIRCUIT INO GRA -25 FOREMAN #2 MAPPING JOINT FACILITIES ARRANGEMENTS UTILITIES CONTACT PHONE# PUGET SOUND ENERGY DESIGNED BY Potelco, Inc. GRA -25 S ETHER RD 2017 CRP CABLE REMEDIATION PROGRAM 1805 GRANT AVE S., RENTON, WA 98055 INCIDENT N/A MAOP N/A Gas Order N/A Elect Order 101101327 SCALE AS NOTED PAGE 2/6 EXISTING UNDERGROUND MAP #: 2305EO79 SCALE: 1:100 1,300 - 1,365 lbs 6" 0 O D 0 3,600 Ibs_�,, 3'-6" �J 4'-8" 4,-8. TOP VIEW 2" 7 00 00Crushed „ 10011001 Rock 414 SIDE VIEW I Excavation - 10-1 /3 cubic yards VAULT & EXCAVATION DETAIL Not to scale 6055.1010 TOP VIEW Cables should enter the vault so that all of the cables will lay in the same direction. J- BOX CABLE ENTRY DETAIL @ J02A, J03A NOT TO SCALE ABANDONED / REMOVE / REPLACED CABLE SCHEDULE CABLE NO. SAP EQUIP LOCATIONS FROM TO CABLE (LF) EST EXISTING CABLE EXISTING CABLE CABLE MFG. NAME MFG. DATE REPLACED? 4590 i UNK P01 Vol 230 YES 4591 I UNK Vol V02 265 YES 4592 ( UNK V02 V03 181 YES 4593 UNK V03 VO4 78 YES 4594 € UNK VO4 V05 164 YES 4595 UNK V05 V06 153 YES 3551 10591213 V06 V07 483 YES 10442 UNK V07 V08 165 YES 3550 UNK V08 V09 91 YES 3549 UNK V09 V10 91 YES 3548 UNK V10 V11 133 YES 3547 UNK V11 V12 134 YES 3546 UNK V12 V13 101 YES 3545 UNK V13 V14 142 YES 3544 UNK V14 V15 ".. 86 YES ABD078 UNK V15 JO{ 349 YES 3975 UNK J02 V16 1470 YES 3983 UNK J01 J02 ( 416 YES 16080 UNK J01 V1:6 44 YES 16079 UNK J01 V' 6 112 YES 3430 UNK J01 P01 377 YES 3431 UNK J01 P31 377 YES 3432 10589449 J01 P01 377 YES TOTAL VAULT & EQUIPMENT TABLE 3,420' CONSTRUCTION NOTES P01: -CUT OFF & CAP OLD CABLES AT TOP OF RISER -ATTACH OLD CABLE # TO CABLE STUB -REMOVE OLD C/O & TERM -INST 10 LB C/O TERM F:40T STD 6043.1000 (TSU1C1) -INST 1-2" RISER ON STAND-OFF BRKTS STD 6042.1000 (RIS2CSS) -INST SW#X4657 P02: -CUT OFF & CAP OLD CABLES AT TOP OF RISER -ATTACH OLD CABLE # TO CABLE STUB -REMOVE OLD C/O & TERM -INST 30 LI C/O TERM F: 100T STD 6043.1000 (TSU31_IF) -INST 1-4" RISER ON STAND-OFF BRKTS STD 6042.1000 (RIS2CSS) -INST SW# T78428 P03: -REPLACE FUSE WITH 100T FUSE Standoff Bracket 15" Min Length Conduit Clamp 5" Min Climbing Space uit Field Face Road Face Quadrant Quadrant Climbing Space Direction of Vehicular Traffic TOP VIEW CONDUIT RISER REPLACEMENT DETAIL @ P01 & P02 NOT TO SCALE Crew to provide all property owner's that are impacted by project prior notice and make an effort to work with property owner's to maintain their access to their property, as well as, reduce the impact of our work on their use of their property." FOREMAN NOTE: Call (800) 424-5555 Utility Notification Center 24/7 before beginning any excavation prevents damage to underground facilities, service interruptions & bodily injury. CIVIL CREW FOREMAN NOTE: Maintain on site, in good condition, a complete file of all work drawings. These drawings shall be available at all times to a Puget Sound Energy representative. Corrections and changes made during the job shall be recorded continuously on these drawings. Mark all underground utilities encountered during construction on these drawings. Furnish Puget Sound Energy a complete set of as -built prints (foreman's copies) at the end of the job. WIRE CREW FOREMAN NOTE: ALL FAULT INDICATORS WILL BE MAINTAINED IN THEIR CURRENT LOCATION ON 1/0 CABLES AFTER NEIN CABLE IS INSTALLED UNLESS OTHERWISE SPECIFIED. PLEASE RED -MARK ALL. FAULT INDICATORS ON "CABLE DIAGRAM" FOR MAPPING. O O N 4 PRIMARY REAL ESTATE/EASEMENT PERMIT CITY OF RENTON SITE GRID VAULT SIZE & TYPE & S= I BUSHINGS TRANSFORMER ID NUMBERS REMARKS NUMBER COVER } EQUIPMENT IN VAULT (COMPANY ID) 2 LB DC PROJECT MGR C. YLENNI 253-720-9700 317295 EXISTING J -BOX BELS 'GRADE REPLACE ELBOWS & CONDUCTORS J01 166127 JUNCTION Box W/ 3-1, EO J -B IS 8 EXISTING ING REV# DATE BY WIRE CREW TO INSTALL GRID NUMBERS ENGR - GAS J -BOX EEtGRADE I N/A N/A COUNTY KING J02 317312 EXISTING W/ 3-4 Eos 2 DRAWN BY S. ANDREWS REPLACE ELBOWS & CONDUCTORS 166141 CHECKED BY JUNCTION Box EX4STING t:; - OP MAP N/A WIRE CREW TO INSTALL GRID NUMBERS NEW 317240 HH 4'8"x4'8"X3'6" J -BOX BELOW GRADE I' FOREMAN #1 INSTALL NEW 504 J -BOX J02A w/ 3' DOOR wt 1-4 POs. J -BUS I 4 MAT ID:: 7663900 MATID: 7625900 - CIRCUITNO GRA -25 WIRE CREW TO INSTALL GRID NUMBERS 166230 NEW 317282 HH 4'8"X4'8"X3'6" J -BOX BELOW GRADE INSTALL NEW 504 J -BOX J03A W/ T sQ DOOR WI 2-4 POS. J -BUS 7 MAT ID: 7663900 MATID: 7625900 1 WIRE CREW TO INSTALL GRID NUMBERS 166152 CONTACT REMOVE EXISTING VAULT LID AND 317201 1 OOkVA TUT XFMR PHONE# TUT XFMR & REPLACE WITH NEW VAULT Vol EXISTING VAULT 120/240v 2 - PUGET SOUND ENERGY DESIGNED BY Potelco, Inc. LID AND MINIPAD XFMER WITH NEW 166227 INCIDENT MAOP N/A N/A Gas Order Elect Order N/A 101101327 SCALE PAGE AS NOTED 3/6 ExlsrwG ELBOWS & CONDUCTORS WIRE CREW TO INSTALL GRID NUMBERS REMOVE EXISTING VAULT LID AND 317186 I u7.5kVA TUT XFMR TUT XFMR & REPLACE WITH NEW VAULT V02166232 EXISTING 120/240V 1 - LID AND MINIPAD XFMER WITH NEW VAULT EXISTING ELBOWS & CONDUCTORS WIRE CREW TO INSTALL GRID NUMBERS REMOVE EXISTING VAULT LID AND 317195 v 5^-A'A TUT XFMR TUT XFMR & REPLACE WITH NEW VAULT V03 EXISTING E/2aov 2 - LID AND MINIPAD XFMER WITH NEW 166222 VAULT EXISTING ELBOWS & CONDUCTORS WIRE CREW TO INSTALL GRID NUMBERS REMOVE EXISTING VAULT LID AND 317202 L'�,VATUTXFMR TUT XFMR & REPLACE WITH NEW VAULT VO4 EXISTING 120/240v 2 - LID AND MINIPAD XFMER WITH NEW 166221 VAULT EXISTING ELBOWS & CONDUCTORS WIRE CREW TO INSTALL GRID NUMBERS REMOVE EXISTING VAULT LID AND 317210 37.5kVA T ?XFMR TUT XFMR & REPLACE WITH NEW VAULT V05 EXISTING 12 G4 ' 2 - LID AND MINIPAD XFMER WITH NEW 166229 VAULT EXISTING } ELBOWS & CONDUCTORS WIRE CREW TO INSTALL GRID NUMBERS REMOVE EXISTING VAULT LID AND 31 50kVA TUT '1F!,,R 317221 TUT XFMR & REPLACE WITH NEW VAULT V06 EXISTING EXISTING 2 - LID AND MINIPAD XFMER WITH NEW 221 EX€STI vG VAULT ELBOWS & CONDUCTORS WIRE CREW TO INSTALL GRID NUMBERS REMOVE EXISTING VAULT LID AND 317230 A T` T XFMR TUT XFMR & REPLACE WITH NEW VAULT V07 EXISTING 24_, 2411v 1 - LID AND MINIPAD XFMER WITH NEW 166191 VAULT EXISTING i ELBOWS & CONDUCTORS WIRE CREW TO INSTALL GRID NUMBERS REMOVE EXISTING VAULT LID AND -I OOkVA T4 T X7MR 317238 TUT XFMR & REPLACE WITH NEW VAULT V08 EXISTING EXISTING 2�` E ,, 2 - LID AND MINIPAD XFMER WITH NEW 166188 i' T EXISTING ELBOWS & CONDUCTORS WIRE CREW TO INSTALL GRID NUMBERS 317245 EXISTING 50k"A TUT XFMR REPLACE ELBOWS & CONDUCTORS V09 166190 VAULT 120:2 2 EXISTING - WIRE CREW TO INSTALL GRID NUMBERS 317247 EXISTING 75kVA TUT XFMR REPLACE ELBOWS & CONDUCTORS V10 166181 - VAULT 2 `` 1 ING EXISTING - WIRE CREW TO INSTALL GRID NUMBERS REMOVE EXISTING VAULT LID AND 1 OOkVA TUT XFMR 317254 TUT XFMR & REPLACE WITH NEW VAULT V11 EXISTING 1201240V 1 - LID AND MINIPAD XFMER WITH NEW 166174 FAULT EXISTING ELBOWS & CONDUCTORS WIRE CREW TO INSTALL GRID NUMBERS 75kVA PM XFMR 317251 EXISTING REPLACE ELBOWS & CONDUCTORS V12166166 VAULT 120/240v 1 EXISTING - WIRE CREW TO INSTALL GRID NUMBERS 317264i EXISTING 75kVA PM XFMR REPLACE ELBOWS & CONDUCTORS V13166159VAULT 120/240v 2 EXISTING - WIRE CREW TO INSTALL GRID NUMBERS 75kVA PM XFMR 317273 EXISTING REPLACE ELBOWS & CONDUCTORS V14 1 _ 166154 VAULT EXISTING WIRE CREW TO INSTALL GRID NUMBERS REMOVE EXISTING VAULT LID AND 317278 75kVA TUT XFMR TUT XFMR & REPLACE WITH NEW VAULT V15 EXISTING 120/240v 2 - LID AND MINIPAD XFMER WITH NEW 166154 VAULT EXISTING ELBOWS & CONDUCTORS WIRE CREW TO INSTALL GRID NUMBERS REMOVE EXISTING VAULT LID AND 25kVA TUT XFMR 317292 TUT XFMR & REPLACE WITH NEW VAULT V16 EXISTING 12o/2aov 1 - LID AND MINIPAD XFMER WITH NEW 166119 VAULT EXISTING i ELBOWS & CONDUCTORS WIRE CREW TO INSTALL GRID NUMBERS TOTALS:1 46 1 CONSTRUCTION NOTES P01: -CUT OFF & CAP OLD CABLES AT TOP OF RISER -ATTACH OLD CABLE # TO CABLE STUB -REMOVE OLD C/O & TERM -INST 10 LB C/O TERM F:40T STD 6043.1000 (TSU1C1) -INST 1-2" RISER ON STAND-OFF BRKTS STD 6042.1000 (RIS2CSS) -INST SW#X4657 P02: -CUT OFF & CAP OLD CABLES AT TOP OF RISER -ATTACH OLD CABLE # TO CABLE STUB -REMOVE OLD C/O & TERM -INST 30 LI C/O TERM F: 100T STD 6043.1000 (TSU31_IF) -INST 1-4" RISER ON STAND-OFF BRKTS STD 6042.1000 (RIS2CSS) -INST SW# T78428 P03: -REPLACE FUSE WITH 100T FUSE Standoff Bracket 15" Min Length Conduit Clamp 5" Min Climbing Space uit Field Face Road Face Quadrant Quadrant Climbing Space Direction of Vehicular Traffic TOP VIEW CONDUIT RISER REPLACEMENT DETAIL @ P01 & P02 NOT TO SCALE Crew to provide all property owner's that are impacted by project prior notice and make an effort to work with property owner's to maintain their access to their property, as well as, reduce the impact of our work on their use of their property." FOREMAN NOTE: Call (800) 424-5555 Utility Notification Center 24/7 before beginning any excavation prevents damage to underground facilities, service interruptions & bodily injury. CIVIL CREW FOREMAN NOTE: Maintain on site, in good condition, a complete file of all work drawings. These drawings shall be available at all times to a Puget Sound Energy representative. Corrections and changes made during the job shall be recorded continuously on these drawings. Mark all underground utilities encountered during construction on these drawings. Furnish Puget Sound Energy a complete set of as -built prints (foreman's copies) at the end of the job. WIRE CREW FOREMAN NOTE: ALL FAULT INDICATORS WILL BE MAINTAINED IN THEIR CURRENT LOCATION ON 1/0 CABLES AFTER NEIN CABLE IS INSTALLED UNLESS OTHERWISE SPECIFIED. PLEASE RED -MARK ALL. FAULT INDICATORS ON "CABLE DIAGRAM" FOR MAPPING. O O N 4 REAL ESTATE/EASEMENT PERMIT CITY OF RENTON 3 FUNCTION CONTACT PHONE NO DATE 2 PROJECT MGR C. YLENNI 253-720-9700 10/28/16 1 ENGR - POWER A. BERRY 253-326-1524 10/21/16 REV# DATE BY DESCRIPTION ENGR - GAS N/A N/A N/A COUNTY KING Emer Sect N/A Gas, Wk Ctr N/A POWER WK CTR QSEPRE DRAWN BY S. ANDREWS 253-234-6114 10/21/16 CHECKED BY 1/4 SEC SW -20-23-5 OP MAP N/A PLAT MAP N/A APPROVED BY FOREMAN #1 U -MAP NO (POWER) 2305EO79 OH CKT MAP 2305EO882305EO79 FUGCKTMAP CIRCUITNO GRA -25 FOREMAN#2 MAPPING JOINT FACILITIES ARRANGEMENTS UTILITIES CONTACT PHONE# PUGET SOUND ENERGY DESIGNED BY Potelco, Inc. GRA -25 S ETHIER RD 2017 CRP CABLE REMEDIATION PROGRAM 1805 GRANT AVE S., RENTON, WA 98055 INCIDENT MAOP N/A N/A Gas Order Elect Order N/A 101101327 SCALE PAGE AS NOTED 3/6 PRIMA NOT TO AEX095 - CO (EXISTING) 23161 - CO (EXISTING) LOCATION REAL ESTATE/EASEMENT PERMIT CITY OF RENTON CONDUIT FUNCTION CONTACT PHONE NO DATE PRIMARY CABLE REMARKS FROM TO SIZE (in) QTY DESIGN ACTUAL LENGTH LENGTH (ft) (ft) TYPE DB120 POLY SCH 80 90 BENDS 45 22 11 PULL (Ibs) PULL REV (lbs) CABLE SIZE DESIGN ACTUAL LENGTH LENGTH (ft) (ft) CABLE NUMBERS PLEASE RECORD FOREMAN - COMPLETE A B C MANUFACTURER COMPOUND YEAR P02 J01 4 1 560 - - X 2 - 1 - 985.3 996.6 1/0 AL JKT 605 EHN900 EHN901 EHN902 J01 J02 4 1 1 295 - - X 2 - - - 1465.6 469.0 1/0 AL JKT 315 - EHN903 EHN904 J01 V16 2 1 20 - - X - - - - 32.8 32.8 1/0 AL JKT 40 - EHN905 - J01 J03A 2 1 385 - - X 3 - - - 178.5 187.4 1/0 AL JKT 405 EHN906 - - J03A J03A - - - I - - X - - - - - - 1/0 AL JKT 20 EHN907 - - J03A V15 2 1 85 - - X 2 - I - - 76.9 1 82.0 1/0 AL JKT 105 EHN908 - - V15 V14 2 1 60 - - X - - - - 38.3 38.3 1/0 AL JKT 80 EHN909 - - J03A V13 2 1 285 - - X 3 - - - 158.0 160.4 1/0 AL JKT 305 EHN910 - - V13 V12 2 1 45 - - X - - - 36.2 36.2 1/0 AL JKT 65 EHN911 - - J03A V11 2 1 525 - - X 3 1 - - 260.1 237.8 1/0 AL JKT 545 EHN912 - - J03A J02A 2 1 770 - - X 2 - - - 214.1 217.1 1/0 AL JKT 790 EHN913 - - J02A V09 2 1 405 - - X 3 - 2 - 213.6 224.3 1/0 AL JKT 425 EHN914 - - V09 V10 2 1 80 - - X 2 - - - 78.1 78.1 1/0 AL JKT 100 EHN915 - - V10 V08 2 1 45 - - X 2 - - - 36.2 36.2 1/0 AL JKT 65 EHN916 - - V08 V07 2 1 200 - X - - 1 - - 65.1 67.9 1/0 AL JKT 220 EHN940 J02A P01 2 1 335 - - X 1 1 - - 107.5 119.2 1/0 AL JKT 380 EHN917 - - J02A V06 2 1 285 - - X 2 - - - 123.4 146.6 1/0 AL JKT 305 EHN918 - - V06 V05 2 1 150 - - X 1 2 - - 94.2 90.2 1/0 AL JKT 170 EHN919 - - V05 V01 2 1 1 125 - - X 1 2 - - 85.3 89.3 1/0 AL JKT 145 EHN920 - - V01 VO4 2 1 85 - - X 2 - - - 80.0 78.5 1/0 AL JKT 105 EHN921 - - VO4 V03 2 1 105 - - X 1 2 - - 84.0 82.5 1 1/0 AL JKT 125 EHN922 - - V03 V02 2 1 195 - - X 2 - - - 101.11 101.1 1 1/0 AL JKT 215 EHN923 - - TOTAL 4" 855' - - - 4 - 1 - TOTAL 30 920' TOTAL 2" 4,185' - - - 30 9 2 - TOTAL 1O 4,610' QTS OF GLUE 1 8.8 I GALS OF LUBE I 18.9 CIVIL CREW NOTE: ALL 2" - 90° BENDS MIN 48" RADIUS SCH-80 PVC ALL 2" - 450 BENDS SCH-80 PVC ALL 4" - 900 BENDS MIN 60" RADIUS SCH-80 PVC ALL 4" - 450 BENDS SCH-80 PVC - ALL CONDUITS SHALL BE CAPPED AT EACH END UNTIL CABLE IS INTALLED X D Z D m O O w no REAL ESTATE/EASEMENT PERMIT CITY OF RENTON 3 FUNCTION CONTACT PHONE NO DATE 2 PROJECT MGR C. YLENNI 253-720-9700 10/28/16 1 ENGR-POWER A. BERRY 253-326-1524 10/21/16 REV# DATE BY DESCRIPTION ENGR - GAS N/A N/A N/A COUNTY KING Emer Sect Gas Wk Ctr N/A N/A POWER WK CTR QSEPRE DRAWN BY S. ANDREWS 253-234-6114 10/21/16 CHECKED BYp / 1/4 SEC SW -20-23-5 OP MAP N/A PLAT MAP N/A APPROVED BY FOREMAN #1 U -MAP NO (POWER) 2305EO79 OH CKT MAP 2305EO88 JUGGKTMAP 2305EO79 ICIRCUITNO GRA -25 FOREMAN #2 MAPPING JOINT FACILITIES ARRANGEMENTS UTILITIES CONTACT PHONE# PUGET SOUND ENERGY DESIGNED BY Potelco, Inc. GRA -25 S ETHIER RD 2017 CRP CABLE REMEDIATION PROGRAM 1805 GRANT AVE S., RENTON, WA 98055 INCIDENT ENT MN OP Gas Order Elect Order N/A 101101327 SCALE PAGE AS NOTED 416 � . = ' `� \ ,'' / � y+ • '� � . 1 1 030625 �-..._--- 1 �317305-16616 .� 'i. ' / `;75kVA 120/2 v 7 1620 UNIT {10 6948} Oe 1201 317302-16 6 ~f / 75 kVA 120/240v Jl % N 1104 ® UNC �� •� ,- ; _ / �J `, 3 7305®156 5 ' 1203 , 7 kVA 1201 \ ®� , a . / —5kV '117297- .------------------------------- ---- 8 Q1, 17296 1661 l 7kVA 120/ 40v 1204 5 v 3172 Qa L � � s Ps � 1200 50 kV 0 72 - T� 165 1 \ \ s�. 17237-166169 SS / d Q�� \ Ps • 75 120/2 v zi N S �` 9758 X14 r I DO3 �' � � 317279-166166� A SS P02 s, P#2023059014 1101 /.. W 3:; 133 :......... .......... V 14 1203 / QS z \ Q \� r / d •� / PS 0— 'N% W _ a 1726 16617Co 1205 1201 Ps Z_ N V 1 3 1303 _ 317265-166092SL Q 1 ® O LJ Wool CIVIL PLAN REAL ESTATE/EASEMENT PERMIT SCALE: 1:30 CITY OF RENTON 3 FUNCTION CONTACT PHONE NO DATE 2 PROJECT MGR C. YLENNI 253-720-9700 10/28/16 1 ENGR - POWER A. BERRY 253-326-1524 10/21/16 REV# DATE BY DESCRIPTION ENGR - GAS N/A N/A N/A COUNTY Emer Sect Gas Wk Ctr POWER WK CTR DRAWN BY S. ANDREWS 253-234-6114 10/21/16 KING N/A N/A QSEPRE CHECKED BY 1/4 SEC OP MAP PLAT MAP APPROVED BY C/llfjrZS �% SW-20-23-5 N/A N/A FOREMAN #1 U-MAP NO (POWER) OH CKT MAP UG CKT MAPCIRCUIT NO FOREMAN #2 2305EO79 2305EO88 2305EO79 GRA-25 MAPPING JOINT FACILITIES ARRANGEMENTS UTILITIES CONTACT PHONES# PUGET INCIDENT MAOP GRA-25 S ETHER RD 2017 CRP N/A N/A SOUND CABLE REMEDIATION PROGRAM Gas Order Elect Order 101101327 ENERGY 1805 GRANT AVE S., RENTON, WA 98055 SCALELE PAGE DESIGNED BY Potelco, Inc. AS NOTED 5/6 u u C 0 u Li 0 L C F e. pi SCALE: 1:30 CIVIL PLAN (CONTINUED) SCALE: 1:30 0 0 w N 4 REAL ESTATE/EASEMENT PERMIT CITY OF RENTON 3 FUNCTION CONTACT PHONE NO DATE 2 PROJECT MGR C. YLENNI 253-720-9700 10/28/16 1 ENGR - POWER A. BERRY 253-326-1524 10/21/16 REV# DATE BY DESCRIPTION ENGR - GAS N/A N/A N/A COUNTY KING Emer Sect Gas Wk Ctr N/A N/A POWER WK CTR QSEPRE DRAWN BY S. ANDREWS 253-234-6114 10/21/16 CHECKED BY 1/4 SEC SW -20-23-5 OP MAP N/A PLAT MAP N/A APPROVED BY FOREMAN #1 U -MAP NO (POWER) 2305EO79 OH CKT MAP 2305EO88 JUG CKT MAP 2305EO79 CIRCUIT NO I GRA -25 FOREMAN #2 MAPPING JOINT FACILITIES ARRANGEMENTS UTILITIES CONTACT PHONE# UGET SGas �-�/ ENERGY DESIGNED BY Potelco, Inc. GRA -25 S ETHER RD 2017 CRP CABLE REMEDIATION PROGRAM 1805 GRANT AVE S., RENTON, WA 98055 INCIDENT N/A Order N/A SCALE AS NOTED MAOP N/A Elect Order 101101327 PAGE 6/6