Loading...
HomeMy WebLinkAboutP_Utility Plan Renton Project_571014492_V1GENERAL NOTES - ALL WORK IS TO BE COMPLETED PER PSE STANDARDS & PRACTICES. COPIES OF ALL PSE STANDARDS ARE AVAILABLE UPON REQUEST. - WORK SITES SHALL BE KEPT CLEAR OF DEBRIS AND ALL CONSTRUCTION MATERIALS, EQUIPMENT AND PACKING SHALL BE REMOVED DAILY. - RETURN ALL UNUSED AND REMOVED POLES, TRANSFORMERS AND HARDWARE TO PSE STOREROOM. ALL COPPER SHALL BE COILED AND RETURNED THE DAY IT IS REMOVED FROM THE POLES. REMOVE ALL UNUSED PINS AND INSULATORS. RETURN ALL STREET LIGHTS, AREA LIGHTS AND FLOODLIGHTS TO PSE. PRECONSTRUCTION - NOTIFY APPROPRIATE CITY, COUNTY OR DOT AUTHORITIES 48 TO 72 HOURS, OR AS REQUIRED BY PERMITTING AGENCY, IN ADVANCE OF STARTING WORK IN RIGHT-OF-WAY INVOLVING A PERMIT. - ALL DISTRIBUTION SYSTEM SWITCHING SHALL BE APPROVED BY SYSTEM OPERATIONS A MINIMUM OF 48 HOURS IN ADVANCE. ALL TRANSMISSION SYSTEM SWITCHING SHALL BE SCHEDULED WITH THE LOAD OFFICE A MINIMUM OF 5 DAYS IN ADVANCE. - NOTIFY CUSTOMERS OF ALL OUTAGES 48 HOURS IN ADVANCE. - EROSION CONTROL PROCEDURES SHALL BE USED IN ACCORDANCE WITH THE MINIMAL REQUIREMENTS SPECIFIED IN PSE STD 0150.3200 "TECHNIQUES FOR TEMPORARY EROSION AND SEDIMENT CONTROL". - WORK SHALL NOT BEGIN UNTIL ALL EASEMENTS AND STREET USE PERMITS HAVE BEEN SECURED. FINAL NOTIFICATION TO PROCEED SHALL BE GIVEN BY THE PROJECT MANAGER. WORK DRAWINGS AND DOCUMENTS - MARK ALL FIELD CHANGES, EQUIPMENT ID NUMBERS AND UNDERGROUND CABLE INFORMATION IN RED ON FOREMAN'S COPY OF WORKSKETCH. - RETURN ONE FOREMAN'S COPY OF WORKSKETCH TO PROJECT MANAGER AT COMPLETION OF JOB. - WHEN PERMITS ARE REQUIRED, A COPY SHALL BE AVAILABLE ON WORK SITE AT ALL TIMES. SAFETY - REFER TO PSE STANDARDS 6275.xxxx FOR SYSTEM GROUND REQUIREMENTS. - PROPER LINE CLEARANCES SHALL BE TAKEN AT THE BEGINNING, AND RELEASED AT THE END, OF EACH WORK DAY, OR AS OTHERWISE INSTRUCTED BY THE SYSTEM OPERATOR. - PROVIDE SIGNS, BARRICADES, AND TRAFFIC CONTROL IN CONFORMANCE WITH PERMIT REGULATIONS AND LOCAL TRAFFIC REGULATIONS. 0 i SANTA FE Lij � W 7TH ST --- ----- --------- SHE T 2 LLJQ GRA TALBOT - METRO RENTON 115kV J ' ST 19 W_ m O J 167 = O m O UGET O� S 21 ST N ST `SO - ------------------- --------- - -------- s ----------------- VICINITY MAP ENGINEER: JOHN SEALY PROJECT NOTES PHONE: 425-516-4929 PROJECT SCOPE - TEMPORARY GUYING TO PROVIDE CLEARANCE FOR NEW CONSTRUCTION CONSTRUCTION NOTES - ALL CONSTRUCTION SHALL BE IN ACCORDANCE WITH THE STANDARD NOTES FOR WOOD POLES CONSTRUCTION, DWG D-12842 SH 1 OF 1. - THE ENGINEER SHALL BE CONTACTED WITH REGARDS TO ALL TECHNICAL INFORMATION. THE ENGINEER SHALL HAVE SOLE AUTHORITY TO APPROVE ANY AND ALL CONSTRUCTION CHANGES. - DESIGN DETAILS AND NOTES SHALL SUPPLEMENT THE STANDARDS REFERENCED IN THIS DRAWING. CALL (800)424-5555 2 BUSINESS DAYS BEFORE YOU DIG THIS SKETCH NOT TO BE RELIED UPON FOR EXACT LOCATION OF FACILITIES "Locates Required" Yes ❑ No❑ "Outages Required" Yes ❑ No❑ "Flagging Required" Yes ❑ No❑ TRANSMISSION SYMBOL LEGEND ABBREVIATION KEY O EXISTING POLE ANCH ANCHOR • NEW POLE BRKT BRACKET X REMOVED POLE CHG CHANGE CL CLASS ❑ EXISTING LAMINATE POLE C/N COMMON NEUTRAL NEW LAMINATE POLE CU COPPER Q EXISTING STEEL POLE C/0 CUTOUT NEW STEEL POLE DE DEADEND DISC DISCONNECT EXISTING LATTICE TOWER DBL DOUBLE X NEW LATTICE TOWER DA DOUBLE ARM — EXISTING 55KV CONDUCTOR DDE DOUBLE DEADEND — EXISTING 115KV CONDUCTOR DWN GUY DOWN GUY E EAST — EXISTING 230KV CONDUCTOR INST INSTALL NEW CONDUCTOR LATL LATERAL - REMOVED CONDUCTOR LB LOADBREAK MT MOUNT DOWN GUY NEUT NEUTRAL MULTIPLE DOWN GUYS N NORTH --�E� SPAN GUY OH OVERHEAD PUSH BRACE PH PHASE STREET LIGHT PTP POLE TOP PIN PRI PRIMARY o *-O STREET LIGHT WITH POLE RELOC RELOCATE D LINE CROSSING (PROFILE) REPL REPLACE s REMV REMOVE R/C RIGID CLEVIS - - SEE 0300.1000 FIGURE 5 FOR SVC SERVICE DISTRIBUTION SYMBOL LEGEND SGL SINGLE n SA SINGLE ARM S SOUTH SWBD SWITCH BOARDS SW GRDS SWITCH GROUNDS SW# SWITCH NUMBER TAN TANGENT TEL/TV TELEPHONE/TELEVISION TERM TERMINATION X-FER TRANSFER XFMR TRANSFORMER o XMSN TRANSMISSION TPLX TRIPLEX UG UNDERGROUND W WEST W/ WITH VERT VERTICAL 0 i SANTA FE Lij � W 7TH ST --- ----- --------- SHE T 2 LLJQ GRA TALBOT - METRO RENTON 115kV J ' ST 19 W_ m O J 167 = O m O UGET O� S 21 ST N ST `SO - ------------------- --------- - -------- s ----------------- VICINITY MAP ENGINEER: JOHN SEALY PROJECT NOTES PHONE: 425-516-4929 PROJECT SCOPE - TEMPORARY GUYING TO PROVIDE CLEARANCE FOR NEW CONSTRUCTION CONSTRUCTION NOTES - ALL CONSTRUCTION SHALL BE IN ACCORDANCE WITH THE STANDARD NOTES FOR WOOD POLES CONSTRUCTION, DWG D-12842 SH 1 OF 1. - THE ENGINEER SHALL BE CONTACTED WITH REGARDS TO ALL TECHNICAL INFORMATION. THE ENGINEER SHALL HAVE SOLE AUTHORITY TO APPROVE ANY AND ALL CONSTRUCTION CHANGES. - DESIGN DETAILS AND NOTES SHALL SUPPLEMENT THE STANDARDS REFERENCED IN THIS DRAWING. CALL (800)424-5555 2 BUSINESS DAYS BEFORE YOU DIG THIS SKETCH NOT TO BE RELIED UPON FOR EXACT LOCATION OF FACILITIES "Locates Required" Yes ❑ No❑ "Outages Required" Yes ❑ No❑ "Flagging Required" Yes ❑ No❑ C Im., TRANSFER SPAN GUY TO NEW POLE 0/14 ON THE TALBOT HILL — OBRIEN 02 LINE 3 ,619 L_— SHUFFLETON—OBRIEN S RENTON VILLAGE PL TALBOT HILL—OBRIEN #2 D r OD 0 —I i I � 0 X�� (n PLAN SCALE 1 "= 100, 0 0 0 0 0 no Ln o N POLE TABLE POLE GUYS ANCHORS POLE DRILLING DIST. OR STAKE STATION ACTION POLE LENGTH POLE CLASS SPECIFICATIONS 1025.1400 TYPE STANDARD PRACTICE FRAMING FROM GRID NUMBER REMARKS ACCESS NO CONSTRUCTION STD.PRAC. 6072.1000 REMARKS NO REVISION 16 OR QTY POLE TOP 6073.xxxx FIG ACTION 2/19 149+02 EXIST 60 1 FIG. 10 HPA 6085.1000 DESCRIPTION 317464-166021 2/20 '151 +44 EXIST 60 H2 FIG. 20 VDE-C 2152.9165 317438-166020 1 1 s2/20E EXIST 35 1 INSTALL STUB 3 7/16 SIDE DOWN 8' DOUBLE — GYT7S2 0100 6 INSTALL 2/21 154+89 EXIST 70 1 FIG. 10 1 HPA 16085.1000 3 317438-165993 0170 1 GUYING TABLE CALL (800)424-5555 2 BUSINESS DAYS BEFORE YOU DIG THIS SKETCH NOT TO BE RELIED UPON FOR EXACT LOCATION OF FACILITIES "Locates Required" Yes ❑ No❑ "Outages Required" Yes ❑ No❑ "Flagging Required" Yes ❑ No❑ GUYS ANCHORS POLE OR STAKE LEAD CONSTRUCTION STD.PRAC. CONSTRUCTION STD.PRAC. 6072.1000 REMARKS NO ACTION OR QTY UNIT 6073.xxxx FIG ACTION QTY UNIT SPAN DESCRIPTION DESCRIPTION FIG DET 2/20 INSTALL 20' E 3 7/16 SIDE DOWN 8' DOUBLE — GYT7S2 0100 6 INSTALL 2 PLATE 24 — 1 IN ROD — ANTP24 3 B SET ANCHOR AS STAKED$ ANCHORS MUST BE PLACED 5' APART 2/20 REUSE 80' S 3 7/16 SIDE SPAN 8' — GYT30S 0170 1 TRANSFER SPAN GUY TO POLE 0/14 TALBOT HILL — OBRIEN #2 2/20 REMOVE 148' E 3 3/8 SIDE SPAN 8' — GYT30S 0170 1 EXIST 2/20 1 REMOVE 15'920' E 2 7/16 STUB DOWN — GYT7S8 0170 3 CALL (800)424-5555 2 BUSINESS DAYS BEFORE YOU DIG THIS SKETCH NOT TO BE RELIED UPON FOR EXACT LOCATION OF FACILITIES "Locates Required" Yes ❑ No❑ "Outages Required" Yes ❑ No❑ "Flagging Required" Yes ❑ No❑