HomeMy WebLinkAboutMFP17003445DEPARTMENT OF COMMUNITY
AND ECONOMIC DEVELOPMENT
Franchise Permit: MFP17003445
IVR Number: 17003445
Permit Informa!on
Permit Name:Puget Sound Energy - Electric
Address/Loca!on:07/21/2017Applica!on Date:7564600170Parcel Number:315 GARDEN AVE N
Permit Type :07/24/2017Issue Date:Franchise
Permit Work Class:07/24/2018Expira!on Date :Minor U(lity
Job Number:#101105503Franchise Type :Electric
Descrip!on:INSTALL VAULTS PLACE 4" CONDUITS IN JOINT TRENCH (DUCTBANK) FOR FUTURE USE WHEN OVERHEAD IS
CONVERTED TO UNDERGROUND ALONG PARK AVE N BETWEEN N 3RD ST AND N 4TH ST FOR SARTORI ELEMENTARY
SCHOOL. This permit is to install the vaults and conduit. Separate permits are required later when u(li(es are installed
within the conduit. Restora(on per City of Renton Standards.
Contacts
Name Address PhoneTypeBilling
ANISH KUMAR
PUGET SOUND ENERGY - ELECTRIC - BILLING
6905 S 228th St
Kent, WA 98032
B: (253) 208-2183ApplicantX
VICKI HENSON
POTELCO INC
8001 212th St S
Kent, WA 98032
B: (253) 863-0484Contractor
Business License Number: BL.005109Electrical Contractor : POTELI*344O4
Construc!on Contractor : POTELI*227PL
Jace Munson
Forma Construc(on Company
PO BOX 11489
Olympia, WA 98508-1489
B: (360) 754-5788Contractor
Business License Number: BL.000137Construc!on Contractor : FORMACC878OR
CITY OF RENTON ROW 1055 S Grady Way
Renton, WA 98057-3232
Owner
RSD/Sartori School 315 Garden Ave N
Renton, WA 98057
Tenant
General Condi!ons & Signature
Permission is hereby given for the work described on this permit according to the conditions hereon and according to the
approved plans and specifications pertaining thereto, subject to compliance with the Ordinance of the City of Renton.
This permit and plans must be posted at the job site at all times.
I hereby certify that no work is to be done except as described above and in approved plans, and that work is to conform to
Renton Trench Restoration and Street Overlay Requirements.
Call (425) 430-7203 or go to: www.MyBuildingPermit.com one working day in advance to schedule an inspections and for
ANY work in the Right of Way.
Call 8 1 1 to locate underground utilities at least two full business days prior to any excavation.
In accordance with RCW 19.122.033(4) the permit holder is required to contact (Williams Northwest Pipeline at 425.868.1010
) (Olympic Pipeline at 206.510.0575)(Puget Sound Energy at 425.457.5816) to request a consultation with the transmission
pipeline company prior to performing any construction or excavation activities. This requirement to consult with the
transmission pipeline company is in addition to the requirement to Call before You Dig as required in RCW 19.122.
(Date)(Signature)
Page 1 of 2THIS PERMIT AND PLANS MUST BE POSTED AT THE JOB SITE AT ALL TIMES
MFP17003445
Holly Powers
Restoration per City of Renton Standards
Justin Johnson 7-24-2017
7/24/2017
MFP17003445
Justin Johnson
7-24-2017
Monday through Friday
PrintFormfResetForm7TRAFFICCONTROLPLAN*PROJECTNAME:________________________________________PERMIT#UIO(‘79‘CONSTRUCTIONCOMPANY:o,qf”vc..4,0i’JPHONE#:3LO-fq-5?CONTACTNAME:c41qpJPHONE#:S3-cl33ADDRESS:AU€.Ol.p;v4W1.‘t851c3-CELL#:I3’3C&E-MAILADDRESS:5k.ke,CCL4AFAX#:___________PROJECTLOCATION:33P,q-ksue.tJ,R.e..c4e%Jk)4N/E/S/WOF:________________*SeenoteonWORKTIME:O4o3cppage2.APPROVEDBY:(1WORKDATE:5/25/2017-08/31/2017APPROVALDATE:05/24/2017PermitHolderagreestoallthefollowing:•ComplywithalltrafficregulationsoftheCityofRentonandtheStateofWashington.•PrepareatrafficcontrolplanandobtainCityapprovalofthatplan.Thatplanshallbeimplementedforallstreetandlaneclosures,andtheplanshallbeperformedincompliancewiththeManualonUniformTrafficControlDevices.•Notifyemergencyservices(253-852-2121)twenty-four(24)hoursbeforeanystreetorlaneclosures.•Anylaneorstreetclosuresnotinconformancewiththeapprovedtrafficcontrolplanand/orwithoutnotificationofemergencyservicesmayresultinreceivingacitationforviolationofR.C.W.47.36.200through47.36.220,9A.36.050RecklessEndangerment,andotherapplicableStateandCitycodes.•IndemnifyandholdharmlesstheCityofRentonfromanyandallclaims,actions,andjudgments,includingallcostsofdefenseandattorney’sfeesincurredindefendingagainstsame,arisingfromandrelatedtoimplementationoftheapprovedtrafficcontrolplansincludingclaimsarisingfromtowingofprivatevehiclesandtheactsofthePermitHolder’sagentsandemployees.•TheCityofRentonshallbeentitled,initsreasonablediscretion,tosettleclaimspriortosuitorjudgment,andinsucheventshallindemnifyandholdharmlesstheCityforanysuchclaimspaid,includingtheCity’sreasonableattorney’sfeesandlitigationcostsincurredresultingfromsuchclaim.•IntheeventanyclaimorsuitisbroughtagainstCitywithinthescopeofthisAgreement,PermitHolderwillpayforlegalcounselchosenbytheCitytodefendagainstsame.•FlaggerandsignplacementaresubjecttorevisionbytheCityInspectoronsite,ifneededtoaddresstrafficorpedestriansafetyortravel.•Bymysignatureherein,Iacknowledgealltheaboverequirements.PRINTNAME:Z3out’ttLI5i’1SIGNATURE:OFFICECOPY11189CONTRACTORemail0EV.SERVICE,INSPECTIONP.MILLERDEV.SERVICE,PLANREVIEWB.BANNWARTHPOLICECHARLESKARLEWICZFIREFIREMARSHALLFS#131’MFP17003445
1) See attached plan.
2) For the double lane closure on
N 3rd, only one lane can be taken
between 7am - 8:30am. The
double lane closure can only be
allowed between 8:30am - 3:30pm.
EXISTING TRAFFIC FLOW
SIGN LOCATION
28” TRAFFIC CONE
WORK AREA
LEGEND
ARROWBOARD
LOCATION
ROADWORKAHEADW20-1LEFT LANECLOSEDAHEADW20-5LW4-2RROAD
WORK
AHEAD W20-1
ROAD
WORK
AHEAD W20-1
GENERAL NOTES
1. ALL SIGNS AND SPACING SHALL CONFORM TO THE MUTCD AND
CITY OF RENTON SPECS.
2. NOTIFY ALL LOCAL EMERGENCY SERVICES OF CLOSURE TIMES
AND DATES.
3. THIS SIGN SPACING MAY BE REDUCED IN URBAN AREAS TO FIT
ROADWAY CONDITIONS.
4. ALERT PUBLIC TRANSIT 5 DAYS IN ADVANCE (IF APPLICABLE).
5. PROTECTIVE VEHICLE RECOMMENDED-MAY BE A WORK VEHICLE.
6. ALL SIGNS min. 48” X 48” B/O UNLESS OTHERWISE SPECIFIED.
7. CHANNELIZATION DEVICES ARE 28” REFL. CONES. (see TABLE 1
for spacing distances).
8. ALL SPACING MAY BE ADJUSTED TO ACCOMMODATE AT GRADE
INTERSECTIONS AND/OR DRIVEWAYS.
TABLE 1
NOT TO
SCALE
N 4th ST
GARDEN AVEMEADOWS WAYPrepared By
Project/Job Number
Sheet Number
Contractor
Phone Number (office) Project Location
Supervisor
DatePhone Number (fax)
Iliad NW
David Dorland
1 of 6 05.15.17
R. Guzman NATIONAL BARRICADE CO. LLC
ESTABLISHED IN 1951
E-mail
206.282.4200
rayg@barricade.com O: 206.523.4045 F: 253.735.6329
NATIONAL BARRICADE CO. LLC
ESTABLISHED IN 19511/31/20
Exp.Date
Traffic Control Supervisor
Card # 010125
Traffic Plan Designer
Raymond Guzman
Evergreen Safety Council
Sartori School Renton
Renton, WAW4-119R* Use Standard Plan K-24.40-01 - Double
Lane Closure on Multilane Roadway.
Type III Barricade
"Left Two Lanes Closed Ahead"X501••••.
.•I•.
ROAD
WORK
AHEAD W20-1
ROAD
WORK
AHEAD W20-1
GENERAL NOTES
1. ALL SIGNS AND SPACING SHALL CONFORM TO THE MUTCD AND
CITY OF RENTON SPECS.
2. NOTIFY ALL LOCAL EMERGENCY SERVICES OF CLOSURE TIMES
AND DATES.
3. THIS SIGN SPACING MAY BE REDUCED IN URBAN AREAS TO FIT
ROADWAY CONDITIONS.
4. ALERT PUBLIC TRANSIT 5 DAYS IN ADVANCE (IF APPLICABLE).
5. PROTECTIVE VEHICLE RECOMMENDED-MAY BE A WORK VEHICLE.
6. ALL SIGNS min. 48” X 48” B/O UNLESS OTHERWISE SPECIFIED.
7. CHANNELIZATION DEVICES ARE 28” REFL. CONES. (see TABLE 1
for spacing distances).
8. ALL SPACING MAY BE ADJUSTED TO ACCOMMODATE AT GRADE
INTERSECTIONS AND/OR DRIVEWAYS.
TABLE 1
N 4th ST
GARDEN AVEMEADOWS WAYPrepared By
Project/Job Number
Sheet Number
Contractor
Phone Number (office) Project Location
Supervisor
DatePhone Number (fax)
Iliad NW
David Dorland
2 of 6 05.15.17
R. Guzman NATIONAL BARRICADE CO. LLC
ESTABLISHED IN 1951
E-mail
206.282.4200
rayg@barricade.com O: 206.523.4045 F: 253.735.6329
NATIONAL BARRICADE CO. LLC
ESTABLISHED IN 19511/31/20
Exp.Date
Traffic Control Supervisor
Card # 010125
Traffic Plan Designer
Raymond Guzman
Evergreen Safety Council
Sartori School Renton
Renton, WAW4-2LRIGHT LANECLOSEDAHEADW20-5RROADWORKAHEADW20-1W4-119LEXISTING TRAFFIC FLOW
SIGN LOCATION
28” TRAFFIC CONE
WORK AREA
LEGEND
ARROWBOARD
LOCATION
NOT TO
SCALE* Use Standard Plan K-24.40-01 - Double
Lane Closure on Multilane Roadway.
Type III Barricade ••••..•I•."Right Two Lanes Closed Ahead"X501
EXISTING TRAFFIC FLOW
SIGN LOCATION
28” TRAFFIC CONE
WORK AREA
LEGEND
ARROWBOARD
LOCATION ROADWORKAHEADW20-1RIGHT LANECLOSEDAHEADW20-5RROAD
WORK
AHEAD W20-1
GENERAL NOTES
1. ALL SIGNS AND SPACING SHALL CONFORM TO THE MUTCD AND
CITY OF RENTON SPECS.
2. NOTIFY ALL LOCAL EMERGENCY SERVICES OF CLOSURE TIMES
AND DATES.
3. THIS SIGN SPACING MAY BE REDUCED IN URBAN AREAS TO FIT
ROADWAY CONDITIONS.
4. ALERT PUBLIC TRANSIT 5 DAYS IN ADVANCE (IF APPLICABLE).
5. PROTECTIVE VEHICLE RECOMMENDED-MAY BE A WORK VEHICLE.
6. ALL SIGNS min. 48” X 48” B/O UNLESS OTHERWISE SPECIFIED.
7. CHANNELIZATION DEVICES ARE 28” REFL. CONES. (see TABLE 1
for spacing distances).
8. ALL SPACING MAY BE ADJUSTED TO ACCOMMODATE AT GRADE
INTERSECTIONS AND/OR DRIVEWAYS.
TABLE 1
NOT TO
SCALE
Prepared By
Project/Job Number
Sheet Number
Contractor
Phone Number (office) Project Location
Supervisor
DatePhone Number (fax)
Iliad NW
David Dorland
3 of 6 05.15.17
R. Guzman NATIONAL BARRICADE CO. LLC
ESTABLISHED IN 1951
E-mail
206.282.4200
rayg@barricade.com O: 206.523.4045 F: 253.735.6329
NATIONAL BARRICADE CO. LLC
ESTABLISHED IN 19511/31/20
Exp.Date
Traffic Control Supervisor
Card # 010125
Traffic Plan Designer
Raymond Guzman
Evergreen Safety Council
Sartori School Renton
Renton, WAROADWORKAHEADW20-1LEFT LANECLOSEDAHEADW20-5LPARK AVE N N 3RD STN 4TH STW1-4L••••..•I•.
ROADWORKAHEADW20-1ROADWORKAHEADW20-1 GENERAL NOTES
1. ALL SIGNS AND SPACING SHALL CONFORM TO THE MUTCD AND
CITY OF RENTON SPECS.
2. NOTIFY ALL LOCAL EMERGENCY SERVICES OF CLOSURE TIMES
AND DATES.
3. THIS SIGN SPACING MAY BE REDUCED IN URBAN AREAS TO FIT
ROADWAY CONDITIONS.
4. ALERT PUBLIC TRANSIT 5 DAYS IN ADVANCE (IF APPLICABLE).
5. PROTECTIVE VEHICLE RECOMMENDED-MAY BE A WORK VEHICLE.
6. ALL SIGNS min. 48” X 48” B/O UNLESS OTHERWISE SPECIFIED.
7. CHANNELIZATION DEVICES ARE 28” REFL. CONES. (see TABLE 1
for spacing distances).
8. ALL SPACING MAY BE ADJUSTED TO ACCOMMODATE AT GRADE
INTERSECTIONS AND/OR DRIVEWAYS.
TABLE 1
NOT TO
SCALE
N 3RD STPARK AVE NGARDEN AVE SPELLY AVE NROAD
WORK
AHEAD W20-1
Prepared By
Project/Job Number
Sheet Number
Contractor
Phone Number (office) Project Location
Supervisor
DatePhone Number (fax)
Iliad NW
David Dorland
4 of 6 05.15.17
R. Guzman NATIONAL BARRICADE CO. LLC
ESTABLISHED IN 1951
E-mail
206.282.4200
rayg@barricade.com O: 206.523.4045 F: 253.735.6329
NATIONAL BARRICADE CO. LLC
ESTABLISHED IN 19511/31/20
Exp.Date
Traffic Control Supervisor
Card # 010125
Traffic Plan Designer
Raymond Guzman
Evergreen Safety Council
Sartori School Renton
Renton, WA
EXISTING TRAFFIC FLOW
SIGN LOCATION
28” TRAFFIC CONE
WORK AREA
LEGEND
ARROWBOARD
LOCATION W4-119RW4-2RLEFT LANE
CLOSED
AHEAD W20-5L
* Use Standard Plan K-24.40-01 - Double Lane Closure on
Multilane Roadway.
* The work hours for this plan is from 8:30am - 3:30pm.
"Left Two Lanes Closed Ahead"
X 501
Type III Barricade
ROADWORKAHEADW20-1ROADWORKAHEADW20-1 GENERAL NOTES
1. ALL SIGNS AND SPACING SHALL CONFORM TO THE MUTCD AND
CITY OF RENTON SPECS.
2. NOTIFY ALL LOCAL EMERGENCY SERVICES OF CLOSURE TIMES
AND DATES.
3. THIS SIGN SPACING MAY BE REDUCED IN URBAN AREAS TO FIT
ROADWAY CONDITIONS.
4. ALERT PUBLIC TRANSIT 5 DAYS IN ADVANCE (IF APPLICABLE).
5. PROTECTIVE VEHICLE RECOMMENDED-MAY BE A WORK VEHICLE.
6. ALL SIGNS min. 48” X 48” B/O UNLESS OTHERWISE SPECIFIED.
7. CHANNELIZATION DEVICES ARE 28” REFL. CONES. (see TABLE 1
for spacing distances).
8. ALL SPACING MAY BE ADJUSTED TO ACCOMMODATE AT GRADE
INTERSECTIONS AND/OR DRIVEWAYS.
TABLE 1
NOT TO
SCALE
N 3RD STPARK AVE NGARDEN AVE SPELLY AVE NROAD
WORK
AHEAD W20-1
Prepared By
Project/Job Number
Sheet Number
Contractor
Phone Number (office) Project Location
Supervisor
DatePhone Number (fax)
Iliad NW
David Dorland
5 of 6 05.15.17
R. Guzman NATIONAL BARRICADE CO. LLC
ESTABLISHED IN 1951
E-mail
206.282.4200
rayg@barricade.com O: 206.523.4045 F: 253.735.6329
NATIONAL BARRICADE CO. LLC
ESTABLISHED IN 19511/31/20
Exp.Date
Traffic Control Supervisor
Card # 010125
Traffic Plan Designer
Raymond Guzman
Evergreen Safety Council
Sartori School Renton
Renton, WA
EXISTING TRAFFIC FLOW
SIGN LOCATION
28” TRAFFIC CONE
WORK AREA
LEGEND
ARROWBOARD
LOCATION
W4-119LRIGHT LANECLOSEDAHEADW20-5RW4-2L* Use Standard Plan K-24.40-01 - Double Lane Closure on
Multilane Roadway.
* The work hours for this plan is from 8:30am - 3:30pm."Right Two Lanes Closed Ahead"X501Type III Barricade
SHOULDER
CLOSED
W20-301
SHOULDER
WORK
W21-5
WORK AREA
EXISTING TRAFFIC FLOW
LEGEND
SIGN LOCATION
T-39 NO PARKING
28” TRAFFIC CONE
ROAD
WORK
AHEAD
W20-1
GENERAL NOTES
1. ALL SIGNS AND SPACING SHALL CONFORM TO THE MUTCD AND
CITY OF RENTON SPECS.
2. NOTIFY ALL LOCAL EMERGENCY SERVICES OF CLOSURE TIMES
AND DATES.
3. THIS SIGN SPACING MAY BE REDUCED IN URBAN AREAS TO FIT
ROADWAY CONDITIONS.
4. ALERT PUBLIC TRANSIT 5 DAYS IN ADVANCE (IF APPLICABLE).
5. PROTECTIVE VEHICLE RECOMMENDED-MAY BE A WORK VEHICLE.
6. ALL SIGNS min. 48” X 48” B/O UNLESS OTHERWISE SPECIFIED.
7. CHANNELIZATION DEVICES ARE 28” REFL. CONES. (see TABLE 1
for spacing distances).
8. ALL SPACING MAY BE ADJUSTED TO ACCOMMODATE AT GRADE
INTERSECTIONS AND/OR DRIVEWAYS.
TABLE 1
Prepared By
Project/Job Number
Sheet Number
Contractor
Phone Number (office) Project Location
Supervisor
DatePhone Number (fax)
Iliad NW
David Dorland
6 of 6 05.15.17
R. Guzman NATIONAL BARRICADE CO. LLC
ESTABLISHED IN 1951
E-mail
206.282.4200
rayg@barricade.com O: 206.523.4045 F: 253.735.6329
NATIONAL BARRICADE CO. LLC
ESTABLISHED IN 19511/31/20
Exp.Date
Traffic Control Supervisor
Card # 010125
Traffic Plan Designer
Raymond Guzman
Evergreen Safety Council
Sartori School Renton
Renton, WA
NOT TO
SCALE
* No Parking signs must be placed at
least 72 hours in advance.
EXISTING TRAFFIC FLOW
SIGN LOCATION
28” TRAFFIC CONE
WORK AREA
LEGEND
ARROWBOARD
LOCATION ROADWORKAHEADW20-1RIGHT LANECLOSEDAHEADW20-5RROAD
WORK
AHEAD W20-1
GENERAL NOTES
1. ALL SIGNS AND SPACING SHALL CONFORM TO THE MUTCD AND
CITY OF RENTON SPECS.
2. NOTIFY ALL LOCAL EMERGENCY SERVICES OF CLOSURE TIMES
AND DATES.
3. THIS SIGN SPACING MAY BE REDUCED IN URBAN AREAS TO FIT
ROADWAY CONDITIONS.
4. ALERT PUBLIC TRANSIT 5 DAYS IN ADVANCE (IF APPLICABLE).
5. PROTECTIVE VEHICLE RECOMMENDED-MAY BE A WORK VEHICLE.
6. ALL SIGNS min. 48” X 48” B/O UNLESS OTHERWISE SPECIFIED.
7. CHANNELIZATION DEVICES ARE 28” REFL. CONES. (see TABLE 1
for spacing distances).
8. ALL SPACING MAY BE ADJUSTED TO ACCOMMODATE AT GRADE
INTERSECTIONS AND/OR DRIVEWAYS.
TABLE 1
NOT TO
SCALE
Prepared By
Project/Job Number
Sheet Number
Contractor
Phone Number (office) Project Location
Supervisor
DatePhone Number (fax)
Iliad NW
David Dorland
3 of 6 05.15.17
R. Guzman NATIONAL BARRICADE CO. LLC
ESTABLISHED IN 1951
E-mail
206.282.4200
rayg@barricade.com O: 206.523.4045 F: 253.735.6329
NATIONAL BARRICADE CO. LLC
ESTABLISHED IN 19511/31/20
Exp.Date
Traffic Control Supervisor
Card # 010125
Traffic Plan Designer
Raymond Guzman
Evergreen Safety Council
Sartori School Renton
Renton, WAROADWORKAHEADW20-1LEFT LANECLOSEDAHEADW20-5LPARK AVE N N 3RD STN 4TH STW1-4L
ONE WAY
1111111118
18ONE WAY
111111N 4th St
Garden Ave NN 3rd St
J
J
J01
J02
V02
POLICE
UPO R9-9SIDEWALKCLOSEDR9-11SIDEWALK
CLOSED
AHEAD
DETOUR M4-9bDETOURM4-9b
R9-11SIDEWALKCLOSEDAHEADR9-9SIDEWALKCLOSEDSTOP
```8_X_10-PLATE8_X_10-PLATE
ONE LANE
ROAD
AHEAD W20-4ROAD
WORK
AHEAD W20-1W20-7A100'100'100'ONE LANEROADAHEADW20-4ROADWORKAHEADW20-1W20-7A100'100'100'W4-2R
ROADWORKAHEADW20-1 LEFT LANECLOSEDAHEADW20-5L
100'100'100'
W4-2RROADWORKAHEADW20-1 LEFT LANECLOSEDAHEADW20-5L
100'100'100'ARRW-
BR
D
BEPREPAREDTOSTOPW3-4
W20-7A
100'100'BEPREPAREDTOSTOPW3-4
W20-7A
100'100'
CREW WILL USE ADA COMPLIANT
RAMPS FOR PEDESTRIAN
DIVERSION
FROM TO
TOW AWAY AREA
PHONE 888-9999
INFRASOURCE LLC 000 0000000
NO PARKING
NO-PARK
PLACE SIGNS ON
BOTH SIDES OF
GARDEN AVE N
RESIDENT(S) WILL BE INFORMED
OF POSSIBLE TEMPORARY
DRIVEWAY CLOSURE
1818
PEDESTRIAN PATHWAY
CHANNELIZATION
DEVICE SPACING
MPH
55/70
35/45
25/30
TAPER
40
30
20
TANGENT
80
60
40
N
PSE PUGET
SOUND
ENERGY
Job#101105503
315 Garden Ave N Renton, WA
June 26th, 2017
Sheet 1 of 3 mitchell.peterson@pse.com
425-398-6071
PRINT ON
11X17" SHEETS ONLY
Notes:
1. All signs and spacing to conform to the MUTCD
and City of Renton standards.
2. All sidewalks, driveways, exits and egresses
shall be completely clear unless otherwise indicated.
3. Channelizing devices are 28" traffic cones.
4. Sign size can be a minimum of 48" x 48" and
shall not obstruct pedestrian access.
5. Crew is required to leave a minimum of 11' for
traveling lane width.
6. Alert affected residents and businesses.
7. Work to take place between 9 a.m. and 4 p.m.
PSE
Traffic Control Supervisor:
Eduard Volianskyi
Card No. 010041
Card Exp. 11/30/2019
Eduard.Volianskyi@pse.com
(425) 4246428
28" TRAFFIC CONE
LEGEND
TRAFFIC FLOW
WORK VEHICLE
SIGN LOCATION
WARNING FLAG
FLAGGER
UNIFORMED
POLICE OFFICERPOLICE
STOP
ARROW BOARD
VAULTVault
ONE WAY
1111111118
18ONE WAY
111111N 4th St
Garden Ave NN 3rd St
V02
V02
STOP
```8_X_10-PLATEONE LANEROADAHEADW20-4ROADWORKAHEADW20-1W20-7A100'100'100'CREW WILL USE ADA COMPLIANT
RAMPS FOR PEDESTRIAN
DIVERSION
FROM TO
TOW AWAY AREA
PHONE 888-9999
INFRASOURCE LLC 000 0000000
NO PARKING
NO-PARK
PLACE SIGNS ON
BOTH SIDES OF
GARDEN AVE N
1818
8_X_1
0
-P
L
AT
E
STOP
FLAGGER
ONE LANE
ROAD
AHEAD W20-4ROAD
WORK
AHEAD W20-1W20-7A100'100'100'ROADWORKAHEADW20-1ROADWORKAHEADW20-1
RESIDENT(S) WILL BE INFORMED
OF POSSIBLE TEMPORARY
DRIVEWAY CLOSUREROADWORKAHEADW20-1ROADWORKAHEADW20-11218
R9-9SIDEWALK
CLOSED R9-9SIDEWALKCLOSEDPEDESTRIAN PATHWAY
CHANNELIZATION
DEVICE SPACING
MPH
55/70
35/45
25/30
TAPER
40
30
20
TANGENT
80
60
40
N
PSE PUGET
SOUND
ENERGY
Job#101105503
315 Garden Ave N Renton, WA
June 26th, 2017
Sheet 2 of 3 mitchell.peterson@pse.com
425-398-6071
PRINT ON
11X17" SHEETS ONLY
Notes:
1. All signs and spacing to conform to the MUTCD
and City of Renton standards.
2. All sidewalks, driveways, exits and egresses
shall be completely clear unless otherwise indicated.
3. Channelizing devices are 28" traffic cones.
4. Sign size can be a minimum of 48" x 48" and
shall not obstruct pedestrian access.
5. Crew is required to leave a minimum of 11' for
traveling lane width.
6. Alert affected residents and businesses.
7. Work to take place between 9 a.m. and 4 p.m.
PSE
Traffic Control Supervisor:
Eduard Volianskyi
Card No. 010041
Card Exp. 11/30/2019
Eduard.Volianskyi@pse.com
(425) 4246428
28" TRAFFIC CONE
LEGEND
TRAFFIC FLOW
WORK VEHICLE
SIGN LOCATION
WARNING FLAG
FLAGGER
STOP
VAULTVault
ONE WAY
1111111118
18ONE WAY
111111N 4th St
Garden Ave NN 3rd St
V02
PV1
CREW WILL USE ADA COMPLIANT
RAMPS FOR PEDESTRIAN
DIVERSION
FROM TO
TOW AWAY AREA
PHONE 888-9999
INFRASOURCE LLC 000 0000000
NO PARKING
NO-PARK
PLACE SIGNS ON
BOTH SIDES OF
GARDEN AVE N
1818
8_X_1
0
-P
L
AT
E
STOP
FLAGGER
ONE LANE
ROAD
AHEAD W20-4ROAD
WORK
AHEAD W20-1W20-7A100'100'100'RESIDENT(S) WILL BE INFORMED
OF POSSIBLE TEMPORARY
DRIVEWAY CLOSURE12188_X_10-
P
LA
TE
POLICE
UPO BEPREPAREDTOSTOPW3-4ROADWORKAHEADW20-1W20-7A100'100'100'BEPREPAREDTOSTOPW3-4ROADWORKAHEADW20-1W20-7A100'100'100'BEPREPAREDTOSTOPW3-4ROADWORKAHEADW20-1W20-7A100'100'100'PEDESTRIAN PATHWAY
R9-9SIDEWALK
CLOSED R9-9SIDEWALKCLOSEDR9-11SIDEWALKCLOSEDAHEADDETOURM4-9bCHANNELIZATION
DEVICE SPACING
MPH
55/70
35/45
25/30
TAPER
40
30
20
TANGENT
80
60
40
N
PSE PUGET
SOUND
ENERGY
Job#101105503
315 Garden Ave N Renton, WA
June 26th, 2017
Sheet 3 of 3 mitchell.peterson@pse.com
425-398-6071
PRINT ON
11X17" SHEETS ONLY
Notes:
1. All signs and spacing to conform to the MUTCD
and City of Renton standards.
2. All sidewalks, driveways, exits and egresses
shall be completely clear unless otherwise indicated.
3. Channelizing devices are 28" traffic cones.
4. Sign size can be a minimum of 48" x 48" and
shall not obstruct pedestrian access.
5. Crew is required to leave a minimum of 11' for
traveling lane width.
6. Alert affected residents and businesses.
7. Work to take place between 9 a.m. and 4 p.m.
PSE
Traffic Control Supervisor:
Eduard Volianskyi
Card No. 010041
Card Exp. 11/30/2019
Eduard.Volianskyi@pse.com
(425) 4246428
28" TRAFFIC CONE
LEGEND
TRAFFIC FLOW
WORK VEHICLE
SIGN LOCATION
WARNING FLAG
FLAGGER
UNIFORMED
POLICE OFFICERPOLICE
STOP
ARROW BOARD
VAULTVault
NOTES PROVIDED BY BCE ENGINEERS
AND INTEGRUS ARCHITECTURE IN
COORDINATION WITH CCD-011 ISSUED
7/12/17
STUB OUT WITH
RIGID CAP AND
ELECTRONIC BALL
MARKER (BCE)
NOT
USED
TO BE PROVIDED PER
REVISED KEYNOTE 2,
E101 (IA)
PROVIDE STUB
OUT WITH RIGID
CAP AND
ELECTRONIC BALL
MARKER FOR
FUTURE
CROSSING FOR
CENTURY LINK,
QTY ON PARK AVE
TO MATCH
EXISTING
CROSSINGS (IA)
PROVIDE STUB OUT WITH RIGID
CAP AND ELECTRONIC BALL
MARKER FOR FUTURE
CROSSING FOR CENTURYLINK,
QTY ON PARK AVE TO MATCH
EXISTING CROSSINGS (IA)
ALL STUB OUTS FOR
FUTURE CROSSINGS OF
PARK AVE N TO BE WEST
OF NEW SIDEWALK (IA)
DEPTH AS REQUIRED FOR
36" MINIMUM COVER BELOW
WATER MAIN INSTALLATION
AS SHOWN ON C6.2 AND
C6.3 (IA)
12" MIN
RSD FIBER 1-4"
CITY OF RENTON 1-2"
PROVIDE STUB OUT WITH RIGID
CAP AND ELECTRONIC BALL
MARKER FOR FUTURE
COMCAST VAULT, ADJACENT
TO EXISTING RISER (IA)
STUB CONDUITS
WEST OF NEW
SIDEWALK AT
PARK AVE N.
PROVIDE RIGID
CAP AND
ELECTRONIC BALL
MARKER. (BCE)
STUB OUT WITH
RIGID CAP AND
ELECTRONIC BALL
MARKER (BCE)
PROVIDE STUB OUT WITH RIGID
CAP AND ELECTRONIC BALL
MARKER FOR FUTURE
CROSSING FOR CENTURY LINK,
QTY ON PARK AVE TO MATCH
EXISTING CROSSINGS (IA)
PROVIDE STUB
OUT WITH RIGID
CAP AND
ELECTRONIC BALL
MARKER FOR
FUTURE centurylink
VAULT, ADJACENT
TO EXISTING
VAULT (IA)
PROVIDE STUB OUT WITH RIGID
CAP AND ELECTRONIC BALL
MARKER FOR FUTURE
CROSSING FOR CENTURYLINK
QTY ON PARK AVE TO MATCH
EXISTING CROSSINGS (IA)
ALL STUB OUTS FOR
FUTURE CROSSINGS OF
PARK AVE N TO BE WEST
OF NEW SIDEWALK (IA)