Loading...
HomeMy WebLinkAboutP_Drawing_105085669_V1_170810A B 10"FUSE @ 40T SW#T79023 GAS PHONE CABLE TV PROJECT PHASE PWR NOTIF#ORDER# Superior PSE No No No Yes Yes Yes No YesDeveloper "Flagging Required" "Outages Required" "Locates Required"THIS SKETCH NOT TO BE RELIED UPON FOR EXACT LOCATION OF EXISTING FACILITIES CALL (800) 424-5555 2 BUSINESS DAYS BEFORE YOU DIG For contacts below dial 1-888-CALL PSE (225-5773)105085669Owner / Developer Contact Info officeATTN: KUSHAL VARMA 10906 144TH AVE SE RENTON, WA 98059 KUSHAL VARMA (206) 353-3168 N Vicinity Map NOT TO SCALE FOREMAN (CHECK BOX WHEN COMPLETED) PSE Equipment LOCKED/SECURED & Work Area left in CLEAN/SAFE Condition. Grid, Cable, and Switch numbers INSTALLED & VERIFIED. Field Changes RED-LINED on As-built. Indicate correct FUSE SIZE on As-built & VERIFY proper PHASE. Foreman's Signature _______________________________________________ Print Name ___________________________________ Date ______________ Material VERIFIED and CHANGES noted on Paperwork. Total PRIMARY Cable noted on As-built. Company ID#'s RECORDED in correct location on As-built. Correct QC Checklist(s) reviewed. Deviations noted on the As-built and their reason. I certify that the work performed meets PSE's standards and procedures and that all quality requirements are met. DESIGNED BY UTILITIES CONTACT PHONE# COUNTY 1/4 SEC U-MAP NO (POWER) OP MAP Emer Sect Gas Wk Ctr POWER WK CTR PLAT MAP JOINT FACILITIES ARRANGEMENTS DRAWN BY CHECKED BY APPROVED BY FOREMAN #1 FOREMAN #2 MAPPING INCIDENT MAOP Gas Order Elect Order SCALE PAGE ENGR - POWER ENGR - GAS FUNCTION PROJECT MGR PERMITREAL ESTATE/EASEMENT 2 1 REV# 3 DATE DESCRIPTIONBY CONTACT PHONE NO DATE OH CKT MAP CIRCUIT NOUG CKT MAP R. PAGE (253) 234-6444 - R. PAGE (253) 234-6444 - T. MYER (714) 893-2405 07/11/17 R/W REQ KING COUNTY VARMA RESIDENCE NEW 320A REMOTE TEMP SERVICE 13010 156TH AVE SE, RENTON, WA 98059 ASPLUNDH CONSTRUCTION CORP. N/A N/A N/A 105085669 AS NOTED 1 OF 1 KING N/A N/A CSPSKEIN NE 14-23N-05E N/A N/A 2305E053 2306E076 MAP-13 2305E053 504686152 105085669 ARE TO BE INSTALLED, CROSS SECTION DETAILS OF THE TYPICAL EROSION STRUCTURES, & SPECIAL REQUIREMENTS FOR WORK IN SENSITIVE AREAS.) EROSION & SEDIMENT CONTROL REQUIREMENTS NOTES DETAILING WHERE EROSION OR SEDIMENT CONTROL STRUCTURES (LOCAL JURISDICTIONS MAY HAVE ADDITIONAL REQUIREMENTS INCLUDING 0150.3200 TECHNIQUES FOR TEMPORARY EROSION & SEDIMENT CONTROL EROSION & SEDIMENT CONTROL SHALL BE PER PSE STANDARD PRACTICE & ANY ADDITIONAL LOCAL JURISDICTION REQUIREMENTS. SITE MAP SCALE: 1" = 50' CIRCUIT FEET ADDED: 345' TRENCH DETAIL Electric Service Cable in Conduit (NTS) Electric Service Cable in Conduit Excavated Dirt Pile Final Grade 24" Min 24" Min to 36" Max Cover 12" Typical (6" Min) Backfill for Conduit Free of rocks larger than 8" in diameter) 36" MINIMUM COVER IN RIGHT OF WAY To Excavated Dirt Pile 3" Schedule 40 Grey PVC Backfill for In Conduit - The backfill layer shall be soil that is free from construction debris, glass, sharp rocks, frozen clods, and rocks larger than 8" in diameter. SQ. FOOTAGE: 4,224 SQ FT PANEL SIZE: 320A HEAT TYPE: GAS EST. DEMAND: 16KW LRC: 140A % V. DROP: 1.6% % FLICKER: 3.9% JOB SITE PARCEL # 3664500184 Installed at site: Grid Number: kVA Rating: Foreman to redline the following information TRANSFORMER INSTALLATION Company ID#: Primary phase connected to: Tested Secondary Voltage V01 317996-167938 37.5kVA NEW CABLE & CONDUIT DIAGRAM NOT TO SCALE 32" Typical 24" Min 24"-36" 24"-36" 4'Top View Electric & Joint Utility Work Pit Dimensions 36" Min Drainage Pipe 12" Minimum Clearance from Gas Service Lines Conduit Depth 24" to 36" Max Regulator Vent Gas Meter Assembly Utility Provided 48" 4'8" Service (Permanent Detail:) Not to Scale Seal Conduit Ends Closed 4'8" 24" Min 36" Typical 3' To Trench Property Line Conduit Stakes Customer Provided 3" Schedule 40 Grey PVC Power Cable Conduit Customer Provided Gas Service Line Conduit Sch 40 White PVC Customer Provided 3" Conduit Service Riser Customer Provided Elec. Mtr Base Elec Mtr utility provided Gas Meter Relief Vent Building Wall Elec. Mtr SCALE: NONE METER DETAIL @ M01 CIRCUIT LOADING TABLE AS OF EXIST. PEAK LOAD EST. NEW LOAD TOTAL CIRCUIT: A PHASE B PHASE C PHASE MAP-13 06.08.17 49 8 32 2 49 10 32 SITE SPECIFIC NOTES P01: 317998-167911 ,167$//‘35,7(50 /%&2)86(#7 7$3%‘ -INSTALL 2" CONDUIT RISER ON S/O BRACKETS (RIS2CSS) PER STD 6042.1000 -INSTALL CABLE TAG -INSTALL SWITCH #T79023 V01: 317996-167938 ,167$//´;´;´03++ *5'6 -INSTALL 37.5KVA 1PH 120/240V TRF -INSTALL 1-12KV L/B ELBOW -INSTALL SEC. CONNECTORS ,167$//&$%/(%‘(+0 -INSTALL GRID #317996-167938 M01: NEW REMOTE TEMP METER -INSTALL 320A METER CUSTOMER & DEVELOPER NOTES THE CUSTOMER IS RESPONSIBLE TO PROVIDE ALL TRENCHING, SELECT BACKFILL, COMPACTION & RESTORATION PER PUGET SOUND ENERGY STANDARDS 6750.6500 5(48,5('72&86720(5723$<)25'(',&$7(')$&,/,7,(6“  6((7$%/( 5(48,5('723529,'( ,167$//´12132/<38//523(,1$//&21'8,76 -REQUIRED TO PROVIDE 4' X 4' WORK PIT & 1 CUBIC YARD 5/8" CRUSHED ROCK AT P01 5(48,5('723529,'(¶;¶:25.3,79 5(48,5('723529,'(¶;¶:25.3,7 &8%,&<$5'2)6$1'$70 -REQUIRED TO FOLLOW ALL TRENCH DETAILS ON SELECT BACKFILL -REQUIRED TO PROVIDE EQUIPMENT TO PUMP OUT WATER FOR WORK PITS & TRENCH AT ALL TIMES -REQUIRED TO EXCAVATE & EXPOSE EXISTING PSE UG FACILITIES 48 HOURS PRIOR TO CONSTRUCTION -PSE INSPECTION IS REQUIRED PRIOR TO FINAL BACKFILL -PSE WILL NOT ENERGIZE FACILITIES UNTIL BACKFILL IS COMPLETE -KING COUNTY INSPECTION & APPROVAL IS REQUIRED 72 HOURS PRIOR TO CONNECTION -CUSTOMER TO CONTACT CUSTOMER CARE SERVICE (1-888-321-7779) WHEN READY FOR PERMANENT SERVICE OVERHEAD CIRCUIT MAP 2306E076 SCALE: 6" = 1 MILE JOB SITE SPAN SPECIFIC NOTES P01 TO V01: ,167$//581$/-.7¶ ,167$//'%&21'8,7“ &86720(5723$<)25'(',&$7(')$&,/,7,(6“ V01 TO M01: &86720(572,167$//5810&08*73;  ¶ &86720(572,167$//',6&217,18286*5(<6&+ /&21'8,7“ E-Mail: Cell Phone: Project Manager Contact Information: Manager:RUSSELL PAGE (253) 234-6444 RUSSELL.PAGE@PSE.COM 90° 9. 7. 6. 5. 4. 3. 2. 1.All materials to be installed in accordance with Puget Sound Energy's (PSE) standards. Any deviation from this work sketch must be AUTHORIZED by Potelco's Project Manager and NOTED on the Foremans' Copy. All switching arrangements and/or outage arrangements are to be made with the Project Manager at least three (3) working days in advance. Contact the Utilities Underground Location Center (1-800-424-5555) at least 48 hours prior to commencing work to get the underground facilities located. STAKING: The customer will provide all staking (transformer, handhole, trench, grade, lot, pole, sidewalk, etc.). See sketch and details for locations. Equipment locations must be approved by the Project Manager. SITE PREPARATION: The work area will be at or near finished grade, clear of trench spoils or construction materials which would restrict construction and/or equipment access, before work can begin. CLEARANCES: Transformers require a minimum of 6 feet from fire fighting equipment, 10 feet from combustible walls, overhangs, doors, and windows, and a minimum of 5 feet from the back of curb (or guard posts will be required per PSE standards). All conduits and vaults are to be at least 5 feet away from water, storm and sewer lines when paralleling them in the right of way, and at least 1 foot when crossing them. All work is to be done in accordance with local municipal and county permit requirements as applicable. Customer/Developer is responsible to provide, install and maintain all secondary service cables, conduits and crossings from the individual unit's meter base to the designated connection point. EXCAVATION: The customer is to provide all trenching, backfill, vault excavations, compaction and restoration per this sketch and per PSE standards. A minimum protective cover of 36" is required over PSE's primary voltage equipment and 24" is required of PSE's secondary voltage equipment. The customer will provide any and all shoring or they will side slope the trench to 1:1. 8. POWER GENERAL NOTES - RESIDENTIAL PROJECT TOP VIEW Standoff Bracket 15" Min Length Conduit Clamp ConduitField FaceQuadrantClimbing Space Road FaceQuadrantClimbing Space 5 " M i n CLLCDirection of Vehicular TrafficUNDERGROUND CABLE CONDUITS TO THIS QUADRANT CUSTOMER-CONDUIT & RISER LOC. DETAIL SCALE: NONE DEDICATED FACILITIES (105085669) SITE SPAN ADDITIONAL REMARKS LABOR UNITS #FROM TO FOOTAGE -A B 275 DED. CONDUIT 2-36 TOTAL FT=275 Remote Temp Svc 504760102 104293474 VAULT & EQUIPMENT TABLE SITE #GRID # VAULT SIZE & COVER TYPE & SIZE EQUIPMENT IN VAULT PRIMARY BUSHINGS TRANSFORMER ID NUMBERS (COMPANY ID) AS-BUILT INFORMATION LB DC FOREMAN: INCLUDE PHASE TAPPED V01 317996- 167938 36"x42"x38" MP HH Matid: 7662110 37.5KVA PM TRF 120/240 Matid: 6247050 1 1 PRIMARY CABLE & CONDUIT TABLE LOCATION CONDUIT CABLE AS BUILT INFORMATION - FOREMAN COMPLETE FROM TO SIZE (IN)QTY. DESIGN LENGTH (FT) BENDS PULL (LBS) PULL REV (LBS) CABLE SIZE DESIGN LENGTH (FT) PHASE - ID TAG RECORD RECORD PHASE TAPPED & ACTUAL FOOTAGE INSTALLED 90°45°22°11°A B C MANUFACTURER COMPOUND YEAR NOTES CONDUIT CABLE P01 V01 2 1 350'1 1 --145 290 1/0 AL JKT 380'EHM632 - 2" PVC (FT) & BENDS =350'1 1 0 0 1/0 AL JKT TOTAL (FT) =380' Phone & TV Primary Power Cable Direct Buried or in PSE provided Excavated Dirt Pile Final Grade 24" Min 48" Max 18" Backfill for DB 120 Conduit/Direct Buried Cable 4" Min Separation 6" or 12" of sand, 5/8" minus 3" of sand, 5/8" minus, or clean backfill bedding JOINT TRENCH DETAIL 36" Min Cover ROADSIDE Typical To Excavated Dirt Pile (No Rocks over 10" Diameter) or clean backfill shading DB120 Grade Conduit Primary-Direct Buried or DB 120 (NTS) - A 6" layer of sand, 5/8" minus, or clean shading is allowed when excavated native material contains rocks no larger than 8" in diameter. Trench and backfill requirements for primary electric line extension trenches (No PSE gas) - A 12" layer of sand, 5/8" minus, or clean shading is required when excavated native material contains rocks up to 10" in diameter. 4' X 4' WORK PIT & 3/4" CUBIC YARD SAND CUSTOMER SUPPLIED CUSTOMER SUPPLIED 6&+(' /',6&217,1828639&&21'8,7“ INST. 1-RUN 350 UG TPX & 10' OF 4/0 ± 220' CUSTOMER SUPPLIED 4' X 4' WORK PIT CUSTOMER SUPPLIED 1 CUBIC YARD 5/8" CRUSHED ROCK 90°CUSTOMER TO PAY FOR DEDICATED FACILITIES ± 256' 35,0$5<'%&21'8,7“ INST. 1-RUN 1/0 AL JKT ± 380' CUSTOMER SUPPLIED 6' X 6' WORK PIT TOP VIEW SIDE VIEW EXCAVATION: 4-2/3 CUBIC YARDS Rock Crushed 6" 3'-6" 2" 6' 6' 48"42" 36" 38" 42" VAULT & EXCAVATION DETAIL Not to scale 6045.1000 1950 lbs 40T