HomeMy WebLinkAboutP_Design_104293405_V1_170828M01 P01 90° (>36") 1-3" SCH'L 40 CONDUIT, ± 124' ON PRIVATE PROPERTY 3/4 CU. YD. OF SAND 3/4 CU. YD. OF SAND 1-3" SCH'L 80 CONDUIT, ± 124' WITHIN RIGHT-OF-WAY (1) RUN #4/O UG TPX, ± 278' M01 EVA 23 TALBOT RD SCUR R E N T L Y G R A S S / T R E E PROP O S E D S 1 9 8 T H P L EXTE N S I O N "196 4 0 " NEW GAR A G E P01 S 19 9 T H S T 315773 165841 25kVA 120/240v 124' 60'94'"952 2 " "950 0 " "198 1 6 " EXIS T I N G HOM E "198 0 8 " "196 5 3 " "198 0 1 " SITE PLAN N Vicinity Map N/A Owner / Developer Contact Info officeATTN: PETER GUNTER 19808 TALBOT RD S RENTON, WA 98055 PETER GUNTER (206) 795-5917 104293405THIS SKETCH NOT TO BE RELIED UPON FOR EXACT LOCATION OF EXISTING FACILITIES CALL (800) 424-5555 2 BUSINESS DAYS BEFORE YOU DIG For contacts below dial 1-888-CALL PSE (225-5773) HP Svc/MSA HP Main Distribution Superior ORDER#NOTIF# PWR PROJECT PHASE N/AN/A N/AN/A N/AN/A N/AN/A N/AN/A N/AN/A N/AN/A N/AN/A 104293405504520868 CABLE TV PHONE GAS FOREMAN (CHECK BOX WHEN COMPLETED) PSE Equipment LOCKED/SECURED & Work Area left in CLEAN/SAFE Condition. Grid, Cable, and Switch numbers INSTALLED & VERIFIED. Field Changes RED-LINED on As-built. Indicate correct FUSE SIZE on As-built & VERIFY proper PHASE. Foreman's Signature _______________________________________________ Print Name ___________________________________ Date ______________ Material VERIFIED and CHANGES noted on Paperwork. Total PRIMARY Cable noted on As-built. Company ID#'s RECORDED in correct location on As-built. Deviations noted on the As-built and their reason. I certify that the work performed meets PSE's standards and procedures and that all quality requirements are met. PSE No No No Yes Yes Yes No YesDeveloper "Flagging Required" "Outages Required" "Locates Required" SCALE: 1" = 50' ARE TO BE INSTALLED, CROSS SECTION DETAILS OF THE TYPICAL EROSION STRUCTURES, & SPECIAL REQUIREMENTS FOR WORK IN SENSITIVE AREAS.) EROSION & SEDIMENT CONTROL REQUIREMENTS NOTES DETAILING WHERE EROSION OR SEDIMENT CONTROL STRUCTURES (LOCAL JURISDICTIONS MAY HAVE ADDITIONAL REQUIREMENTS INCLUDING 0150.3200 TECHNIQUES FOR TEMPORARY EROSION & SEDIMENT CONTROL EROSION & SEDIMENT CONTROL SHALL BE PER PSE STANDARD PRACTICE & ANY ADDITIONAL LOCAL JURISDICTION REQUIREMENTS. CIRCUIT LOADING TABLE AS OF EXIST. PEAK LOAD EST. NEW LOAD TOTAL CIRCUIT: A PHASE B PHASE C PHASE EVA-23 2017 119 119 116 -1.17 - 119 120.17 116 SCALE: NONE CIRCUIT ONE-LINE DIAGRAM OVERHEAD CIRCUIT MAP SCALE: 6" = 1 MILE UTILITIES CONTACT PHONE# COUNTY 1/4 SEC U-MAP NO (POWER) OP MAP Emer Sect Gas Wk Ctr POWER WK CTR PLAT MAP JOINT FACILITIES ARRANGEMENTS DRAWN BY CHECKED BY APPROVED BY FOREMAN #1 FOREMAN #2 MAPPING INCIDENT MAOP Gas Order Elect Order SCALE PAGE ENGR - POWER ENGR - GAS FUNCTION PROJECT MGR PERMITREAL ESTATE/EASEMENT 2 1 REV# 3 DATE DESCRIPTIONBY CONTACT PHONE NO DATE OH CKT MAP CIRCUIT NOUG CKT MAP D. HONEYSETT 253-245-0883 07/06/17 D. HONEYSETT 253-245-0883 07/06/17 N/A N/A N/A D. BRINKMANN N/A 07/06/17 N/A CITY OF RENTON SHOP NEW PERMENANT UG SERVICE 19808 TALBOT RD S, RENTON, WA 98055 N/A N/A N/A 104293405 AS NOTED 1/1 KING COUNTY N/A N/A CSPCKEIN T22N,R05E,NE SEC 06 N/A N/A 2205E021 2205E036 2205E021 EVA-23 N/A N/A N/A N/A N/A N/A N/A N/A N/A N/A N/A N/A E-Mail: Cell Phone: Project Manager Contact Information: Manager:D. HONEYSETT 253-245-0883 DAVID.HONEYSETT@PSE.COM TV & TEL Electric Service Cable in Conduit 3" Schedule 40 Grey PVC Excavated Dirt Pile Final Grade 24" Min 24" Min to 36" Max Cover Backfill for Conduit Free of rocks larger than 8" in diameter Separation 6" Min in Conduit Schedule 40 White PVC Gas Service Line 32" Typical (Power, Gas, Phone & Cable) Separation 4" Min 12" Min Separation 36" MINIMUM COVER IN RIGHT OF WAY JOINT TRENCH DETAIL Joint Service Line in Conduit (NTS) To Excavated Dirt Pile Backfill for In Conduit - The backfill layer shall be soil that is free from construction debris, glass, sharp rocks, frozen clods, and rocks larger than 8" in diameter. CONDUIT RISER PLACEMENT DETAIL TOP VIEW Not to Scale OVERHEAD CIRCUIT MAP SCALE: 6" = 1 MILE SITE PLAN SCALE: 1" = 50' SITE SPECIFIC NOTES: P01 -EXISTING POLE AND EQUIPMENT TO REMAIN -INSTALL NEW 1-3" RISER ON EXISTING S/O BRACKETS SPAN NOTE: P01 TO M01 -CUSTOMER TO INSTALL NEW 1-3" SCH'L 80 CONDUIT, ±124', WITHIN ROW -CUSTOMER TO INSTALL NEW 1-3" SCH'L 40 CONDUIT, ±124', ON PRIVATE PROPERTY -PSE TO INSTALL 1 RUN #4/0 TPX, ± 278" DEVELOPER & CUSTOMER NOTES: -CUSTOMER IS RESPONSIBLE FOR ALL TRENCHING , SELECT BACKFILL, RESTORATION AND COMPACTION PER PSE STANDARDS #6750.6500. -CUSTOMER NEEDS TO PROVIDE PROOF OF L&I INSPECTION 72 HOURS PRIOR TO CONSTRUCTION -CUSTOMER TO PROVIDE 4'x4'WORK PIT & 3/4 CU. YD. OF SAND @ M01 & P01 -CUSTOMER TO PROVIDE AND INSTALL DISCONTINUOUS 54971-3" SCH'L 80 GRAY &21'8,7“ 3(5&,7<2)5(172125',1$1&(6(&7,219 -CUSTOMER TO PROVIDE AND INSTALL DISCONTINUOUS 1-3" SCH'L 40 GRAY &21'8,7“ -CUSTOMER TO PROVIDE & INSTALL 3/8" NON POLY PULL ROPE ALL TRENCHING WILL REQUIRE AN INSPECTION BY PSE BEFORE FINAL BACKFILL. ALL TRENCH AND L&I INSPECTION MUST BE COMPLETED 72HRS BEFORE CONSTRUCTION. POWER GENERAL NOTES - RESIDENTIAL PROJECT 1.All materials to be installed in accordance with Puget Sound Energy's (PSE) standards. Any deviation from this work sketch must be AUTHORIZED by PSE's Project Manager and NOTED on the Foremans' Copy. 2.All switching arrangements and/or outage arrangements are to be made with the Project Manager at least three (3) working days in advance. 3.Contact the Utilities Underground Location Center (1-800-424-5555) at least 48 hours prior to commencing work to get the underground facilities located. 4.STAKING: The customer will provide all staking (transformer, handhole, trench, grade, lot, pole, sidewalk, etc.). See sketch and details for locations. Equipment locations must be approved by the Project Manager. 5.SITE PREPARATION: The work area will be at or near finished grade, clear of trench spoils or construction materials which would restrict construction and/or equipment access, before work can begin. 6.Roads shall be paved or have a compacted , crushed rock base in place. 7.CLEARANCES: Transformers require a minimum of 6 feet from fire fighting equipment, 10 feet from combustible walls, overhangs, doors, and windows, and a minimum of 5 feet from the back of curb (or guard posts will be required per PSE standards). All conduits and vaults are to be at least 5 feet away from water, storm and sewer lines when paralleling them in the right of way, and at least 1 foot when crossing them. 8.All work is to be done in accordance with local municipal and county permit requirements as applicable. 9.Inclement weather conditions may cause delays in construction times and dates. 10.EXCAVATION: The customer is to provide all trenching, backfill, vault excavations, compaction and restoration per this sketch and per PSE standards. A minimum protective cover of 36" is required over PSE's primary voltage equipment and 24" is required of PSE's secondary voltage equipment. The customer will provide any and all shoring or they will side slope the trench to 1:1. LRC: % V. Drop: % Flicker: Sq. Footage: Panel Size: Heat Type: Est. Demand: 2000 SQ. 200 AMPS GAS 8 KW 65A 2.8% 3.0% CIRCUIT FEED ADDED: 0' 32" Typical 24" Min 24"-36" 24"-36" 4'Top View Electric & Joint Utility Work Pit Dimensions 36" Min Drainage Pipe 12" Minimum Clearance from Gas Service Lines Conduit Depth 24" to 36" Max Regulator Vent Gas Meter Assembly Utility Provided 48" 4'8" Service (Permanent Detail:) Not to Scale Seal Conduit Ends Closed 4'8" 24" Min 36" Typical 3' To Trench Property Line Conduit StakesGas Service Line Conduit 3" Conduit Service Riser Customer Provided Elec. Mtr Base Elec Mtr utility provided Gas Meter Relief Vent Building Wall Elec. Mtr PERMANENT METER DETAIL AT M02 NOT TO SCALE JOB SITE JOB SITE Standoff Bracket 15" Min Length Conduit Clamp Conduit Field Face Quadrant Climbing Space Road Face Quadrant 5" Min ℄ Climbing Space℄ OUTAGE LIST "19816" 2nd AVE S, Kent, WA 98030 "9522" 2nd AVE S, Kent, WA 98030 "9500" 2nd AVE S, Kent, WA 98030 "9507" 2nd AVE S, Kent, WA 98030 "19821" 2nd AVE S, Kent, WA 98030 "19833" 2nd AVE S, Kent, WA 98030 Direction of Vehicular Traffic (Southtound)Utility StuboutsTrench to Building 4' 4'GasTV, TELPowerWork Pit Dimensions Electric and Joint Utility 12" Sand Backfill 3/4 Yard Gas Service Line Conduit Pipes and Wires Utility Installed Conduit Depth Schedule 40 Yellow or White PVC Customer Provided Gas Stub Marker Utility Provided Dig to 12" from the Gas Marker Cover any accidentally exposed gas stubs with 12" of sand. 24" Min to 36" Max Electric Service Cable Conduit 3" Schedule 40 Grey PVC Customer Provided Electric Stub Marker Utility Provided Sand Backfill Requirements: Sand shall be provided on-site by the customer and placed within hand-shoveling distance to the work pit for shading over direct buried facilities. POWE R TV TEL GAS CUSTOMER PROVIDED PROPERTY LINE WORK PIT NOT TO SCALE depth as mainline trench conduit. 3" of Sand Bedding 3" of Sand Shading 36" Min Cover (38" Max)6" Road crossing must be at same Pavement Curb Sidewalk R/W ROAD CROSSING ELEVATION Not to scale 6790.0075