HomeMy WebLinkAboutMFP17004440DEPARTMENT OF COMMUNITY
AND ECONOMIC DEVELOPMENT
Franchise Permit: MFP17004440
IVR Number: 17004440
Permit Informa!on
Permit Name:Puget Sound Energy - Electric
Address/Loca!on:09/05/2017Applica!on Date:0423059186Parcel Number:3410 NE 12TH ST
Permit Type :10/06/2017Issue Date:Franchise
Permit Work Class:10/06/2018Expira!on Date :Minor U&lity
Job Number:105079276Franchise Type :Electric
Descrip!on:install 3" conduit with secondary cable to new handhold on private property to serve 3410
This is a Reapplica&on .
Contacts
Name Address PhoneTypeBilling
ANISH KUMAR
PUGET SOUND ENERGY - ELECTRIC - BILLING
6905 S 228th St
Kent, WA 98032
B: (253) 208-2183Applicant
J.D. Wilson
City of Renton
1055 S Grady Way , 5th Floor
Renton, WA 98057
B: (425) 430-7295Contact
Vicki Henson
Potelco Inc
8001 212th St S
Kent, WA 98032
B: (253) 863-0484Contractor
Business License Number: BL.005109Electrical Contractor : POTELI*344O4
Construc!on Contractor : POTELI*227PL
CITY OF RENTON ROW 1055 S Grady Way
Renton, WA 98057-3232
Owner
ANISH KUMAR
PUGET SOUND ENERGY - ELECTRIC - BILLING
6905 S 228th St
Kent, WA 98032
B: (253) 208-2183Specialized
Billing
X
General Condi!ons & Signature
Permission is hereby given for the work described on this permit according to the conditions hereon and according to the
approved plans and specifications pertaining thereto, subject to compliance with the Ordinance of the City of Renton.
This permit and plans must be posted at the job site at all times.
I hereby certify that no work is to be done except as described above and in approved plans, and that work is to conform to
Renton Trench Restoration and Street Overlay Requirements.
Call (425) 430-7203 or go to: www.MyBuildingPermit.com one working day in advance to schedule an inspections and for ANY
work in the Right of Way.
Call 8 1 1 to locate underground utilities at least two full business days prior to any excavation.
In accordance with RCW 19.122.033(4) the permit holder is required to contact (Williams Northwest Pipeline at 425.868.1010)
(Olympic Pipeline at 206.510.0575)(Puget Sound Energy at 425.457.5816) to request a consultation with the transmission
pipeline company prior to performing any construction or excavation activities. This requirement to consult with the
transmission pipeline company is in addition to the requirement to Call before You Dig as required in RCW 19.122.
(Date)(Signature)
Page 1 of 1THIS PERMIT AND PLANS MUST BE POSTED AT THE JOB SITE AT ALL TIMES
DEPARTMENT OF COMMUNITY
AND ECONOMIC DEVELOPMENT
Page 1 | Published: 3/30/2017
Planning Division | 1055 South Grady Way, 6th Floor | Renton, WA 98057 | 425-430-7200
Email: franchisepermits@rentonwa.gov Website: rentonwa.gov
FRANCHISE PERMIT APPLICATION
Published: 3/30/2017
TO THE APPLICANT: Submit an electronic copy of the plans with the Franchise Permit Application and the
Traffic Control Application to franchisepermits@rentonwa.gov. Permit cost is $360.50. Inspection fee for
trenching more than 60 lineal feet or installation of 6 or more poles will be billed at $60.00 per hour.
Franchise Agency:
Franchise Job Number: Phone:
Contact Name: Email:
Job Site Address: Project Name:
Description of Work:
Please check all that apply:
☐ New Construction ☐ Repair/Relocate ☐ Underground ☐ Overhead ☐ Sidewalk ☐ Street
☐ Open Trench ☐ Bore # of feet:
Contractor Name: Phone:
State Contractors License #: City of Renton Business License #:
“I certify that I am the owner or applicant’s authorized agent and do hereby agree to abide to the terms and conditions set forth under this permit and shall comply with the City of Renton’s Trench Restoration and Street Overlay Requirements. ”
Signature Date
INSPECTIONS SHALL BE REQUESTED 24 HOURS PRIOR TO COMMENCEMENT OF ALL WORK BY CALLING THE
INSPECTION LINE AT 425-430-7203 OR BY GOING TO MYBUILDINGPERMIT.COM
Jobs are required to be called in for job start, re-inspection and project final. Re-inspection fees are billed at $75/hour.
All Pre-Construction meetings shall be scheduled at a maximum of 14 days prior to the job start date.
Plan Review/Development Engineering Date Approved as submitted
Pre-Construction Meeting required
Site Construction Inspector Date Approved with comments or redlines
Camera inspection of utilities required
Development Engineering Manager Date
MFP17004440
Scott Warlick 9/21/2017
Justin Johnson 10-4-2017
CITY OF RENTON
TRAFFIC CONTROL PLAN
PROJECT NAME: PERMIT#
CONSTRUCTION COMPANY: PHONE#:
CONTACT NAME: PHONE#:
ADDRESS: CELL#:
E-MAIL ADDRESS: FAX#:
PROJECT LOCATION: N/E/S/W OF:
WORK TIME: APPROVED BY:
WORK DATE: APPROVAL DATE:
OFFICE COPY T-
CONTRACTOR
DEV. SERVICE, INSPECTION P. MILLER
DEV. SERVICE, PLAN REVIEW B. BANNWARTH
POLICE CHARLES KARLEWICZ
FIRE FIRE MARSHALL FS #13
Permit Holder agrees to all the following:
• Comply with all traffic regulations of the City of Renton and the State of Washington.
• Prepare a traffic control plan and obtain City approval of that plan. That plan shall be implemented for
all street and lane closures, and the plan shall be performed in compliance with the Manual on
Uniform Traffic Control Devices.
• Notify emergency services (253-852-2121) twenty-four (24) hours before any street or lane closures.
• Any lane or street closures not in conformance with the approved traffic control plan and/or without
notification of emergency services may result in receiving a citation for violation of R.C.W. 47.36.200
through 47.36.220, 9A.36.050 Reckless Endangerment, and other applicable State and City codes.
• Indemnify and hold harmless the City of Renton from any and all claims, actions, and judgments,
including all costs of defense and attorney’s fees incurred in defending against same, arising from and
related to implementation of the approved traffic control plans including claims arising from towing of
private vehicles and the acts of the Permit Holder’s agents and employees.
• The City of Renton shall be entitled, in its reasonable discretion, to settle claims prior to suit or
judgment, and in such event shall indemnify and hold harmless the City for any such claims paid,
including the City’s reasonable attorney’s fees and litigation costs incurred resulting from such claim.
• In the event any claim or suit is brought against City within the scope of this Agreement, Permit Holder
will pay for legal counsel chosen by the City to defend against same.
• Flagger and sign placement are subject to revision by the City Inspector on site, if needed to address
traffic or pedestrian safety or travel.
• By my signature herein, I acknowledge all the above requirements.
PRINT NAME: DATE:
SIGNATURE:
Reset FormPrint Form
MFP17004440
Justin Johnson
10-4-2017
SKETCH
I
-- NORTH --
I
NOTES:
• Work Zone Traffic Control shall be in accordance with the Manual on Uniform Traffic Control Devices (MUTCD)
and shown by sketch or reference to WSDOT.
• The plan must be submitted to the City’s PW/Transportation Division for review and/or approval at least three
working days prior to work.
• Approved Temporary Traffic Control Plan must be at the work site during work hours.
• Contractor or entity must call Renton School District (425-204-4455) or any public/private agency to be affected
by a temporary lane or road closure.
• Complete assistance and accommodation shall be provided to all kinds of pedestrian traffic when sidewalk or
walkway is impeded.
• Total road closure lasting more than 24 hours is subject to the approval by the City Council.
• Any vehicle, equipment, barricade, or portable tow-away sign used within the work area must display a
company logo or any legally acceptable sign showing the company name, address, and telephone number at a
conspicuous place on the vehicle or equipment.
In the case of Temporary No Parking Zones, all the following apply in addition to previous:
• Contractor must complete form to show limits of Temporary No Parking Zone identifying barricade locations for
vacate parking or curb lane usage.
• Contractor must post notice of dates and time of Temporary No Parking Zone with at least two signs per block
72 hours in advance of effective date and time.
• The cover sheet of this Traffic Control Plan form must be attached to each Temporary No Parking Sign on the
project site.
• Temporary traffic control devices must be removed immediately when work is done or no construction activities
are going on. If deemed abandoned, City crews will remove and store them at the City’s maintenance shop
(3555 NE 2nd Street).
PROJECT
PROJECT
LOCATION
TRAFFIC FLOW
PERM LANE MARKINGS
TAPERS / TANGENTS
PROTECTIVE VEHICLE
W/BEACON
TRUCK-MOUNTED
ATTENTUATOR
PORTABLE TRAFFIC
SIGNAL
SLOW
VMS12
LEGEND
FLAGGER
OFFICER
SURVEYORS
WORK SPACE
UTILITY WORK
CONSTRUCTION
DEVICES
SIGNS
BARRICADES
ARROW BOARD
ARROW MODE
ARROW BOARD
CAUTION MODE
PCMS
/ VMS
TEMPORARY TRAFFIC CONTROL PLAN
Not Drawn to Scale
This sketch not to be relied upon for exact location of utilities.
CALL (800) 424-5555 TWO BUSINESS DAYS BEFORE YOU DIG
PERMIT
Yes No
Traffic Control Supervisor(TCS) X
Flaggers/Spotters X
Uniformed Officer X
DRAWING NOT
TO SCALE
Drawn by: D Sandall - WA TCS Certificate # 8957, OR TCS Certificate # 5107
425-923-0010
10/22/2015
1 of 1
City of Renton
WORK HOURS
LANE WIDTH
POSTED SPEED
MERGE TAPER (L)
BUFFER
SIGN SPACING
DEVICES TAPERS
DEVICES TANGENT
10-20 ft
11ft
X
40FT
7am to 5pm
+/-200ft
155ft
100ft*
Robert Baker-Potelco
101075104
robert.baker@pse.com
Robert Webster-PSE
Robert.Webster@pse.com
101094248
James Vigenjames.vigen@pse.com101095266
Betty Frank-PSE
betty.frank@pse.com
11182019
Work from P01 to M01
Notes:
1. All signs and spacing must conform to the City of Renton, WSDOT and the MUTCD.
2.All signs are 48”x48” B/O unless otherwise specified.
3.Channeling devices are 28” cones with retro reflective banding.
4. Notify City , County or WSDOT authorities 48 to 72 hours in advance of work if required.
“K&D Services, Inc., as the preparer of this traffic control plan makes no
representation as to its general adequacy or being approved for implementation.
Approval must come from the Traffic Engineer or other public official having statutory
enforcement authority in the jurisdiction. Utilization and implementation of this plan
shall be as a result of that approval. Ref: MUTCD 2009 6A-01(10).”
Samantha Chipps-Freeman-Quanta
Samantha.Chipps-Freeman@pse.com
101092470
Hong Nguyen-Quanta
hong.nguyen@pse.com
105078446
Michael Judy-PSE
mike.judy@pse.com
105077588
Boris Sidorov-PSE
Boris.Sidorov@pse.com
101094821
Vincent Rabon -PSE
vincent.rabon@pse.com
105076373
Val Buzunovval.buzunov@pse.com105078786 Lee Brown101094384lee.brown@pse.com
Luke Neely
like.neely@pse.com
101094655
Tom Kerfonta
tom.kerfonta@pse.com
101087984
Brigitte Burleson
101091924
brigitte.burleson@pse.com
3410 NE 12th St
Carl Buher
carl.Buher@pse.com
101074754
Nick CoulsonNick.Coulson@pse.com111022724
Hong Nguyen
hong.nguyen@pse.com
105077495
Chun Ho
Chun.Ho@pse.com
101092096
Victor A Ibarra
victor.ibarra@pse.com
105076667 R1
Kelly O’Brien
Kelly.O’Brien@pse.com
186045114
David Goodaledavid.goodale@pse.com101095670 Guy RiderGuy.Rider@pse.com101093487
Trina Gallaher
Trina.Gallaher@pse.com
594103826
Leslie Regier
Leslie.Regier@pse.com
101095356
Devandra Kumar-Quanta
devandra.kumar@pse.com
105077846
Jake Helgestadjake.helgestad@pse.com101093835
Asta Bitinas
105078492
Asta.Bitinas@pse.com
Kelley O’BrienKelley.O’Brien@pse.com571012205
Bradley Elkin
bradley.elkin@pse.com
105078725
Jessica Reibman
Jessica.Reibman@pse.com
101095143
Jeremy TuntlandJeremy.Tuntland@pse.com111022798Robert Gallaherrobert.gallaher@pse.com101095293Carolyn Soetengacarolyn.soetenga@pse.com101094976
Jeremy Boland
Jeremy.Boland@pse.com
101091141
Fabian Gomez-Aerotek
Fabian.Gomez@pse.com
105075581
Jessica Reibman
Jessica.Reibman@pse.com
105079276
Vasiliy Trofimenko
Vasiliy.Trofimenko@pse.com
105051741
Carl McDonald
carl.mcdonald@pse.com
105077968
25mph
Ernie Garza
Ernie.Garza@pse.com
111020530
Adam Armstrong
Adam.Armstrong@pse.com
101095786
Roberta Marta
roberta.marta@pse.com
101095575
Libby RogerLibby.Roger@pse.com5007447/186570863
Randy Blackie-Aerotek
randy.blackie@pse.com
105078603-107050775
Dianne AlexanderDianne.Alexander@pse.com104273556
Barbara Haddox
Barbara.Haddox@pse.com
186569559
*Flagger Taper
MFP17004440
HIG
13
6X6 WORK PIT
4X4 WORK PIT
5818*73/;
6&+
/&21'8,7
SITE PLAN
Owner / Developer Contact Info
officeATTN:
CITY OF RENTON
3555 NE 2ND ST
RENTON, WA 98056
GEORGE STAHL (425)430-7400 105079276THIS SKETCH NOT TO BE RELIED UPON FOR EXACT LOCATION OF EXISTING FACILITIES
CALL (800) 424-5555
2 BUSINESS DAYS BEFORE YOU DIG
For contacts below dial 1-888-CALL PSE (225-5773)
SITE SPECIFIC NOTES
OVERHEAD CIRCUIT MAP
SCALE: 6" = 1 MILE
SCALE: NONE
CONDUIT CIRCUIT ONE-LINE DIAGRAM
CIRCUIT FEET ADDED: 0'
ARE TO BE INSTALLED, CROSS SECTION DETAILS OF THE TYPICAL EROSION
STRUCTURES, & SPECIAL REQUIREMENTS FOR WORK IN SENSITIVE AREAS.)
EROSION & SEDIMENT CONTROL REQUIREMENTS
NOTES DETAILING WHERE EROSION OR SEDIMENT CONTROL STRUCTURES
(LOCAL JURISDICTIONS MAY HAVE ADDITIONAL REQUIREMENTS INCLUDING
0150.3200 TECHNIQUES FOR TEMPORARY EROSION & SEDIMENT CONTROL
EROSION & SEDIMENT CONTROL SHALL BE PER PSE STANDARD PRACTICE
& ANY ADDITIONAL LOCAL JURISDICTION REQUIREMENTS.
FOREMAN (CHECK BOX WHEN COMPLETED)
PSE Equipment LOCKED/SECURED & Work Area left in CLEAN/SAFE Condition.
Grid, Cable, and Switch numbers INSTALLED & VERIFIED.
Field Changes RED-LINED on As-built.
Indicate correct FUSE SIZE on As-built & VERIFY proper PHASE.
Foreman's Signature _______________________________________________
Print Name ___________________________________ Date ______________
Material VERIFIED and CHANGES noted on Paperwork.
Total PRIMARY Cable noted on As-built.
Company ID#'s RECORDED in correct location on As-built.
Deviations noted on the As-built and their reason.
I certify that the work performed meets PSE's standards and procedures
and that all quality requirements are met.
GAS
PHONE
CABLE TV
502089838 105079276
N/A N/A
N/A N/A
N/A N/A
502382465 587025070
N/A 586022668
N/A N/A
N/A N/A
N/A N/A
PROJECT PHASE
PWR
NOTIF#ORDER#
Superior
Perm. Service
Relocation
Removal
Temporary
Job Order
Distribution
HP Main
HP Svc/MSA
DESIGNED BY
UTILITIES
CONTACT
PHONE#
COUNTY
1/4 SEC
U-MAP NO (POWER)
OP MAP
Emer Sect Gas Wk Ctr POWER WK CTR
PLAT MAP
JOINT FACILITIES ARRANGEMENTS
DRAWN BY
CHECKED BY
APPROVED BY
FOREMAN #1
FOREMAN #2
MAPPING
INCIDENT MAOP
Gas Order Elect Order
SCALE PAGE
ENGR - POWER
ENGR - GAS
FUNCTION
PROJECT MGR
PERMITREAL ESTATE/EASEMENT
2
1
REV#
3
DATE DESCRIPTIONBY
CONTACT PHONE NO DATE
OH CKT MAP CIRCUIT NOUG CKT MAP
VAL BUZUNOV 425-457-9938 10/20/15
VAL BUZUNOV 425-457-9938 10/20/15
N/A N/A N/A
J. REIBMAN 2534376798 10/20/15
ROW REVIEW RENTON
CITY OF RENTON
N/A
3410 NE 12TH ST, RENTON, WA 98056
PSE
N/A N/A
N/A 105079276
AS NOTED 1/1
KING N/A N/A CSPSKEIN
T23N, R05E, SE SEC 16 N/A N/A
2305E016 2305E040 2305E016 HIG-13
N/A
N/A
N/A
N/A
N/A
N/A
N/A
N/A
N/A
N/A
N/A
N/A
POWER GENERAL NOTES - COMMERCIAL PROJECT
8.
EXCAVATION: The customer is to provide all trenching, backfill, vault excavations, compaction and
restoration per this sketch and per PSE standards. A minimum protective cover of 36" is required over
PSE's primary voltage equipment and 24" is required of PSE's secondary voltage equipment. The customer
will provide any and all shoring or they will side slope the trench to 1:1.
All materials to be installed in accordance with Puget Sound Energy's (PSE) standards. Any deviation from
this work sketch must be AUTHORIZED by PSE's Project Manager and NOTED on the Foremans' Copy.
All switching arrangements and/or outage arrangements are to be made with the Project Manager at least
three (3) working days in advance.
Contact the Utilities Underground Location Center (1-800-424-5555) at least 48 hours prior to commencing
work to get the underground facilities located.
STAKING: The customer will provide all staking (transformer, handhole, trench, grade, lot, pole, sidewalk,
etc.). See sketch and details for locations. Equipment locations must be approved by the Project Manager.
SITE PREPARATION: The work area will be at or near finished grade, clear of trench spoils or construction
materials which would restrict construction and/or equipment access, before work can begin.
Roads shall be paved or have a compacted , crushed rock base in place.
CLEARANCES: Transformers require a minimum of 6 feet from fire fighting equipment, 10 feet from
combustible walls, overhangs, doors, and windows, and a minimum of 5 feet from the back of curb (or guard
posts will be required per PSE standards). All conduits and vaults are to be at least 5 feet away from water,
storm and sewer lines when paralleling them in the right of way, and at least 1 foot when crossing them.
All work is to be done in accordance with local municipal and county permit requirements as applicable.
Customer/Developer is responsible to provide, install and maintain all secondary service cables, conduits
and crossings from the individual unit's meter base to the designated connection point.
Inclement weather conditions may cause delays in construction times and dates.
1.
2.
3.
4.
5.
6.
7.
9.
11.
10.
PSE
No
No
No
Yes
Yes
Yes
No
YesDeveloper
"Flagging Required"
"Outages Required"
"Locates Required"
E-Mail:
Cell Phone:
Project Manager Contact Information:
Manager:VAL BUZUNOV
425-457-9938
val.buzunov@pse.com
N
Vicinity Map
N/A
LRC:
% V. Drop:
% Flicker:
Sq. Footage:
Panel Size:
Heat Type:
Est. Demand:
N/A
N/A
N/A
50
100
3.6
1.9
SCALE: 1"=50'
TRENCH DETAIL
Electric Service Cable in Conduit (NTS)
Electric Service Cable in Conduit
Excavated Dirt Pile
Final Grade
24" Min
24" Min
to
36" Max
Cover
12" Typical
(6" Min)
Backfill for Conduit
Free of rocks
larger than 8"
in diameter)
36" MINIMUM COVER
IN RIGHT OF WAY
To Excavated Dirt Pile
3" Schedule 80 Grey PVC
Backfill for In Conduit - The backfill layer shall be soil that is free from construction debris,
glass, sharp rocks, frozen clods, and rocks larger than 8 " in diameter.
SIDE VIEW
15"
23-1/4"32-3/4"
2"
Captive L-Bolt
Lock Cover, 10 lbs
24"
Approx
Approx
13"
Customer's
service
conductors
4-3/4" X 4-3/4"
KNOCKOUT IN 2 PLACES
Conductors enter from
beneath and shall be
folded back with handhole
Set handhole flush
to final grade
Captive L-Bolt
Lock Cover
SINGLE PHASE SECONDARY HANDHOLE
Not to scale 6050.2000
Standoff Bracket
15" Min Length
Conduit Clamp
Conduit Field Face
Quadrant
Climbing
Space
Road Face
Quadrant
Climbing
Space
5" Min
CL LCDirection of Vehicular Traffic
RISER PLACEMENT DETAIL
TOP VIEW
Not to Scale
P01 318643-166904
-INSTALL 1-3 CONDUIT RISER
H01
-INSTALL NEW 13"x24" F/G HH.
-INSTALL NEW 3 of 4-POS FARGOS.
-CONNECT 2 RUNS OF CUSTOMER OWNED 3/0 SVC.
SPAN NOTES
P01 TO H01
-INSTALL 10' OF 1-3" SCH'L 80 CONDUIT.
,167$//8*73;
SECONDARY UNDERGROUND &
MFP17004440