HomeMy WebLinkAboutP_Design_104295722_V1_170908JOB SITE JOB SITE NEW LOT 2 EXISTING "1909" 60' 1916 1900 1824 1818 1806 4' X 4' WORK PIT 6' X 4' WORK PIT 3/4 YARD OF SAND -CUSTOMER TO INSTALL ±235' OF 1-3" SCH'L 80 GREY PVC CONDUIT -PSE TO INSTALL ±245' OF(1) 350KCMIL SEC UG TPLX 95' 125' 15'90° POWER GENERAL NOTES - RESIDENTIAL PROJECT ARE TO BE INSTALLED, CROSS SECTION DETAILS OF THE TYPICAL EROSION STRUCTURES, & SPECIAL REQUIREMENTS FOR WORK IN SENSITIVE AREAS.) EROSION & SEDIMENT CONTROL REQUIREMENTS NOTES DETAILING WHERE EROSION OR SEDIMENT CONTROL STRUCTURES (LOCAL JURISDICTIONS MAY HAVE ADDITIONAL REQUIREMENTS INCLUDING 0150.3200 TECHNIQUES FOR TEMPORARY EROSION & SEDIMENT CONTROL EROSION & SEDIMENT CONTROL SHALL BE PER PSE STANDARD PRACTICE & ANY ADDITIONAL LOCAL JURISDICTION REQUIREMENTS. 10. 7. 6. 5. 4. 3. 2. 1.All materials to be installed in accordance with Puget Sound Energy's (PSE) standards. Any deviation from this work sketch must be AUTHORIZED by PSE's Project Manager and NOTED on the Foremans' Copy. All switching arrangements and/or outage arrangements are to be made with the Project Manager at least three (3) working days in advance. Contact the Utilities Underground Location Center (1-800-424-5555) at least 48 hours prior to commencing work to get the underground facilities located. STAKING: The customer will provide all staking (transformer, handhole, trench, grade, lot, pole, sidewalk, etc.). See sketch and details for locations. Equipment locations must be approved by the Project Manager. SITE PREPARATION: The work area will be at or near finished grade, clear of trench spoils or construction materials which would restrict construction and/or equipment access, before work can begin. Roads shall be paved or have a compacted , crushed rock base in place. CLEARANCES: Transformers require a minimum of 6 feet from fire fighting equipment, 10 feet from combustible walls, overhangs, doors, and windows, and a minimum of 5 feet from the back of curb (or guard posts will be required per PSE standards). All conduits and vaults are to be at least 5 feet away from water, storm and sewer lines when paralleling them in the right of way, and at least 1 foot when crossing them. All work is to be done in accordance with local municipal and county permit requirements as applicable. Inclement weather conditions may cause delays in construction times and dates. EXCAVATION: The customer is to provide all trenching, backfill, vault excavations, compaction and restoration per this sketch and per PSE standards. A minimum protective cover of 36" is required over PSE's primary voltage equipment and 24" is required of PSE's secondary voltage equipment. The customer will provide any and all shoring or they will side slope the trench to 1:1. 8. 9. UTILITIES CONTACT PHONE# COUNTY 1/4 SEC U-MAP NO (POWER) OP MAP Emer Sect Gas Wk Ctr POWER WK CTR PLAT MAP JOINT FACILITIES ARRANGEMENTS DRAWN BY CHECKED BY APPROVED BY FOREMAN #1 FOREMAN #2 MAPPING INCIDENT MAOP Gas Order Elect Order SCALE PAGE ENGR - POWER ENGR - GAS FUNCTION PROJECT MGR PERMITREAL ESTATE/EASEMENT 2 1 REV# 3 DATE DESCRIPTIONBY CONTACT PHONE NO DATE OH CKT MAP CIRCUIT NOUG CKT MAP RUSSELL PAGE 253-245-0192 8/31/17 RUSSELL PAGE 253-245-0192 8/31/17 N/A N/A N/A TIN NGUYEN 253-437-6703 8/31/17 EASEMENT REQUIRED RENTON DYLAN SHORT PLAT REPLACE B/O HH & INSTALL UG RESIDENTIAL SVC 1909 JONES AVE NE, RENTON WA 98056 N/A N/A N/A 104295722 N/A 1/1 KING N/A N/A CSPSKEIN T23N, R05E, SEC 05 SW N/A N/A 2305E019 2305E040 2305E019 HIG-15 N/A N/A N/A N/A N/A N/A N/A N/A N/A N/A N/A N/A Owner / Developer Contact Info officeATTN: KEN NEAULT PO BOX 2230 ISSAQUAH, WA 98027 KEN NEAULT 206-391-0370E-Mail: Cell Phone: Project Manager Contact Information: Manager:RUSSELL PAGE 253-245-0192 RUSSELL.PAGE@PSE.COM THIS SKETCH NOT TO BE RELIED UPON FOR EXACT LOCATION OF EXISTING FACILITIES CALL 811 TWO BUSINESS DAYS BEFORE YOU DIG For contacts below dial 1-888-CALL PSE (225-5773) N Vicinity Map N/A 104295722FOREMAN (CHECK BOX WHEN COMPLETED) PSE Equipment LOCKED/SECURED & Work Area left in CLEAN/SAFE Condition. Grid, Cable, and Switch numbers INSTALLED & VERIFIED. Field Changes RED-LINED on As-built. Indicate correct FUSE SIZE on As-built & VERIFY proper PHASE. Foreman's Signature _______________________________________________ Print Name ___________________________________ Date ______________ Material VERIFIED and CHANGES noted on Paperwork. Total PRIMARY Cable noted on As-built. Company ID#'s RECORDED in correct location on As-built. Deviations noted on the As-built and their reason. I certify that the work performed meets PSE's standards and procedures and that all quality requirements are met. GAS PHONE CABLE TV PROJECT PHASE PWR NOTIF#ORDER# Superior 104295722504821111 101107518 108102662 PSE No No No Yes Yes Yes No YesDeveloper "Flagging Required" "Outages Required" "Locates Required" SCALE: 6" = 1 MILE OVERHEAD CIRCUIT MAP SITE PLAN SCALE: 1" = 50' CIRCUIT LOADING TABLE AS OF EXIST. PEAK LOAD EST. NEW LOAD TOTAL CIRCUIT: A PHASE B PHASE C PHASE HIG-15 2017 347 78 161 0 1.61 0 347 79.61 161 SITE SPECIFIC NOTES P01 GRID# 318862-166343: -EXISTING POLE AND RISER TO REMAIN HH1: -REPLACE EXISTING B/O HANDHOLE W/ NEW 17" X 30" HANDHOLE -INSTALL 3-6 POSITION FARGO BARS -TRANSFER NEW AND EXISTING SERVICES M01: -INSTALL 1-320AMP METER SPAN SPECIFIC NOTES P01-HH1: -PSE TO USE EXISTING FEED FROM P01 TO HH1 HH1-M01: -CUSTOMER TO INST ±235' OF (1)-3" SCH'L 80 GREY PVC CONDUIT. -PSE TO INSTALL ±245' (1) OF 350KCMIL UG TPLX. CUSTOMER DEVELOPMENT NOTES CUSTOMER IS RESPONSIBLE FOR ALL TRENCHING, SELECT BACKFILL, COMPACTION & RESTORATION PER PUGET SOUND ENERGY STANDARDS.#6750.6500 **DEVELOPER NEEDS TO FOLLOW ALL TRENCH DETAILS ON SELECT BACKFILL** -CUSTOMER IS REQUIRED TO PROVIDE A 6' X 4' WORK PIT AT P01 & HH1. -CUSTOMER IS REQUIRED TO PROVIDE A 4' X 4' WORK PIT & 3/4 YARD OF SAND AT M01. -CUSTOMER TO INSTALL “ OF 1-3" SCH'L 80 GREY PVC CONDUIT FROM HH1-M01. -CUSTOMER IS REQUIRED TO PROVIDE AND INSTALL A 3/8" NON-POLY PULL ROPE IN ALL CONDUITS. -CUSTOMER IS REQUIRED TO INSTALL METER BASE ON FRONT 1/3 OF BUILDING. ALL TRENCHING WILL REQUIRE AN INSPECTION BY PSE BEFORE FINAL BACKFILL ALL TRENCH AND L&I INSPECTION MUST BE COMPLETED 72HRS BEFORE CONSTRUCTION CIRCUIT ONE-LINE DIAGRAM SCALE: NONE LRC: % V. Drop: % Flicker: Sq. Footage: Panel Size: Heat Type: Est. Demand: 3850 SQ. 320 AMPS GAS 11 KW 140 A 1.5% 3.1% CIRCUIT FEET ADDED: 0' Email: kenco1@hotmail.com TV & TEL Electric Service Cable in Conduit 3" Schedule 80 Grey PVC Excavated Dirt Pile Final Grade 24" Min 24" Min to 36" Max Cover Separation 12" Min 20" Min JOINT TRENCH DETAIL Electric Service Cable in Conduit (NTS) To Excavated Dirt Pile 36" MINIMUM COVER IN RIGHT OF WAY Backfill for In Conduit - The backfill layer shall be soil that is free from construction debris, glass, sharp rocks, frozen clods, and rocks larger than 8" in diameter. Backfill for Conduit Free of rocks larger than 8" in diameter) 32" Typical 24" Min 24"-36" 24"-36" 4'Top View Electric & Joint Utility Work Pit Dimensions 36" Min Drainage Pipe 12" Minimum Clearance from Gas Service Lines Conduit Depth 24" to 36" Max Regulator Vent Gas Meter Assembly Utility Provided 48" 4'8" Service (Permanent Detail:) Not to Scale Seal Conduit Ends Closed 4'8" 24" Min 36" Typical 3' To Trench Property Line Conduit Stakes Customer Provided 3" Schedule 80 Grey PVC Power Cable Conduit Customer Provided Gas Service Line Conduit Sch 40 White PVC Customer Provided 3" Conduit Service Riser Customer Provided Elec. Mtr Base Elec Mtr utility provided Gas Meter Relief Vent Building Wall Elec. Mtr PERMANENT METER DETAIL AT M01 SCALE: NONE SECONDARY CABLE & CONDUIT TABLE LOCATION CONDUIT SECONDARY CABLE ASBUILT INFORMATION SIZE Qty LENGTH Design (ft) BENDS PULL PULL Cable LENGTH Design (ft) Please Record Foreman - Complete FROM TO (in)90°45°22°11°(lbs) Rev (lbs)Size Manufacturer Compound Year Actual Amount Installed (Conduit & Cable) HH1 M01 3 1 235 2 307.3 285.2 350KCMIL 235 OUTAGE LIST "1901" JONES AVE NE, RENTON WA 98056 "1900" JONES AVE NE, RENTON WA 98056 "1824" JONES AVE NE, RENTON WA 98056 "1909" JONES AVE NE, RENTON WA 98056 Customer's service conductors27-1/4" 18" Captive L-Bolt Lock Cover, 10 lbs 40-1/2" Conductors enter from beneath and shall be folded back with handhole SIDE VIEW 2" 30" Approx Approx 17" TOP VIEW 5'-6" 4'-5" SINGLE PHASE SECONDARY HANDHOLE AT HH1 SCALE: NONE 6050.2000 EROSION & SEDIMENT CONTROL PLAN SCALE: NONE