Loading...
HomeMy WebLinkAboutP_Work_Sketch_186577511_V1_170915NEW AØ - EHG617 NEW BØ - EHG618 NEW CØ - EHG619 NEW AØ - EHG617 NEW BØ - EHG618 NEW CØ - EHG619 318194-166223 485 318258-166232 318194-166192 GAS PHONE CABLE TV N/A N/A N/A N/A N/A N/A N/A N/A N/A N/A N/A N/A N/A N/A PROJECT PHASE PWR NOTIF#ORDER# Superior Perm. Service Relocation Removal TUT Retirement Job Order Distribution HP Main HP Svc/MSA PSE No No No Yes Yes Yes No YesDeveloper "Flagging Required" "Outages Required" "Locates Required" X X X X X X X X THIS SKETCH NOT TO BE RELIED UPON FOR EXACT LOCATION OF EXISTING FACILITIES CALL (800) 424-5555 2 BUSINESS DAYS BEFORE YOU DIG For contacts below dial 1-888-CALL PSE (225-5773)186577511Owner / Developer Contact Info officeATTN: N Vicinity Map NOT TO SCALE FOREMAN (CHECK BOX WHEN COMPLETED) PSE Equipment LOCKED/SECURED & Work Area left in CLEAN/SAFE Condition. Grid, Cable, and Switch numbers INSTALLED & VERIFIED. Field Changes RED-LINED on As-built. Indicate correct FUSE SIZE on As-built & VERIFY proper PHASE. Foreman's Signature _______________________________________________ Print Name ___________________________________ Date ______________ Material VERIFIED and CHANGES noted on Paperwork. Total PRIMARY Cable noted on As-built. Company ID#'s RECORDED in correct location on As-built. Correct QC Checklist(s) reviewed. Deviations noted on the As-built and their reason. I certify that the work performed meets PSE's standards and procedures and that all quality requirements are met. DESIGNED BY UTILITIES CONTACT PHONE# COUNTY 1/4 SEC U-MAP NO (POWER) OP MAP Emer Sect Gas Wk Ctr POWER WK CTR PLAT MAP JOINT FACILITIES ARRANGEMENTS DRAWN BY CHECKED BY APPROVED BY FOREMAN #1 FOREMAN #2 MAPPING INCIDENT MAOP Gas Order Elect Order SCALE PAGE ENGR - POWER ENGR - GAS FUNCTION PROJECT MGR PERMITREAL ESTATE/EASEMENT 2 1 REV# 3 DATE DESCRIPTIONBY CONTACT PHONE NO DATE OH CKT MAP CIRCUIT NOUG CKT MAP D. MARTIN 425-449-7514 09/07/17 S. FOX 714-893-2405 09/07/17 L. ORTIZ 714-893-2405 09/07/17 N/A RENTON - EMERGENCY PCR-13 / DAMAGED CONDUIT REPL DAMAGED CONDUIT AND FEEDER CABLE 485 GARDEN AVE N, RENTON, WA 98057 ASPLUNDH CONSTRUCTION CORP. O-392579 186577511 AS NOTED 1/1 KING FAC-SVC SW 8-23N-05E 2305E031 2305E040 PCR-13 2305E031 UNDERGROUND CIRCUIT MAP SCALE: 1" = 50' MAP#: 2305E031NW 11330209 186577511 SITE MAP SCALE: 1" = 50' E-Mail: Cell Phone: Project Manager Contact Information: Manager:DENNIS MARTIN 425-736-8880 DENNIS.MARTIN@PSE.COM THOMAS GUIDE 656-D1 PRIMARY CABLE REMOVAL TABLE LOCATION PRIMARY CABLE ASBUILT INFORMATION Cable LENGTH Design (ft) Cable Numbers Please Record Foreman - Complete FROM TO Size A B C Manufacturer Year Actual Amount Installed (Conduit & Cable) V01 V02 750 735 53947 53948 53949 CIRCUIT FEET ADDED: NONE SITE SPECIFIC NOTES V01 - V02 -REPLACE DAMAGED 3Ø 750MCM CABLE & REPAIR DAMAGED CONDUIT V01 (318258-166232) -REPLACE (3) HAMMERHEAD SPLICES W/ STRAIGHT SPLICES (SPL750) PER STD 6041.2000 -INSTALL CABLE TAGS EGH617, 18, 19 V02 (318194-166223) -REPLACE (3) HAMMERHEAD SPLICES W/ STRAIGHT SPLICES (SPL750) PER STD 6041.2000 -INSTALL CABLE TAGS EGH617, 18, 19 V03 (318194-166192) -INSTALL CABLE TAGS EGH617, 18, 19 N/A N/A FOREMAN PLEASE FILL IN YEAR MANUFACT: CABLE #: MANUFACTURER: LENGTH: EHG617, 18, 19 750MCM STRAIGHT SPLICE PER STD. 6042.2000 PRIMARY CABLE TABLE - INSTALL LOCATION CABLE ASBUILT INFORMATION - FOREMAN COMPLETE FROM TO QT Y. BENDS PULL (LBS) PULL REV (LBS) CABLE SIZE DESIGN LENGTH (FT) PHASE - ID TAG RECORD RECORD PHASE TAPPED & ACTUAL FOOTAGE INSTALLED 90°45°22°11°A B C MANUFACTURER COMPOUND YEAR NOTES CABLE V01 V02 1 1 2 750 735 EHG617 EHG618 EHG619 TOTAL