25kVA 120/240v
MONSTER RD SW317368-165207
X831
317364-165224
336.4 MCMACSRCBA1400#CELLJACK
SON
P
L
SW
(
P
V
T
)
"1400"
WORK
ZONE
WORK
ZONEMONS
T
ER
RD
SW
J
AC
K
SON
P
L
SW
SW 1
6
T
H
S
T
SITE PLAN
Owner / Developer Contact Info
officeATTN:
Verizon Wireless
PO BOX 2375
Spokane, WA 99210-2375
RyanHarmon (425) 999-2323
SITE SPECIFIC NOTES
OVERHEAD CIRCUIT MAP
SCALE: 6" = 1 MILE
ARE TO BE INSTALLED, CROSS SECTION DETAILS OF THE TYPICAL EROSION
STRUCTURES, & SPECIAL REQUIREMENTS FOR WORK IN SENSITIVE AREAS.)
EROSION & SEDIMENT CONTROL REQUIREMENTS
NOTES DETAILING WHERE EROSION OR SEDIMENT CONTROL STRUCTURES
(LOCAL JURISDICTIONS MAY HAVE ADDITIONAL REQUIREMENTS INCLUDING
0150.3200 TECHNIQUES FOR TEMPORARY EROSION & SEDIMENT CONTROL
EROSION & SEDIMENT CONTROL SHALL BE PER PSE STANDARD PRACTICE
& ANY ADDITIONAL LOCAL JURISDICTION REQUIREMENTS.
FOREMAN (CHECK BOX WHEN COMPLETED)
PSE Equipment LOCKED/SECURED & Work Area left in CLEAN/SAFE Condition.
Grid, Cable, and Switch numbers INSTALLED & VERIFIED.
Field Changes RED-LINED on As-built.
Indicate correct FUSE SIZE on As-built & VERIFY proper PHASE.
Foreman's Signature _______________________________________________
Print Name ___________________________________ Date ______________
Material VERIFIED and CHANGES noted on Paperwork.
Total PRIMARY Cable noted on As-built.
Company ID#'s RECORDED in correct location on As-built.
Deviations noted on the As-built and their reason.
I certify that the work performed meets PSE's standards and procedures
and that all quality requirements are met.
CIRCUIT LOADING TABLE
AS OF
EXIST. PEAK LOAD
EST. NEW LOAD
TOTAL
CIRCUIT:
A PHASE B PHASE C PHASE
RJN-11
6/13/17
75 72 68
--3.1 4.90
75 69.9 72.9
GAS
PHONE
CABLE TV
504868002
N/A 101107585
N/A 108102598
N/A 583057686
N/A 593187732
504924568 104295632
N/A
N/A
N/A N/A
PROJECT PHASE
PWR
NOTIF#ORDER#
Superior
Pole Repl
Pole
Removal
Temporary
Job Order
Distribution
HP Svc/MSA
SCALE: 6" = 1 MILE
SECONDARY CABLE & CONDUIT DIAGRAM
POWER GENERAL NOTES - COMMERCIAL PROJECT
8.
EXCAVATION: The customer is to provide all trenching, backfill, vault excavations, compaction and
restoration per this sketch and per PSE standards. A minimum protective cover of 36" is required over
PSE's primary voltage equipment and 24" is required of PSE's secondary voltage equipment. The customer
will provide any and all shoring or they will side slope the trench to 1:1.
All materials to be installed in accordance with Puget Sound Energy's (PSE) standards. Any deviation from
this work sketch must be AUTHORIZED by PSE's Project Manager and NOTED on the Foremans' Copy.
All switching arrangements and/or outage arrangements are to be made with the Project Manager at least
three (3) working days in advance.
Contact the Utilities Underground Location Center (1-800-424-5555) at least 48 hours prior to commencing
work to get the underground facilities located.
STAKING: The customer will provide all staking (transformer, handhole, trench, grade, lot, pole, sidewalk,
etc.). See sketch and details for locations. Equipment locations must be approved by the Project Manager.
SITE PREPARATION: The work area will be at or near finished grade, clear of trench spoils or construction
materials which would restrict construction and/or equipment access, before work can begin.
Roads shall be paved or have a compacted , crushed rock base in place.
CLEARANCES: Transformers require a minimum of 6 feet from fire fighting equipment, 10 feet from
combustible walls, overhangs, doors, and windows, and a minimum of 5 feet from the back of curb (or guard
posts will be required per PSE standards). All conduits and vaults are to be at least 5 feet away from water,
storm and sewer lines when paralleling them in the right of way, and at least 1 foot when crossing them.
All work is to be done in accordance with local municipal and county permit requirements as applicable.
Customer/Developer is responsible to provide, install and maintain all secondary service cables, conduits
and crossings from the individual unit's meter base to the designated connection point.
Inclement weather conditions may cause delays in construction times and dates.
1.
2.
3.
4.
5.
6.
7.
9.
11.
10.
PSE
No
No
No
Yes
Yes
Yes
No
YesDeveloper
"Flagging Required"
"Outages Required"
"Locates Required"
X
X
XX
E-Mail:
Cell Phone:
Project Manager Contact Information:
Manager:Val Buzunov
(426) 457-9938
VAL.BUZUNOV@PSE.COM
N
Vicinity Map
N/A
SCALE: 1" = 50'105086306THIS SKETCH NOT TO BE RELIED UPON FOR EXACT LOCATION OF EXISTING FACILITIES
CALL 811 TWO BUSINESS DAYS BEFORE YOU DIG
For contacts below dial 1-888-CALL PSE (225-5773)
UTILITIES
CONTACT
PHONE#
COUNTY
1/4 SEC
U-MAP NO (POWER)
OP MAP
Emer Sect Gas Wk Ctr POWER WK CTR
PLAT MAP
JOINT FACILITIES ARRANGEMENTS
DRAWN BY
CHECKED BY
APPROVED BY
FOREMAN #1
FOREMAN #2
MAPPING
INCIDENT MAOP
Gas Order Elect Order
SCALE PAGE
ENGR - POWER
ENGR - GAS
FUNCTION
PROJECT MGR
PERMITREAL ESTATE/EASEMENT
2
1
REV#
3
DATE DESCRIPTIONBY
CONTACT PHONE NO DATE
OH CKT MAP CIRCUIT NOUG CKT MAP
Val Buzunov (425) 457-9938 9/18/17
Nate Linville (253) 970-7284 9/18/17
N/A N/A N/A
Nate Linville (253) 970-7284
Required City of Renton
Monster - Crown Castle
REPL BO POLE, SEC LE TO NEW SEC HH, CONNECT COM'L SVC
1400 Monster RD SW, Renton, WA 98055
N/A N/A
N/A 105086306
AS NOTED 1 OF 1
KING N/A N/A CSPSKEPM
NW-24-23-04E N/A N/A
2304E095 2304E094 2304E095 RJN-11
CENTURYLINK
N/A
N/A
COMCAST
N/A
N/A
N/A
N/A
N/A
N/A
N/A
N/A
N/A N/A N/A
N/A N/A N/A
N/A N/A N/A
Service Stubs
105086306
N/A
N/A
AT P01: REPLACE (317360-165204)
REMOVE EXISTING 1957 40' UNK CL POLE AND ASSOCIATED EQUIPMENT
TRANSFER EXISTING 25kVA 120/240V TRANSFORMER TO NEW POLE
-INST. 1 - 45' CL2 DIST POLE PER STD 6010.1000 (PD452)
-INST. 2 - 9' 8P XARMS PER STD 6033.1046 (ARD2H09)
-INST. 2 - 15kV PTP & INSULATOR
-INST. 4 - STEEL ARM PINS & INSULATORS
-INST. 6 - 12kV ARM MOUNTED DEAD ENDS (N, S) PER STD 6033.1046 (DED001A)
-INST. 1 - L/B TRANSFORMER C/O ON C/O ARM, TAP CØ
-INST. RCNC (W)
-INST. 1 - 3" SECONDARY RISER ON NEW S/O BRKTS PER STD 6042.1000 (RIS3CSS)
-INST. GRID 317360-165204
COMMUNICATIONS TO TRANSFER
AT HH1: NEW
-INST. 1 - 17" X 30" PE SECONDARY HAND HOLE PER 6050.2000 (HH16450)
-INST. 3 - #10 - 350KCMIL SECONDARY CONNECTIONS BLOCKS PER STD 6050.2000 (MID: 7651006)
CONNECT AND TAG 1 - RUN CUSTOMER INSTALLED OWNED MAINTAINED #2 CU TPLX.
AT M01:
PSE METER DEPARTMENT TO SET CL200 METER
SPAN NOTES
P01 TO HH1
-INST. 1 - 3" SCH80 CONDUIT IN CUSTOMER PROVIDED TRENCH
-INST. 1 - 350KCMIL SEC TPLX
DEVELOPER & CUSTOMER NOTES:
THE CUSTOMER IS RESPONSIBLE FOR PROVIDING ALL TRENCHING, SELECT BACKFILL, COMPACTION &
RESTORATION PER PUGET SOUND ENERGY STANDARDS 6750.6500
-REQUIRED TO PROVIDE 5' X 5' WORK PIT & 1 CUBIC YARD OF 5/8" MINUS AT HH1
-REQUIRED TO PROVIDE 4' X 4' WORK PIT AT P01
-REQUIRED TO FOLLOW ALL TRENCH DETAILS ON SELECT BACKFILL
-REQUIRED TO PROVIDE EQUIPMENT TO PUMP OUT WATER FOR WORK PITS & TRENCH AT ALL TIMES
-EXCAVATE & EXPOSE EXISTING PSE UG FACILITIES 48 HOURS PRIOR TO CONSTRUCTION
-PSE INSPECTION IS REQUIRED PRIOR TO FINAL BACKFILL
-PSE WILL NOT ENERGIZE FACILITIES UNTIL BACKFILL IS COMPLETE
-L&I INSPECTION & APPROVAL IS REQUIRED 72 HOURS PRIOR TO CONNECTION
-RESPONSIBLE FOR ALL TREE TRIMMING AND BRUSH CLEARING
POLE RETIREMENT TABLE TEMP TRANSFERS ST. LIGHT TRANSFERS
SITE
#
POLE DATA POLE
TEL TV FIBER TRAN RMVD ID NUMBER
GRID #HEIGHT CLASS YEAR TOPPED RMVD
P01 317360-165204 40 2 1957
POLE TABLE (NEW)
Site
#
Pole Data
Grid #Height Class Year Remarks / Location Ref.
P01 317360-165204 45 2 2017 PSE Equip #
TRENCH DETAIL
Electric Service Cable in Conduit (NTS)
Electric Service Cable in Conduit
Excavated Dirt Pile
Final Grade
24" Min
24" Min
to
36" Max
Cover
12" Typical
(6" Min)
Backfill for Conduit
Free of rocks
larger than 8"
in diameter)
36" MINIMUM COVER
IN RIGHT OF WAY
To Excavated Dirt Pile
3" Schedule 80 Grey PVC
Backfill for In Conduit - The backfill layer shall be soil that is free from construction debris,
glass, sharp rocks, frozen clods, and rocks larger than 8" in diameter.
Customer's
service
conductors
Captive L-Bolt
27-1/4"
2"
18"
Captive L-Bolt
Lock Cover, 10 lbs
40-1/2"
Conductors enter from
beneath and shall be
folded back with handhole
SIDE VIEW
Lock Cover
30"
Approx
Approx
17"
Set handhole flush
to final grade
SINGLE PHASE SECONDARY HANDHOLE
Not to scale 6050.2000
PSE PROVIDED & INSTALLED
1 - SCH GRAY 80 PVC CONDUIT
1 - 350KCMIL SEC TPLX IN
CUSTOMER PROVIDED TRENCH
5' X 5' WORK PIT
4' X 4' WORK PIT
FLOW DIRECTION
LAY 8" BOTTOM SKIRT ON TOP OF NATIVE SOIL,
SECURE WITH PEA GRAVEL BAGS (MID 9995692).
6'
3'
8"
TECHNIQUES FOR EROSION AND SEDIMENT CONTROL
FILTER FENCE DETAIL
Not to Scale 0150.3200
1 YRD 5/8" MINUS
CIRCUIT FEET ADDED: NONE
LRC:
% V. Drop:
% Flicker:
Sq. Footage:
Panel Size:
Heat Type:
Est. Demand:
0 SQ.
200AMPS
NONE
30KW
65A
2.5%
1.5%
AT P01
LRC:
% V. Drop:
% Flicker:
Sq. Footage:
Panel Size:
Heat Type:
Est. Demand:
0 SQ.
200AMPS
NONE
30KW
65A
3.3%
2.1%
AT HH1