Loading...
HomeMy WebLinkAboutP_Design_105086306_V1_170929317360-165204 25kVA 120/240v MONSTER RD SW317368-165207 X831 317364-165224 336.4 MCMACSRCBA1400#CELLJACK SON P L SW ( P V T ) "1400" WORK ZONE WORK ZONEMONS T ER RD SW J AC K SON P L SW SW 1 6 T H S T SITE PLAN Owner / Developer Contact Info officeATTN: Verizon Wireless PO BOX 2375 Spokane, WA 99210-2375 RyanHarmon (425) 999-2323 SITE SPECIFIC NOTES OVERHEAD CIRCUIT MAP SCALE: 6" = 1 MILE ARE TO BE INSTALLED, CROSS SECTION DETAILS OF THE TYPICAL EROSION STRUCTURES, & SPECIAL REQUIREMENTS FOR WORK IN SENSITIVE AREAS.) EROSION & SEDIMENT CONTROL REQUIREMENTS NOTES DETAILING WHERE EROSION OR SEDIMENT CONTROL STRUCTURES (LOCAL JURISDICTIONS MAY HAVE ADDITIONAL REQUIREMENTS INCLUDING 0150.3200 TECHNIQUES FOR TEMPORARY EROSION & SEDIMENT CONTROL EROSION & SEDIMENT CONTROL SHALL BE PER PSE STANDARD PRACTICE & ANY ADDITIONAL LOCAL JURISDICTION REQUIREMENTS. FOREMAN (CHECK BOX WHEN COMPLETED) PSE Equipment LOCKED/SECURED & Work Area left in CLEAN/SAFE Condition. Grid, Cable, and Switch numbers INSTALLED & VERIFIED. Field Changes RED-LINED on As-built. Indicate correct FUSE SIZE on As-built & VERIFY proper PHASE. Foreman's Signature _______________________________________________ Print Name ___________________________________ Date ______________ Material VERIFIED and CHANGES noted on Paperwork. Total PRIMARY Cable noted on As-built. Company ID#'s RECORDED in correct location on As-built. Deviations noted on the As-built and their reason. I certify that the work performed meets PSE's standards and procedures and that all quality requirements are met. CIRCUIT LOADING TABLE AS OF EXIST. PEAK LOAD EST. NEW LOAD TOTAL CIRCUIT: A PHASE B PHASE C PHASE RJN-11 6/13/17 75 72 68 --3.1 4.90 75 69.9 72.9 GAS PHONE CABLE TV 504868002 N/A 101107585 N/A 108102598 N/A 583057686 N/A 593187732 504924568 104295632 N/A N/A N/A N/A PROJECT PHASE PWR NOTIF#ORDER# Superior Pole Repl Pole Removal Temporary Job Order Distribution HP Svc/MSA SCALE: 6" = 1 MILE SECONDARY CABLE & CONDUIT DIAGRAM POWER GENERAL NOTES - COMMERCIAL PROJECT 8. EXCAVATION: The customer is to provide all trenching, backfill, vault excavations, compaction and restoration per this sketch and per PSE standards. A minimum protective cover of 36" is required over PSE's primary voltage equipment and 24" is required of PSE's secondary voltage equipment. The customer will provide any and all shoring or they will side slope the trench to 1:1. All materials to be installed in accordance with Puget Sound Energy's (PSE) standards. Any deviation from this work sketch must be AUTHORIZED by PSE's Project Manager and NOTED on the Foremans' Copy. All switching arrangements and/or outage arrangements are to be made with the Project Manager at least three (3) working days in advance. Contact the Utilities Underground Location Center (1-800-424-5555) at least 48 hours prior to commencing work to get the underground facilities located. STAKING: The customer will provide all staking (transformer, handhole, trench, grade, lot, pole, sidewalk, etc.). See sketch and details for locations. Equipment locations must be approved by the Project Manager. SITE PREPARATION: The work area will be at or near finished grade, clear of trench spoils or construction materials which would restrict construction and/or equipment access, before work can begin. Roads shall be paved or have a compacted , crushed rock base in place. CLEARANCES: Transformers require a minimum of 6 feet from fire fighting equipment, 10 feet from combustible walls, overhangs, doors, and windows, and a minimum of 5 feet from the back of curb (or guard posts will be required per PSE standards). All conduits and vaults are to be at least 5 feet away from water, storm and sewer lines when paralleling them in the right of way, and at least 1 foot when crossing them. All work is to be done in accordance with local municipal and county permit requirements as applicable. Customer/Developer is responsible to provide, install and maintain all secondary service cables, conduits and crossings from the individual unit's meter base to the designated connection point. Inclement weather conditions may cause delays in construction times and dates. 1. 2. 3. 4. 5. 6. 7. 9. 11. 10. PSE No No No Yes Yes Yes No YesDeveloper "Flagging Required" "Outages Required" "Locates Required" X X XX E-Mail: Cell Phone: Project Manager Contact Information: Manager:Val Buzunov (426) 457-9938 VAL.BUZUNOV@PSE.COM N Vicinity Map N/A SCALE: 1" = 50'105086306THIS SKETCH NOT TO BE RELIED UPON FOR EXACT LOCATION OF EXISTING FACILITIES CALL 811 TWO BUSINESS DAYS BEFORE YOU DIG For contacts below dial 1-888-CALL PSE (225-5773) UTILITIES CONTACT PHONE# COUNTY 1/4 SEC U-MAP NO (POWER) OP MAP Emer Sect Gas Wk Ctr POWER WK CTR PLAT MAP JOINT FACILITIES ARRANGEMENTS DRAWN BY CHECKED BY APPROVED BY FOREMAN #1 FOREMAN #2 MAPPING INCIDENT MAOP Gas Order Elect Order SCALE PAGE ENGR - POWER ENGR - GAS FUNCTION PROJECT MGR PERMITREAL ESTATE/EASEMENT 2 1 REV# 3 DATE DESCRIPTIONBY CONTACT PHONE NO DATE OH CKT MAP CIRCUIT NOUG CKT MAP Val Buzunov (425) 457-9938 9/18/17 Nate Linville (253) 970-7284 9/18/17 N/A N/A N/A Nate Linville (253) 970-7284 Required City of Renton Monster - Crown Castle REPL BO POLE, SEC LE TO NEW SEC HH, CONNECT COM'L SVC 1400 Monster RD SW, Renton, WA 98055 N/A N/A N/A 105086306 AS NOTED 1 OF 1 KING N/A N/A CSPSKEPM NW-24-23-04E N/A N/A 2304E095 2304E094 2304E095 RJN-11 CENTURYLINK N/A N/A COMCAST N/A N/A N/A N/A N/A N/A N/A N/A N/A N/A N/A N/A N/A N/A N/A N/A N/A Service Stubs 105086306 N/A N/A AT P01: REPLACE (317360-165204) REMOVE EXISTING 1957 40' UNK CL POLE AND ASSOCIATED EQUIPMENT TRANSFER EXISTING 25kVA 120/240V TRANSFORMER TO NEW POLE -INST. 1 - 45' CL2 DIST POLE PER STD 6010.1000 (PD452) -INST. 2 - 9' 8P XARMS PER STD 6033.1046 (ARD2H09) -INST. 2 - 15kV PTP & INSULATOR -INST. 4 - STEEL ARM PINS & INSULATORS -INST. 6 - 12kV ARM MOUNTED DEAD ENDS (N, S) PER STD 6033.1046 (DED001A) -INST. 1 - L/B TRANSFORMER C/O ON C/O ARM, TAP CØ -INST. RCNC (W) -INST. 1 - 3" SECONDARY RISER ON NEW S/O BRKTS PER STD 6042.1000 (RIS3CSS) -INST. GRID 317360-165204 COMMUNICATIONS TO TRANSFER AT HH1: NEW -INST. 1 - 17" X 30" PE SECONDARY HAND HOLE PER 6050.2000 (HH16450) -INST. 3 - #10 - 350KCMIL SECONDARY CONNECTIONS BLOCKS PER STD 6050.2000 (MID: 7651006) CONNECT AND TAG 1 - RUN CUSTOMER INSTALLED OWNED MAINTAINED #2 CU TPLX. AT M01: PSE METER DEPARTMENT TO SET CL200 METER SPAN NOTES P01 TO HH1 -INST. 1 - 3" SCH80 CONDUIT IN CUSTOMER PROVIDED TRENCH -INST. 1 - 350KCMIL SEC TPLX DEVELOPER & CUSTOMER NOTES: THE CUSTOMER IS RESPONSIBLE FOR PROVIDING ALL TRENCHING, SELECT BACKFILL, COMPACTION & RESTORATION PER PUGET SOUND ENERGY STANDARDS 6750.6500 -REQUIRED TO PROVIDE 5' X 5' WORK PIT & 1 CUBIC YARD OF 5/8" MINUS AT HH1 -REQUIRED TO PROVIDE 4' X 4' WORK PIT AT P01 -REQUIRED TO FOLLOW ALL TRENCH DETAILS ON SELECT BACKFILL -REQUIRED TO PROVIDE EQUIPMENT TO PUMP OUT WATER FOR WORK PITS & TRENCH AT ALL TIMES -EXCAVATE & EXPOSE EXISTING PSE UG FACILITIES 48 HOURS PRIOR TO CONSTRUCTION -PSE INSPECTION IS REQUIRED PRIOR TO FINAL BACKFILL -PSE WILL NOT ENERGIZE FACILITIES UNTIL BACKFILL IS COMPLETE -L&I INSPECTION & APPROVAL IS REQUIRED 72 HOURS PRIOR TO CONNECTION -RESPONSIBLE FOR ALL TREE TRIMMING AND BRUSH CLEARING POLE RETIREMENT TABLE TEMP TRANSFERS ST. LIGHT TRANSFERS SITE # POLE DATA POLE TEL TV FIBER TRAN RMVD ID NUMBER GRID #HEIGHT CLASS YEAR TOPPED RMVD P01 317360-165204 40 2 1957 POLE TABLE (NEW) Site # Pole Data Grid #Height Class Year Remarks / Location Ref. P01 317360-165204 45 2 2017 PSE Equip # TRENCH DETAIL Electric Service Cable in Conduit (NTS) Electric Service Cable in Conduit Excavated Dirt Pile Final Grade 24" Min 24" Min to 36" Max Cover 12" Typical (6" Min) Backfill for Conduit Free of rocks larger than 8" in diameter) 36" MINIMUM COVER IN RIGHT OF WAY To Excavated Dirt Pile 3" Schedule 80 Grey PVC Backfill for In Conduit - The backfill layer shall be soil that is free from construction debris, glass, sharp rocks, frozen clods, and rocks larger than 8" in diameter. Customer's service conductors Captive L-Bolt 27-1/4" 2" 18" Captive L-Bolt Lock Cover, 10 lbs 40-1/2" Conductors enter from beneath and shall be folded back with handhole SIDE VIEW Lock Cover 30" Approx Approx 17" Set handhole flush to final grade SINGLE PHASE SECONDARY HANDHOLE Not to scale 6050.2000 PSE PROVIDED & INSTALLED 1 - SCH GRAY 80 PVC CONDUIT 1 - 350KCMIL SEC TPLX IN CUSTOMER PROVIDED TRENCH 5' X 5' WORK PIT 4' X 4' WORK PIT FLOW DIRECTION LAY 8" BOTTOM SKIRT ON TOP OF NATIVE SOIL, SECURE WITH PEA GRAVEL BAGS (MID 9995692). 6' 3' 8" TECHNIQUES FOR EROSION AND SEDIMENT CONTROL FILTER FENCE DETAIL Not to Scale 0150.3200 1 YRD 5/8" MINUS CIRCUIT FEET ADDED: NONE LRC: % V. Drop: % Flicker: Sq. Footage: Panel Size: Heat Type: Est. Demand: 0 SQ. 200AMPS NONE 30KW 65A 2.5% 1.5% AT P01 LRC: % V. Drop: % Flicker: Sq. Footage: Panel Size: Heat Type: Est. Demand: 0 SQ. 200AMPS NONE 30KW 65A 3.3% 2.1% AT HH1