Loading...
HomeMy WebLinkAboutP_Design_105086571_V1_1710201216 37193725 3706 3713 3711 3619 3613 36073604 1213 1205 120111151109 3701 1208120211141108 D/R "1201"DRIVEWAYN 37TH STN 37TH ST 60' 319450-166172 STORM DRAIN WHITE LINE HAZ 15 ADU 319451-166208 319449-166190 15 KVA 120/240V 37.5 KVA 120/240V JOB SITE ASPHALT SHOULDER STORM DRAIN 4' X 4' WORK PIT 3/4 YARD OF SAND N 37TH STN 37TH ST 3' 10' 15' BORE ±60' 4' X 4' WORK PIT 4 'X 4' WORK PIT 5' X 6' WORK PIT 4' X 6' BORE PIT DRIVEWAY-CUSTOMER TO INSTALL 1-3"SCH'L 80 CONDUIT, ±145' -PSE TO INSTALL 1-RUN 350KCMIL UG TPX, ±145' -PSE TO INSTALL 1-RUN OF 4/0 KCMIL UG TPX TAIL, ±10' -CUSTOMER TO INSTALL 1-3"SCH'L 80 CONDUIT, ±210' -PSE TO INSTALL 1-RUN 350KCMIL UG TPX, ±210' -PSE TO INSTALL 1-RUN OF 4/0 KCMIL UG TPX TAIL, ±10' WHITE LINE JOB SITE SITE PLAN POWER GENERAL NOTES - RESIDENTIAL PROJECT N Vicinity Map N/A Owner / Developer Contact Info officeATTN: ALI KIMIAI 1201 N 37TH ST RENTON, WA 98056 ALI KIMIAI 425-919-1809 OVERHEAD CIRCUIT MAP SCALE: 6" = 1 MILESCALE: NONE CIRCUIT ONE-LINE DIAGRAM CIRCUIT LOADING TABLE AS OF EXIST. PEAK LOAD EST. NEW LOAD TOTAL CIRCUIT: A PHASE B PHASE C PHASE HAZ-15 2017 201 261 240 -3.95 - 201 264.95 240 OH TRF Removal Perm. Service Superior ORDER#NOTIF# PWR PROJECT PHASE 104296642505017596 108103039 101108129505017544 108103038 101108127 CABLE TV PHONE FOREMAN (CHECK BOX WHEN COMPLETED) PSE Equipment LOCKED/SECURED & Work Area left in CLEAN/SAFE Condition. Grid, Cable, and Switch numbers INSTALLED & VERIFIED. Field Changes RED-LINED on As-built. Indicate correct FUSE SIZE on As-built & VERIFY proper PHASE. Foreman's Signature _______________________________________________ Print Name ___________________________________ Date ______________ Material VERIFIED and CHANGES noted on Paperwork. Total PRIMARY Cable noted on As-built. Company ID#'s RECORDED in correct location on As-built. Deviations noted on the As-built and their reason. I certify that the work performed meets PSE's standards and procedures and that all quality requirements are met. 10. 7. 6. 5. 4. 3. 2. 1.All materials to be installed in accordance with Puget Sound Energy's (PSE) standards. Any deviation from this work sketch must be AUTHORIZED by PSE's Project Manager and NOTED on the Foremans' Copy. All switching arrangements and/or outage arrangements are to be made with the Project Manager at least three (3) working days in advance. Contact the Utilities Underground Location Center (1-800-424-5555) at least 48 hours prior to commencing work to get the underground facilities located. STAKING: The customer will provide all staking (transformer, handhole, trench, grade, lot, pole, sidewalk, etc.). See sketch and details for locations. Equipment locations must be approved by the Project Manager. SITE PREPARATION: The work area will be at or near finished grade, clear of trench spoils or construction materials which would restrict construction and/or equipment access, before work can begin. Roads shall be paved or have a compacted , crushed rock base in place. CLEARANCES: Transformers require a minimum of 6 feet from fire fighting equipment, 10 feet from combustible walls, overhangs, doors, and windows, and a minimum of 5 feet from the back of curb (or guard posts will be required per PSE standards). All conduits and vaults are to be at least 5 feet away from water, storm and sewer lines when paralleling them in the right of way, and at least 1 foot when crossing them. All work is to be done in accordance with local municipal and county permit requirements as applicable. Inclement weather conditions may cause delays in construction times and dates. EXCAVATION: The customer is to provide all trenching, backfill, vault excavations, compaction and restoration per this sketch and per PSE standards. A minimum protective cover of 36" is required over PSE's primary voltage equipment and 24" is required of PSE's secondary voltage equipment. The customer will provide any and all shoring or they will side slope the trench to 1:1. 8. 9. E-Mail: Cell Phone: Project Manager Contact Information: Manager:RUSSELL PAGE 253-245-0192 RUSSELL.PAGE@PSE.COM PSE No No No Yes Yes Yes No YesDeveloper "Flagging Required" "Outages Required" "Locates Required" Installed at site: Grid Number: kVA Rating: Foreman to redline the following information TRANSFORMER INSTALLATION Company ID#: Primary phase connected to: Tested Secondary Voltage Material ID#: P01 319449-166190 37.5 KVA 120/240V 6211300 SCALE: 1" = 50'105086571THIS SKETCH NOT TO BE RELIED UPON FOR EXACT LOCATION OF EXISTING FACILITIES CALL 811 TWO BUSINESS DAYS BEFORE YOU DIG For contacts below dial 1-888-CALL PSE (225-5773) 105086571 593188626 UTILITIES CONTACT PHONE# COUNTY 1/4 SEC U-MAP NO (POWER) OP MAP Emer Sect Gas Wk Ctr POWER WK CTR PLAT MAP JOINT FACILITIES ARRANGEMENTS DRAWN BY CHECKED BY APPROVED BY FOREMAN #1 FOREMAN #2 MAPPING INCIDENT MAOP Gas Order Elect Order SCALE PAGE ENGR - POWER ENGR - GAS FUNCTION PROJECT MGR PERMITREAL ESTATE/EASEMENT 2 1 REV# 3 DATE DESCRIPTIONBY CONTACT PHONE NO DATE OH CKT MAP CIRCUIT NOUG CKT MAP RUSSELL PAGE 253-245-0192 10/2/17 RUSSELL PAGE 253-245-0192 10/2/17 N/A N/A N/A TIN NGUYEN 253-244-4303 10/2/17 EASEMENT RENTON ALI KIMIAI OH TO UG CONVERSION /W POLE REM & OH TRF UPGRADE 1201 N 37TH ST, RENTON WA 98056 N/A N/A N/A 105086571 N/A 1/2 KING N/A N/A CSPSKEIN NW32-24N-05E N/A N/A 2405E126 2405E136 2405E126 HAZ-15 N/A N/A N/A N/A N/A N/A N/A N/A N/A N/A N/A N/A N/A N/A N/A N/A N/A N/A N/A N/A N/A 504858529 LRC: % V. Drop: % Flicker: Sq. Footage: Panel Size: Heat Type: Est. Demand: 2780 SQ. 200 AMPS ELECTRIC 14 KW 115 A 3.3 % 3.3 % SITE SPECIFIC NOTES P01 GRID# 319449-166190: -REMOVE EXISTING B/O 40' POLE -INSTALL 1-45' CL-3 DISTRIBUTION POLE W/GNDS -INSTALL 1-POLE TOP PIN -REMOVE EXISTING 15KVA 120/240 OH TRF -INSTALL 37.5KVA 120/240 OH TRF -INSTALL LB C/O FUSE @15T & TAP BØ -INSTALL 1-STIRRUP BOLT -INSTALL 2-RIGID CLEVIS (NORTH & SOUTH) -TRANSFER OH SERVICE "1114", "1202", "1115" -COMMUNICATIONS TO TRANSFER -INSTALL NEW GRID# 319437-166190 HH1: -INSTALL 17"X30" SECONDARY HANDHOLE -INSTALL 3-6 POSITION FARGO BARS M01: -INSTALL 1-200AMP METER M02: -INSTALL 1-200AMP METER SPAN SPECIFIC NOTES P01/X01-HH1: -BORE AND INSTALL 1-3" RED POLY CONDUIT, ±75' -INSTALL 1-RUN OF 350KCMIL UG TPX, ±110' P01-"1201": -REMOVE EXISTING OH SEC CONDUCTOR & EXISTING METER HH1 - M01: -CUSTOMER TO INSTALL 1-3" SCH'L 80 CONDUIT, ±145' -PSE TO INSTALL 1-RUN OF 350KCMIL UG TPX, ±155' -PSE TO INTERCEPT & INSTALL 1-RUN OF 4/0KCMIL UG TPX TAIL, ±10' HH1 - M02: -CUSTOMER TO INSTALL 1-3" SCH'L 80 CONDUIT, ±210' -PSE TO INSTALL 1-RUN OF 350KCMIL UG TPX, ±220' -PSE TO INTERCEPT & INSTALL 1-RUN OF 40/KCMIL UG PTX TAIL, ±10' CUSTOMER DEVELOPMENT NOTES CUSTOMER IS RESPONSIBLE FOR ALL TRENCHING, SELECT BACKFILL, COMPACTION & RESTORATION PER PUGET SOUND ENERGY STANDARDS. #6750.6500 **DEVELOPER NEEDS TO FOLLOW ALL TRENCH DETAILS ON SELECT BACKFILL** -CUSTOMER IS REQUIRED TO PROVIDE A 4' X 4' WORK PIT AT P01. -CUSTOMER IS REQUIRED TO PROVED A 4' x 6' BORE PIT ON P01 SIDE. -CUSTOMER IS REQUIRED TO PROVIDE A 5' X 6' WORK PIT AT HH1. -CUSTOMER IS REQUIRED TO PROVIDE A 4' X 4' WORK PIT & 3/4 YARD OF SAND AT M01. -CUSTOMER IS REQUIRED TO PROVIDE A 4' X 4' WORK PIT & 3/4 YARD OF SAND AT M02. -CUSTOMER TO BORE & INSTALL “ OF 1-3" DISCONTINUOUS RED POLY CONDUIT FROM P01-HH1. -CUSTOMER TO EXCAVATE & INSTALL “ OF 1-3" DISCONTINUOUS SCH'L 80 GRAY PVC CONDUIT FROM HH1-M01. --CUSTOMER TO EXCAVATE & INSTALL “ OF 1-3" DISCONTINUOUS SCH'L 80 GRAY PVC CONDUIT FROM HH1-M02. -CUSTOMER IS REQUIRED TO PROVIDE AND INSTALL A 3/8" NON-POLY PULL ROPE IN CONDUIT. -CUSTOMER MUST HAVE A COPY OF PSE PROVIDED PERMIT ON SITE DURING ANY DIGGING IN RIGHT OF WAY. -CUSTOMER IS REQUIRED TO INSTALL METER BASE ON FRONT 1/3 OF BUILDING. ALL TRENCHING WILL REQUIRE AN INSPECTION BY PSE BEFORE FINAL BACKFILL ALL TRENCH AND L&I INSPECTION MUST BE COMPLETED 72HRS BEFORE CONSTRUCTION 583057918 OUTAGE LIST 1115 N 37TH ST, RENTON WA 98056 1201 N 37TH ST, RENTON WA 98056 1114 N 37TH ST, RENTON WA 98056 1202 N 37TH ST, RENTON WA 98056 CIRCUIT FEET ADDED: 0' LRC: % V. Drop: % Flicker: Sq. Footage: Panel Size: Heat Type: Est. Demand: 1600 SQ. 200 AMPS ELECTRIC 13 KW 80 A 3.5 % 2.6 % HH1-M02 Removed at site: Grid Number: kVA Rating: Foreman to redline the following information TRANSFORMER REMOVAL Company ID#: Primary phase connected to: Tested Secondary Voltage P01 319449-166190 15KVA 120/240V Standoff Bracket 15" Min Length Conduit Clamp Conduit Field Face Quadrant Climbing Space Road Face Quadrant Climbing Space 5" Min CL LCDirection of Vehicular Traffic CONDUIT RISER PLACEMENT DETAIL TOP VIEW Not to Scale 186050040 P01-HH1 HH1-M01 LRC: % V. Drop: % Flicker: Sq. Footage: Panel Size: Heat Type: Est. Demand: SQ. AMPS 27 KW A 2.8 % 2.3 % New Handhole/Pole Pole Removal OH Misc Purchase Conduit Perm. Service Ex. Svc Removal POLE RETIREMENT TABLE TEMP TRANSFERS ST. LIGHT TRANSFERS SITE # POLE DATA POLE TEL TV FIBER TRAN RMVD ID NUMBER GRID #HEIGHT CLASS YEAR TOPPED RMVD P01 319449-166190 40 1956 POLE TABLE (NEW) Site # Pole Data Grid #Height Class Year Remarks / Location Ref. P01 319449-166190 45 3 2017 PSE Equip #8974503 WIRE REMOVAL TABLE Location Wire Size & Type Quantity Length (per conductor)RemarksFromTo P01 M01 UNK 1 85 FT ARE TO BE INSTALLED, CROSS SECTION DETAILS OF THE TYPICAL EROSION STRUCTURES, & SPECIAL REQUIREMENTS FOR WORK IN SENSITIVE AREAS.) EROSION & SEDIMENT CONTROL REQUIREMENTS NOTES DETAILING WHERE EROSION OR SEDIMENT CONTROL STRUCTURES (LOCAL JURISDICTIONS MAY HAVE ADDITIONAL REQUIREMENTS INCLUDING 0150.3200 TECHNIQUES FOR TEMPORARY EROSION & SEDIMENT CONTROL EROSION & SEDIMENT CONTROL SHALL BE PER PSE STANDARD PRACTICE & ANY ADDITIONAL LOCAL JURISDICTION REQUIREMENTS. UTILITIES CONTACT PHONE# COUNTY 1/4 SEC U-MAP NO (POWER) OP MAP Emer Sect Gas Wk Ctr POWER WK CTR PLAT MAP JOINT FACILITIES ARRANGEMENTS DRAWN BY CHECKED BY APPROVED BY FOREMAN #1 FOREMAN #2 MAPPING INCIDENT MAOP Gas Order Elect Order SCALE PAGE ENGR - POWER ENGR - GAS FUNCTION PROJECT MGR PERMITREAL ESTATE/EASEMENT 2 1 REV# 3 DATE DESCRIPTIONBY CONTACT PHONE NO DATE OH CKT MAP CIRCUIT NOUG CKT MAP RUSSELL PAGE 253-245-0192 10/2/17 RUSSELL PAGE 253-245-0192 10/2/17 N/A N/A N/A TIN NGUYEN 253-244-4303 10/2/17 EASEMENT RENTON ALI KIMIAI OH TO UG CONVERSION /W POLE REM & OH TRF UPGRADE 1201 N 37TH ST, RENTON WA 98056 N/A N/A N/A 105086571 N/A 2/2 KING N/A N/A CSPSKEIN NW32-24N-05E N/A N/A 2405E126 2405E136 2405E126 HAZ-15 N/A N/A N/A N/A N/A N/A N/A N/A N/A N/A N/A N/A N/A N/A N/A N/A N/A N/A N/A N/A N/A TV & TEL Electric Service Cable in Conduit 3" Schedule 80 Grey PVC Excavated Dirt Pile Final Grade 24" Min 24" Min to 36" Max Cover Separation 12" Min 20" Min JOINT TRENCH DETAIL Electric Service Cable in Conduit (NTS) To Excavated Dirt Pile 36" MINIMUM COVER IN RIGHT OF WAY Backfill for In Conduit - The backfill layer shall be soil that is free from construction debris, glass, sharp rocks, frozen clods, and rocks larger than 8" in diameter. Backfill for Conduit Free of rocks larger than 8" in diameter) FLOW DIRECTION LAY 8" BOTTOM SKIRT ON TOP OF NATIVE SOIL, SECURE WITH PEA GRAVEL BAGS (MID 9995692). 6' 3' 8" TECHNIQUES FOR EROSION AND SEDIMENT CONTROL FILTER FENCE DETAIL Not to Scale 0150.3200 UTILITY POLE EROSION CONTROL DETAIL TOP VIEW DRY DRAINAGE DITCH or DRY VEGETATED SITE SLOPE Place gravel bags for Sediment Trap Place straw mulch on disturbed areaExcavated or Augered Hole Pole SLOPE Not to scale Drainage ditches or Dry vegetated sites 32" Typical 24" Min 24"-36" 24"-36" 4'Top View Electric & Joint Utility Work Pit Dimensions 36" Min Drainage Pipe 12" Minimum Clearance from Gas Service Lines Conduit Depth 24" to 36" Max Regulator Vent Gas Meter Assembly Utility Provided 48" 4'8" Service (Permanent Detail:) Not to Scale Seal Conduit Ends Closed 4'8" 24" Min 36" Typical 3' To Trench Property Line Conduit Stakes Customer Provided 3" Schedule 80 Grey PVC Power Cable Conduit Customer Provided Gas Service Line Conduit Sch 40 White PVC Customer Provided 3" Conduit Service Riser Customer Provided Elec. Mtr Base Elec Mtr utility provided Gas Meter Relief Vent Building Wall Elec. Mtr PERMANENT METER DETAIL AT M01 & M02 SCALE: NONE BORE PIT DETAIL Electric Service Cable in Conduit Final Grade 24" Min 24" Min to 36" Max Cover 12" Typical (6" Min) 36" MINIMUM COVER IN RIGHT OF WAY To Excavated Dirt Pile 3" Red Polyethelene SCALE: NONE Customer's service conductors27-1/4" 18" Captive L-Bolt Lock Cover, 10 lbs 40-1/2" Conductors enter from beneath and shall be folded back with handhole SIDE VIEW 2" 30" Approx Approx 17" TOP VIEW 6' 5' SINGLE PHASE SECONDARY HANDHOLE AT HH1 SCALE: NONE 6050.2000