HomeMy WebLinkAboutP_Design_101108434_V1_171106PARCEL #3342101525BURNETT AVE N50'50'HAZ15N 32ND ST50'91550kVA 120/240v25kVA 120/240v50'CUSTOMER SUPPLIED4' X 4' WORK PITCUSTOMER SUPPLIED4' X 4' WORK PIT1-3" SCHED'L 80 PVC CONDUIT ± 125'INST. 1-RUN 4/0 UG TPX ± 160'CUSTOMER SUPPLIEDSCHED'L 80 PVC CONDUIT ± 45'CUSTOMER TO CUT & INSTALL 3/4" CUBIC YARD SANDCUSTOMER SUPPLIEDCUSTOMER SUPPLIED1 CUBIC YARD 5/8" CRUSHED ROCK90°90°HAZ15N 32ND ST50'91550kVA 120/240v25kVA 120/240v50'SITE PLANNVicinity MapN/AOwner / Developer Contact InfoofficeATTN:VAWTER CONSTRUCTION COMPANY INC.21036 98TH AVE SKENT, WA 98031GARY VAWTER(206) 849-6376ARE TO BE INSTALLED, CROSS SECTION DETAILS OF THE TYPICAL EROSIONSTRUCTURES, & SPECIAL REQUIREMENTS FOR WORK IN SENSITIVE AREAS.)EROSION & SEDIMENT CONTROL REQUIREMENTSNOTES DETAILING WHERE EROSION OR SEDIMENT CONTROL STRUCTURES(LOCAL JURISDICTIONS MAY HAVE ADDITIONAL REQUIREMENTS INCLUDING0150.3200 TECHNIQUES FOR TEMPORARY EROSION & SEDIMENT CONTROLEROSION & SEDIMENT CONTROL SHALL BE PER PSE STANDARD PRACTICE& ANY ADDITIONAL LOCAL JURISDICTION REQUIREMENTS.STANDARD EASEMENT PROVISIONAn easement is hereby reserved for and conveyed to Puget Sound Energy,Inc., Telephone Co., Television Cable Co., and their respective successorsand assigns under and upon the private street(s), if any, and the exteriorten (10) feet of all lots, tracts and spaces with in the plat lying parallel withand adjoining all street(s) in which to construct, operate, maintain, repair,replace and enlarge underground or ground-mounted appurtenancesthereto for the purpose of serving this subdivision and other property withelectric, gas, telephone and other utility service, together with the right toenter upon the streets, lots, tracts and spaces at all times for the purposesherein stated.101108434FOREMAN (CHECK BOX WHEN COMPLETED)PSE Equipment LOCKED/SECURED & Work Area left in CLEAN/SAFE Condition.Grid, Cable, and Switch numbers INSTALLED & VERIFIED.Field Changes RED-LINED on As-built.Indicate correct FUSE SIZE on As-built & VERIFY proper PHASE.Foreman's Signature _______________________________________________Print Name ___________________________________ Date ______________Material VERIFIED and CHANGES noted on Paperwork.Total PRIMARY Cable noted on As-built.Company ID#'s RECORDED in correct location on As-built.Deviations noted on the As-built and their reason.I certify that the work performed meets PSE's standards and procedures and that all quality requirements are met.GASPHONECABLE TVPROJECT PHASEPWRNOTIF#ORDER#SuperiorE-Mail:Cell Phone:Project Manager Contact Information:Manager:RUSSELL PAGE(253) 234-6444RUSSELL.PAGE@PSE.COMPSENoNoNoYesYesYesNoYesDeveloper"Flagging Required""Outages Required""Locates Required"SCALE: 1" = 50'THIS SKETCH NOT TO BE RELIED UPON FOR EXACT LOCATION OF EXISTING FACILITIESCALL 811 TWO BUSINESS DAYS BEFORE YOU DIGFor contacts below dial 1-888-CALL PSE (225-5773)UTILITIESCONTACTPHONE#COUNTY1/4 SECU-MAP NO (POWER)OP MAPEmer SectGas Wk CtrPOWER WK CTRPLAT MAPJOINT FACILITIES ARRANGEMENTSDRAWN BYCHECKED BYAPPROVED BYFOREMAN #1FOREMAN #2MAPPINGINCIDENTMAOPGas OrderElect OrderSCALEPAGEENGR - POWERENGR - GASFUNCTIONPROJECT MGRPERMITREAL ESTATE/EASEMENT21REV#3DATEDESCRIPTIONBYCONTACTPHONE NODATEOH CKT MAPCIRCUIT NOUG CKT MAPR. PAGE(253) 234-644410/12/17R. PAGE(253) 234-644410/12/17T. MYER(714) 893-240510/12/17REQ'DRENTONOH TO UG FOR DEMO REBUILDNEW TRANSFORMER, SVC CONVERSION915 N 32ND ST, RENTON, WA 98056N/AN/AN/A101108434AS NOTED1 OF 1KINGN/AN/ACSPSKEINSW 32-24N-05EN/AN/A2405E1272405E1242405E127HAZ-15N/AN/AN/AN/AN/AN/AN/AN/AN/AN/AN/AN/AN/AN/AN/AN/AN/AN/AN/AN/AN/A10110843450485845132"Typical24"Min24"-36"24"-36"4'Top ViewElectric & Joint UtilityWork Pit Dimensions36"MinDrainage Pipe12" Minimum Clearancefrom Gas Service LinesConduit Depth24" to 36" MaxRegulator VentGas Meter AssemblyUtility Provided48"4'8"Service (Permanent Detail:)Not to ScaleSealConduitEndsClosed4'8"24" Min36" Typical3'To TrenchProperty LineConduit StakesCustomer Provided3" Schedule 40 Grey PVCPower Cable ConduitCustomer ProvidedGas Service Line ConduitSch 40 White PVCCustomer Provided3" Conduit Service RiserCustomer ProvidedElec. Mtr BaseElec Mtrutility providedGas MeterRelief VentBuilding WallElec. MtrSCALE: NONEMETER DETAIL @ M01SITE SPECIFIC NOTESP01: 319288-166104-EXISTING POLE TO REMAIN-INSTALL 25kVA 120/240v (FUSE @ 10T) (TRFNXF) PER STD 6025.1000-INSTALL 3" SEC RISER (RIS3CSS) PER STD 6042.1000-REMOVE SEC SPAN TO 319287-166114-REMOVE EXISTING OH SVC TO "915"P02: 319287-166114-EXISTING POLE TO REMAIN-REMOVE SEC. SPAN TO 319288-166104P03: 319288-166099-EXISTING POLE TO REMAIN-TRANSFER SEC SPAN TO NEW XFMR ON 319288-166104M01: NEW METER BASE-INSTALL 200A METERCUSTOMER & DEVELOPER NOTESTHE CUSTOMER IS RESPONSIBLE TO PROVIDE ALL TRENCHING, SELECT BACKFILL, COMPACTION & RESTORATIONPER PUGET SOUND ENERGY STANDARDS 6750.65005(48,5('723529,'( ,167$//´',6&217,1828639&&21'8,7)520P01-M01 +/-170'5(48,5('723529,'( ,167$//´12132/<38//523(,1$//&21'8,76-REQUIRED TO PROVIDE 4' X 4' WORK PIT & 1 CUBIC YARD 5/8" CRUSHED ROCK & 3/4 CUBIC YARD OF SAND AT P015(48,5('723529,'(¶;¶:25.3,7 &8%,&<$5'2)6$1'$7M01-REQUIRED TO FOLLOW ALL TRENCH DETAILS ON SELECT BACKFILL-REQUIRED TO PROVIDE EQUIPMENT TO PUMP OUT WATER FOR WORK PITS & TRENCH AT ALL TIMES-REQUIRED TO EXCAVATE & EXPOSE EXISTING PSE UG FACILITIES 48 HOURS PRIOR TO CONSTRUCTION-PSE INSPECTION IS REQUIRED PRIOR TO FINAL BACKFILL-PSE WILL NOT ENERGIZE FACILITIES UNTIL BACKFILL IS COMPLETE-RENTON INSPECTION & APPROVAL IS REQUIRED 5 BUSINESS DAYS PRIOR TO CONNECTIONSPAN SPECIFIC NOTESX01:&86720(572&87 ,167$//6&+ /3,3(“ 3(536(63(&,),&$7,216-CUSTOMER TO RESTORE ROAD SURFACE PER CITY OF RENTON STANDARDSX01 TO M01:&86720(572,167$//6&+ /&21'8,7“ P01 TO M01:,167$//5818*73;“¶CONDUIT RISER PLACEMENT DETAILSCALE: NONEConduitField FaceQuadrantClimbingSpaceRoad FaceQuadrantClimbingSpace5" MinCLLCDirection of Vehicular TrafficStandoff Bracket15" Min LengthConduit ClampUNDERGROUNDCABLE CONDUITSTO THIS QUADRANTTV & TELElectric Service Cable in Conduit3" Schedule 80 Grey PVCExcavated Dirt PileFinal Grade24" Min24" Minto36" MaxCoverSeparation12" Min20" Min JOINT TRENCH DETAILElectric Service Cable in Conduit (NTS)To Excavated Dirt Pile36" MINIMUM COVERIN RIGHT OF WAYBackfill for ConduitFree of rockslarger than 8"in diameter)Backfill for In Conduit - The backfill layer shall be soil that is free from construction debris,glass, sharp rocks, frozen clods, and rocks larger than 8" in diameter.1.All materials to be installed in accordance with Puget Sound Energy's (PSE) standards. Any deviation from this work sketchmust be AUTHORIZED by PSE's Project Manager and NOTED on the Foremans' Copy.2.All switching arrangements and/or outage arrangements are to be made with the Project Manager at least three (3) workingdays in advance.3.Contact the Utilities Underground Location Center (1-800-424-5555) at least 48 hours prior to commencing work to get theunderground facilities located.4.STAKING: The customer will provide all staking (transformer, handhole, trench, grade, lot, pole, sidewalk, etc.). See sketchand details for locations. Equipment locations must be approved by the Project Manager.5.SITE PREPARATION: The work area will be at or near finished grade, clear of trench spoils or construction materials whichwould restrict construction and/or equipment access, before work can begin.6.Roads shall be paved or have a compacted , crushed rock base in place.7.CLEARANCES: Transformers require a minimum of 6 feet from fire fighting equipment, 10 feet from combustible walls,overhangs, doors, and windows, and a minimum of 5 feet from the back of curb (or guard posts will be required per PSEstandards). All conduits and vaults are to be at least 5 feet away from water, storm and sewer lines when paralleling them inthe right of way, and at least 1 foot when crossing them.8.All work is to be done in accordance with local municipal and county permit requirements as applicable.9.Inclement weather conditions may cause delays in construction times and dates.10.EXCAVATION: The customer is to provide all trenching, backfill, vault excavations, compaction and restoration per thissketch and per PSE standards. A minimum protective cover of 36" is required over PSE's primary voltage equipment and24" is required of PSE's secondary voltage equipment. The customer will provide any and all shoring or they will side slopethe trench to 1:1.POWER GENERAL NOTES - RESIDENTIAL PROJECTCIRCUIT LOADING TABLEAS OFEXIST. PEAK LOADEST. NEW LOADTOTALCIRCUIT:A PHASE B PHASE C PHASEHAZ-1506/2017201.00261.00240.000.000.001.46201.00261.00241.46OVERHEAD CIRCUIT MAP 2405E124SCALE: 6" = 1 MILECIRCUIT FEET ADDED: 0'SQ. FOOTAGE: 3000 SQ FTPANEL SIZE: 320AHEAT TYPE: ELECTRICEST. DEMAND: 10KWLRC: 115A% V. DROP: 2.6%% FLICKER: 3.7%NEW CABLE & CONDUIT DIAGRAMNOT TO SCALEJOB SITEJOB SITEASPLUNDH CONSTRUCTION CORP.TOP VIEW108103426593189543101108471108103427Installed at site:Grid Number:kVA Rating:Foreman to redline the following informationTRANSFORMER INSTALLATIONCompany ID#:Primary phase connected to:Tested Secondary VoltageMaterial ID#:P01319288-16610425kVA6211250Removal505117748depth as mainline trench conduit.3" of Sand Bedding3" of Sand Shading36" Min Cover(38" Max)6"Road crossing must be at samePavementCurbSidewalkR/WROAD CROSSING ELEVATIONNot to scale6790.0075OUTAGE LIST915 N 32ND ST, RENTON, WA 98056 - BEATRICE PAVLIK909 N 32ND ST, RENTON, WA 98056 - KENNETH HUEBNER910 N 32ND ST, RENTON, WA 98056 - CHRISTOPHER BARRYPLACE PEA GRAVELBAGS (MID 9995892)FOR SEDIMENT TRAPPLACE STRAW MULCH ONDISTURBED AREAAUGERED HOLEPOLETYPICAL AUGERED WORK SITE - 0150.3200TECHNIQUES FOR EROSION AND SEDIMENT CONTROLDITCH OR SENSITIVE AREALOCATES DETAILSCALE: 1" = 50'Svc