ABC319229-166186
X9531
319229-166201
50kVA 120/240V
75kVA 120/240DWFuture
House
DWProject
Location
New Riser Customer-Supplied
4' x 4' Work Pit
Customer-Supplied
5'-6" x 4'-5" x 20" Deep
Work Pit
Customer-Supplied
3/4 Yard Sand
Customer-Supplied
4' x 4' Work Pit
350 UG Tpx, ±50', in
Customer-Supplied
3" Sch-40 Conduit, ±30'
2 Runs of 350 UG Tpx, ±100',
in Customer-Supplied
4" Sch-80 Conduit, ±60'4/0 OH Tpx, ±155'
SITE PLAN
N
Vicinity Map
Owner / Developer Contact Info
officeATTN:
Aleksandra Wnek
1118 N 30th Street
Renton WA 98056
Andy Wnek 425-351-8410 105086408THIS SKETCH NOT TO BE RELIED UPON FOR EXACT LOCATION OF EXISTING FACILITIES
CALL (800) 424-5555
2 BUSINESS DAYS BEFORE YOU DIG
For contacts below dial 1-888-CALL PSE (225-5773)
HP Svc/MSA
HP Main
Distribution
Perm. Service
OH Misc.
Remove OH Trans.
Superior
ORDER#NOTIF#
PWR
PROJECT PHASE
N/AN/A
N/AN/A
N/AN/A
101107668504958343
593188037
583057833
105086408503969742
CABLE TV
PHONE
GAS
FOREMAN (CHECK BOX WHEN COMPLETED)
PSE Equipment LOCKED/SECURED & Work Area left in CLEAN/SAFE Condition.
Grid, Cable, and Switch numbers INSTALLED & VERIFIED.
Field Changes RED-LINED on As-built.
Indicate correct FUSE SIZE on As-built & VERIFY proper PHASE.
Foreman's Signature _______________________________________________
Print Name ___________________________________ Date ______________
Material VERIFIED and CHANGES noted on Paperwork.
Total PRIMARY Cable noted on As-built.
Company ID#'s RECORDED in correct location on As-built.
Deviations noted on the As-built and their reason.
I certify that the work performed meets PSE's standards and procedures
and that all quality requirements are met.
DESIGNED BY
UTILITIES
CONTACT
PHONE#
COUNTY
1/4 SEC
U-MAP NO (POWER)
OP MAP
Emer Sect Gas Wk Ctr POWER WK CTR
PLAT MAP
JOINT FACILITIES ARRANGEMENTS
DRAWN BY
CHECKED BY
APPROVED BY
FOREMAN #1
FOREMAN #2
MAPPING
INCIDENT MAOP
Gas Order Elect Order
SCALE PAGE
ENGR - POWER
ENGR - GAS
FUNCTION
PROJECT MGR
PERMITREAL ESTATE/EASEMENT
2
1
REV#
3
DATE DESCRIPTIONBY
CONTACT PHONE NO DATE
OH CKT MAP CIRCUIT NOUG CKT MAP
Dave Goodale 425-495-7049 9/26/17
Leslie Regier 253-395-6928 9/26/17
N/A N/A N/A
Leslie Regier 253-395-6928 9/26/17
Required City of Renton
Andy Wnek
Upgrade OH Transformer, Secondary OH-UG Line Ext., UG Service
1118 N 30th Street, Renton WA 98056
PSE
N/A N/A
N/A 105086408
As Noted 1 of 1
King N/A N/A CSPSKEIN
T24N, R05E, Sec 32 SW N/A N/A
2405E127 2405E136 2405E127 HIG-15
N/A
N/A
N/A
N/A
N/A
N/A
N/A
N/A
N/A
N/A
N/A
N/A
E-Mail:
Cell Phone:
Project Manager Contact Information:
Manager:Dave Goodale
425-495-7049
dave.goodale@pse.com
POWER GENERAL NOTES ‒ RESIDENTIAL PROJECT
1.All materials to be installed in accordance with Puget Sound Energy's (PSE) standards. Any deviation from
this work sketch must be AUTHORIZED by PSE's Project Manager and NOTED on the Foreman's copy.
2.All switching arrangements and/or outage arrangements are to be made with the Project Manager at least
three (3) working days in advance.
3.Contact the Utilities Underground Location Center (1-800-424-5555) at least 48 hours prior to commencing
work to get the underground facilities located.
4.STAKING: The customer will provide all staking (transformer, handhole, trench, grade, lot, pole, sidewalk,
etc.). See sketch and details for locations. Equipment locations must be approved by the Project Manager.
5.SITE PREPARATION: The work area will be at or near finished grade and clear of trench spoils or
construction materials which would restrict construction and/or equipment access, before work can begin.
6.Roads shall be paved or have a compacted, crushed rock base in place.
7.CLEARANCES: Transformers require a minimum of 6 feet from fire fighting equipment, 10 feet from
combustible walls, overhangs, doors, and windows, and a minimum of 5 feet from the back of curb (or guard
posts will be required per PSE standards). All conduits and vaults are to be at least 5 feet away from water,
storm, and sewer lines when paralleling them in the right of way and at least 1 foot when crossing them.
8.All work is to be done in accordance with local municipal and county permit requirements as applicable.
9.Inclement weather conditions may cause delays in construction times and dates.
10.EXCAVATION: The customer is to provide all trenching, backfill, vault excavations, compaction and
restoration per this sketch and per PSE standards. A minimum protective cover of 36" is required over PSE's
primary voltage equipment and 24" is required of PSE's secondary voltage equipment. The customer will
provide any and all shoring or they will side slope the trench to 1:1.
PSE
No
No
No
Yes
Yes
Yes
No
YesDeveloper
"Flagging Required"
"Outages Required"
"Locates Required"
SCALE: 1" = 50'
SITE SPECIFIC NOTES
P01 (319229-166201)
- REMOVE EXISTING 50KVA 120/240V OH TRANSFORMER
-INSTALL NEW 75KVA 120/240V OH TRANSFORMER AND TAP ØB
-INSTALL 1 - RIGID CLEVIS
P02 (319229-166186)
-INSTALL 1 - RIGID CLEVIS
- INSTALL 1 - 4" RISER ON S/O BRACKETS
HH1
- INSTALL 17X30 F/G HANDHOLE
- INSTALL 3 - 6-POS SECONDARY CONNECTORS
SPAN NOTES
P01-P02
-INSTALL 4/0 OH TPX, ±155'
P02 - HH1
- CUSTOMER INSTALL 4" SCH-80 GREY PVC CONDUIT W/ 3/8" MIN PULL ROPE, ±60'
-INSTALL 2 RUNS OF 350 UG TPX, ±100'
HH1 - M01
-CUSTOMER INSTALL 3" SCH-40 GREY PVC CONDUIT W/ 3/8" MIN PULL ROPE, ±30'
-INSTALL 350 UG TPX IN CUSTOMER-PROVIDED CONDUIT, ±50'
ARE TO BE INSTALLED, CROSS SECTION DETAILS OF THE TYPICAL EROSION
STRUCTURES, & SPECIAL REQUIREMENTS FOR WORK IN SENSITIVE AREAS.)
EROSION & SEDIMENT CONTROL REQUIREMENTS
NOTES DETAILING WHERE EROSION OR SEDIMENT CONTROL STRUCTURES
(LOCAL JURISDICTIONS MAY HAVE ADDITIONAL REQUIREMENTS INCLUDING
0150.3200 TECHNIQUES FOR TEMPORARY EROSION & SEDIMENT CONTROL
EROSION & SEDIMENT CONTROL SHALL BE PER PSE STANDARD PRACTICE
& ANY ADDITIONAL LOCAL JURISDICTION REQUIREMENTS.
CIRCUIT LOADING TABLE
AS OF
EXIST. PEAK LOAD
EST. NEW LOAD
TOTAL
CIRCUIT:
A PHASE B PHASE C PHASE
HIG-15
6/13/17
347 78 161
-2.63 -
347 80.63 161
OVERHEAD CIRCUIT MAP ‒ 2405E136
SCALE: 6" = 1 MILE
32"
Typical
24"
Min
24"-36"
24"-36"
4'Top View
Electric & Joint Utility
Work Pit Dimensions
36"
Min
Drainage Pipe
12" Minimum Clearance
from Gas Service Lines
Conduit Depth
24" to 36" Max
Regulator Vent
Gas Meter Assembly
Utility Provided
48"
4'8"
Service (Permanent Detail:)
Not to Scale
Seal
Conduit
Ends
Closed
4'8"
24" Min
36" Typical
3'
To Trench
Property Line
Conduit Stakes
Customer Provided
3" Schedule 40 Grey PVC
Power Cable Conduit
Customer Provided
Gas Service Line Conduit
Sch 40 White PVC
Customer Provided
3" Conduit Service Riser
Customer Provided
Elec. Mtr Base
Elec Mtr
utility provided
Gas Meter
Relief Vent
Building Wall
Elec. Mtr
SCALE: NONE
METER DETAIL @ M01
Removed at site:
Grid Number:
kVA Rating:
Foreman to redline the following information
TRANSFORMER REMOVAL
Company ID#:
Primary phase connected to:
Tested Secondary Voltage
P01
319229-166201
50
Installed at site:
Grid Number:
kVA Rating:
Foreman to redline the following information
TRANSFORMER INSTALLATION
Company ID#:
Primary phase connected to:
Tested Secondary Voltage
Material ID#:
P01
319229-166201
75
6211400
LRC:
% V. Drop:
% Flicker:
Sq. Footage:
Panel Size:
Heat Type:
Est. Demand:
3,500 SQ. FT.
200 AMPS
GAS
9 KW
115 AMPS
3.7%
2.9%
CIRCUIT FEET ADDED: 0
SECONDARY ONE-LINE DIAGRAM
SCALE: NONE
CUSTOMER-SUPPLIED SERVICE TRENCH
TV & TEL Electric Service Cable in Conduit
3" Schedule 80 Grey PVC in ROW
Final Grade
24" Min
24" Min
to
36" Max
Cover Separation
12" Min
20" Min
JOINT TRENCH DETAIL
Electric Service Cable in Conduit (NTS)
To Excavated Dirt Pile
36" MINIMUM COVER
IN RIGHT OF WAY
Backfill for Conduit
Free of rocks
larger than 8"
in diameter)
Backfill for In Conduit - The backfill layer shall be soil that is free from construction debris,
glass, sharp rocks, frozen clods, and rocks larger than 8" in diameter.
Excavated Dirt Pile
Customer's
service
conductors
Captive L-Bolt
27-1/4"
2"
18"
Captive L-Bolt
Lock Cover, 10 lbs
40-1/2"
Conductors enter from
beneath and shall be
folded back with handhole
SIDE VIEW
Lock Cover
30"
Approx
Approx
17"
Set handhole flush
to final grade
SINGLE PHASE SECONDARY HANDHOLE
Not to scale 6050.2000
3" Schedule 40 Grey PVC in Private Property
Project Location