HomeMy WebLinkAboutP_Design_105086706_V1_171110WORK ZONE WORK ZONE J 3600VERIZONE VALLEY HWY316636-165776 316622-165788 T80 316654-165789 T79 316657-165778 SL1018852 316624-165777 SL1018722 316636-165787 50 kVA 120/240V (A) 75kVA 120/240V (A) SITE PLAN N Vicinity Map N/A Owner / Developer Contact Info officeATTN: VERIZON WIRELESS PO BOX 2375 SPOKANE, WA 99210 Amber Kerr (360) 438-8002 SITE SPECIFIC NOTES OVERHEAD CIRCUIT MAP (2305E124) SCALE: 6" = 1 MILE ARE TO BE INSTALLED, CROSS SECTION DETAILS OF THE TYPICAL EROSION STRUCTURES, & SPECIAL REQUIREMENTS FOR WORK IN SENSITIVE AREAS.) EROSION & SEDIMENT CONTROL REQUIREMENTS NOTES DETAILING WHERE EROSION OR SEDIMENT CONTROL STRUCTURES (LOCAL JURISDICTIONS MAY HAVE ADDITIONAL REQUIREMENTS INCLUDING 0150.3200 TECHNIQUES FOR TEMPORARY EROSION & SEDIMENT CONTROL EROSION & SEDIMENT CONTROL SHALL BE PER PSE STANDARD PRACTICE & ANY ADDITIONAL LOCAL JURISDICTION REQUIREMENTS. FOREMAN (CHECK BOX WHEN COMPLETED) PSE Equipment LOCKED/SECURED & Work Area left in CLEAN/SAFE Condition. Grid, Cable, and Switch numbers INSTALLED & VERIFIED. Field Changes RED-LINED on As-built. Indicate correct FUSE SIZE on As-built & VERIFY proper PHASE. Foreman's Signature _______________________________________________ Print Name ___________________________________ Date ______________ Material VERIFIED and CHANGES noted on Paperwork. Total PRIMARY Cable noted on As-built. Company ID#'s RECORDED in correct location on As-built. Deviations noted on the As-built and their reason. I certify that the work performed meets PSE's standards and procedures and that all quality requirements are met. CIRCUIT LOADING TABLE AS OF EXIST. PEAK LOAD EST. NEW LOAD TOTAL CIRCUIT: A PHASE B PHASE C PHASE VIC-16 6/13/17 239 196 226 .98 -- 239.98 196 226 GAS PHONE CABLE TV N/A 101108383 N/A 108103292 N/A 583057976 505051718 104297057 N/A N/A N/A N/A N/A PROJECT PHASE PWR NOTIF#ORDER# Superior HH Replacement HH Removal TRF Removal Service Connection Job Order Distribution HP Svc/MSA POWER GENERAL NOTES - COMMERCIAL PROJECT 8. EXCAVATION: The customer is to provide all trenching, backfill, vault excavations, compaction and restoration per this sketch and per PSE standards. A minimum protective cover of 36" is required over PSE's primary voltage equipment and 24" is required of PSE's secondary voltage equipment. The customer will provide any and all shoring or they will side slope the trench to 1:1. All materials to be installed in accordance with Puget Sound Energy's (PSE) standards. Any deviation from this work sketch must be AUTHORIZED by PSE's Project Manager and NOTED on the Foremans' Copy. All switching arrangements and/or outage arrangements are to be made with the Project Manager at least three (3) working days in advance. Contact the Utilities Underground Location Center (1-800-424-5555) at least 48 hours prior to commencing work to get the underground facilities located. STAKING: The customer will provide all staking (transformer, handhole, trench, grade, lot, pole, sidewalk, etc.). See sketch and details for locations. Equipment locations must be approved by the Project Manager. SITE PREPARATION: The work area will be at or near finished grade, clear of trench spoils or construction materials which would restrict construction and/or equipment access, before work can begin. Roads shall be paved or have a compacted , crushed rock base in place. CLEARANCES: Transformers require a minimum of 6 feet from fire fighting equipment, 10 feet from combustible walls, overhangs, doors, and windows, and a minimum of 5 feet from the back of curb (or guard posts will be required per PSE standards). All conduits and vaults are to be at least 5 feet away from water, storm and sewer lines when paralleling them in the right of way, and at least 1 foot when crossing them. All work is to be done in accordance with local municipal and county permit requirements as applicable. Customer/Developer is responsible to provide, install and maintain all secondary service cables, conduits and crossings from the individual unit's meter base to the designated connection point. Inclement weather conditions may cause delays in construction times and dates. 1. 2. 3. 4. 5. 6. 7. 9. 11. 10. PSE No No No Yes Yes Yes No YesDeveloper "Flagging Required" "Outages Required" "Locates Required" X X X X E-Mail: Cell Phone: Project Manager Contact Information: Manager:Val Buzunov (425) 457-9938 VAL.BUZUNOV@PSE.COM SCALE: 1" = 50'105086706THIS SKETCH NOT TO BE RELIED UPON FOR EXACT LOCATION OF EXISTING FACILITIES CALL 811 TWO BUSINESS DAYS BEFORE YOU DIG For contacts below dial 1-888-CALL PSE (225-5773) UTILITIES CONTACT PHONE# COUNTY 1/4 SEC U-MAP NO (POWER) OP MAP Emer Sect Gas Wk Ctr POWER WK CTR PLAT MAP JOINT FACILITIES ARRANGEMENTS DRAWN BY CHECKED BY APPROVED BY FOREMAN #1 FOREMAN #2 MAPPING INCIDENT MAOP Gas Order Elect Order SCALE PAGE ENGR - POWER ENGR - GAS FUNCTION PROJECT MGR PERMITREAL ESTATE/EASEMENT 2 1 REV# 3 DATE DESCRIPTIONBY CONTACT PHONE NO DATE OH CKT MAP CIRCUIT NOUG CKT MAP Val Buzunov (425) 457-9938 10/24/17 Nate Linville (253) 970-7284 10/24/17 N/A N/A N/A Nate Linville (253) 970-7284 N/A City of Renton Verizon SEA Teasdale TRF Upgrade REPL 1Ø 120/240V PM TRF, REPL SEC HH, CONN SVC 3600 EAST VALLEY RD, RENTON, WA 98057 N/A N/A N/A 105086706 AS NOTED 1 OF 1 KING N/A N/A CSPSKEPM SE-30-23-05E N/A N/A 2305E120 2305E124 2305E120 VIC-16 N/A N/A N/A N/A N/A N/A N/A N/A N/A N/A N/A N/A N/A N/A N/A N/A N/A N/A N/A N/A N/A Service Stubs 105086706 N/A N/A 504967927 N/A CIRCUIT FEET ADDED: 0 LRC: % V. Drop: % Flicker: Sq. Footage: Panel Size: Heat Type: Est. Demand: 0 SQ. 200 AMPS NONE 6KW 65A 1.7% 0.6% SW 41ST ST SW 34TH ST AT V01: EXISTING EXISTING 42" X 36" MP HAND HOLE TO REMAIN REMOVE EXISTING 50kVA 120/240V PM TRANSFORMER AND RETURN TO PSE YARD -INST. 1 - 4" 48" X 48" SPLIT RISER W/22" X 26" ACCESS HOLE (MID: 9998565) -INST. 1 - 75kVA 120/240V PM TRANSFORMER RECONNECT EXISTING SECONDARY CONNECTION BLOCKS AT HH1: REPACE CUSTOMER TO EXCAVATE AROUND EXISTING SECONDARY HAND HOLE EXISTING B/O CONCRETE HAND HOLE TO BE REMOVED -INST. 1 - 2'8" X 3'8" CONCRETE HAND HOLE W/STD PLATE LID PER STD 6050.2020 (HH16500SP) -INST. 3 - 6POS #6 - 500KCMIL SECONDARY CONNECTION BLOCKS PER STD 6050.2020 (MID: 7651001) CONNECT AND TAG 1 - RUN CUSTOMER INSTALLED, OWNED, MAINTAINED 250KCMIL TPLX SVC PSE METER DEPARTMENT TO SET CL20 METER FOREMAN NOTE PM TO COORDINATE OUTAGES GATE CODE 7011 DEVELOPER & CUSTOMER NOTES: THE CUSTOMER IS RESPONSIBLE FOR PROVIDING ALL TRENCHING, SELECT BACKFILL, COMPACTION & RESTORATION PER PUGET SOUND ENERGY STANDARDS 6750.6500 -REQUIRED TO PROVIDE 6' X 7' WORK PIT & 1 CUBIC YARD OF 5/8" MINUS AT HH1 -REQUIRED TO FOLLOW ALL TRENCH DETAILS ON SELECT BACKFILL -REQUIRED TO PROVIDE EQUIPMENT TO PUMP OUT WATER FOR WORK PITS & TRENCH AT ALL TIMES -EXCAVATE & EXPOSE EXISTING PSE UG FACILITIES 48 HOURS PRIOR TO CONSTRUCTION -PSE INSPECTION IS REQUIRED PRIOR TO FINAL BACKFILL -PSE WILL NOT ENERGIZE FACILITIES UNTIL BACKFILL IS COMPLETE -L&I INSPECTION & APPROVAL IS REQUIRED 72 HOURS PRIOR TO CONNECTION -RESPONSIBLE FOR ALL TREE TRIMMING AND BRUSH CLEARING AT HH1 - SINGLE PHASE SECONDARY CONCRETE HANDHOLE Not to scale 6050.2020-2 Steel Door Handhole 1900 lbs Typical customer run service conductors in duct Seal conduit with foam Install PVC bell ends and grout into wall Conduits and conductors shall enter from ends of handhole through knockouts provided TOP VIEW SIDE VIEW 3'-4" EXCAVATION: 5-1/3 CUBIC YARDS 7'-0" 6'-0" 6" Crashed rock 2" Customer-installed grounding wires ( the "4th" wire on the single-phase systems and the "5th" wire on the three-phase systems) shall not be connected to PSE's ground or neutral bus. They shall be removed by customer or cut off at the vault wall. Installed at site: Grid Number: kVA Rating: Foreman to redline the following information TRANSFORMER INSTALLATION Company ID#: Primary phase connected to: Tested Secondary Voltage Material ID#: V01 316636-165787 75kVA 6247150 Removed at site: Grid Number: kVA Rating: Foreman to redline the following information TRANSFORMER REMOVAL Company ID#: Primary phase connected to: Tested Secondary Voltage V01 316636-165787 50kVA UNDERGROUND CIRCUIT MAP (2305E120) SCALE: 1" = 50'