Franchise Permit: MFP17005837
IVR Number: 17005837
Permit Informa!on
Permit Name:Puget Sound Energy - Electric
Address/Loca!on:12/04/2017Applica!on Date:1523059002Parcel Number:4815 NE 4TH ST
Permit Type :12/20/2017Issue Date:Franchise
Permit Work Class:12/20/2018Expira!on Date :Minor U%lity
Job Number:105080428Franchise Type :Electric
Descrip!on:Install 3 phase commercial primary line extension . Reframe pole and pull new UG primary in exis%ng conduit .
Restora%on per City of Renton standards .
Contacts
Name Address PhoneTypeBilling
ANISH KUMAR
PUGET SOUND ENERGY - ELECTRIC - BILLING
6905 S 228th St
Kent, WA 98032
B: (253) 208-2183Applicant
Vicki Henson
Potelco Inc
8001 212th St S
Kent, WA 98032
B: (253) 863-0484Contractor
Business License Number: BL.005109Electrical Contractor : POTELI*344O4
Construc!on Contractor : POTELI*227PL
CITY OF RENTON ROW 1055 S Grady Way
Renton, WA 98057-3232
Owner
ANISH KUMAR
PUGET SOUND ENERGY - ELECTRIC - BILLING
6905 S 228th St
Kent, WA 98032
B: (253) 208-2183Specialized
Billing
X
General Condi!ons & Signature
Permission is hereby given for the work described on this permit according to the conditions hereon and according to the
approved plans and specifications pertaining thereto, subject to compliance with the Ordinance of the City of Renton.
This permit and plans must be posted at the job site at all times.
I hereby certify that no work is to be done except as described above and in approved plans, and that work is to conform to
Renton Trench Restoration and Street Overlay Requirements.
Call (425) 430-7203 or go to: www.MyBuildingPermit.com one working day in advance to schedule an inspections and for ANY
work in the Right of Way.
Call 8 1 1 to locate underground utilities at least two full business days prior to any excavation.
In accordance with RCW 19.122.033(4) the permit holder is required to contact (Williams Northwest Pipeline at 425.868.1010)
(Olympic Pipeline at 206.510.0575)(Puget Sound Energy at 425.457.5816) to request a consultation with the transmission
pipeline company prior to performing any construction or excavation activities. This requirement to consult with the
transmission pipeline company is in addition to the requirement to Call before You Dig as required in RCW 19.122.
(Date)(Signature)
Page 1 of 1THIS PERMIT AND PLANS MUST BE POSTED AT THE JOB SITE AT ALL TIMES
DEPARTMENT OF COMMUNITY
AND ECONOMIC DEVELOPMENT
Page 1 | Published: 3/30/2017
Planning Division | 1055 South Grady Way, 6th Floor | Renton, WA 98057 | 425-430-7200
Email: franchisepermits@rentonwa.gov Website: rentonwa.gov
FRANCHISE PERMIT APPLICATION
Published: 3/30/2017
TO THE APPLICANT: Submit an electronic copy of the plans with the Franchise Permit Application and the
Traffic Control Application to franchisepermits@rentonwa.gov. Permit cost is $360.50. Inspection fee for
trenching more than 60 lineal feet or installation of 6 or more poles will be billed at $60.00 per hour.
Franchise Agency:
Franchise Job Number: Phone:
Contact Name: Email:
Job Site Address: Project Name:
Description of Work:
Please check all that apply:
☐ New Construction ☐ Repair/Relocate ☐ Underground ☐ Overhead ☐ Sidewalk ☐ Street
☐ Open Trench ☐ Bore # of feet:
Contractor Name: Phone:
State Contractors License #: City of Renton Business License #:
“I certify that I am the owner or applicant’s authorized agent and do hereby agree to abide to the terms and conditions set forth under this permit and shall comply with the City of Renton’s Trench Restoration and Street Overlay Requirements. ”
Signature Date
INSPECTIONS SHALL BE REQUESTED 24 HOURS PRIOR TO COMMENCEMENT OF ALL WORK BY CALLING THE
INSPECTION LINE AT 425-430-7203 OR BY GOING TO MYBUILDINGPERMIT.COM
Jobs are required to be called in for job start, re-inspection and project final. Re-inspection fees are billed at $75/hour.
All Pre-Construction meetings shall be scheduled at a maximum of 14 days prior to the job start date.
Plan Review/Development Engineering Date Approved as submitted
Pre-Construction Meeting required
Site Construction Inspector Date Approved with comments or redlines
Camera inspection of utilities required
Development Engineering Manager Date
Puget Sound Energy - Electric
105080428
Anish Kumar
253-208-2183
anish.kumar@pse.com
4815 NE 4th St Renton MINI LLC
Install 3 phase commercial primary line extension. Crew will need to occupy W
bound shoulder of NE 4th St to reframe pole and pull new UG primary in existing conduit.
Restoration per City of Renton standards.
Potelco Inc.253-208-2183
BL005109 Poteli*227PL
12/04/2017
MFP17005837
Scott Warlick 12/11/2017
Justin Johnson 12-19-2017
CITY OF RENTON
TRAFFIC CONTROL PLAN
PROJECT NAME: PERMIT#
CONSTRUCTION COMPANY: PHONE#:
CONTACT NAME: PHONE#:
ADDRESS: CELL#:
E-MAIL ADDRESS: FAX#:
PROJECT LOCATION: N/E/S/W OF:
WORK TIME: APPROVED BY:
WORK DATE: APPROVAL DATE:
OFFICE COPY T-
CONTRACTOR
DEV. SERVICE, INSPECTION P. MILLER
DEV. SERVICE, PLAN REVIEW B. BANNWARTH
POLICE CHARLES KARLEWICZ
FIRE FIRE MARSHALL FS #13
Permit Holder agrees to all the following:
• Comply with all traffic regulations of the City of Renton and the State of Washington.
• Prepare a traffic control plan and obtain City approval of that plan. That plan shall be implemented for
all street and lane closures, and the plan shall be performed in compliance with the Manual on
Uniform Traffic Control Devices.
• Notify emergency services (253-852-2121) twenty-four (24) hours before any street or lane closures.
• Any lane or street closures not in conformance with the approved traffic control plan and/or without
notification of emergency services may result in receiving a citation for violation of R.C.W. 47.36.200
through 47.36.220, 9A.36.050 Reckless Endangerment, and other applicable State and City codes.
• Indemnify and hold harmless the City of Renton from any and all claims, actions, and judgments,
including all costs of defense and attorney’s fees incurred in defending against same, arising from and
related to implementation of the approved traffic control plans including claims arising from towing of
private vehicles and the acts of the Permit Holder’s agents and employees.
• The City of Renton shall be entitled, in its reasonable discretion, to settle claims prior to suit or
judgment, and in such event shall indemnify and hold harmless the City for any such claims paid,
including the City’s reasonable attorney’s fees and litigation costs incurred resulting from such claim.
• In the event any claim or suit is brought against City within the scope of this Agreement, Permit Holder
will pay for legal counsel chosen by the City to defend against same.
• Flagger and sign placement are subject to revision by the City Inspector on site, if needed to address
traffic or pedestrian safety or travel.
• By my signature herein, I acknowledge all the above requirements.
PRINT NAME: DATE:
SIGNATURE:
Reset FormPrint Form
Renton MINI LLC
PSE/Potelco Inc.
Marc Bayley 253-259-4494
6905 S 228th St, Kent, WA 98032
marcus.bayley@pse.com
4815 NE 4th St
Evening (will call in or MBP)
TBD
Anish Kumar 12/04/2017
MFP17005837
Justin Johnson
12-19-2017Monday through Friday
9:00 am to 3:00 pm
SKETCH
I
-- NORTH --
I
NOTES:
• Work Zone Traffic Control shall be in accordance with the Manual on Uniform Traffic Control Devices (MUTCD)
and shown by sketch or reference to WSDOT.
• The plan must be submitted to the City’s PW/Transportation Division for review and/or approval at least three
working days prior to work.
• Approved Temporary Traffic Control Plan must be at the work site during work hours.
• Contractor or entity must call Renton School District (425-204-4455) or any public/private agency to be affected
by a temporary lane or road closure.
• Complete assistance and accommodation shall be provided to all kinds of pedestrian traffic when sidewalk or
walkway is impeded.
• Total road closure lasting more than 24 hours is subject to the approval by the City Council.
• Any vehicle, equipment, barricade, or portable tow-away sign used within the work area must display a
company logo or any legally acceptable sign showing the company name, address, and telephone number at a
conspicuous place on the vehicle or equipment.
In the case of Temporary No Parking Zones, all the following apply in addition to previous:
• Contractor must complete form to show limits of Temporary No Parking Zone identifying barricade locations for
vacate parking or curb lane usage.
• Contractor must post notice of dates and time of Temporary No Parking Zone with at least two signs per block
72 hours in advance of effective date and time.
• The cover sheet of this Traffic Control Plan form must be attached to each Temporary No Parking Sign on the
project site.
• Temporary traffic control devices must be removed immediately when work is done or no construction activities
are going on. If deemed abandoned, City crews will remove and store them at the City’s maintenance shop
(3555 NE 2nd Street).
PROJECT
PROJECT
LOCATION
TRAFFIC FLOW
PERM LANE MARKINGS
TAPERS / TANGENTS
PROTECTIVE VEHICLE
W/BEACON
TRUCK-MOUNTED
ATTENTUATOR
PORTABLE TRAFFIC
SIGNAL
SLOW
VMS12
LEGEND
FLAGGER
OFFICER
SURVEYORS
WORK SPACE
UTILITY WORK
CONSTRUCTION
DEVICES
SIGNS
BARRICADES
ARROW BOARD
ARROW MODE
ARROW BOARD
CAUTION MODE
PCMS
/ VMS
TEMPORARY TRAFFIC CONTROL PLAN
Not Drawn to Scale
This sketch not to be relied upon for exact location of utilities.
CALL (800) 424-5555 TWO BUSINESS DAYS BEFORE YOU DIG
PERMIT
DRAWING NOT
TO SCALE
Drawn by: D Sandall - WA TCS Certificate # 8957, OR TCS Certificate # 5107
425-923-0010
4/8/2016
1 of
City of Renton
WORK HOURS
LANE WIDTH
POSTED SPEED
MERGE TAPER (L)
BUFFER
SIGN SPACING
DEVICES TAPERS
DEVICES TANGENT
10-20 ft
X
60FT
8am to 5pm
!Work from P01 to V01
11ft
4815 NE 4th St
Yes No
Traffic Control Supervisor(TCS) X
Flaggers/Spotters X
Uniformed Officer X
225ft
1
35mph
Dana M Smith
dana.smith@pse.com
101097081
Boris Sidorov-PSE
Boris.Sidorov@pse.com
105080869
David Goodale
david.goodale@pse.com
105080428
Dianne Alexander
Dianne.Alexander@pse.com
101098429
250ft
350ft
MFP17005837
SSSSSAASSTTTSSSSSSSSSUP UPUP318090-167369300kVA 277/480v100TXT76888210'55'35'MAP17FEEDJOB SITE210'55'35'4'x4'WORK PIT8'x8'WORK PITPOTELCO TO INSTALL 1-4" SCH'L 80 CONDUIT, ±300'INSTALL 1 RUN OF 3Ø 1/0 AL JKT PRI CABLE, ±355'(EHC802-AØ, EHC803-BØ, EHC804-CØ)SITE PLANOwner / Developer Contact InfoofficeATTN:RENTON MINI LLC.918 S HORTON ST. #1000SEATTLE, WA 98134TRAVIS AMECHE(425)213-4000105080428THIS SKETCH NOT TO BE RELIED UPON FOR EXACT LOCATION OF EXISTING FACILITIESCALL (800) 424-55552 BUSINESS DAYS BEFORE YOU DIGFor contacts below dial 1-888-CALL PSE (225-5773)OVERHEAD CIRCUIT MAPSCALE: 6" = 1 MILEARE TO BE INSTALLED, CROSS SECTION DETAILS OF THE TYPICAL EROSIONSTRUCTURES, & SPECIAL REQUIREMENTS FOR WORK IN SENSITIVE AREAS.)EROSION & SEDIMENT CONTROL REQUIREMENTSNOTES DETAILING WHERE EROSION OR SEDIMENT CONTROL STRUCTURES(LOCAL JURISDICTIONS MAY HAVE ADDITIONAL REQUIREMENTS INCLUDING0150.3200 TECHNIQUES FOR TEMPORARY EROSION & SEDIMENT CONTROLEROSION & SEDIMENT CONTROL SHALL BE PER PSE STANDARD PRACTICE& ANY ADDITIONAL LOCAL JURISDICTION REQUIREMENTS.FOREMAN (CHECK BOX WHEN COMPLETED)PSE Equipment LOCKED/SECURED & Work Area left in CLEAN/SAFE Condition.Grid, Cable, and Switch numbers INSTALLED & VERIFIED.Field Changes RED-LINED on As-built.Indicate correct FUSE SIZE on As-built & VERIFY proper PHASE.Foreman's Signature _______________________________________________Print Name ___________________________________ Date ______________Material VERIFIED and CHANGES noted on Paperwork.Total PRIMARY Cable noted on As-built.Company ID#'s RECORDED in correct location on As-built.Deviations noted on the As-built and their reason.I certify that the work performed meets PSE's standards and procedures and that all quality requirements are met.CIRCUIT LOADING TABLEAS OFEXIST. PEAK LOADEST. NEW LOADTOTALCIRCUIT:A PHASE B PHASE C PHASEMAP-172015186196186+9+9+9195205195GASPHONECABLE TV501272328105080428N/AN/AN/AN/AN/AN/APROJECT PHASEPWRNOTIF#ORDER#SuperiorDistributionHP MainHP Svc/MSADESIGNED BYUTILITIESCONTACTPHONE#COUNTY1/4 SECU-MAP NO (POWER)OP MAPEmer SectGas Wk CtrPOWER WK CTRPLAT MAPJOINT FACILITIES ARRANGEMENTSDRAWN BYCHECKED BYAPPROVED BYFOREMAN #1FOREMAN #2MAPPINGINCIDENTMAOPGas OrderElect OrderSCALEPAGEENGR - POWERENGR - GASFUNCTIONPROJECT MGRPERMITREAL ESTATE/EASEMENT21REV#3DATEDESCRIPTIONBYCONTACTPHONE NODATEOH CKT MAPCIRCUIT NOUG CKT MAPVIC IBARRA425-429-457402/05/16VIC IBARRA425-429-457402/05/16N/AN/AN/AJ. REIBMAN253-437-679802/05/16REQUIREDCITY OF RENTONRENTON MINI LLC.INSTALL 3Ø PRIMARY LINE EXTENSION4815 NE 4TH ST, RENTON WA 98059PSEN/AN/AN/A105080428AS NOTED1/1KINGN/AN/ACSPSKEINT23N, R05E, NW SEC 15N/AN/A2305E0582305E0882305E058MAP-17N/AN/AN/AN/AN/AN/AN/AN/AN/AN/AN/AN/APOWER GENERAL NOTES - COMMERCIAL PROJECT8.All materials to be installed in accordance with Puget Sound Energy's (PSE) standards. Any deviation fromthis work sketch must be AUTHORIZED by PSE's Project Manager and NOTED on the Foremans' Copy.All switching arrangements and/or outage arrangements are to be made with the Project Manager at leastthree (3) working days in advance.Contact the Utilities Underground Location Center (1-800-424-5555) at least 48 hours prior to commencingwork to get the underground facilities located.STAKING: The customer will provide all staking (transformer, handhole, trench, grade, lot, pole, sidewalk,etc.). See sketch and details for locations. Equipment locations must be approved by the Project Manager.SITE PREPARATION: The work area will be at or near finished grade, clear of trench spoils or constructionmaterials which would restrict construction and/or equipment access, before work can begin.Roads shall be paved or have a compacted , crushed rock base in place.CLEARANCES: Transformers require a minimum of 6 feet from fire fighting equipment, 10 feet fromcombustible walls, overhangs, doors, and windows, and a minimum of 5 feet from the back of curb (or guardposts will be required per PSE standards). All conduits and vaults are to be at least 5 feet away from water,storm and sewer lines when paralleling them in the right of way, and at least 1 foot when crossing them.All work is to be done in accordance with local municipal and county permit requirements as applicable.Customer/Developer is responsible to provide, install and maintain all secondary service cables, conduitsand crossings from the individual unit's meter base to the designated connection point.Inclement weather conditions may cause delays in construction times and dates.1.2.3.4.5.6.7.9.10.PSENoNoNoYesYesYesNoYesDeveloper"Flagging Required""Outages Required""Locates Required"E-Mail:Cell Phone:Project Manager Contact Information:Manager:VIC IBARRA425-429-4574victor.ibarra@pse.comNVicinity MapSCALE: 1"=50'SITE SPECIFIC NOTESAT P01: GRID#218112-167360- EXISTING POLE AND EQUIPMENT TO REMAIN,167$//$/8035,0$5<7(5021)*75,81,7- INSTALL (3) L/B C/O's & SURGE ARRESTERS, FUSE @ 100T- INSTALL SW #T76888- INSTALL (3) STIRRUPS- INSTALL 4" PRIMARY RISER ON EXISTING S/O BRKTSAT V01: GRID#218090-167369- INSTALL 4'-8" SQ VAULT w/ 4'-8" x 5'-6" COVER- INSTALL 300KVA THREE-PHASE PM TRF 277/480v- INSTALL (3) L/B ELBOWS- INSTALL (3) 4POS SECONDARY CONNECTORS- CONNECT & TAG CUSTOMER RAN UG SVC LINES (2 RUNS OF 250MCM AL)- INSTALL GRID #218090-167369SPAN NOTESP01 TO V0136(72,167$//
6&+
/*5$<39&&21'8,736(72,167$//
2)5812)$/-.735,0$5<&$%/((+&$(+&%(+&&CIRCUIT FEET ADDED: 300'@ TRANSFORMER% V. Drop (240v): 2.4%% Flicker (120v): 0.5%% Flicker (240v): 2.8%SQ. FOOTAGE: 63,740 SQPANEL SIZE: 400 AMPEXISTING LOAD: 0 KWNEW LOAD: 165 KWTOTAL LOAD: 165 KWLRC: 205 AMPTOP VIEWExcavation - 10-1/3 cubic yardsSIDE VIEWRockCrushed6"4'-4"2"8'8'4'-8"3'-6"4'-8"6"20"4'-8"5'-6"44"Not to scale6045.5000-13,600 lbs1,657 lbsVAULT & EXCAVATION DETAILCommunicationsPrimary PowerCables or ConduitExcavated Dirt PileROADSIDEFinal Grade24" Min4" MinSeparation36"MinCover48"MaxBackfill(No rocks over 10" diameter)Separation12" MinGas4" Sand Bedding32" Typical(Power, Gas, andCommunications)JOINT TRENCH DETAILPrimary-Mainline Gas & Communications (NTS)Separation12" Min6" or 12" Min Sand Shading after Compaction- A 6" layer of sand is allowed when excavated native material contains rocks no larger than 8" in diameter.Trench and backfill requirements for primary electric line extension trenches (No PSE gas)- A 12" layer of sand is required when excavated native material contains rocks up to 10" in diameter.Standoff Bracket15" Min LengthConduit ClampConduitField FaceQuadrantClimbingSpaceRoad FaceQuadrantClimbingSpace5" MinCLLCDirection of Vehicular TrafficCONDUIT RISER PLACEMENT DETAILTOP VIEWNot to ScaleInstalled at site:Grid Number:kVA Rating:Foreman to redline the following informationTRANSFORMER INSTALLATIONCompany ID#:Primary phase connected to:Tested Secondary VoltageV01318090-167369300kVAPRIMARY CABLE & CONDUIT TABLELOCATIONCONDUITPRIMARY CABLEASBUILT INFORMATIONSIZEQtyLENGTHDesign(ft)BENDSPULLPULLCableLENGTHDesign(ft)Cable NumbersPlease RecordForeman - CompleteFROMTO(in)90°45°22°11°(lbs)Rev(lbs)SizeABCManufacturerCompoundYearActual Amount Installed (Conduit & Cable)P01V01412952353.6527.71/0 AL JKT350EHC802353.6527.71/0 AL JKT350EHC803353.6527.71/0 AL JKT350EHC804JOB SITECABLE & CONDUIT ONE-LINE DIAGRAMSCALE: NOT TO SCALEDEVELOPER CIVIL CONTRACTOR NOTES:- REQUIRED TO PROVIDE AN 8' x 8' WORK PIT AT THE 3 PHASE TRANSFORMER VAULT (V01).- REQUIRED TO PROVIDE A 4' x 4' WORK PIT AT EXISTING POLE (P01).- REQUIRED TO PROVIDE 6" OF CRUSHED ROCK FOR 3 PHASE VAULTS- REQUIRED TO PROVIDE AND HAVE EQUIPMENT TO PUMP OUT WATER FOR METER BASE PITS &TRENCH AT ALL TIMES.CUSTOMER IS RESPONSIBLE FOR ALL TRENCHING, SELECT BACKFILL, COMPACTION &RESTORATION PER PUGET SOUND ENERGY STANDARDS #6750.6500.**DEVELOPER NEEDS TO FOLLOW ALL TRENCH DETAILS ON SELECT BACKFILL**PSE TO PROVIDE CONDUITS:- PSE TO PROVIDE 3/8" POLY RATED 1,800LBS PULL ROPE IN ALL CONDUITS.DEVELOPER EXCAVATION SPLICE NOTES:- REQUIRED TO EXCAVATE & EXPOSED EXISTING PSE UG FACILITIES 48 HOURS BEFORECONSTRUCTION.- ALL EQUIPMENT MUST BE PROTECTED FROM VANDALS WITH STEEL PLATES 48 HOURS BEFORECONSTRUCTION.- EXCAVATION MUST BE COMPLETED 48 HOURS PRIOR TO CONSTRUCTION.- REQUIRED TO HAVE EXCAVATION EQUIPMENT ON SITE THE DAY OF CONSTRUCTION TO COMPLETE%$&.),//,1*)257+(8*35,0$5<63/,&(6 ,167$//$7,212)7+(259$8/7- BACKFILL / COVER REQUIRED ON PRIMARY.CONTRACTOR TRENCHING IN CITY OR COUNTY OR W.S. DOT RIGHTOF WAY NOTES:- PLEASE REVIEW THE CITY OR KING COUNTY TRENCHING REQUIREMENTS UNDER THE PERMIT.IF A PRE-CON IS REQUIRED BY THE CITY, COUNTY OR W.S. DOT A PSE PROJECT MANAGER WILLSET-UP AND SCHEDULE A MEETING WITH THE MUNICIPALITY BEFORE ANY EXCAVATION ORINSTALLATION BEGINS.ALL INSPECTIONS ARE REQUIRED BY POTELCO INC:- IF A SECOND INSPECTION IS REQUIRED, ADDITIONAL FEE'S WILL BE APPLIED.MFP17005837