HomeMy WebLinkAboutP_Design_101108299_V1_171205PARCEL #1789100010NOP26SE 194TH ST33'63'1924425kVA 120/240v62'CUSTOMER SUPPLIED4' X 4' WORK PITCUSTOMER SUPPLIED1 CUBIC YARD 5/8" CRUSHED ROCKCUSTOMER SUPPLIED4' X 4' WORK PIT3/4" CUBIC YARD SANDCUSTOMER SUPPLIED1-3" SCHED'L 80 PVC CONDUIT ± 30'INST. 1-RUN 350 UG TPX ± 190'CUSTOMER SUPPLIED1-3" SCHED'L 80 PVC CONDUIT ± 100'CUSTOMER SUPPLIED1-3" RED POLY PIPE ± 60'CUSTOMER INSTALLEDPSE SUPPLIEDSITE PLANNVicinity MapN/AOwner / Developer Contact InfoofficeATTN:DAWN THOMPSON12933 SE 46TH LNRENTON, WA 98006DAWN THOMPSON(425) 785-5379ARE TO BE INSTALLED, CROSS SECTION DETAILS OF THE TYPICAL EROSIONSTRUCTURES, & SPECIAL REQUIREMENTS FOR WORK IN SENSITIVE AREAS.)EROSION & SEDIMENT CONTROL REQUIREMENTSNOTES DETAILING WHERE EROSION OR SEDIMENT CONTROL STRUCTURES(LOCAL JURISDICTIONS MAY HAVE ADDITIONAL REQUIREMENTS INCLUDING0150.3200 TECHNIQUES FOR TEMPORARY EROSION & SEDIMENT CONTROLEROSION & SEDIMENT CONTROL SHALL BE PER PSE STANDARD PRACTICE& ANY ADDITIONAL LOCAL JURISDICTION REQUIREMENTS.STANDARD EASEMENT PROVISIONAn easement is hereby reserved for and conveyed to Puget Sound Energy,Inc., Telephone Co., Television Cable Co., and their respective successorsand assigns under and upon the private street(s), if any, and the exteriorten (10) feet of all lots, tracts and spaces with in the plat lying parallel withand adjoining all street(s) in which to construct, operate, maintain, repair,replace and enlarge underground or ground-mounted appurtenancesthereto for the purpose of serving this subdivision and other property withelectric, gas, telephone and other utility service, together with the right toenter upon the streets, lots, tracts and spaces at all times for the purposesherein stated.101108299FOREMAN (CHECK BOX WHEN COMPLETED)PSE Equipment LOCKED/SECURED & Work Area left in CLEAN/SAFE Condition.Grid, Cable, and Switch numbers INSTALLED & VERIFIED.Field Changes RED-LINED on As-built.Indicate correct FUSE SIZE on As-built & VERIFY proper PHASE.Foreman's Signature _______________________________________________Print Name ___________________________________ Date ______________Material VERIFIED and CHANGES noted on Paperwork.Total PRIMARY Cable noted on As-built.Company ID#'s RECORDED in correct location on As-built.Deviations noted on the As-built and their reason.I certify that the work performed meets PSE's standards and procedures and that all quality requirements are met.GASPHONECABLE TV108103272PROJECT PHASEPWRNOTIF#ORDER#SuperiorE-Mail:Cell Phone:Project Manager Contact Information:Manager:DAVE HONEYSETT253-245-0883DAVE.HONEYSETT@PSE.COMPSENoNoNoYesYesYesNoYesDeveloper"Flagging Required""Outages Required""Locates Required"SCALE: 1" = 50'THIS SKETCH NOT TO BE RELIED UPON FOR EXACT LOCATION OF EXISTING FACILITIESCALL 811 TWO BUSINESS DAYS BEFORE YOU DIGFor contacts below dial 1-888-CALL PSE (225-5773)UTILITIESCONTACTPHONE#COUNTY1/4 SECU-MAP NO (POWER)OP MAPEmer SectGas Wk CtrPOWER WK CTRPLAT MAPJOINT FACILITIES ARRANGEMENTSDRAWN BYCHECKED BYAPPROVED BYFOREMAN #1FOREMAN #2MAPPINGINCIDENTMAOPGas OrderElect OrderSCALEPAGEENGR - POWERENGR - GASFUNCTIONPROJECT MGRPERMITREAL ESTATE/EASEMENT21REV#3DATEDESCRIPTIONBYCONTACTPHONE NODATEOH CKT MAPCIRCUIT NOUG CKT MAPD. HONEYSETT253-245-088311/14/17D. HONEYSETT253-245-088311/14/17T. MYER(714) 893-240511/14/17N/ARENTONTHOMPSON RESIDENCESIMPLE SERVICE W/ PERMITS19244 106TH AVE SE, RENTON, WA 98055N/AN/AN/A101108299AS NOTED1 OF 1KINGN/AN/ACSPSKEINNW 5-22N-05EN/AN/A2205E0182205E0362205E018NOP-26N/AN/AN/AN/AN/AN/AN/AN/AN/AN/AN/AN/AN/AN/AN/AN/AN/AN/AN/AN/AN/A101108299505009269SITE SPECIFIC NOTESAT P01: 315938-166204-EXISTING POLE TO REMAIN-EXISTING 25kVA XFMR TO REMAIN-REPLACE EX. GRASSHOPPER CUTOUT W/ NEW CUTOUT (4899000) PER STD 6025.1000-REPLACE EX. FUSE W/ NEW 10T FUSE (3412200) PER STD 6025.1000-INSTALL 3" SEC RISER (RIS3CSS) PER STD 6042.1000-REMOVE EX. OH SVC TO "19244" (TEMP METER)AT M01: NEW METER BASE-INSTALL 200A METERCUSTOMER & DEVELOPER NOTESTHE CUSTOMER IS RESPONSIBLE TO PROVIDE ALL TRENCHING, SELECT BACKFILL, COMPACTION &RESTORATION PER PUGET SOUND ENERGY STANDARDS 6750.65005(48,5('723529,'( ,167$//´6&+('8/(39&&21'8,7)52030 5(48,5('72,167$//5('32/<3,3(3(536(63(&,),&$7,216“ 5(48,5('723529,'( ,167$//´12132/<38//523(,1$//&21'8,76-REQUIRED TO PROVIDE 4' X 4' WORK PIT & 1 CUBIC YARD 5/8" CRUSHED ROCK AT P015(48,5('723529,'(¶;¶:25.3,7 &8%,&<$5'2)6$1'$7M01-REQUIRED TO FOLLOW ALL TRENCH DETAILS ON SELECT BACKFILL-REQUIRED TO PROVIDE EQUIPMENT TO PUMP OUT WATER FOR WORK PITS & TRENCH AT ALL TIMES-REQUIRED TO EXCAVATE & EXPOSE EXISTING PSE UG FACILITIES 48 HOURS PRIOR TO CONSTRUCTION-PSE INSPECTION IS REQUIRED PRIOR TO FINAL BACKFILL-PSE WILL NOT ENERGIZE FACILITIES UNTIL BACKFILL IS COMPLETE-RENTON INSPECTION & APPROVAL IS REQUIRED 5 BUSINESS DAYS PRIOR TO CONNECTIONSPAN SPECIFIC NOTESP01 TO X01:&86720(572,167$//6&+(' /39&&21'8,7“ X01:36(726833/<&86720(572,167$//5('32/<3,3(“ X01 TO M01:&86720(572,167$//6&+(' /39&&21'8,7“ P01 TO M01:,167$//5818*73;&$%/(“  7$,/“ 1.All materials to be installed in accordance with Puget Sound Energy's (PSE) standards. Any deviation from this work sketchmust be AUTHORIZED by PSE's Project Manager and NOTED on the Foremans' Copy.2.All switching arrangements and/or outage arrangements are to be made with the Project Manager at least three (3) workingdays in advance.3.Contact the Utilities Underground Location Center (1-800-424-5555) at least 48 hours prior to commencing work to get theunderground facilities located.4.STAKING: The customer will provide all staking (transformer, handhole, trench, grade, lot, pole, sidewalk, etc.). See sketchand details for locations. Equipment locations must be approved by the Project Manager.5.SITE PREPARATION: The work area will be at or near finished grade, clear of trench spoils or construction materials whichwould restrict construction and/or equipment access, before work can begin.6.Roads shall be paved or have a compacted , crushed rock base in place.7.CLEARANCES: Transformers require a minimum of 6 feet from fire fighting equipment, 10 feet from combustible walls,overhangs, doors, and windows, and a minimum of 5 feet from the back of curb (or guard posts will be required per PSEstandards). All conduits and vaults are to be at least 5 feet away from water, storm and sewer lines when paralleling them inthe right of way, and at least 1 foot when crossing them.8.All work is to be done in accordance with local municipal and county permit requirements as applicable.9.Inclement weather conditions may cause delays in construction times and dates.10.EXCAVATION: The customer is to provide all trenching, backfill, vault excavations, compaction and restoration per thissketch and per PSE standards. A minimum protective cover of 36" is required over PSE's primary voltage equipment and24" is required of PSE's secondary voltage equipment. The customer will provide any and all shoring or they will side slopethe trench to 1:1.POWER GENERAL NOTES - RESIDENTIAL PROJECTCIRCUIT LOADING TABLEAS OFEXIST. PEAK LOADEST. NEW LOADTOTALCIRCUIT:A PHASE B PHASE C PHASENOP-2606/2017211.00208.00287.001.170.000.00212.17208.00287.00OVERHEAD CIRCUIT MAP 2205E036SCALE: 6" = 1 MILECIRCUIT FEET ADDED: 0'SQ. FOOTAGE: 1767 SQ FTPANEL SIZE: 200AHEAT TYPE: ELECTRICEST. DEMAND: 8kWLRC: 80A% V. DROP: 2.7%% FLICKER: 2.6%NEW CABLE & CONDUIT DIAGRAMNOT TO SCALEJOB SITEJOB SITEASPLUNDH CONSTRUCTION CORP.PLACE PEA GRAVELBAGS (MID 9995892)FOR SEDIMENT TRAPPLACE STRAW MULCH ONDISTURBED AREAAUGERED HOLEPOLETYPICAL AUGERED WORK SITE - 0150.3200TECHNIQUES FOR EROSION AND SEDIMENT CONTROLDITCH OR SENSITIVE AREAStandoff Bracket15" Min LengthConduit ClampConduitField FaceQuadrantClimbingSpaceRoad FaceQuadrantClimbingSpace5" MinCLLCDirection of Vehicular TrafficUNDERGROUNDCABLE CONDUITSTO THIS QUADRANTCONDUIT RISER PLACEMENT DETAILSCALE: NONETOP VIEW106TH AVE SE32"Typical24"Min24"-36"24"-36"4'Top ViewElectric & Joint UtilityWork Pit Dimensions36"MinDrainage Pipe12" Minimum Clearancefrom Gas Service LinesConduit Depth24" to 36" MaxRegulator VentGas Meter AssemblyUtility Provided48"4'8"Service (Permanent Detail:)Not to ScaleSealConduitEndsClosed4'8"24" Min36" Typical3'To TrenchProperty LineConduit StakesCustomer Provided3" Schedule 40 Grey PVCPower Cable ConduitCustomer ProvidedGas Service Line ConduitSch 40 White PVCCustomer Provided3" Conduit Service RiserCustomer ProvidedElec. Mtr BaseElec Mtrutility providedGas MeterRelief VentBuilding WallElec. MtrSCALE: NONEMETER DETAIL @ M01TV & TELElectric Service Cable in Conduit3" Schedule 80 Grey PVCExcavated Dirt PileFinal Grade24" Min24" Minto36" MaxCoverSeparation12" Min20" Min JOINT TRENCH DETAILElectric Service Cable in Conduit (NTS)To Excavated Dirt Pile36" MINIMUM COVERIN RIGHT OF WAYBackfill for Conduit Free of rocks larger than 8" in diameter)Backfill for In Conduit - The backfill layer shall be soil that is free from construction debris,glass, sharp rocks, frozen clods, and rocks larger than 8" in diameter.depth as mainline trench conduit.36" Min Cover(38" Max)6"Road crossing must be at samePavementCurbSidewalkR/WROAD CROSSING ELEVATIONNot to scale6790.0075OH TEMP SERVICE / REMOVAL