Loading...
HomeMy WebLinkAboutMFP17005927DEPARTMENT OF COMMUNITY AND ECONOMIC DEVELOPMENT Franchise Permit: MFP17005927 IVR Number: 17005927 Permit Informa!on Permit Name:Puget Sound Energy - Electric Address/Loca!on:12/13/2017Applica!on Date:1523059002Parcel Number:11427 SE 162ND ST Permit Type :12/21/2017Issue Date:Franchise Permit Work Class:12/21/2018Expira!on Date :Minor U&lity Job Number:105086971Franchise Type :Electric Descrip!on:Replace distribu&on pole at P 01 and pull cable across the street at X 01. Pavement cut an&cipated , Restora&on per City of Renton standards . Contacts Name Address PhoneTypeBilling ANISH KUMAR PUGET SOUND ENERGY - ELECTRIC - BILLING 6905 S 228th St Kent, WA 98032 B: (253) 208-2183Applicant Vicki Henson Potelco Inc 8001 212th St S Kent, WA 98032 B: (253) 863-0484Contractor Business License Number: BL.005109Electrical Contractor : POTELI*344O4 Construc!on Contractor : POTELI*227PL CITY OF RENTON ROW 1055 S Grady Way Renton, WA 98057-3232 Owner ANISH KUMAR PUGET SOUND ENERGY - ELECTRIC - BILLING 6905 S 228th St Kent, WA 98032 B: (253) 208-2183Specialized Billing X General Condi!ons & Signature Permission is hereby given for the work described on this permit according to the conditions hereon and according to the approved plans and specifications pertaining thereto, subject to compliance with the Ordinance of the City of Renton. This permit and plans must be posted at the job site at all times. I hereby certify that no work is to be done except as described above and in approved plans, and that work is to conform to Renton Trench Restoration and Street Overlay Requirements. Call (425) 430-7203 or go to: www.MyBuildingPermit.com one working day in advance to schedule an inspections and for ANY work in the Right of Way. Call 8 1 1 to locate underground utilities at least two full business days prior to any excavation. In accordance with RCW 19.122.033(4) the permit holder is required to contact (Williams Northwest Pipeline at 425.868.1010) (Olympic Pipeline at 206.510.0575)(Puget Sound Energy at 425.457.5816) to request a consultation with the transmission pipeline company prior to performing any construction or excavation activities. This requirement to consult with the transmission pipeline company is in addition to the requirement to Call before You Dig as required in RCW 19.122. (Date)(Signature) Page 1 of 1THIS PERMIT AND PLANS MUST BE POSTED AT THE JOB SITE AT ALL TIMES DEPARTMENT OF COMMUNITY AND ECONOMIC DEVELOPMENT Page 1 | Published: 3/30/2017 Planning Division | 1055 South Grady Way, 6th Floor | Renton, WA 98057 | 425-430-7200 Email: franchisepermits@rentonwa.gov Website: rentonwa.gov FRANCHISE PERMIT APPLICATION Published: 3/30/2017 TO THE APPLICANT: Submit an electronic copy of the plans with the Franchise Permit Application and the Traffic Control Application to franchisepermits@rentonwa.gov. Permit cost is $360.50. Inspection fee for trenching more than 60 lineal feet or installation of 6 or more poles will be billed at $60.00 per hour. Franchise Agency: Franchise Job Number: Phone: Contact Name: Email: Job Site Address: Project Name: Description of Work: Please check all that apply: ☐ New Construction ☐ Repair/Relocate ☐ Underground ☐ Overhead ☐ Sidewalk ☐ Street ☐ Open Trench ☐ Bore # of feet: Contractor Name: Phone: State Contractors License #: City of Renton Business License #: “I certify that I am the owner or applicant’s authorized agent and do hereby agree to abide to the terms and conditions set forth under this permit and shall comply with the City of Renton’s Trench Restoration and Street Overlay Requirements. ” Signature Date INSPECTIONS SHALL BE REQUESTED 24 HOURS PRIOR TO COMMENCEMENT OF ALL WORK BY CALLING THE INSPECTION LINE AT 425-430-7203 OR BY GOING TO MYBUILDINGPERMIT.COM Jobs are required to be called in for job start, re-inspection and project final. Re-inspection fees are billed at $75/hour. All Pre-Construction meetings shall be scheduled at a maximum of 14 days prior to the job start date. Plan Review/Development Engineering Date Approved as submitted Pre-Construction Meeting required Site Construction Inspector Date Approved with comments or redlines Camera inspection of utilities required Development Engineering Manager Date Puget Sound Energy - Electric 105086971 Anish Kumar 253-208-2183 anish.kumar@pse.com 11427 SE 162nd St 98055 105086971 One at a time occupying E & W bound shoulders of SE 162nd St for crew to replace distribution pole at P01 and pull cable across the street at X01. Pavement cut anticipated, restoration per City of Renton standards. 20'x4'x42" Potelco Inc.253-208-2183 BL005109 Poteli*227PL 12/13/2017 MFP17005927 Scott Warlick 12/15/2017 Justin Johnson 12-21-2017 CITY OF RENTON TRAFFIC CONTROL PLAN PROJECT NAME: PERMIT# CONSTRUCTION COMPANY: PHONE#: CONTACT NAME: PHONE#: ADDRESS: CELL#: E-MAIL ADDRESS: FAX#: PROJECT LOCATION: N/E/S/W OF: WORK TIME: APPROVED BY: WORK DATE: APPROVAL DATE: OFFICE COPY T- CONTRACTOR DEV. SERVICE, INSPECTION P. MILLER DEV. SERVICE, PLAN REVIEW B. BANNWARTH POLICE CHARLES KARLEWICZ FIRE FIRE MARSHALL FS #13 Permit Holder agrees to all the following: • Comply with all traffic regulations of the City of Renton and the State of Washington. • Prepare a traffic control plan and obtain City approval of that plan. That plan shall be implemented for all street and lane closures, and the plan shall be performed in compliance with the Manual on Uniform Traffic Control Devices. • Notify emergency services (253-852-2121) twenty-four (24) hours before any street or lane closures. • Any lane or street closures not in conformance with the approved traffic control plan and/or without notification of emergency services may result in receiving a citation for violation of R.C.W. 47.36.200 through 47.36.220, 9A.36.050 Reckless Endangerment, and other applicable State and City codes. • Indemnify and hold harmless the City of Renton from any and all claims, actions, and judgments, including all costs of defense and attorney’s fees incurred in defending against same, arising from and related to implementation of the approved traffic control plans including claims arising from towing of private vehicles and the acts of the Permit Holder’s agents and employees. • The City of Renton shall be entitled, in its reasonable discretion, to settle claims prior to suit or judgment, and in such event shall indemnify and hold harmless the City for any such claims paid, including the City’s reasonable attorney’s fees and litigation costs incurred resulting from such claim. • In the event any claim or suit is brought against City within the scope of this Agreement, Permit Holder will pay for legal counsel chosen by the City to defend against same. • Flagger and sign placement are subject to revision by the City Inspector on site, if needed to address traffic or pedestrian safety or travel. • By my signature herein, I acknowledge all the above requirements. PRINT NAME: DATE: SIGNATURE: Reset FormPrint Form Cascade Greens - 105086971 PSE/Potelco Inc. Dave Honeysett 253-245-0883 6905 S 228th St, Kent, WA 98032 dave.honeysett@pse.com 11427 SE 162nd St TBD TBD Anish Kumar 12/13/2017 MFP17005927 Justin Johnson 12-21-2017 8:00 am to 3:00 pm Monday through Friday SKETCH I -- NORTH -- I NOTES: • Work Zone Traffic Control shall be in accordance with the Manual on Uniform Traffic Control Devices (MUTCD) and shown by sketch or reference to WSDOT. • The plan must be submitted to the City’s PW/Transportation Division for review and/or approval at least three working days prior to work. • Approved Temporary Traffic Control Plan must be at the work site during work hours. • Contractor or entity must call Renton School District (425-204-4455) or any public/private agency to be affected by a temporary lane or road closure. • Complete assistance and accommodation shall be provided to all kinds of pedestrian traffic when sidewalk or walkway is impeded. • Total road closure lasting more than 24 hours is subject to the approval by the City Council. • Any vehicle, equipment, barricade, or portable tow-away sign used within the work area must display a company logo or any legally acceptable sign showing the company name, address, and telephone number at a conspicuous place on the vehicle or equipment. In the case of Temporary No Parking Zones, all the following apply in addition to previous: • Contractor must complete form to show limits of Temporary No Parking Zone identifying barricade locations for vacate parking or curb lane usage. • Contractor must post notice of dates and time of Temporary No Parking Zone with at least two signs per block 72 hours in advance of effective date and time. • The cover sheet of this Traffic Control Plan form must be attached to each Temporary No Parking Sign on the project site. • Temporary traffic control devices must be removed immediately when work is done or no construction activities are going on. If deemed abandoned, City crews will remove and store them at the City’s maintenance shop (3555 NE 2nd Street). 111112121111SE 162ND ST114TH AVE SE11427STOPFLAGGERSTOP FLAGGERFROMTOTOW AWAY AREAPHONE 888-9999INFRASOURCE LLC 000 0000000NO PARKINGBEPREPAREDTOSTOPW3-4100'100'100'ROADWORKAHEADW20-1W20-7A100'ROADWORKAHEADW20-1 100'ROADWORKAHEADW20-1 FROM TO TOW AWAY AREA PHONE 888-9999 INFRASOURCE LLC 000 0000000 NO PARKINGP01 RESIDENT(S) WILL BEINFORMED OF POSSIBLETEMPORARY DRIVEWAYCLOSURESE 162ND ST114TH AVE SE 1111BEPREPAREDTOSTOPW3-4BEPREPAREDTOSTOPW3-4100'100' MATCHLINE SEE BELOW BE PREPARED TO STOP W3-4100'100'100'ROAD WORK AHEAD W20-1W20-7A1212MATCHLINE SEE ABOVE SE 162ND STJob#10508697111427 SE 162ND ST, RENTON, WADecember 1, 2017Sheet 1 of 2 gregory.harwood@pse.com(425) 424-6425NPSEPUGETSOUNDENERGYTRENCH28" TRAFFIC CONELEGENDTRAFFIC FLOWWORK VEHICLESIGN LOCATIONWARNING FLAGFLAGGERSTOPTRAFFIC MANAGEMENT, INC.www.trafficmanagement.comC31 # 785804800.763.3999Traffic Control Services - Sales & RentalsPermits & Consulting - Engineering - TrainingPLAN PREPARED BY:DATE: 12/1/2017-JRPLAN ORDER: 31551TMI CONTACT PERSON: Michael FlanaganTCS CERT #: 301872CHANNELIZATIONDEVICE SPACINGMPH55/7035/4525/30TAPER403020TANGENT806040MINIMUM TAPER LENGTH = L (feet)LANEWIDTHSPOSTED SPEED LIMITS20253035404510111255 +60/6545/5535/403025SIGN SPACING"X"800500'350'200'100'Notes:1.All signs and spacing to conform to the MUTCD and City of RENTONstandards.2.All sidewalks, driveways, exits and egresses shall be completely clearunless otherwise indicated.3.Channelizing devices are 28" traffic cones.4.Sign size can be a minimum of 48" x 48" and shall not obstruct pedestrianaccess.5.Crew is required to leave a minimum of 11' for traveling lane width.6.Alert affected residents and businesses.7.Work to take place between 9 a.m. and 4 p.m.8.Contractor shall post temp "NO PARKING" 72 hours prior to construction.9.Work area will be APPROXIMATELY 240' ECL of 114TH AVE SE & on theNORTHSIDE of SE 162ND ST.POLEMFP17005927 111112121111SE 162ND ST114TH AVE SE11427STOPFLAGGERSTOP FLAGGERRESIDENT(S) WILL BEINFORMED OF POSSIBLETEMPORARY DRIVEWAYCLOSUREFROMTOTOW AWAY AREAPHONE 888-9999INFRASOURCE LLC 000 0000000NO PARKINGBEPREPAREDTOSTOPW3-4100'100'100'ROADWORKAHEADW20-1W20-7ABE PREPARED TO STOP W3-4100'100'100'ROAD WORK AHEAD W20-1W20-7A100'ROADWORKAHEADW20-1 100'ROADWORKAHEADW20-1 FROM TO TOW AWAY AREA PHONE 888-9999 INFRASOURCE LLC 000 0000000 NO PARKING 1212SE 162ND ST114TH AVE SE 1111Job#10508697111427 SE 162ND ST, RENTON, WADecember 1, 2017Sheet 2 of 2 gregory.harwood@pse.com(425) 424-6425NPSEPUGETSOUNDENERGYTRAFFIC MANAGEMENT, INC.www.trafficmanagement.comC31 # 785804800.763.3999Traffic Control Services - Sales & RentalsPermits & Consulting - Engineering - TrainingPLAN PREPARED BY:DATE: 12/1/2017-JRPLAN ORDER: 31551TMI CONTACT PERSON: Michael FlanaganTCS CERT #: 301872CHANNELIZATIONDEVICE SPACINGMPH55/7035/4525/30TAPER403020TANGENT806040MINIMUM TAPER LENGTH = L (feet)LANEWIDTHSPOSTED SPEED LIMITS20253035404510111255 +60/6545/5535/403025SIGN SPACING"X"800500'350'200'100'Notes:1.All signs and spacing to conform to the MUTCD and City of RENTONstandards.2.All sidewalks, driveways, exits and egresses shall be completely clearunless otherwise indicated.3.Channelizing devices are 28" traffic cones.4.Sign size can be a minimum of 48" x 48" and shall not obstruct pedestrianaccess.5.Crew is required to leave a minimum of 11' for traveling lane width.6.Alert affected residents and businesses.7.Work to take place between 9 a.m. and 4 p.m.8.Contractor shall post temp "NO PARKING" 72 hours prior to construction.9.Work area will be APPROXIMATELY 300' ECL of 114TH AVE SE & on theSOUTHSIDE of SE 162ND ST.TRENCH28" TRAFFIC CONELEGENDTRAFFIC FLOWWORK VEHICLESIGN LOCATIONWARNING FLAGFLAGGERSTOPPOLEMFP17005927 83.39'73.00'N01°32'53"E 299.93'73.00'70.00'S88°16'35"E 99.34'N01°32'53"E 299.01'73.00'73.00'70.00'83.01'S88°29'36"E 99.34'S88°16'35"E 99.34'S88°16'35"E 99.34'S88°16'35"E 99.34'LOT 4(6,954 SQ. FT)LOT 3(7,252 SQ. FT)LOT 2(7,252 SQ. FT)LOT 1(8,265 SQ. FT)SSSSSSWWW20' BSBL20' BSBL5' BSBL5' BSBL20' BSBL20' BSBL5' BSBL5' BSBL15' BSBL15' BSBL5' BSBL5' BSBL5' BSBL20' BSBL20' BSBL15' BSBL1+002+001142016044 11436 16204 11435 11445 11453 16220 12626 317002-166526 37.5 kVA 120/240V 316999-166523 25 kVA 120/240V (A) ERROR - SET SWITCH ID ERROR - SET SWITCH ID (ERROR-SET FUSE) SLAT8154 SE 162ND ST 114TH AVE SESS SS SSWWWWWWWWWWWWWWWSS JOB SITE 316999-166523 25 kVA 120/240V EXISTING 40T SW #T______ NEW 40T SW #T______ SITE PLAN N Vicinity Map N/A Owner / Developer Contact Info officeATTN: Sapphire Homes, Inc 16834 SE 43rd ST Bellevue, WA 98006 Travis Kassebaum (206) 484-4321 ARE TO BE INSTALLED, CROSS SECTION DETAILS OF THE TYPICAL EROSION STRUCTURES, & SPECIAL REQUIREMENTS FOR WORK IN SENSITIVE AREAS.) EROSION & SEDIMENT CONTROL REQUIREMENTS NOTES DETAILING WHERE EROSION OR SEDIMENT CONTROL STRUCTURES (LOCAL JURISDICTIONS MAY HAVE ADDITIONAL REQUIREMENTS INCLUDING 0150.3200 TECHNIQUES FOR TEMPORARY EROSION & SEDIMENT CONTROL EROSION & SEDIMENT CONTROL SHALL BE PER PSE STANDARD PRACTICE & ANY ADDITIONAL LOCAL JURISDICTION REQUIREMENTS. STANDARD EASEMENT PROVISION An easement is hereby reserved for and conveyed to Puget Sound Energy, Inc., Telephone Co., Television Cable Co., and their respective successors and assigns under and upon the private street(s), if any, and the exterior ten (10) feet of all lots, tracts and spaces with in the plat lying parallel with and adjoining all street(s) in which to construct, operate, maintain, repair, replace and enlarge underground or ground-mounted appurtenances thereto for the purpose of serving this subdivision and other property with electric, gas, telephone and other utility service, together with the right to enter upon the streets, lots, tracts and spaces at all times for the purposes herein stated.105086971FOREMAN (CHECK BOX WHEN COMPLETED) PSE Equipment LOCKED/SECURED & Work Area left in CLEAN/SAFE Condition. Grid, Cable, and Switch numbers INSTALLED & VERIFIED. Field Changes RED-LINED on As-built. Indicate correct FUSE SIZE on As-built & VERIFY proper PHASE. Foreman's Signature _______________________________________________ Print Name ___________________________________ Date ______________ Material VERIFIED and CHANGES noted on Paperwork. Total PRIMARY Cable noted on As-built. Company ID#'s RECORDED in correct location on As-built. Deviations noted on the As-built and their reason. I certify that the work performed meets PSE's standards and procedures and that all quality requirements are met. GAS PHONE CABLE TV N/A 101109015 N/A 108103767 N/A 593190248 N/A N/A N/A N/A N/A N/A N/A PROJECT PHASE PWR NOTIF#ORDER# Superior Perm. Service Relocation Removal Temporary Job Order Distribution HP Svc/MSA SITE SPECIFIC NOTES Phone INTOLIGHT Contact Information: N/A N/A SCHED.SQ. FT. MAX LRC = CIRCUIT FEET ADDED: ___ AMPS 10. 9. 8. 7. 6. 5. 4. 3. 2. 1.THE CUSTOMER IS RESPONSIBLE FOR PROVIDING ALL TRENCHING, PER THE TRENCH PROFILE, AND ALL EXCAVATIONS AT THE TRANSFORMER/HANDHOLE VAULT SITES SUCH THAT PSE FACILITIES WILL MATCH FINAL GRADE. VAULT HOLES WILL HAVE STABLE LEVEL BOTTOMS. CUSTOMER WILL PROVIDE 6" OF CRUSHED ROCK FOR VAULT BEDDING. ALL TRENCHES WILL HAVE 6" OF WASHED SAND COVER AND 4" BEDDING FOR ALL CONDUITS. THE CUSTOMER WILL PROVIDE SELECT BACKFILL, IF REQUIRED, AND COMPACTION AS NECESSARY. THE CUSTOMER IS RESPONSIBLE FOR DISPOSAL OF ALL NATIVE SPOILS NOT SUITABLE FOR USE AS BACKFILL. ALL TRENCHES MAY BE JOINT WITH GAS, TELEPHONE AND TV CABLE. ALL CABLES/CONDUITS TO BE INSTALLED IN CUSTOMER'S TRENCH AT THE DEPTH INDICATED IN TRENCH DETAIL (DEPENDENT UPON SIZE OF CONDUIT BEING INSTALLED TO MEET MIN 36" OF COVER). INSTALL CABLE ID TAGS AT EACH END OF THE PRIMARY CABLES PER THE CIRCUIT ONE-LINE DIAGRAM. UNLESS OTHERWISE SPECIFIED BY MUNICIPALITIES, INSTALL PVC (DB-120) ROAD CROSSINGS AS INDICATED ON THE CROSSINGS CONDUIT TABLE & AS SHOWN ON WORK SKETCH. CROSSINGS SHALL BE INSTALLED BY CUSTOMER/DEVELOPER PER PUGET SOUND ENERGY STANDARDS. AT SYMBOL: INSTALL UNDERGROUND PRIMARY CABLES IN CONDUIT. CABLE LENGTH AND CONDUIT SIZE AS INDICATED ON PRIMARY CABLE & CONDUIT TABLE. AT SYMBOL: INSTALL 600 VOLT UG SECONDARY CABLES IN CONDUIT. CABLE/CONDUIT SIZE AND LENGTH AS INDICATED ON SECONDARY CABLE & CONDUIT TABLE. AT SYMBOL: INSTALL MINI-PAD HANDHOLE & PADMOUNT TRANSFORMER. ADDITIONAL EQUIPMENT AS INDICATED ON VAULT TABLE. AT SYMBOL: INSTALL SECONDARY PEDESTAL/HANDHOLE W/ (3) MULTI-CONNECTORS. SIZE AS INDICATED ON SECONDARY HH/PEDESTAL TABLE. (EXCAVATION: 3' SQ.) AT SYMBOL: INSTALL JUNCTION BOX HANDHOLE. ADDITIONAL EQUIPMENT AS INDICATED ON VAULT TABLE. AT SYMBOL: INSTALL SECONDARY CABLE & CONDUIT STUB-OUT. AT SYMBOL: INSTALL STREET LIGHTING STANDARD. SIZE AND TYPE OF STANDARD/LUMINARIE AS INDICATED ON STREET LIGHTING TABLE. (CUSTOMER TO EXCAVATE & INSTALL CORRUGATED STREET LIGHT TUBES FOR PLACEMENT OF THE STREET LIGHT STANDARDS. ) INCLEMENT WEATHER CONDITIONS MAY CAUSE DELAYS IN CONSTRUCTION TIMES AND DATES. POWER GENERAL NOTES - PLAT PROJECT 11. E-Mail: Cell Phone: Project Manager Contact Information: Manager:Dave Honeysett (253) 245-0883 DAVID.HONEYSETT@PSE.COM PSE No No No Yes Yes Yes No YesDeveloper "Flagging Required" "Outages Required" "Locates Required" SCALE: 1" = 50' THIS SKETCH NOT TO BE RELIED UPON FOR EXACT LOCATION OF EXISTING FACILITIES CALL 811 TWO BUSINESS DAYS BEFORE YOU DIG For contacts below dial 1-888-CALL PSE (225-5773) UTILITIES CONTACT PHONE# COUNTY 1/4 SEC U-MAP NO (POWER) OP MAP Emer Sect Gas Wk Ctr POWER WK CTR PLAT MAP JOINT FACILITIES ARRANGEMENTS DRAWN BY CHECKED BY APPROVED BY FOREMAN #1 FOREMAN #2 MAPPING INCIDENT MAOP Gas Order Elect Order SCALE PAGE ENGR - POWER ENGR - GAS FUNCTION PROJECT MGR PERMITREAL ESTATE/EASEMENT 2 1 REV# 3 DATE DESCRIPTIONBY CONTACT PHONE NO DATE OH CKT MAP CIRCUIT NOUG CKT MAP Dave Honeysett (253) 245-0883 11/27/17 Nate Linville (253) 970-7284 11/27/17 N/A N/A N/A Nate Linville (253) 970-7281 Required City of Renton Cascade Greens 4 Lot Plat 1Ø PRIMARY LE, SET PM TRF, INST 2 - STUBS 11427 SE 162ND ST, RENTON, WA 98055 N/A N/A N/A 105086971 AS NOTED 1 OF 2 KING N/A N/A CSPSKEPM NE-29-23N-05E N/A N/A 2305E113 2305E136 2305E113 ROL-16 N/A N/A N/A N/A N/A N/A N/A N/A N/A N/A N/A N/A N/A N/A N/A N/A N/A N/A N/A N/A N/A Service Stubs 105086971 N/A N/A 505052286 N/A AT P01: REPLACE REMOVE EXISTING B/O 1981 40' DISTRIBUTION POLE TRANSFER EXISTING 25kVA 1B TO NEW POLE TRANSFER EXISTING LUMINAIRE TO NEW POLE (SLAT8154) TRANSFER EXISTING 1Ø 1/0 TERMINATION TO NEW POLE -INST. 1 - 45' CL2 DISTRIBUTION POLE PER STD 6010.1000 (PD452) -INST. 1 - 9' 8P XARM -INST. 1 PTP & INSULATOR -INST. 2 - STEEL ARM PINS & INSULATORS -INST. 1 - BOLTED STIRRUP & HOT CLAMP ON BØ -INST. 1 - L/B C/O ON NEW FG ARM, FUSE AT 40T PER STD 6043.1000 (TSU1C1) -INST. 1 - 12kV 1/0 SOL CS PIN TERMINATION PER STD 6041.3000 (TER10JC) -INST. CABLE # BØ-EHO831 -INST. NEW SW #T______ -INST. 1 - 2" PRIMARY RISER ON EXISTING S/O BRKTS PER STD 6042.1000 (RIS2CSS) EXISTING GRID 316999-166523 COMMUNICATIONS TO TRANSFER AT V01: NEW -INST. 1 - 36" X 42" X 38" UNI-STRUT MP HH W/21" X 24" ACCESS HOLE PER STD 6045.1010 (MINI1SR) -INST .1 - 37.5kVA 120/240V PM TRANSFORMER -INST. 1 - L/B ELBOW & 1 DUST CAP PER STD 6041.1000 (ELB10J) -INST. 3 - #6-350KCMIL 6POS SEC CONNECTION BLOCKS W/5/8" STUD ADAPTER (MID: 4842002) -INST. GRID 317002-166526 SPAN NOTES SEE CABLE TABLE ON P2 FOR CABLE AND CONDUIT INFORMATION DEVELOPER & CUSTOMER NOTES: THE CUSTOMER IS RESPONSIBLE FOR PROVIDING ALL TRENCHING, SELECT BACKFILL, COMPACTION & RESTORATION PER PUGET SOUND ENERGY STANDARDS 6750.6500 -REQUIRED TO PROVIDE 6' X 6' WORK PIT & 1 CUBIC YARD OF 5/8" MINUS AT V01 -REQUIRED TO PROVIDE 4' X 4' WORK PIT & 1 CUBIC YARD OF 5/8" MINUS AT P01 -REQUIRED TO FOLLOW ALL TRENCH DETAILS ON SELECT BACKFILL -REQUIRED TO PROVIDE EQUIPMENT TO PUMP OUT WATER FOR WORK PITS & TRENCH AT ALL TIMES -EXCAVATE & EXPOSE EXISTING PSE UG FACILITIES 48 HOURS PRIOR TO CONSTRUCTION -PSE INSPECTION IS REQUIRED PRIOR TO FINAL BACKFILL -PSE WILL NOT ENERGIZE FACILITIES UNTIL BACKFILL IS COMPLETE -L&I INSPECTION & APPROVAL IS REQUIRED 72 HOURS PRIOR TO CONNECTION -RESPONSIBLE FOR ALL TREE TRIMMING AND BRUSH CLEARING OVERHEAD CIRCUIT MAP (2305E136) SCALE: 6" = 1 MILE UNDERGROUND CIRCUIT MAP (2305E136) SCALE: 6" = 1 MILE CIRCUIT LOADING TABLE AS OF EXIST. PEAK LOAD EST. NEW LOAD TOTAL CIRCUIT: A PHASE B PHASE C PHASE ROL-16 6/13/17 205 191 213 -3.36 - 205 194.36 213 MFP17005927 9 0 ° 60'150'140'150'PSE PROVIDED 1 - 2" SCH80 PVC CONDUIT IN CUSTOMER TRENCH PSE PROVIDED 2 - 3" DB120 CONDUIT IN CUSTOMER TRENCH 316999-166523 25 kVA 120/240V EXISTING 40T SW #T______ NEW 40T SW #T______ JOB SITE 316999-166523 25 kVA 120/240V EXISTING 40T SW #T______ NEW 40T SW #T______ 397.5KCMIL ACSR 1 - 350KCMIL SEC TPLX NEW 1 - 1/0 AL SOL PRIMARY CABLE #BØ-EHO831 1 - 350KCMIL SEC TPLX PRIMARY & SECONDARY CONDUIT DIAGRAM N Vicinity Map N/A Owner / Developer Contact Info officeATTN: Sapphire Homes, Inc 16834 SE 43rd ST Bellevue, WA 98006 Travis Kassebaum (206) 484-4321 105086971FOREMAN (CHECK BOX WHEN COMPLETED) PSE Equipment LOCKED/SECURED & Work Area left in CLEAN/SAFE Condition. Grid, Cable, and Switch numbers INSTALLED & VERIFIED. Field Changes RED-LINED on As-built. Indicate correct FUSE SIZE on As-built & VERIFY proper PHASE. Foreman's Signature _______________________________________________ Print Name ___________________________________ Date ______________ Material VERIFIED and CHANGES noted on Paperwork. Total PRIMARY Cable noted on As-built. Company ID#'s RECORDED in correct location on As-built. Deviations noted on the As-built and their reason. I certify that the work performed meets PSE's standards and procedures and that all quality requirements are met. GAS PHONE CABLE TV N/A 101109015 N/A 108103767 N/A 593190248 N/A N/A N/A N/A N/A N/A N/A PROJECT PHASE PWR NOTIF#ORDER# Superior Perm. Service Relocation Removal Temporary Job Order Distribution HP Svc/MSA Phone INTOLIGHT Contact Information: N/A N/A E-Mail: Cell Phone: Project Manager Contact Information: Manager:Dave Honeysett (253) 245-0883 DAVID.HONEYSETT@PSE.COM PSE No No No Yes Yes Yes No YesDeveloper "Flagging Required" "Outages Required" "Locates Required" SCALE: NONE THIS SKETCH NOT TO BE RELIED UPON FOR EXACT LOCATION OF EXISTING FACILITIES CALL 811 TWO BUSINESS DAYS BEFORE YOU DIG For contacts below dial 1-888-CALL PSE (225-5773) UTILITIES CONTACT PHONE# COUNTY 1/4 SEC U-MAP NO (POWER) OP MAP Emer Sect Gas Wk Ctr POWER WK CTR PLAT MAP JOINT FACILITIES ARRANGEMENTS DRAWN BY CHECKED BY APPROVED BY FOREMAN #1 FOREMAN #2 MAPPING INCIDENT MAOP Gas Order Elect Order SCALE PAGE ENGR - POWER ENGR - GAS FUNCTION PROJECT MGR PERMITREAL ESTATE/EASEMENT 2 1 REV# 3 DATE DESCRIPTIONBY CONTACT PHONE NO DATE OH CKT MAP CIRCUIT NOUG CKT MAP Dave Honeysett (253) 245-0883 11/27/17 Nate Linville (253) 970-7284 11/27/17 N/A N/A N/A Nate Linville (253) 970-7281 Required City of Renton Cascade Greens 4 Lot Plat 1Ø PRIMARY LE, SET PM TRF, INST 2 - STUBS 11427 SE 162ND ST, RENTON, WA 98055 N/A N/A N/A 105086971 AS NOTED 1 OF 2 KING N/A N/A CSPSKEPM NE-29-23N-05E N/A N/A 2305E113 2305E136 2305E113 ROL-16 N/A N/A N/A N/A N/A N/A N/A N/A N/A N/A N/A N/A N/A N/A N/A N/A N/A N/A N/A N/A N/A Service Stubs 105086971 N/A N/A 505052286 N/A PRIMARY & SECONDARY CABLE DIAGRAM SCALE: NONE MINIMUM CLEARANCES FOR PSE EQUIPMENT NOT TO SCALE OIL-FILLED EQUIPMENT TRANSFORMER APPROVED AREA COMBUSTIBLE BUILDING WALLS & ROOF10' 10' 10' JOINT TRENCH DETAIL Primary Dirt Pile Final Grade 24" Min 36" Min Cover Over Power 48" Max Depth Final Backfill Gas 4" Sand Bedding Property Line intercept (depth varies). SidewalkCurb Location of roof drain 48" Typical Width may vary per Number of Utilities and Conduits 6" or 12" Min Sand Shading Over Gas after Compaction 12" Min R/W or Excavated 12" Typical Power Secondary Power TV & TEL NOTES: 1. If the final backfill contains rocks greater than 8 inches in diameter , install 12 inches compacted sand shading across the full width of the trench. * If the final backfill contains rocks 8 inches in diameter or smaller , install 6 inches compacted sand shading across the full width of the trench. * 2. Rocks greater than 10 inches diameter are not permitted in the final backfill. 3. Sand bedding is required under PSE gas pipe. Bedding is not required for the full width of the trench; it shall extend from the side of the trench nearest to where the gas main/service is installed to a minimum of 6 inches on the opposite side of the gas line. 4. Utilities shall not be stacked over the gas line in the trench. 5. If wet utilities will be included in the trench, please contact PSE or local power company directly for clearance requirements. 6. Reduced clearance of 4 inches between power and communication, must have approval of the communications companies. * Alternatives to full-width trench shading require PSE approval. 12" Min 12" Min Separation 4,5 1,2 1 3 6 6" or 12" Min Sand Shading Over Power after Compaction1 Primary & Secondary-Mainline Gas & Communications (NTS) TOP VIEW SIDE VIEW EXCAVATION: 4-2/3 CUBIC YARDS Rock Crushed 6" 3'-6" 2" 6' 6' 48"42" 36" 38" 42" Struts FRONT FRONTTRANSFORMER EXCAVATION DETAIL AT V01 SCALE: 6" = 1 MILE MINIMUM CLEARANCES FROM OIL-FILLED EQUIP. TO BLDG. FEATURES NOT TO SCALE FIRE ESCAPE SERVICE GAS RELIEF DOOR, WINDOW, VENT, OR OTHER OPENING TANK FUEL VENT OIL-FILLED ELECTRICAL EQUIPMENT SPRINKLER VALVE, STANDPIPE, OR HYDRANT 20' 3' 10' 6' 10' (TRANSFORMER) PRIMARY CABLE & CONDUIT TABLE LOCATION CONDUIT PRIMARY CABLE ASBUILT INFORMATION SIZE Qty LENGTH Design (ft) BENDS PULL PULL Cable LENGTH Design (ft) Cable Numbers Please Record Foreman - Complete FROM TO (in)90°45°22°11°(lbs) Rev (lbs)Size A B C Manufacturer Compound Year Actual Amount Installed (Conduit & Cable) P01 V01 1 2 210 2 0 0 0 PRI 12KV 1/0 UG 250 -EHO831 - SECONDARY CABLE & CONDUIT TABLE LOCATION CABLE Assumed Lot Corner CONDUIT VOLTAGE DROP VOLTAGE FLICKER ASBUILT INFORMATION SIZE LENGTH Design (ft) SIZE LENGTH Design (ft) BENDS Foreman - Complete FROM TO (1/0,4/0,350)to Meter(ft)(in)90°45°22°11°(Percent)(Percent)Actual Amount Installed (Conduit & Cable) V01 LOT 3 4/0 UG TPX 160 40 3 140 1 0 0 0 1.6%3.7% V01 LOT 4 350KCMIL UG TPX 170 40 3 150 1 0 0 0 1.5%3.2% CROSSINGS CONDUIT TABLE X-ING NO. LOCATION GAS POWER Length Remarks (type of crossing) SIZE Type Qty Location SIZE Type Qty (Primary, Feeder, Secondary, St. FROM TO (in)sched each N-S-E-W (in)sched each (ft)Light, Gas Only, etc.) X01 P01 V01 2 DB120 2 60 PRIMARY 60'= 2" SCH80 GREY PVC (ft) 0 = 3" DB120 GREY PVC (ft) 0 = Total 2" PVC Plug / Caps 0 = Total 3" PVC Plug / Caps Total Glue = 0.5 Qts Total E 60' COOLING 5' MIN 5' MIN 10' MIN 5' MIN FINS ACCESS CONCRETE PAD MINIMUM CLEARANCES FOR PSE EQUIPMENT NOT TO SCALE CURB OR EDGE OF PAVEMENT CURB OR EDGE OF PAVEMENT 5' MIN ROAD OR PARKING AREA TYP. PAD & TRANS- FORMER 3' MIN 3' MIN 3' MIN DOOR ACCESS DOOR REQUIRED WORK SPACE AREA MFP17005927 TO: City of Renton RE: PSE Job Number 105086971 TYPE OF WORK: Changing out BO pole grid # 316999-166523 installing new class 2 45’pole approx. same location transfer all hardware, re-connect existing services, install New risers, install OH to UG primary L/E for new 4 lot plat south of existing OH service. LOCATION OF WORK: 11427 SE 162nd ST, RENTON, WA. 98055 SCOPE OF WORK: At location P01 as shown on the attached copy of the worksketch, PSE is requesting exemption to change out old pole and install new pole so we can extend primary from P01 to V01 OH to UG service. We have submitted along with this the design for approval and traffic control plans for this work. Give me a call if there are any questions on the work to be done. Sincerely, David Honeysett Puget Sound Energy Project Manager Customer & System Projects Cell: (253) 254-0883 David.Honeysett@PSE.com MFP17005927